Professional Documents
Culture Documents
DC-70 Specification Ver 1.0 20140808
DC-70 Specification Ver 1.0 20140808
DC-70
Color Doppler Ultrasound System
Specification
Release V1.0
1
Mindray Confidential
Version 1.0 AUG. 2014
Power Doppler Imaging and
1 System Overview Directional PDI
1.1 Application Pulsed Wave Doppler
TM
Abdomen iBeam (Spatial Compound Imaging)
TM
Obstetrics iClear (Speckle Suppression
Gynecology Imaging)
TM
Cardiology iTouch (Auto Image Optimization)
TM
Small parts Echo Boost
Pediatrics B steer
Imaging) iStorage
M-Mode iLive
TM
Color M Mode Smart-V (Smart Volume)
Color Doppler Imaging Auto IMT
2
Mindray Confidential
Version 1.0 AUG. 2014
Elastography no batteries) (battery weight: 1.03Kg)
TDI (Include TVI, TVD, TVM, TEI) 2.2 Monitor
TDI QA (TDI Quantitative Analysis, 19-inch high resolution color LED
3
Mindray Confidential
Version 1.0 AUG. 2014
(receiving) Digital brightness and contrast
2.8 Operating Environment adjustment through preset
Ambient temperature: 0-40 °C Viewing angle: 140 degrees left/right;
700hPa-1060hPa screen.
2.9 Storage & Transportation Environment 3.3 Support touch gestures
Ambient temperature: -20-55 °C Image mapping on touch screen
700hPa-1060hPa Measurement
Zoom in/out
4
Mindray Confidential
Version 1.0 AUG. 2014
- Tissue thermal index Persistence
- ID, Last name, First Name, Middle Horizontal Scale
HPen/HGen/HRes/HPen-Gen (depends
4 Imaging Parameters on probe)
4.1 Overview 4.4 M-mode
Echo-enriched Beamforming Display formats
ExFOV Up to 3 lines
5
Mindray Confidential
Version 1.0 AUG. 2014
Gray Map B/C align
Edit, undo, delete function for curved Priority
Gain PW Scale
Scale Baseline
Baseline PW Steer
PRF PW PRF
Smooth Baseline
6
Mindray Confidential
Version 1.0 AUG. 2014
Wall filter - Acquisition Method: Wobble, Linear
Packet size - iClear
Tissue state - Acquisition mode: B, Color,Power
Smooth - VR
B/C align - MPR
Priority - Display formats
TVI maps - VOI
TEI maps - Reset
Invert - Active quadrant
Persistence - VR orientation
Velocity tag (TVI only) - Inversion
Line density - Accept VOI
4.11 Tissue Velocity Doppler(included in - Flip
TDI option) - Sync
Available on phased array transducer - Render modes
Display formats - View direction
Sample volume size - Threshold
Sample gate depth - Opacity
Scale - Smooth
Baseline - Brightness
Volume - Contrast
PRF - Tint
Gain Auto rotation
7
Mindray Confidential
Version 1.0 AUG. 2014
- View direction - Active Quadrant
- Threshold - Slice/Niche
- Opacity - Niche Views
- Smooth iLive
- Brightness - Shading
- Contrast - Move Light
- Tint - Light Position
- Free View - Render Modes
Color 3D - Soft View
- Supports Color and Power mode - Grad View
- Available in both Smart 3D and Auto rotation
- Rotate RL Ruler
8
Mindray Confidential
Version 1.0 AUG. 2014
throughout whole field LV volume measurement
Stress indicator: supports frame by - Measurement of LV Volume in all
frame stress indication. phases of cardiac cycle
Display format Report
Elasto Map - Reporting for both Wall Motion
Smooth Scoring and LV volume
Invert measurement
Opacity 4.18 iBeamTM
4.17 Stress Echo(option) Spatial compound imaging
Available on cardiac sector 9 angles maximum
transducers Available on all convex and linear
14 factory protocols transducers
User-defined protocols 4.19 iClearTM
ECG triggered acquisition, display, Speckle suppression imaging
selection, comparison, evaluation and Available for B, 3D, 4D
archiving of multiple cardiac loops 4.20 iTouchTM
during various stages of a stress echo Auto image optimization
examination B-mode
ASE 16 (with score 4-7), ASE 17 (with Color
score 4-7) Power
Customized stages: up to 6 views per PW
stage, and up to 12 stages per study 4.21 Echo BoostTM
View: standard views (PSLA, PSAX, Only for cardiac exams
A4C, A2C), and customized views improve the homogeneity of cardiac
Image acquisition images through the whole field of
- R-wave trigger view
- Acquire mode: Manual ROI or full Better contrast resolution of
screen myocardium tissue layers
- Ability to acquire frames or clips in Better noise control in cardiac
B-mode, M-mode, Color, PW and chambers and muscles
TDI 4.22 B steer
Image selection Only for linear transducers
- Attach the images with view 4.23 ExFov
annotation label (PSLA, PSAX, A4C, Extended field of view
A2C, and customized views) Available for all convex, linear and
Review volume transducers
- Automatically adjust to the number 4.24 Zoom
of images user defined Zoom: Spot zoom (write zoom) up to
Wall Motion Scoring 10x, Pan zoom (read zoom) 0.8-10
- ASE 16 (with score 4-7), or ASE 17 iZoom: convertible 3 steps ;normal
(with score 4-7) image, zoom standard area, zoom
- Graphical display of scoring (Normal, only image area
Hyperkinetic, Severely Hyperkinetic, 4.25 QSave
Akinetic, Dyskinetic) Quick save image parameter setting
9
Mindray Confidential
Version 1.0 AUG. 2014
after image adjustment done dual format and allows frame by
Support Save, Save as, Restore frame compare side by side
4.26 TDI QA (option) Image/cine compare: max 4 for
Std.Height TGC
Std.Width Gain
Std.Angle Dyn Ra.
