Logical Address: 1
Module: SLC
Location:
Parameters: Wiring=Class B Style 4, Degrade NAC#1=N, Degrade NAC#2=N
Logical Address: 2
Module: SLC
Location:
Parameters: Wiring=Class B Style 4, Degrade NAC#1=N, Degrade NAC#2=N
[EOC]
No EOC Lines Defined!
[On-Board Circuitry]
Type: NAC
Enabled: Enabled
EOC Address: SG1
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N
Type: NAC
Enabled: Enabled
EOC Address: SG2
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N
Type: R-NAC
Enabled: NAC
EOC Address: SG3
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N
Type: R-NAC
Enabled: NAC
EOC Address: SG4
Owner Location:
Parameters: General Alarm Activation=N, Code Pattern=cont., Sil. Horn/Non-Sil.
Strobe=N, Sil.=N, Walk=N, Drill=N
Type: Relay
Enabled: Enabled
EOC Address: RY1
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N
Type: Relay
Enabled: Enabled
EOC Address: RY2
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N
Type: Relay
Enabled: Enabled
EOC Address: RY3
Owner Location:
Parameters: General Alarm Activation=N, Loss of AC=N, Pre-Alarm=N, Supv.=N,
Trouble=N
Type: Relay
Enabled: Trouble
Owner Location: TROUBLE RELAY
[Day/Night Setting]
Use Night-time: No
Settings at Night
[Display Loop]
Type: MAIN
Location: CONTROL UNIT MAIN DISPLAY
[String Variables]
No Strings defined!
[Global Settings]
Central Station: Disabled
City Of Chicago: Disabled
ULC Operation: Disabled
Global Acknowledge: Enabled
Global Alarm: Disabled
Acknowledge
Time/Date Display: AM/PM
Silence Inhibit: 0 mins
Printer Port: Disabled
ICM Port: Disabled
Drill Notification: 60 bpm.
Pattern
AC Fail Delay: 6 (hr.)
Sequential De-: 5 (sec.)
activation Timer (for
Addressable Relays)
Alarm Verification: 60 (sec.)
Confirm
Positive Alarm: 0 (sec.)
Sequence
Nightly SLC: 02:00 (military)
Test Time
Supervise Batteries: Enabled
[Macro #1]
Description: No Description entered!
No Commands entered!
[Macro #2]
Description: No Description entered!
No Commands entered!
[Macro #3]
Description: No Description entered!
No Commands entered!
[Macro #4]
Description: No Description entered!
No Commands entered!
[Softkeys]
Softkey #1 Type: Disabled
Softkey #2 Type: Disabled
Softkey #3 Type: Disabled
Softkey #4 Type: Disabled
[SLC #1 Devices]
No SLC Devices registered!
[SLC #2 Devices]
No SLC Devices registered!