You are on page 1of 3

QUOTE #

DATE 04/19/16

Q160225

REQ. QUOTE DATE


ORDER DATE
DELIVERY DATE
DATE OF INVOICE
ORDERED BY

/ /
/ /
/ /
/ /
Valued Customer

SUPERINTENDENT

Valued Customer

ORDER #
QUOTE #
CUSTOMER ACCT #
CUSTOMER PO #
INVOICE #
TERMS
SALES REP

S
H
I
P
T
O

JOB NAME: Steven Krahn

Counter Sales
One Time Customer
Winkler, MB

LOT #
TAG: Attic Truss

MODEL:

Q160225
000000007

Ryan McCracken

SALES AREA

JOBSITE PHONE #
S
O
L
D
T
O

PAGE 1

SUBDIV:

JOB CATEGORY:

DELIVERY INSTRUCTIONS:

SPECIAL INSTRUCTIONS:

Winkler, MB
BY

BUILDING DEPARTMENT OVERHANG INFO HEEL HEIGHT


END CUT
RETURN
Commercial
GABLE STUDS

PLUMB

LOADING
INFORMATION
PITCH
TYPE
ID
TOP
BOT

ROOF TRUSSES
PROFILE

QTY
PLY
16

8.00

01-00-00

FINK
A01

0.00

STRESS INCR.

28-00-00

ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)

1.33

41.0-5.0-0.0-7.0

O/A
SPAN

NONE

DATE
/ /
/ /
/ /

QUOTE
LAYOUT
CUTTING

REQ. ENGINEERING

NONE

0 IN. OC

TCLL-TCDL-BCLL-BCDL

BASE
SPAN

REQ. LAYOUTS

LUMBER

OVERHANG

CANTILEVER

TOP

LEFT

LEFT

BOT

RIGHT

RIGHT

STUB
LEFT

RIGHT

28-00-00 2 X 8 2 X 10 01-10-08 01-10-08

ITEMS
QTY

ITEM TYPE

SIZE

LENGTH
FT-IN-16

32

Hanger

PART NUMBER

NOTES

One RT7A

NOTE:

ACCEPTED BY BUYER

Quote derived from information supplied by parties quoted.

PURCHASER:

Verification of design, layout (if included), and building location


are the responsibility of the quoted party prior to acceptance of quote

BY:

Changes to the information herein are subject to re-quote and


price adjustments, if necessary.

ADDRESS:

SUB-TOTAL

TITLE:

DELIVERY

$65.00

SUB-TOTAL

$3,309.32

SALES TAX

Quotation valid for 15 days only

PHONE:

DATE:

$3,244.32

*.*** %

GRAND TOTAL

$430.22

$3,739.54

JOB NAME

TRUSS NAME

Q160225

QUANTITY

A01

16

PLY

JOB DESC.

TRUSS DESC.

DRWG NO.

Clearspan Truss, Winkler

Version 8.000 S Feb 26 2016 MiTek Industries, Inc. Tue Apr 19 15:38:23 2016 Page 1

ID:?A6iynnnhz0SFR?955bL2TzP6bD-JBBJQlieRDXWK6Z2y9rx5bZ5aBqpZZKKktat85zP6R_
-1-10-8
0-0
1-10-8

4-2-14

4-2-14

7-10-4

3-7-6

4-1-9

11-11-13 12-0-3 13-2-6 14-0-0 14-9-10 16-0-3 20-1-12


0-6 1-2-3 9-10 9-10 1-2-9
4-1-9
3-7-6

23-9-2

28-0-0 29-10-8
1-10-8

4-2-14

Scale = 1:62.8
6x7
5x12 MT18HS

5x12 MT18HS

E
W4

3.5x5

3.5x5
H
8-1-14

11-3-11
10-4-0

D
T1

4x5

T1

4x5
I

C
W3
R

W3

W2

W1

W2

W1

1-0-0

B
B1

B2

A
P

Q
6x6

LUMBER
N. L. G. A. RULES
CHORDS
SIZE
A - F
2x8
F - K
2x8
B - N
2x10
N - J
2x10
E - G
2x4

DRY
DRY
DRY
DRY
DRY

PLATES (table is in inches)


