Professional Documents
Culture Documents
NORTH TRUE
NORTH
25°
480800
90300
KEY PLAN
15050 30100 30100 15050
50 30000 50 NOTE
350 10050 9200 10050 350 1. ALL DIMENSIONS ARE IN MILLIMETERS.
2. ALL COORDINATES AND ELEVATIONS ARE IN METERS
UNLESS OTHERWISE NOTED.
3. GL. (±)0.00M = EL. (+)5.10M (HON DAU LEVEL)
FL.(±)0.00M = GL. (+)0.3M = EL. (+)5.40M (HON DAU LEVEL)
4. FOR GENERAL NOTES, SEE DWG. NO.
QT1-0-C-U__-02-00001~00003.
TRESTLE PIER PILE CAP 5. TIDAL INFORMATION IS REFERENCED AS BELOW.
(TYP.) - HIGHEST HIGH WATER LEVEL (H.H.W.L.) : E.L. (+)1.34m
2@1600
=3200
5@2350=11750
14950
MATERIAL
11750
1. CONCRETE
STRUCTURE CYLINDER CEMENT
TYPE STRENGTH TYPE
IN-SITU CONCRETE 35MPa ASTM C150 TYPE II
PRECAST CONCRETE 35MPa ASTM C150 TYPE II
PSC BEAM 40MPa ASTM C150 TYPE II
BORED PILE 35MPa ASTM C150 TYPE II
PSC BEAM CROSS BEAM LEAN CONCRETE 13MPa ASTM C150 TYPE I
(TYP.) (TYP.)
- ADDITIONAL FLY ASH IN CEMENT WILL BE PROVIDED
FOR THE CONCRETE OF ACCESS BRIDGE FOR COAL JETTY.
2. RE-BAR
- DEFORMED BARS
- fy = 400MPa
- TCVN 1651-2:2018 GRADE CB400-V
OR JIS 3112 GRADE SD390
3. STEEL CASING FOR BORED PILE
480800 - fy = 235MPa
90300
LEGEND
15050 30100 30100 15050
: PRE-STRESSED CONCRETE BEAM TYPE
50 30000 50
2@1600
=3200
QUANG TRACH I THERMAL POWER PLANT
38/2021/QT1-EVNPMB2-MC-HDEC-CC1
5@2350=11750
5@2350=11750
14950
11750