You are on page 1of 56

Filtration Products

Vickers
Filtration Master
Catalogue
LV2P Series
LV2P Series Pressure
Pressure 110
110
MODELPAGE MODELPAGE
Flows to:
Flows to: 110
110 L/min
L/min (29
(29 USgpm)
USgpm)
Fluid Analysis
Eaton Fluid Analysis Service
Pressures to:
Pressures to: 100
100 bar
bar (1,500
(1,500 psi)
psi)
Elements: V051...series
V051...series
Critical Analysis Clear Benefits
Eaton hydraulic components have a global reputation
for quality, reliability and performance. That reputation
is built on a tradition of customer service and we
Fluid is the lifeblood of every
hydraulic power system. To
keep yours running
We offer testing designed to
tell you the most about your
hydraulic fluid. We use Elements: 111
111
Fluid Analysis Pressure Filters
efficiently and effectively, sophisticated computer
stand behind every one of our products.
Breathers
Our Fluid Analysis Service follows that same tradition.
you need to know what’s in
it. What you don’t know can
programs and laboratory
diagnostic equipment such
hurt you. as an Energy Dispersive
We provide our customers with comprehensive fluid
The Eaton Fluid Analysis X-ray Fluorescence and an
testing and diagnostic services, with detailed reports inductively coupled plasma
that are easy to understand. Service analyzes hydraulic
spectrophotometer.

LV4PSeries
SeriesPressure
Pressure 113
fluid in much the same way
To find out how theH2O-gate™
Eaton Fluid
Analysis Service can help your
operation, read on.
Reservoir Breather
a medical lab tests a blood
Fluid Analysis
sample. Just as a blood test
helps a doctor diagnose
Features/Benefits:
health problems, a sample of
After we use this advanced
equipment to provide the
most• detailed
Media possible
contains oil
analysis of your hydraulic
Part Numbers:
9 ECF
LV4P Series Pressure 34
113
Flows to: 110 L/min (29 USgpm)
• Visual Mechanical attractant layerthat
to collect

Flows
Flows to:
to: 19
110L/min (5(29
USgpm)
Then call us to hydraulic fluid can help fluid, we create reports

L/min USgpm)
us pinpointActuates
sources of when and return
are always oil splashes.
easy to read and
H20-gate BR110
get started. Indicator:
contamination and determine understand. By taking the Bayonet Adapter 924710
particles have blocked the • Easyout Installation:

Pressures to: 100 bar (1,500 psi)


whether or not your system mystery of fluid analysis, Screw-in Adapter P-077002
media, beforefiltration.
the pump Lightweight
a service design can

Pressures to: 100 bar (1,500 psi)


uses adequate we provide that
cavitates.
We can help you reduce clearlybe handthe
explains tightened
benefits onto
Pressures to: 207 bar (3,000 psi) 35
Elements: V051...series
V051...series
of clean fluid.
adapter.
114
catastrophic equipment
• Proprietary Media:

Elements: 114
failures, maintain optimum
A Name You Trust Reduces
componentdew point
performance, • Durable Plastic Housing:
Only one fluid analysis lab lets you put years of Eaton temperature
and identify anytosubstandard
prevent Protects the media from
experience to work for you. So when the health of condensation and is Your
maintenance practices. external splashing.

Breathers
your hydraulic system is at stake, choose a partner bottom-line
99.7% benefitinis blocking
efficient
with more than 75 years of experience. Contact your increased productivity. • Superior breather filters
Eaton representative for more information on our Fluid
particles 3µ and larger. both moisture and
Analysis Service. • Reversible Flow Through particles from air.
Media: Allows for

HF2P
HF2P Series In Line
Lineand
andSubplate
Subplate  36
• Effective up to 121°C

Series In Line and Subplate 116


Comprehensive Testing Viscosity (ASTM D445): moisture
and degrades to exit the
equipment if any, (250°F)
are needed. The lab

BR110 Breather  13 HF2P Series 116


We use this test to determine reservoir.
performance. is also capable of testing to
The Eaton Fluid Analysis the viscosity of your oil. the•new Rated up to 25 SCFM
ISO 4406(1999)
Service is certified to ISO Drawdown Particle
Without proper hydraulic fluid Isolation: Using this test, standard (4µ, 6µ,14µ).