JT TYPE
PLATES
B TMB1-l
MT20
C TMWW-t
MT20
D TMW+w
MT20
E TMW+w
MT18HS
F TT+p
MT20
G TMW+w
MT18HS
H TMW+w
MT20
I
TMWW-t
MT20
J TMB1-l
MT20
L BMW+w
MT20
M BMWW+t
MT20
N BS-t
MT20
O BMWW+t
MT20
P BMW+w
MT20

DESCR.
DF
DF
SPF
SPF
SPF

No.2

W
6.0
4.0
3.5
5.0
6.0
5.0
3.5
4.0
6.0
2.0
6.0
8.0
6.0
2.0

LEN
6.0
5.0
5.0
12.0
7.0
12.0
5.0
5.0
6.0
5.0
8.0
10.0
8.0
5.0

8x10

6x8

4-2-14

4-2-14

LUMBER
1950F 1.7E
1950F 1.7E
No.2
No.2
No.2

ALL WEBS 2x4


DRY
DRY: SEASONED LUMBER.

2x5

0-0

3-7-6

7-10-4

L
2x5

20-1-12

12-3-8

DIMENSIONS, SUPPORTS
DESIGNER
BEARINGS
FACTORED
GROSS REACTION
JT
VERT
HORZ
B
2977
0
J
2977
0

M
6x8

3-7-6

1-0-0

8.00 12

S
6x6

23-9-2

28-0-0

4-2-14

TOTAL WEIGHT = 16 X 222 = 3552 lb


[M]

AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY BUILDING


DESIGN CRITERIA
MAXIMUM FACTORED
GROSS REACTION
DOWN HORZ UPLIFT
2977
-442
-485
2977
0
-485

INPUT
BRG
IN-SX
5-8
5-8

REQRD
BRG
IN-SX
3-4
3-4

SPECIFIED LOADS:
TOP CH. LL = 37.6
DL =
5.0
BOT CH. LL =
0.0
DL =
7.0
TOTAL LOAD = 49.5

PSF
PSF
PSF (*)
PSF
PSF

One RT7A USP CONNECTOR(S) RECOMMENDED TO CONNECT TRUSS FOR UPLIFT AT JOINT(S) B AND J.
THIS CONNECTION IS FOR UPLIFT ONLY AND DOES NOT CONSIDER LATERAL FORCES.

ATTIC FLOOR
=
DL =
CEILING
DL =

PSF
PSF
PSF

PROVIDE FOR 442 LBS FACTORED HORIZONTAL REACTION AT JOINT B

SPACING =

UNFACTORED REACTIONS
1ST LCASE
MAX./MIN. COMPONENT REACTIONS
JT
COMBINED
SNOW
LIVE
PERM.LIVE
WIND
B
2239
1205 / 0
492 / 0
0/0
254 / -695
J
2239
1205 / 0
492 / 0
0/0
254 / -695

THIS TRUSS IS DESIGNED FOR COMMERCIAL OR


INDUSTRIAL BUILDING REQUIREMENTS OF PART 4,
NBCC 2010

SPF

Y
3.00
2.25
2.50
6.00
Edge
6.00
2.50
2.25
3.00

X
2.75
2.00
1.50
1.75
3.00
1.75
1.50
2.00
2.75

5.00 3.00
5.00 3.00

HORIZONTAL REACTIONS
B
--0/0

0/0

0/0

316 / -316

DEAD
542 / 0
542 / 0

SOIL
0/0
0/0

0/0

0 /0

BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) B, J


BRACING
MAX. UNBRACED TOP CHORD LENGTH = 4.61 FT.
MAX. UNBRACED BOTTOM CHORD LENGTH = 6.25 FT. OR RIGID CEILING DIRECTLY APPLIED.
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED.

Edge - INDICATES REFERENCE CORNER OF PLATE TOUCHES


EDGE OF CHORD.

