You are on page 1of 8
REZONTECH FLAME DETECTOR THE BEST SOLUTION FOR FIRE DETECTION SYSTEM REZONTECH FLAME DETECTOR Designed and manufactured in South Korea, under Rezontech’ s technology and the own strict quality control system with international laboratories such as FM, ATEX, CCCF, IECEX, KFI(Korea Fire Institute) and so on. This expertise and responsibility for quality will make Rezontech meet all your needs from the fire detection. Rezontech Co, Ltd. is the world-class Flame Detector Manufacturer has been leading Flame Detector market in Korea since 2004. We developed first-ever UV/IR & Triple IR type Flame Detectors in Korea with own unique technology. Rezontech keeps growing with continuous R&O for fire detection technology. Thus we acquired 20 global certificates and approvals on Flame Detectors and exported it over 50 countries in the world. We are proud to supply state of the art Flame Detectors along with the Automatic Gas Suppression system to the industry leading sites & military facilities to protect hurnan life & asset from the fire disaster. We will conquer the global market based on our continuous effort, know-how & reliability with the best service and best quality Bf PRINCIPLE The Rezontech flame detector can promptly analyze sensory inputs fromm the ultraviolet and infrared light sources emitted by a flame to alert against fires IRB flame detection sensing three specific wavelength bands within the Infrared spectral region that are algorithmically analyzed, UV/IR flame detector uses UV/IR wavelength signals comparing to detect fire and minirnizes false alarm. Flame detectors are less spatial and environmental constraints such as outdoor high ceilings of industrial sites, where ordinary heat/smoke detectors cannot be used. Bf) ADVANTAGES Cost effective design Providing an economical solution by long and wide detection range False alarm immunity Highly precise and responsive detection using our own unique algorithm Fast Delivery Best efforts to the faster delivery to satisfy our valuable customers J APPLICATION = Oil & Gas Facilities = Iron & Steel Facilities = Power Station = Chemical Facilities * Shipyards Explosion-Proof Achieved international certificates tobe used in hazardous areas Early Fire detection Flame Detector can detect fire typically within 5 seconds using optical Ultraviolet and Infrared sensors Easy installation Simple and easy Installation for anyone and any site * Automobile Manufacturing Facilities = Refineries = Semi-Conductor Facilities = UNESCO World Heritage = Historical Site i UV/IR FLAME DETECTOR ®O® RFD -2000 Type | wwe ner al tia ty Weight | 543 Response lays seconds tre Range| 40% 10573 HumiaityRange|Up 095 eave homily, ELECTRICAL SPECIFICATION Operating Voltage |28VDC (17 032 VOC) Power Consumption |r (utp Ray Conta Ful Waring la) A485 Prepratary Communication onde Entry Sie 1h PF [APPROVALS RFD-2000X Type | vin Model | r-2000% Detection Range |28t30m) Weight] 3249 Fie of view] =90"V90" Respense| ial Seconds ature Range | 40% to 7S (Upto 95 else humity CAL SPECIFICATION Operating Veltge |24VDC (17 VOC 3200 Power Consumption | 8" maximum a32VDC ‘Output ely contacts re Fault Waring Aa) £5485 proprearyConmunston Condi Entry Sine | 12° NT DO neh [APPROVALS Performance 46260 Explosion Pref] FM Class Dison 1 Goups8 Cando, Casson 1 Groves, F and, cls ATERECEx Bb 2,16 Protection [P67 NEMA ype 8k ype |v Medel |s10-2F7% Detection Range | 28st 30m) Fier View Response