Professional Documents
Culture Documents
Sample Plan 1
Sample Plan 1
2 DELUGE VALVE
3 NOZZLE K25
A FIRE PUMP
B JOCKEY PUMP
SA-HV-1
SA-HV-2
CVT-1
DSE-1
DSE-3
DSE-2
DSE-4
DSE-5
DSE-6
DSE-7
CVT-2
CB-1
CB-2
CB-3
BS-1
BS-2
BS-4
BS-5
PTR
CIT
DS
C DIESEL TANK
G O.S.&Y VALVE
A
H CHECK VALVE 100 mm
80 mmø
X1
J FLOW METER
L CHECK VALVE 40 mm
2 M GATE VALVE
80 mmø
100 mmø
X1
4´
100 mmø
100 mmø
SA-HV-1
SA-HV-1
PTR
PTR
FPS-General Layout
SCALE 1 : 300
REVISION BOX
3 3 3
80 mmø
1
C
100 mmø
3 3 3
3
65 mmø
D
65 mmø
65 mmø
F ENGINE
A ASISTENCIAS TÉCNICAS DE INGENIERÍA
3 100 mmø G
F
X3
X3
B E L
100 mmø
X2
X2
3 G 40 mmø
3
LAGUNA WIND ENERGY CORP.
X1
X1
G K
3 3
80 mmø
3
100 mmø
3 B G
I H M J
65 mmø
65 mmø
65 mmø
65 mmø
PROJECT NAME
KALAYAAN 2 WIND POWER PROJECT
100 mmø
C
65 mmø
F Paete and Kalayaan, Laguna Province
65 mmø
3 3 3 3 3 3
N
TITLE KY2 SUBSTATION.
FIRE PROTECTION SYSTEM. GENERAL LAYOUT
DRAWING KY2-ATI-DED-CIV-DWG-3270
FPS - TR-1 LAYOUT DETAIL FPS - TR-2 LAYOUT DETAIL FPS - PUMP HOUSE LAYOUT FILE KY2-ATI-DED-CIV-DWG-3270-R0
YEAR / MONTH / DAY (YYYY-MM-DD)
SCALE 1 : 100 SCALE 1 : 100 SCALE 1 : 100 DESIGNED BY DRAWN BY CHECKED BY DATE 2023/09/26 SCALE Comoindicated
As se indica
TRANSFORMER FIRE
EE PROTECTION
C B A
WE STEEL PIPE SCHEDULE 40
2 DELUGE VALVE
NE NE
1.295 1.255 1.255 1.295 3 NOZZLE K25
3 1 5 5 6 5 5 6
4
1.084
45.
00°
45
.00
00°
45.
.0
45
0°
6 6
1.574
80
0° .0
.0
3 3 0°
0°
80
80
0.388
.0
6 6
.0
80
0°
3
65 mmø
3
3.502
3.502
3.502
1.462
65 mmø
1.928
65 mmø
X3
65 mmø
B 6 6
3
4 4
X2
X1
65 mmø 65 mmø
80 mmø
2.000
2.000
80 mmø
2.000
2.000
80 mmø
3 3 6 6 6
6 6 6 6 6 6
6
65 mmø
65 mmø
1.850
0.600
0.600
0.600
1
2
5 3 3 3 1
65 mmø 65 mmø
C
6 6 6
1.295 1.255 1.255 1.295
SE SE
WE
EE
FPS - TRANSFORMER DELUGE SYSTEM NORTH TR ELEVATION (NE) EAST TR ELEVATION (EE)
SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50
A B C
3 5
6
65 mmø
3
65 mmø
6
5 65
mm
ø
3
ø 65
65
mm 3 6 3
mm
ø 6 5 5 6 6 5 5 6
6
6 ø
45.
00°
mm 3
45
°
.00
6
00°
65
45.
.0
3
45
mø
0°
4 0°
5m 0° .0
1.574
1.574
6 65 .0 80
mm 80 80
3 ø .0
0° 80
3 6 .0
mø 3 0°
6 5m 3
3 3 3
3 6
80 mmø
3.502
3.502
65
mm
6 mø ø
6 5m
mm
ø
3 6
3 65
3 6
1
65 mmø
1.928
1.928
mø
3
65 mmø
5m
REVISION BOX
3
6 3
mø 65 mmø 65 mmø
6 5m 3 65
mm
6 6
ø 4 6
3 6 5m
mø 2
ø 6
6 mm
65
65 mmø 65 mmø
3 3
6 6 mm
ø
mm
ø
80 mmø
65
mm 3 65 80
2.000
2.000
2.000
2.000
ø 0 MJG MJG CAR 23/09/26 DETAILED DESIGN - INITIAL VERSION
65 3 6 6 6 6 6 6 6 REV DSN. DRN. CHK. DATE Y / M / D DESCRIPTION
mm
ø
mø
6 5m
1 65 mmø 65 mmø 65 mmø
0.600
0.600
0.600
0.600
65 mmø 65 mmø 80 mmø ASISTENCIAS TÉCNICAS DE INGENIERÍA
1
PROJECT NAME
KALAYAAN 2 WIND POWER PROJECT
SOUTH TR ELEVATION (SE) WEST TR ELEVATION (WE) Paete and Kalayaan, Laguna Province
SCALE 1 : 50 SCALE 1 : 50 N
TITLE KY2 SUBSTATION.
FIRE PROTECTION SYSTEM. DELUGE SYSTEM DETAILS
DRAWING KY2-ATI-DED-CIV-DWG-3270
FILE KY2-ATI-DED-CIV-DWG-3270-R0
YEAR / MONTH / DAY (YYYY-MM-DD)
DESIGNED BY DRAWN BY CHECKED BY DATE 2023/09/26 SCALE Comoindicated
As se indica
LEGEND
MAIN TRANSFORMER-1
GATE OR ISOLATING VALVES
DELUGE VALVE
D
MAIN PIPE (MPP) PIPE DN100
M Pmin=2.75 bar
PIPE DN65
Pmin=2.95 bar Fi=31.74 l/s Fi=15.87 l/s
v=3.86 m/s v=3.33 m/s D M PRESSURE GAUGE
PIPE DN80
NOZZLE K25
v=2.38 m/s
PIPE DN65
Fi=7.33 l/s
v=2.78 m/s
PIPE DN65
Fi=8.55 l/s
DRAINAGE
Fi=15.87 l/s
v=3.33 m/s
PIPE ∅80
FLOW SWITCH
MAIN TRANSFORMER-2
M Pmin=2.75 bar
PIPE DN65
Fi=15.87 l/s
v=3.33 m/s D
PIPE DN80
v=2.38 m/s
PIPE DN65
Fi=7.33 l/s
v=2.78 m/s
PIPE DN65
Fi=8.55 l/s
REVISION BOX
0 MJG MJG CAR 23/09/26 DETAILED DESIGN - INITIAL VERSION
REV DSN. DRN. CHK. DATE Y / M / D DESCRIPTION
PROJECT NAME
KALAYAAN 2 WIND POWER PROJECT
Paete and Kalayaan, Laguna Province
N
TITLE KY2 SUBSTATION.
FIRE PROTECTION SYSTEM. SCHEME
DRAWING KY2-ATI-DED-CIV-DWG-3270
FILE KY2-ATI-DED-CIV-DWG-3270-R0
YEAR / MONTH / DAY (YYYY-MM-DD)
DESIGNED BY DRAWN BY CHECKED BY DATE 2023/09/26 SCALE 1 : 1000