LOADING
TOTAL LOAD CASES: (18)
CHORDS
MAX. FACTORED
MEMB.
FORCE
(LBS)
FR-TO
A- B
0 / 73
B- R
-4795 / 481
R- C
-3910 / 563
C- D
-3727 / 428
D- E
-2509 / 477
E- F
-357 / 2755
F- G
-358 / 2755
G- H
-2509 / 476
H- I
-3727 / 427
I- T
-3910 / 569
T- J
-4795 / 488
J- K
0 / 73
B- Q
Q- P
P- O
O- N
N- M
M- L
L- S
S- J
E- G

-582 / 3311
-582 / 3311
-582 / 3311
-112 / 2665
-112 / 2665
-293 / 3311
-293 / 3311
-293 / 3311
-6031 / 938

WEBS
FACTORED
MAX. FACTORED
VERT. LOAD LC1 MAX MAX.
MEMB.
FORCE
MAX
(PLF)
CSI (LC) UNBRAC
(LBS)
CSI (LC)
FROM TO
LENGTH FR-TO
-125.1 -125.1 0.07 (2) 10.00 M- H
0 / 1840
0.30 (4)
-125.1 -125.1 0.05 (2)
5.27
M- I -1382 / 621
0.32 (3)
-125.1 -125.1 0.15 (2)
5.58
L- I
-954 / 167
0.12 (2)
-125.1 -125.1 0.71 (1)
4.61 O- D
0 / 1840
0.30 (4)
-137.6 -137.6 0.72 (1)
5.35 C- O -1382 / 614
0.32 (2)
-125.1 -125.1 0.82 (1)
6.25 P- C -954 / 169
0.12 (3)
-125.1 -125.1 0.82 (1)
6.25 Q- R
0 / 1125
0.00 (1)
-137.6 -137.6 0.72 (1)
5.35
S- T
0 / 1125
0.00 (1)
-125.1 -125.1 0.71 (1)
4.61
-125.1 -125.1 0.15 (3)
5.58
-125.1 -125.1 0.05 (3)
5.27
-125.1 -125.1 0.07 (3) 10.00
-17.5 -17.5 0.41 (1)
-17.5 -17.5 0.47 (1)
-17.5 -17.5 0.75 (3)
-122.5 -122.5 0.78 (4)
-122.5 -122.5 0.78 (4)
-17.5 -17.5 0.75 (2)
-17.5 -17.5 0.47 (1)
-17.5 -17.5 0.41 (1)
-12.5 -12.5 0.40 (1)

6.25
6.25
6.25
6.25
6.25
6.25
6.25
6.25
2.60

24.0

40.0
10.0
5.0

IN. C/C

THIS DESIGN COMPLIES WITH:


- PART 4 OF OBC 2012 , BCBC 2012 , ABC 2014
- CSA 086-09
- TPIC 2011
(*)- BC LL SPECIFIED BY FABRICATOR, DOES NOT
COMPLY WITH NBC TABLE 4.1.5.3. LOADING TO BE
VERIFIED BY BUILDING DESIGNER
DESIGN ASSUMPTIONS
- SLOPE REDUCTION FACTOR USED
(73 % OF 46.0 P.S.F. G.S.L. PLUS 4.2 P.S.F. RAIN
LOAD) TIMES IMPORTANCE FACTOR EQUALS 37.6
P.S.F. SPECIFIED ROOF LIVE LOAD
ALLOWABLE DEFL.(LL)= L/360 (0.93")
CALCULATED VERT. DEFL.(LL) = L/ 609 (0.55")
ALLOWABLE DEFL.(TL)= L/360 (0.93")
CALCULATED VERT. DEFL.(TL) = L/ 438 (0.77")
CSI: TC=0.82 (F-G:1) , BC=0.78 (M-O:4) , WB=0.40 (E-G:1)
, SSI=0.85 (F-G:1)
DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
COMP=1.10 SHEAR=1.10 TENS= 1.10
SNOW LOAD IMPORTANCE FACTOR = 1.00
WIND LOAD IMPORTANCE FACTOR = 1.00
LIVE LOAD IMPORTANCE FACTOR = 1.00
COMPANION LIVE LOAD FACTOR = 1.00
TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .
NAIL VALUES
PLATE GRIP(DRY) SHEAR
(PSI)
(PLI)
MAX MIN MAX MIN
MT20
618 354 1667 822
MT18HS 580 354 2729 1405