pial S seconds ‘Operating Temperature Range| 40% t0 +75 Humidity Range] Upto 95 else humity Enclosure Material | Aluminum 6061 Dementon [et HEA 075mm Weight|oss¢ ELECTRICAL SPECIFICATION ‘OperstingVltge |24VDC (17 VOC 2 v0) ‘tpt | ely contacts re Fale Waring Ae) {42am curent Outout 155 Proprietary Communiaton conde Entry Sine |1/9 neh PT ‘APPROVALS: Performance Cr AF Explosion Prot] APEX MEPS X-cOsT ‘EXER abc /75 Gb AIBXEXDIICTASTC TIS 0D Protection P66 P67 Bj 'R3 & HYDROGEN FLAME DETECTOR ©88® @ RFD -3000 ‘ype Enclosure Material | Aluminum Aly Mode!| 370-3000 Dementon W150 103 D125mm Detection Range) 197%0n) Weight] Field of view [H90"\90" Response lays seconds tre Range| 40% 10573 [pte si rete nemity ELECTRICAL SPECIFICATION Operating Voltage |28 VOC (18D 9 3000) Conduit Entry Size] 2172 P= [APPROVALS Performance 3260, CCF Protection | P7, NEMA Type RFD -3000X Response [Tpialy seconds emit Range|U> ‘095 eave homily ELECTRICAL SPECIFICATION Operating Voltage | 28 DC (18¥2C 2 30¥0C) Power Consumption 45 mame 3010 ‘Output [Relay Contacts fre Fut Waning Alam) 85485 Proprietary Communcaton Condit Entry See] 1/2 NPLM2OX 1 5 08 [APPROVALS Performance F260, CCC Explosion Prof FM Cass Divslon 1 Groups 8, Cand D cass Dison 1 Grou Fan las ATEXIECENNEPS Ex 2.13, Protection P65, P67, NEMA Type Pe mater sour Detection Range | 9851 (30m) frm Heptane fre ortbage te ne pue Fel of view 90" Operating Temperature Range | 40% t0/S Weight | 3245 Humidity Range|Upt0 95% rlstvehumity Response Typical Seconds ELECTRICAL SPECIFICATION ‘OperstingVeltge |24VDC (17 VOC 3200 Power Consumption | 8 maximum a 32VDC ‘Output | ely contacts re Fale Waring Am) ‘420m curent Oxo, Fst Proprietary Communiaton ‘Cond Enry Sze |2 V2 N27. MON neh [APPROVALS Performance 40260 rot | MCs! Ovo 1 Groups, Cand Olas IDion Groups Protection P67, NEMA Type AK TEST LAMP & ACCESSORIES FLAME DETECTOR TESTER Rezontech test lamp produces a particular frequency of IR and UV radiation to exclusively test Rezontech flame detectors within 30 seconds. Rezontech test lamp is proper to use in hazardous areas because it can make the flame detector tested without the needs of an actual fire. PRODUCTS TL-3000 * Operation Distance | 3m (Max. Sm) += Target Model | RFD-3000 and RFD-3000X "Operation Time | Max. 3.5 hours = Dimension & Weight | About 3.2kg / 250mm X 145mm, * Enclosure | Alurninium (Anodizing Process) = Temperature Range | Operating :0°C to 50°C Storage :-10°C to 60°C TL-205 * Operation Distance | 3m (Max. 5m) + Target Model | UVAR flame detector "Operation Time | Max. 2hours * Dimension & Weight | About 3.2kg / 250mm X 145mm. * Enclosure | Aluminiurn (Anodizing Process) = Temperature Range | Operating :0°C to 50°C Storage :-10°C to 60°C Sess od Explosion Bec RFD-2000 | UV/IR 30m so" 8 ys] pM - FM RFD-2000x | _UV/IR 30m 90° i rM ATEX IECEX FM Appts ls coo] Y/R 30r 907 FM rn 7 1m Y , Flame ATEX Detector FM TECEX RFD-3000x | RB om 90° | cor | FMEATEX a (CNEX) , FM RFD-3000 | IRB 60m 90 vl ee : ATEX RFD2FIN | UV/IR 30m 100" er INEPSI | EX-GOST KF RFD-2TN | UV/IR 30m 100" ie. KF - Approved Sy, Flame . Detector | RFDSFT | IR som 90 2) Fl kes RFDST Rs, som so" @ Fi - IJ AccessorrIes 4h ere BK-O1 BK-02 RSC-05 RSc-02 THE BEST SOLUTION FOR FIRE DETECTION SYSTEM REZONTECH Rezontech Building, 72-9 Beolmal-st, Donggan-gu, Anyang-si, Gyeonggi-do, South Korea Tel. + 82-31-348-4246~8 Fax. +82-31-348-3004 E. sales@rezontech.com Web. www.rezontech.com

You might also like