You are on page 1of 2

Deployment Environments Recommendations Technical Support and Hotline

The manufacturer cannot be held responsible in case of non-compliance with the


MorphoAccess® SIGMA Series
Operating temperature -20° to +60 °C (4°to 140°F) following recommendations or incorrect use of the terminal. USA & Canada
Operating humidity 10 % < RH < 80 % (non condensing) Mail: support.bioterminals.us@idemia.com Quick Installation Guide
Repair and Accessories Tel: +1 888 940 7477
Storage temperature - 25° to + 70 °C (-13° to 158°F) • Do not attempt to repair the MorphoAccess® SIGMA Series terminal yourself.
Storage humidity 5% < RH < 95 % The manufacturer cannot be held responsible for any damage/accident that may LATAM (Latin America)
IP65 rated, once wall-mounted result from attempts to repair components. Any work carried out by non-
IP code Mail: support.bioterminals.us@idemia.com
For UL 294 compliance, the products are rated for indoor use authorized personnel will void your warranty. (WR)
• Only use the terminal with its original accessories. Attempts to use unapproved
Tel: +1 714 575 2973
accessories with your terminal will void your warranty.
General precautions EMEA (Europe, Middle-East, Africa)
➢ Do not expose the terminal to extreme temperatures. Micro SD Card Mail: support.bioterminals@idemia.com
➢ When the environment is very dry, avoid synthetic carpeting near the • The micro SD card is linked to the terminal : it shall not be transferred from one Tel: +33 1 30 20 30 40
MorphoAccess® SIGMA terminal, to reduce the risk of unwanted electrostatic product to another.
discharge. APAC (Asia & Pacific)
Date / Time synchronization
• The MorphoAccess® SIGMA Series terminal clock has a +/- 10 ppm typical time
Mail: support.bioterminals.in@idemia.com
Areas containing combustibles Quick

deviation at +25ºC (roughly +/- 3sec per day). At lower and higher temperature, Tel: +91 8929 159 665 WEEE
➢ Do not install the terminal in the vicinity of gas stations or any other installation Guides

containing flammable or combustible gases or materials. The terminal is not deviation may be greater (maximum : 8sec per day).
designed to be intrinsically safe. • When the terminal is used for applications requiring high time precision, it is India
strongly recommended to synchronize the terminal with an external clock.

293732930-G
Mail: support.bioterminals.in@idemia.com For further installation guidance refer to installation
manual part number 2014_0000000606
The terminal should be installed in controlled lighting conditions
➢ Avoid biometric sensor exposure to a blinking light. Firmware release Tel: +91 1800 120 203 020
➢ Avoid direct exposure of the biometric sensor to sunlight or to UV lights. • To get the best of our technology, we recommend you to download and install
the last firmware release. Please check our website. Detailed instructions are available at
Outdoor installations recommendations Des instructions détaillées sont disponibles sur 1
➢ Outdoor devices shall not encounter extreme weather such as torrential rains, Overvoltage El detalle de las instrucciones está disponible en
harvest rains, flooding. • IDEMIA recommends the Biometric devices to be protected with an external
➢ High humidity, direct sun exposure, frequent high temperature, outdoor careless accessory in order to avoid overvoltage on input wires or connectors of the
device. Typically, risks of overvoltage have been identified on external power
https://biometricdevices.idemia.com
uses may alter the durability of the terminal.
➢ When the terminal is exposed to such potential extreme conditions, IDEMIA management wire, POE connector and wiegand input wire.
recommends deploying an enclosure to protect the terminal and thus ensure a
long-lasting performance in the field. WARNING: Cleaning & Disinfection precautions
!
To clean the terminal, a dry cloth is recommended, especially the biometric
sensor.

To disinfect the terminal, moisten a non-abrasive wipe with the disinfectant


COPYRIGHT © 2021, IDEMIA 2
Windex® Multi-Surface (or similar product containing L-Lactic acid) or
hydrogen peroxide (<3%) and wipe the device’s surface and leave the surface The units are to be installed in accordance to the local authority having jurisdiction,
wet with disinfectant for at least 5 minutes. Any other practices (bleach, National Electrical Code and the manufactures installation instructions. CBLX M3x8
chlorine, soda, alcohol, quaternary ammonium etc) permanently damage and/
or negatively impact the performances of the device. Head office :
2, place Samuel de Champlain - 92400 Courbevoie

Regulatory, safety and environmental notices Status LED


11mm 69mm
VGA Camera
Products bearing the CE marking comply with one or more of the following
EU Directives as may be applicable: Optional Wi-Fi™
40mm min • EMC Directive 2014/30/EU. USB adaptor
10,5mm

• RED Directive 2014/53/EU. (plugged at the back of


the terminal)
• ROHS Directive 2011/65/EU.
• ECODESIGN Directive 2009/125/EC.
Compliance with these directives is assessed using applicable European Speaker Microphone
Harmonised Standards.
55mm

This symbol means Direct Current (DC)


The installation of this product should be made by a qualified service 5" WVGA USB host port
Person and should comply with all local regulations. touchscreen
It is strongly recommended to use a class II power supply at 12VDC 1A LCD
minimum or at 24VDC 500mA minimum in conformity with Safety Electrical
Low Voltage (SELV). The power supply cable length should not exceed 10
meters.
78mm

