Flow transmitters
SITRANS FM (electromagnetic)
SITRANS FM MAG 6000 I and 6000 I Ex
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
Overview Design
Function
SITRANS FM (electromagnetic)
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
Article No.
SITRANS FM Transmitter MAG 6000 I 7ME6930-
Remote with standard wall mounting bracket, local display, die cast aluminum
2 B A ● ● - 1 ● A 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Supply voltage
Standard transmitter: 18 ... 90 V DC; 115 ... 230 V AC, 50 ... 60 Hz 2
Ex transmitter: 18 ... 30 V DC 4
Ex transmitter: 115 ... 230 V AC, 50 ... 60 Hz 5
Ex approval
Standard sensor: FM Class I, Div 2, CSA Class I, Div 2 0
Ex sensor: Hazardous area (ATEX 2 GD; FM Class I, Zone 1; CSA Class I, Zone 1) 2
Standard sensor: Non-hazardous area 3
Communication
None A
HART B
PROFIBUS PA Profile 3 F
PROFIBUS DP Profile 3 (not for Ex version) G
Modbus RTU/RS 485 (not for Ex version) E
FOUNDATION Fieldbus H1 J
Cable gland entries
Metric 0
½" NPT 2
1) Product Variation Request (PVR).
Order code
Further design
Please add “-Z“ to Article No. and specify Order code(s) and plain
text
Tag name plate, stainless steel (specify in plain text) Y17
Tag name plate, plastic (self-adhesive) Y18
Special version (specify in plain text) Y99
Communication modules for MAG 6000 I (All standard outputs can still be used)
SITRANS FM (electromagnetic)
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
Spare parts
SITRANS FM (electromagnetic)
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
SITRANS FM (electromagnetic)
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
MAG 6000 I and MAG 6000 I Ex MAG 6000 I and MAG 6000 I Ex
Mode of operation Design
Measuring principle Electromagnetic with pulsed constant field Enclosure material Die-cast aluminum, with corrosion resistant
Basic Polyester powder coating (min. 60 µm)
Empty pipe Detection of empty pipe (special cable
required in remote mounted installation) • Wall mounting Wall mounting bracket enclosed for remote
version
Excitation frequency Depend on sensor size
Dimensions See dimensional drawings
Electrode input impedance > 1 × 1014 Ω
Weight See dimensional drawings
Input
Power supply • Standard transmitter: 18 … 90 V DC;
Digital input 11 … 30 V DC, Ri = 4.4 kΩ
115 … 230 V AC; 50 … 60 Hz
• Activation time 50 ms
• Ex transmitter: 18 … 30 V DC
• Current I11 V DC = 2.5 mA, I30 V DC = 7 mA • Ex transmitter: 115 … 230 V AC;
50 … 60 Hz
Output
Current output Power consumption • 230 V AC: 20 VA
• Signal range 4 … 20 mA (active/passive) • 24 V DC: 9.6 W, IN = 0.4 A, IST = 1 A (3 ms)
Certificates and approvals
• Load < 560 Ω
General purpose • CE (LVD, EMC, PED, RoHS)
• Time constant 0.1 … 30 s, adjustable
Hazardous areas • ATEX, IECEx, FM, CSA, EAC Ex, NEPSI
Digital output
- Zone 1 Ex d e [ia] ia IIC T6 Gb
• Frequency 0 … 10 kHz, 50 % duty cycle (uni-
/bidirectional) • ATEX, IECEx, CSA
- Zone 21 Ex tD A21 IP67 T85 °C
• Time constant 0.1 … 30 s, adjustable
• FM
• Pulse (passive) 3 … 30 V DC, max. 110 mA (30 mA Ex
version), 200 Ω ≤ Ri ≤ 10 kΩ (powered from - XP IS Class I Div. 1 Groups A, B, C, D
connected equipment) - DIP Class II+III Div. 1 Groups E, F, G
• Time constant 0.1 … 30 s, adjustable
Others • CPA (China)
Relay output • EAC (Russia, Belarus, Kazakhstan)
• Time constant Changeover relay, same as current output • KCs (South Korea)
• Load 42 V AC/2 A, 24 V DC/1 A Cable entries
Low flow cut off 0 … 9.9 % of maximum flow MAG 6000 I
Galvanic isolation All inputs and outputs are galvanic isolated. • Power supply and outputs 2 × M20 (HART)/M25 (PROFIBUS) or 2 × ½"
Max. measuring error NPT (HART)
MAG 6000 I/MAG 6000 I Ex (incl. sensor) ± 0.2 % ± 1 mm/s • Sensor connection 2 × M16 or 2 × ½" NPT
SITRANS FM (electromagnetic)
Flow transmitters
SITRANS FM MAG 6000 I and 6000 I Ex
Dimensional drawings
250 (9.84)
220 (8.66)
248 (9.76)
Ø 80 (3.15)