Load Bearing Wall Truss Specifications
Load Bearing Wall Truss Specifications
52-04-00
DO NOT ATTEMPT TO ERECT
28-04-00 24-00-00 TRUSSES WITHOUT REFERRING TO
THE ENGINEERING DRAWINGS AND
1-02-08
10-08
7-00-00 24" O.C 7-00-00
BSCI-B1 SUMMARY SHEETS.
CJ01
CJ03
CJ05
CJ5A
CJ3A
CJ01
RAFTER TAILS PLACED IN FIELD ALL PERMANENT BRACING MUST BE
IN PLACE PRIOR TO LOADING
1A
HJ
01
HJ
TRUSSES. (ie. SHEATHING,
U: 2720
U: 1003
U: 1309
U: 1303
U: 1323
U: 1127
U: 1312
U: 1323
U: 1323
U: 1138
U: 1127
U: 1323
2-00-00
CJ01 CJ01 SHINGLES, ETC.)
2 PLY A21
A20
A19
A18
A17
A16
A15
A14
A13
A12
A09
A08
A07
A06
A05
A04
A03
A02
2 PLY A01
A10
A11
ALL INTERIOR BEARING WALLS
7-08-00
SHEETS FOR THE FOLLOWING.
U: 1752
U: 3949
U: 1543
U: 1532
J01 J1C
1) NUMBER OF GIRDER PLIES AND
NAILING SCHEDULE.
COFFER CLG.
U: 1443
U: 1417
U: 1643
U: 1718
U: 1859
U: 1657
J01 J1B
2-00-00
11'-0" LOAD BEARING WALL 2) BEARING BLOCK REQUIREMENTS.
6-00-00
J01 J01 3) SCAB DETAILS (IF REQUIRED)
2-00-00
LOAD BEARING WALL
4) UPLIFT AND GRAVITY REACTIONS.
J01 J1A
5/12
J01 J1A
WARNING
Backcharges Will Not Be Accepted
Regardless of Fault Without Prior
13-04-00
J01 J1A Notification By Customer Within 48
COFFER CLG.
37-00-00
Hours And Investigation By
11'-0" ProBuild.
13-08-00
J01 J1A NO EXECPTIONS.
The General Contractor Is Responsible
44-00-00
J01 FLAT CLG. COFFER CLG. J1A For All Connections Other Than Truss
10'-0" 11'-0" to Truss, Gable Shear Wall, And
Connections. Temporay and
J01 J1A
Permanent Bracing, And Ceiling And
Roof Diaphram Connections.
51-06-00
J01 9-00-00 J01
5/12 5/12
5/12
SQ. OR PLB. CUT: PLUMB
J01 12'-8" 1-00-00 J01
HARDWARE
FLOOR ROOF
5-10-00
J01 COFFER CLG. J01 NONE <A> HTU26= 13
1-00-00
1-00-00
13'-8" <C> HTU26-2= 1
<D> HTU28-2= 2
U: 1181
U: 1161
U: 1368
J01 J01
VT04
12'-8" 1-00-00
A A A C U: 1388
J01
76-08-00
D02
D U: 2741 2 PLY C03
VT08
5/12 5/12 1-09-00 BEARING HEIGHT SCHEDULE
2x LEDGER BY OTHERS
VT03
J01 FLAT CLG. D02 A C02
Hatch Legend
VT09
5/12 5/12
14'-6"
VT02
24" O.C
EXPOSED TO WIND
J01 D02 A C02 11'-0"
FLAT CLG.
U: 1312
U: 1046
U: 1296
U: 1296
U: 2769
U: 1132
U: 1148
U: 1148
U: 1148
U: 1158
U: 1163
U: 1148
5/12
1-00-00 D
3-00-00
A A A A A A A
10'-0"
HJ
04
CJ1A
04
R: 10071
HJ
R: 7662 3 PLY B06
5-00-00
1-03-08 U: 6777
U: 5464 CJ3B CJ03
CJ1A VT07
BUILDER:
CJ1A
B04
CJ1A
CJ03
CJ03
J4A 5/12 5/12
J4A
J4A
J03
J03
J03
CJ01
B04
CJ01 F02 SANCHEZ ENTERPRISE
GROUP LLC PIA 760634
CJ01
CJ01
HJ
02
F01
02
HJ
3-06-00
3-00-00
B04 8-00-00 8-08-00
ADDRESS: 1040 15TH STREET SW
6-00-00 7-10-00 CJ01 CJ01
LOT: N/A
CJ01
CJ01
B05
HJ
03
J04
J04
SUB: NAPLES
03
HJ
6-08-00 COUNTY: COLLIER
B05
5/12 5/12 13-04-00 PROJECT:
8-00-00
A/C SED336
IN STORAGE B05
MODEL:
B05 SED336
30-08-00
30-03-08
CJ05 CJ05
VT06 MWFRS(Directional)/C-C HYBRID WIND ASCE7-16 / CODE FBC2020 IMPORTANT
7-00-00
ENCLOSED
5/12 5/12 This Drawing Must Be Approved And
CJ03
VT05
CJ03 EXPOSURE CATEGORY C
OCCUPANCY CATEGORY II Returned Before Fabrication Will
J2A
J2A
J02
J02
J02
J02
CJ03
CJ05
CJ03
CJ01
HJ
01
LIVE LOAD NONCONCURRENT WITH ANY OTHER LIVE LOADS SIGNATURE BELOW INDICATES ALL
01
HJ
2-00-00
CJ01 CJ01
NOTES AND DIMENSIONS HAVE
ROOF LOADING FLOOR LOADING BEEN ACCEPTED.
CJ01
CJ01
HJ
05
J05
J05
J05
05
HJ