This system must be installed in accordance with the National Electrical


Code (NFPA 70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying with Optical
IEC60950-1, in accordance with the NEC Class 2 requirements; or supplied biometrical sensor
by a listed IEC60950-1 external Power Unit marked Class 2, Limited Power Optional Contactless Card reader.
source, or LPS and rated 12VDC, 1A minimum or 24VDC, 0,5A minimum. Specific logo on cover when available
For UL 294 Compliance, power supply must be UL294B or UL 294 Listed
Class 2 with a power limited output.
In case of building-to-building connection (power source in a building, and WR product comes
terminal in another building), it is recommended to connect the 0V of the with a sensor
Φ = 4mm power supply to the earthing system of the building. And the terminal block protection cap (not
Power Ground must be connected with the earthing system of the other
displayed here)
building.
Models:
Note that all connections of the MorphoAccess® SIGMA Series terminal MorphoAccess® Sigma iClass (MPH-AC003B)
described hereafter are of SELV (Safety Electrical Low Voltage) type. MorphoAccess® Sigma Multi (MPH-AC003B)
MorphoAccess® Sigma Prox (MPH-AC003A)
88mm MorphoAccess® Sigma (MPH-AC003C)
This symbol means do not dispose of your product with your other
household waste. Instead, you should protect human health and the UL294 Performance levels
environment by handing over your waste equipment to a designated Access
Destructive Stand-by
collection point for the recycling of waste electrical and electronic Control Line Endurance Conditions
Attack Power
Scale 1.0 equipment. Security
Level I Level I Level IV Level I NA
1 IP55*
* IP55 ratings are self-declared not evaluated by UL.
For UL compliance the Units are indoor rated products. 2 Wiring Overview Power Supply
RJ45
WARNING: Power Supply from electrical source shall be switched off before starting

USB
! the installation.
POE Before proceeding, make sure that the person in charge of installation and
connections, is properly connected to earth, in order to prevent Electrostatic
Discharges (ESD).

External Power supply: 12/24 VDC (regulated and filtered) 1A min @12VDC or
µSD 500mA min @24VDC, IEC 60950-1 standard compliant. A 12 Volts power supply
compliant with SIA's Wiegand standard will also be suitable. If sharing power between
devices, each unit must receive 1A (e.g. two units would require a 12 VDC, 2A supply).
For UL compliance the units shall be powered via a class 2 output from a UL 294
power supply.
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is
recommended.
25 WIEGAND_LEDOUT1 Blue Power Over Ethernet (POE): power can be provided through RJ-45 connector using a
26 WIEGAND_LEDOUT2 Blue / Red PSE (Power Sourcing Equipment) IEEE802.3af or IEEE802.3at type 1 compliant.
23 WIEGAND_IN1 White / Red
24 WIEGAND_OUT0 Green For UL compliance the units shall be powered via a UL 294B PSE power supply listed as
21 WIEGAND_OUT1 White a limited Power Source Unit. The PSE shall be rated min of 41-57VDC (-10% / +15%),
22 WIEGAND_IN0 Green / Red 1Amp.
20 WIEGAND_GND Black / Red
The terminal is a Class 0 (15.4 W) PD (Powered Device).
19 RS422/485_GND Black / Red Warning: after use, the temperature of the POE module may be high: after power
3 4 17 RS422_RX_A Blue / Black cut off, wait 5mn before working on connectors area.
18 RS422_TX_Z/RS485_Z Green / White

! 15
16
RS422_RX_B
RS422_TX_Y/RS485_Y
Blue / White
Green / Black
IDEMIA recommends using a Gauge AWG20 for 12V power supply.
The voltage measured on the product block connector of the terminal must be equal to
7 RLY_NC Orange / White 12V-24V (-15% / +10%).
5 RLY_NO Yellow / White The voltage drop due to the cable shall be taken into account. The table below shows
6 RLY_COM Grey / White
3 SWITCH_PIN1 Light Blue
the maximum voltage drop between the power source and the terminal, depending on
Relay output 30VDC, 2A.
4 SWITCH_PIN2 Pink the length of the cable.
Suitable for inductive and resistive 1 Power +12V Red
loads. Inductive load management 2 Power GND Black
requires a parallel diode for a better
Gauge Diameter Maximum drop voltage (V)
! contact lifetime.
Tamper 30VDC, 100 mA (Resistive).
13
14
11
GPI2
GPO2
GPI1
Orange / Black
Yellow / Black
Orange / Red
AWG (mm)
at 1m at 5m at 10m
12 GPO1 Yellow / Red 20 0.81 0.03 0.17 0.33
UL has not verified Wi-Fi Capabilities. 9 GPI0 Orange
10 GPO0 Yellow 22 0.64 0.05 0.26 0.53
Ethernet connection is for supplemental 8 GPIO_GND Black / Red 24 0.51 0.08 0.42 0.84
2 use not UL evaluated.
The input circuits are not evaluated for UL burglar alarm use

For UL installations only Wiegand is to be used. WARNING: Under powering may cause memory and data corruption; over
UL has not evaluated GPIO and RS422/485 communication. ! powering may cause hardware damage. Both of these situations will void
1 For UL 294 installation, length of communication (RS422-RS485/Wiegand) and I/Os the warranty.
(GPI/GPO) cables must not exceed 30 meters (98.4 feet).

5 6 7

(POE)
2
1

* IP65 ratings are self-declared not evaluated by UL.


8 9 10 IP65* For UL compliance the Units are indoor rated products.

(WR)