Export Gray Map
4.27 iNeedle (option) Tint Map
Needle visualization enhancement iClear
Available on all linear transducers L/R Flip
Needle steer U/D Flip
4.28 iScanHelper Rotation
Tutorial function as a guidance to LGC
show basic scanning skill with graphic Dual Live
of probe position, schematic of Auto Merge
anatomy and example clinical image H Scale
Support ABD, SMP, URO applications Echo Boost
M-mode:
5 Cine Review and Raw Data Gain
Speed
Processing Dyn Ra.
5.1 Cine review Gray Map
Available in all modes Tint Map
Frame by frame manual cineloop Edge Enhance
review or auto playback with variable Color:
speed Gain
Maximum cine memory up to 64693 Baseline
frames or 60s (B) or 201.88s (M/PW) Smooth
Maximum 4D cine memory up to Color Map
54820 frames or 65s Priority
Retrospective and prospective storage Dual Live
are available and length is Invert
pre-settable (Max. time 480s, Max. Velocity tag
frames: 480030 ) B display only
Frame compare: displays one cine in PW:
10
Mindray Confidential
Version 1.0 AUG. 2014
Gain - Velocity
Baseline Doppler mode
Volume - D Velocity
Angle - Time
Speed - Heart Rate
Dyn Ra. - Acceleration
Gray Map - D Trace
Tint Map - PS/ED
Invert - Volume Flow
WF Automatic Doppler Spectrum Analysis
- Liver
Report* - Common Hepatic Duct
6.1 Generic measurements - Portal Vein Diameter
2D-mode - Gall Bladder: Length, Height, Wall
- Depth Thickness
- Distance - Common Bile Duct
- Area: Ellipse, Trace, Spline, Cross - Pancreas: Head, Body, Tail, Duct
- Trace Length - Spleen
- Double Distance - Left/Right Kidney: Length, Width,
- Parallel Height, Volume, Cortical Thickness
- Volume :3-Distance, Ellipse, Ellipse + - Left/Right Adrenal Gland: Length,
Distance) Width, Height
- Length Ratio - Abdominal Aorta Diameter
- Area Ratio - Abdominal Aorta Bifurcate Diameter
- IMT - Iliac Diameter
- B Histogram - Bladder: Length, Width, Height,
- B Profile Volume, micturition volume
- Volume Flow - Common Hepatic Artery
- Color Velocity - Hepatic Artery
M-mode - Portal Vein, Main Portal Vein
- Distance - Hepatic Vein, Left Hepatic Vein,
- Time Middle Hepatic Vein, Right Hepatic
- Slope Vein
- Heart Rate - Splenic Artery
11
Mindray Confidential
Version 1.0 AUG. 2014
- Splenic Vein Cardiology
- Left/Right Renal Artery, Main Renal - LV Function: Teichholz, Cube, Gibson,
Artery, Renal Artery Origin, Arcuate Simpson Single-plane, Simpson
Artery, Segmental Artery, Interlobar Bi-plane, Modified Simpson, Bullet,
Artery, Renal Vein S-P Ellipse, B-P Ellipse
- Abdominal Aorta - Auto LV: auto measurement in
- Celiac Axis Simpson method
- Superior Mesenteric Artery - LV Mass: Area-Length Method,
- Inferior Vena Cava Truncated-Ellipsoid Method, Cube
- Superior Mesenteric Vein Method
Gynecology - Atrial Volume: LA Vol(A-L), LA
- Cervix: Length, Width, Width Vol(Simpson), RA Vol(Simpson)
- Uterus: Length, Width, Height, - LVIMP
Volume, Uterus body, Endometrium - LV TEI, RV TEI
Thickness - Qp/Qs
- UT-L/CX-L - PISA MR, AR, TR, PR
- Ovary: Length, Width, Height, - MVA(VTI), AVA(VTI)
Volume - MV medial/lateral (TDI)
- Follicle: Length, Width, Height, Urology
Average Diameter, Volume - Prostate: Length, Width, Height,
Obstetrics Volume
- Early OB: GS, YS, CRL, BPD, FL, NT, - PPSA, PSAD
Amniotic Fluid - Ureter Diameter
- 2nd- 3rd Trimester: BPD, HC, OFD, - Bladder: Length, Width, Height,
