Keep the WAT-525EX2/535EX2 dry at all times during storage 9) Set the ⑪FUNCTION SWITCHES
and operation. Before connecting the auto-iris lens, please make sure that the pin according to your requirements.
• Should the camera not work properly, switch off the power configuration is correct by confirming with the following table. If the
immediately. Then check the camera according to the configuration of your iris connector is different from the following, the plug BLC targeted area
“Problems and Trouble shooting” section. and pins will need to be rewired.
Lens Mount Cap WAT-525EX/535EX DC Plug Iris Connector Upon
Switch Setting Effective Condition (Example)
EIAJ Video EIAJ DC Shipment
Caution
• Avoid the striking of hard objects or dropping the WAT-
525EX2/535EX2.
Description of Parts ④ ② Pin No. Auto-iris Lens
Arrangement
Auto-iris Lens
Arrangement ON
・ When minimum illumination is more
important than the S/N ratio
The WAT-525EX2/535EX2 uses high quality electrical parts 1. [HI] (Surveillance in a low light
and precision components. ① Power Control - environment)
AGC
• Do not connect any power supply directly to the video out
② Not used Control + OFF ・ When a clear picture is required in
terminal of the unit. ③ ① [LO] standard lighting conditions
Do not connect the WAT-525EX2/535EX2 with any monitor ③ Iris signals Drive +
using a video/power single transmission terminal. The 2. ・ Applicable to a general surveillance
④ Common (GND) Drive - ON
WAT-525EX2/535EX2 is not designed for use with this type of monitoring system
Gamma
equipment. We also advise you to read the operation manual correction ・ When gamma correction is not
of the monitor you plan to use before any connections are OFF
made. Set-up and Operation required for image processing
• Do not install the WAT-525EX2/535EX2 in a position ・ When the picture of the monitored
subject to direct sunlight. 1) Ensure that the power to the WAT-525EX2/535EX2 and the peripheral 3. ON object is silhouetted due to strong
Sunlight shinning directly onto the WAT-525EX2/535EX2 lens equipment is turned off before making any connections. lighting from above or behind
can cause damage to the CCD. 2) Remove the lens mount cap from the WAT-525EX2/535EX2 and attach BLC ・ When the illumination differences
• Select a stable place for installation of the WAT-525EX2/ the CS-mount lens. Use the optional C-mount adaptor(34CMA-R) when OFF between a monitored object is
535EX2. a C-mount lens is used. narrow
Use a support of durable strength around an installation 3) Connect the iris control cable to ⑤AUTO-IRIS SOCKET on the WAT-
position on a ceiling or wall when a camera stand or tripod is 525EX2/535EX2 when an auto-iris lens is being used. ※BLC is available when ⑫AE MODE CONTROL is set to position 8(EI) or
used. when auto-iris lens is used.
10) Set the gain control to any required environment.
For AGC, turn the AGC control anti-clockwise to the
locking position. AGC automatically adjusts to a Contact information
range between 5 to 32dB(HI)/5 to 20dB(LO).
• Design and specifications are subject to change without notice.
With MGC, gain is manually adjusted in a range • Watec is not responsible for any inconvenience or the attendant damages
between 5 to 32dB. In a low light environment, to the video and monitoring recording equipment caused by misuse, mis-
when illumination of the object is important, operation or improper wiring of our equipment.
increase the manual gain. Lower the gain control • If for any reason the WAT-525EX2/535EX2 does not work properly, or if
for a clearer picture with less noise. you have any questions regarding installation or operation, please
11) When the external sync. function is required, input the composite video contact the distributor or dealer from which it was purchased.
or the composite sync. signal to ⑨SYNC IN. The range of the level for
composite sync. is 0.2 to 5.0V(p-p). The camera has a resistance of
10kΩ. When more than 75Ω termination is required for impedance Contact information
matching, add the additional Ωs to the external sync. signal line.
1420Z00-Y2000005
Bracket (B003)