SECTION
(PLI)
MAX MIN
2284 1656
4191 2010

PLATE PLACEMENT TOL. = 0.250 inches


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8)
WIND LOAD APPLIED IS DERIVED FROM REFERENCE VELOCITY PRESSURE OF {10.9} PSF AT {20-0-0}
FT-IN-SX REFERENCE HEIGHT ABOVE GRADE AND USING EXTERNAL PEAK COEFFICIENTS, CpCg, BASED
ON THE {MAIN WIND FORCE RESISTING SYSTEM}.INTERNAL WIND PRESSURE IS BASED ON DESIGN
{CATEGORY 2}. BUILDING MAY BE LOCATED ON {OPEN TERRAIN}, AND TRUSS IS DESIGNED TO BE
LOCATED AT LEAST {0-0} FT-IN-SX AWAY FROM EAVE.

PLATE ROTATION TOL. = 5.0 Deg.


JSI GRIP= 0.86 (B) (INPUT = 0.90 )
JSI METAL= 0.74 (J) (INPUT = 1.00 )

QUOTE #

DATE 04/19/16

Q160225

REQ. QUOTE DATE


ORDER DATE
DELIVERY DATE
DATE OF INVOICE
ORDERED BY

/ /
/ /
/ /
/ /
Valued Customer

SUPERINTENDENT

Valued Customer

ORDER #
QUOTE #
CUSTOMER ACCT #
CUSTOMER PO #
INVOICE #
TERMS
SALES REP

S
H
I
P
T
O

JOB NAME: Steven Krahn

Counter Sales
One Time Customer
Winkler, MB

LOT #
TAG: Common Option

MODEL:

Q160225
000000007

Ryan McCracken

SALES AREA

JOBSITE PHONE #
S
O
L
D
T
O

PAGE 1

SUBDIV:

JOB CATEGORY:

DELIVERY INSTRUCTIONS:

SPECIAL INSTRUCTIONS:

Winkler, MB
BY

BUILDING DEPARTMENT OVERHANG INFO HEEL HEIGHT


END CUT
RETURN
Residential
GABLE STUDS

PLUMB

LOADING
INFORMATION
PITCH
TYPE
ID
TOP
BOT

ROOF TRUSSES
PROFILE

QTY
PLY
14
2

6.00
6.00

00-07-07
24 IN. OC

TCLL-TCDL-BCLL-BCDL

STRESS INCR.

1.33

29.5-4.0-0.0-7.0

BASE
SPAN

REQ. LAYOUTS

O/A
SPAN

NONE

NONE

ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)

LUMBER

OVERHANG

CANTILEVER

TOP

LEFT

LEFT

BOT

RIGHT

0.00

FINK
T01

28-00-00

28-00-00 2 X 4 2 X 4 01-10-08 01-10-08

0.00

GABLE
T01GE

28-00-00

28-00-00 2 X 4 2 X 4

NOTE:

ACCEPTED BY BUYER

Quote derived from information supplied by parties quoted.

PURCHASER:

Verification of design, layout (if included), and building location


are the responsibility of the quoted party prior to acceptance of quote

BY:

Changes to the information herein are subject to re-quote and


price adjustments, if necessary.

ADDRESS:

RIGHT

STUB
LEFT

RIGHT

SUB-TOTAL

TITLE:

PHONE:

DATE:

$1,776.58

DELIVERY

$65.00

SUB-TOTAL

$1,841.58

SALES TAX

Quotation valid for 15 days only

DATE
/ /
/ /
/ /

QUOTE
LAYOUT
CUTTING

REQ. ENGINEERING

*.*** %

GRAND TOTAL

$239.41

$2,080.99

You might also like