Professional Documents
Culture Documents
REFERENCES: RD201
Table: 2
Li = Distance between fixing hole centres (single displacement flow divider)
Number of elements
Cm 3 /rev A IN OUT 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 1 4 1 5 1 6
4 47 3/4 BSP 1 /2 BSP 21 8 309 400 491 582 673 764 855 946 1 037 11 28 1 21 9 1 31 0 1 401 1 492
6 50 3/4 BSP 1 /2 BSP 224 31 8 41 2 506 600 694 788 882 976 1 070 11 64 1 258 1 352 1 446 1 540
9 54 3/4 BSP 1 /2 BSP 232 330 428 526 624 722 820 91 8 1 01 6 111 4 1 21 2 1 31 0 1 408 1 506 1 604
11 58 3/4 BSP 1 /2 BSP 240 342 444 546 648 750 852 954 1 056 11 58 1 260 1 362 1 464 1 566 1 668
14 64 3/4 BSP 1 /2 BSP 252 360 468 576 684 792 900 1 008 111 6 1 224 1 332 1 440 1 548 1 656 1 764
17 68 3/4 BSP 1 /2 BSP 260 372 484 596 708 820 932 1 044 11 56 1 268 1 380 1 492 1 604 1 71 6 1 828
19 72 3/4 BSP 1 /2 BSP 268 384 500 61 6 732 848 964 1 080 11 96 1 31 2 1 428 1 544 1 660 1 776 1 892
22 78 3/4 BSP 1 /2 BSP 280 402 524 646 768 890 1 01 2 11 34 1 256 1 378 1 500 1 622 1 744 1 866 1 988
26 82 1 BSP 3/4 BSP 288 41 4 540 666 792 91 8 1 044 11 70 1 296 1 422 1 548 1 674 1 800 1 926 2052
30 90 1 BSP 3/4 BSP 304 438 572 706 840 974 11 08 1 242 1 376 1 51 0 1 644 1 778 1 91 2 2046 21 80
34 97 1 BSP 3/4 BSP 31 8 459 600 741 882 1 023 11 64 1 305 1 446 1 587 1 728 1 869 201 0 21 51 2292
40 1 06 1 BSP 3/4 BSP 336 486 636 786 936 1 086 1 236 1 386 1 536 1 686 1 836 1 986 21 36 2286 2436
Table: 3 in this table the number of inlets in function of the number of elements are indicated.
Number of elements 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 1 4 1 5 1 6
"IN" Number of inlets 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8
Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
4
FLOW DIVIDER "RV" Series Swallow Line RV-2D
Flow divider (Standard Version)
INTERNAL DRAIN
In table 3 the number of inlets in fuction of the number of elements are indicated.
For flow dividers with many inlets, as they are all communicating it is even possible to use only one of them, by plugging the
other ones. We suggest to use at least one 3/4" BSP inlet every 80 l/min capacity and at least one 1 " BSP inlet every 1 20 l/min
capacity
To obtain errors of division inferior to 3% there must be no difference of pressure between the elements superior to 30 bar. To
obtain high precisions the respect of the following parametres is also important:
- Enviroment temperature: -1 0°c ÷ +60°c Oil temperature: +30°c ÷ +60°c
- Hydraulic oil based on hlp, hv (din 51 524) minerals Oil Viscosity 20 ÷ 40 cSt
- Oil filtering 1 0 ÷ 25 µ
Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
5