Flowsto:
to:90
90L/min
L/min(24(24USgpm)
USgpm)
12025 and offers a full range

Flows
viscosity, your equipment will we determine the insoluble Spectrometric Analysis
of tests specifically designed

Flows to: 90 L/min (24 USgpm)


suffer. Incorrect viscosity

Filters out moisture and particles from incoming air


for the analysis of hydraulic contaminates in hydraulic (ASTM D 5185): This shows
leads to fluid breakdown, fluids, both insoluble us the concentration of oil-
and lubrication system Dirt-gate™
fluid. Reservoir
equipment Breather

Pressuresto: to:280
280bar
bar(4,000
(4,000psi)
psi)
inefficient particles and gel-like matter, soluble elements and

Pressures
Our laboratory equipment operation, premature system

Pressures to: 280 bar (4,000 psi)


and test procedures provide organics and inorganics. indicates the additives and
failure and damage to other Features/Benefits:
Used in conjunction with trace metal content in the Part Numbers:
an exact analysis of your components. photomicrography,
Mechanicalthe fluids. We use this technique

Elements:V304...series
V304...series
hydraulic or oil lubricated • Visual • Durable Plastic Housing:
system, and our drawdown
particle isolation procedure
ensures accurate results.
drawdown patch helps us
Indicator:
identify theActuates
particles
source andwhen
have blocked the
of fluid contaminants.
media, before theCount
type

pump
to evaluate the condition
of the Protects
additives inthe
rather external
media from
a fluid
splashing.
than its particulate
contamination. Used in
Dirt-gate
Bayonet Adapter
Screw-in Adapter
BR210
924710
P-077002 Elements:
Elements: V304...series 117
37
117
Automatic Particle • High Efficiency:
Our testing procedures cavitates.
(ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle(99% at 2it helps
counting, microns)
us
• Easy Installation:
a photo sensor to count the accurately assess the
• Very Low Pressure Drop Note:
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter Lightweight
number and size design can
of particles
• Filters out particles This breather does not filter

BR210 Breather  13
patch using an optical be hand
in the fluidtightened
sample andonto
then Energy Dispersive X-ray
define contaminants
adapter. Fluorescence (ASTM E moisture from air.

MF2P Series Pressure 119


microscope to find particle • Effective up to 121°C
size and type. The scanning according to size distribution 1508): We perform Energy

MF2P Series
Series Pressure 119
Water (ASTM E203): We and quantities. Automatic (250°F)
Dispersive X-ray Fluorescence
process verifies the determine the water content

MF2P Pressure  39
automatic particle count to particle counting is quick, (XRF)
• analysis
Rated onupsamples
to 25 SCFM

Filters out particles from incoming air


in hydraulic fluid, which helps repeatable and accurate. It with extremely high
identify samples needing

Flows to:
to: 113.5
113.5 L/min
L/min (30
(30 USgpm)
USgpm)
us predict quality and provides reliable information concentrations of particulate
special preparation. This performance characteristics

Flows
provides confirmation of we can use to check against contamination. By isolating
for the fluid and system ISO Standard 4406, which chemical elements, we
automatic counter results, components. Excess water

Flows to:
Pressures 113.5
to: L/minbar
275.5 (30(4,000
bar USgpm)
(4,000 psi)
and helps us see what defines the relationship pinpoint contaminant types so
reduces the viscosity of between particle counts and we can establish their origins,

Pressures to: 275.5 psi)


contaminants are in the fluid. hydraulic fluid, which
hydraulic fluid cleanliness. and so you can take corrective
increases the likelihood of This lets us determine exactly action.

Elements: V051...series
Pressures V051...series
to: 275.5 bar (4,000 psi) 120
adverse chemical reactions what corrective actions,
Mobile-gate™ Filler Breather Assemblies
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Features/Benefits:
11
Part Number Elements: 120
• Proprietary Media: • Reversible Flow Through MBR110 5002486
Elements: V051...series  40
MBR110 and MBR120 Breathers  13
Reduces dew point Media: Allows for MBR120 5002487
temperature to prevent moisture to exit the
condensation and is reservoir.
99.7% efficient in

OFPH003/005 Series
Series Pressure
Pressure 122
• Easy Installation:

Filters out moisture and particles, ideal for mobile


blocking particles 10µ

OFPH003/005 122
Lightweight design can be
and larger. hand tightened.
• Water Barrier: • Rugged metal housing is

applications
Regenerates its water
shedding capacity with
each cycle.
long lasting and ideal for
mobile applications. FlowsSeries
Flows
HF4P up to:
up to:In
53Line
53 L/min
L/min (14Subplate
(14
and USgpm) 
USgpm) 42
MBR120
• Rated to 16.7 SCFM
Pressures to:
Pressures to: 310
310 bar
bar (4,500
(4,500 psi)
psi)
Flows to: 570
Elements: L/min (150
OFPH31 USgpm)
== V0603
V0603 123
MBR110