FL, AC, AF, NF, PL Thickness, TAD, Volume, micturition volume
APAD, TCD, Cisterna Magna, HW, - Left/Right Kidney: Length, Width,
OOD, IOD, Orbit, HUM, Ulna, RAD, Height, Volume, Cortical Thickness
Tibia, FIB, CLAV, Vertebrae, MP, Foot, - Left/Right Adrenal Gland: Length,
Ear, APTD, TTD, FTA, THD, HrtC, TC, Width, Height
Umb VD, F-Kidney, Mat Kidney, - Left/Right Testis: Length, Width,
Cervix L(Trace available) Height
- Fetal Heart: LVIDd, LVIDs, LV Diam, - Left/Right Seminal Vesicle: Length,
LA Diam, RVIDd, RVIDs, RV Diam, Width, Height
RA Diam, IVSd, IVSs, IVS, LV Area, Vascular
RV Area, RA Area, Ao Diam, MPA - Carotid: CCA, ECA, ICA, Bulb, Vert A,
Diam, LVOT Diam, RVOT Diam, Subclav A
- Gestational Age - Upper Extremity Artery: Subclav A,
- Fetal Growth Axill A, Brachial A, Radial A, Ulnar A,
- Fetal Trend Graph Innom A
- Estimated Fetal Weight - Upper Extremity Vein: Cephalic V,
- Multi-gestational Calculations Basilic V, Ulnar V, Radial V
- Fetal Biophysical Profile - Lower Extremity Artery: CFA, SFA,
- User definable OB tables Pop A, TP Trunk A, Peroneal A, P.TIb
- Z-score A, A.Tib A, Dors. Ped A,
12
Mindray Confidential
Version 1.0 AUG. 2014
- Lower Extremity Vein: C.Iliac V, Auto detection of NT inside ROI
Ex.Iliac V, Femoral V, Saph V, Pop V,
TP Trunk V, Sural V, Soleal V, * Not all measurements are listed in this part;
Peroneal V, P.Tib V, A.Tib V For more detailed information please refer
- TCD (Transcranial Doppler): ACA, to User Manual
MCA, PCA, Basilar, A Comb.A, P
Comb.A, Vertebral A, Basilar A
Small Parts:
7 Exam Storage and Management
- Thyroid: Length, Height, Width, 7.1 Exam storage
Volume 320G hard drive. More than 242 GB
application exam
User-defined report template New exam, Active exam, Continue
by user available
6.6 Smart NTTM
NT auto measurement
8 Connectivity
13
Mindray Confidential
Version 1.0 AUG. 2014
8.1 Ethernet Network Connection 8.5 MedTouch
Cable connection Connect Ultrasound machine to smart
supported)
DICOM Query/Retrieve (option)
9 Transducers
DICOM Modality Performed 9.1 Curved array
Procedure Step - MPPS (option) C5-2E
14
Mindray Confidential
Version 1.0 AUG. 2014
- Biopsy Guide: NGB-018, multi angle, - Bandwidth: 3-13.5MHz
reusable - Field of View (max): 38mm
V11-3E - Physical Footprint: 45.7mm ×
- Application: OB/GYN, Urology 10.9mm
- Bandwidth: 2.6-12.8MHz - Footprint: 44.2mm × 8.5mm
- Convex Radius: 11mm - Biopsy Guide: NGB-007, multi angle,
- Footprint: 24mm × 9mm reusable
- Biopsy Guide: NGB-004, single L14-6NE
15
Mindray Confidential
Version 1.0 AUG. 2014
- Physical Footprint: 34 mm×24.5 mm Sweep speed: 1-6, 1/step
- Footprint: 21mm*13.8mm 10.8 Barcode reader
- Biopsy Guide: not available Laser barcode scanner
×11.3mm 12s
Full battery lasts more than 24h in
standby mode
10 Peripheral Devices and Light indicator for standby mode
Switch: on/off
16
Mindray Confidential
Version 1.0 AUG. 2014
EN ISO 17664 and ISO 17664
NOTICE:
Not all features or specifications described
in this document may be available in all
probes and/or modes.
Mindray reserves the right to make
changes in specifications and features
shown herein, or discontinue the product
at any time without notice or obligation.
Contact Mindray Representative for the
most current information
17
Mindray Confidential
Version 1.0 AUG. 2014