You are on page 1of 1

[Summary]

Site Name: No Site Name Defined.


Site ID: No Site ID Defined.
Standby Message: No Standby Message Defined.
Author: No Author Defined.
Panel Version:
Time Created: June 22, 2023 01:57:11 AM
Time Last Changed: June 22, 2023 01:57:11 AM

[SLC and Expansion I/O]


Logical Address: 1
Module: PMU
Location:
Parameters: Marine=N, 2 PSUs=N, Charge Batteries=N, Aux 1 Resettable=N, Aux 2
Resettable=N

Logical Address: 1
Module: SLC
Location:
Parameters: Wiring=Class B Style 4, Degrade NAC#1=N, Degrade NAC#2=N

Logical Address: 2
Module: SLC
Location:
Parameters: Wiring=Class B Style 4, Degrade NAC#1=N, Degrade NAC#2=N

[EOC]
No EOC Lines Defined!

[On-Board Circuitry]
Type: NAC
Enabled: Enabled
EOC Address: SG1
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N

Type: NAC
Enabled: Enabled
EOC Address: SG2
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N

Type: R-NAC
Enabled: NAC
EOC Address: SG3
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N

Type: R-NAC
Enabled: NAC
EOC Address: SG4
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N

Type: Relay
Enabled: Enabled
EOC Address: RY1
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N

Type: Relay
Enabled: Enabled
EOC Address: RY2
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N

Type: Relay
Enabled: Enabled
EOC Address: RY3
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N

Type: Relay
Enabled: Trouble
Owner Location: TROUBLE RELAY

[Day/Night Setting]
Use Night-time: No
Settings at Night

[Display Loop]
Type: MAIN
Location: CONTROL UNIT MAIN DISPLAY

[String Variables]
No Strings defined!

[Global Settings]
Central Station: Disabled
City Of Chicago: Disabled
ULC Operation: Disabled
Global Acknowledge: Enabled
Global Alarm: Disabled
Acknowledge
Time/Date Display: AM/PM
Silence Inhibit: 0 mins
Printer Port: Disabled
ICM Port: Disabled
Drill Notification: 60 bpm.
Pattern
AC Fail Delay: 6 (hr.)
Sequential De-: 5 (sec.)
activation Timer (for
Addressable Relays)
Alarm Verification: 60 (sec.)
Confirm
Positive Alarm: 0 (sec.)
Sequence
Nightly SLC: 02:00 (military)
Test Time
Supervise Batteries: Enabled

[Macro #1]
Description: No Description entered!
No Commands entered!
[Macro #2]
Description: No Description entered!
No Commands entered!
[Macro #3]
Description: No Description entered!
No Commands entered!
[Macro #4]
Description: No Description entered!
No Commands entered!

[Softkeys]
Softkey #1 Type: Disabled
Softkey #2 Type: Disabled
Softkey #3 Type: Disabled
Softkey #4 Type: Disabled

[Call For Service]


No Call for Service text entered!

[RRM Release Group (RG) Locations]


No RRM Release Group (RG) Locations entered!

[Output Group (OG) Locations]


No Output Group (OG) Locations entered!

[SLC #1 Devices]
No SLC Devices registered!

[SLC #2 Devices]
No SLC Devices registered!