Elements: OFPH31 123


Items not in bold are non-standard and may have a longer lead time
Pressures to: 345 bar
OFPH51 (5,000
V0604 psi)
== V0604 123
Return Line Filters
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 17
OFPH51
OFPH52 == V0114
V0114
123
12343
Elements: V405...series
OFPH52  123
HV3R Series Return Line  17
Flows to: 280 L/min (75 USgpm) HF4P Series In Line and Subplate 125
HF4P Series
HF3P Series In In Line
Lineand
 Subplate 125
45
Pressures to: 50 bar (725 psi)
Flows to:
Flows to: 570
570 L/min
L/min (150
(150 USgpm)
USgpm)
Elements: V3R...series  18 Flows to: 454
Pressures to: L/min
to: 345 (120
345 bar USgpm)
bar (5,000
(5,000 psi)
Pressures
Pressures to: 420 bar (6,000 psi)psi)
Elements: V405...series
Elements: V405...series 126
126
Elements: V602...series  46
In-tank Filters HF3P Series
Series In
In Line
Line 128
HF3P 128
HF4RT Series In Tank  21 Flows to:
to: 454
454 L/min
L/min (120
(120 USgpm)
USgpm)
Accessories
Flows
Pressures to:
to: 420
420 bar
bar (6,000
(6,000 psi)
psi)
Flows to: 568 L/min (150 USgpm) Pressures
Pressures to: 7 bar (100 psi) Elements: V602...series
Differential
Elements: V602...series
Indicators  129
48
129
Elements: V405...series  22 Indicator Switch Schematics  50
HF3PS Series
HF3PS Series Side
Side Mount
Mount 131
131
Electrical Pressure Switch  52
Flows to:
Flows to: 565
565 L/min
L/min (150
(150 USgpm)
USgpm)
Suction Strainers Pressures
Gauge  to:
Pressures to: 310
310 bar
bar (4,500
(4,500 psi)
psi) 53
Elements: V602...series
Elements: V602...series 132
132
OF3 Series Inlet Strainer  24 Mounting Bracket  53
Flows to 379 L/min (100 USgpm)
Seal Kits  54 EATON Vickers
EATON Vickers
Notes  55
Spin-on Filters
OFRS 15 Series Spin-on  27
Flows to: 60 L/min (15 USgpm)
Pressures to: 7 bar (100 psi)
Elements: V019...series  28

HS22 Series Twin Spin-on  30


Flows to: 450 L/min (120 USgpm)
Pressures to: 14 bar (200 psi)
Elements: V021...series  31

Check out our full line of filtration products and accessories at www.eaton.com/filtration

2 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022


Introduction to Eaton Filtration

Fluid Power is one of the most reliable and repeatable


forms of power and motion control. When problems are
encountered, 80% of the time they are related to
inadequate contamination control practices. Eaton has
more than a 75-year history of dedication to helping
engineers develop, operate and maintain reliable, high
quality power and motion control systems.

Fluid Analysis
The systemic contamination Once the targetEaton
has been There are four primary
Fluid Analysis Service Critic
control approach assures set, the next step is to sources for solid
Eatonfilters
hydraulic components have a global reputation Fluid
the user of the hydraulic select and position contamination to enter hydra
for quality, reliability and performance. That reputation
system a cost effective in the system so that the a hydraulic fluid.
is built on a tradition of customer service and we keep
approach to contamination target can be achieved
stand behindin every oneThey are:products.
of our contaminated new
efficie
you n
control that allows the price a cost effective manner. oil, built-in contamination, it. Wh
Our Fluid Analysis Service follows that same tradition.
of the filters and elements After the machine ingressed
is in our customers
We provide contaminationfluid
with comprehensive hurt y
to be quickly recovered by operation, the last and
testing and
and diagnostic internally-generated
services, with detailed reports The E
the savings of improved ongoing step isthat
to are easy to understand.
confirm contamination.
Servic
fluid i
performance, increased that the target To
cleanliness a med
find out how the Eaton Fluid
component life, increased oil level is being maintained.
Analysis Service can help your samp
life, increased uptime and operation, read on. helps
fewer repairs. This is most often health
Then call us to hydra
accomplished by sending
The goal of systemic a fluid sample toget started.
a particle
us pin
conta
contamination control is counting laboratory that wheth
always the same: to clean gives cleanliness code data uses
the fluid to the point that to established standards. If We c
contamination is not a factor the target is being met, the
catas
failure
in the failure (catastrophic, system only needsA Name You Trust
to have comp
intermittent, or degradation) Onlyand
one fluid Eaton Fluid Analysis Service PN 894276
For a hydraulic or oil filters maintained the analysis lab lets you put years of Eaton and id
of any component in the experience to work for you. So when the health of
fluid retested periodically. If
maint
lubricated machine, the your hydraulic system is at stake, choose a partner botto
system during the desired the cleanlinesswith
target
moreisthan
not75 years of experience. Contact your
development of a target increa
useful life of that system. being achieved,Eaton representative for more information on our Fluid
corrective
cleanliness level and the Analysis Service.
plan to achieve it is as much The first step towards this actions need to be taken.
a part of system design as goal is the setting of a target Sometimes a change in
cleanliness level that takes Comprehensive
maintenance practices is Testing Viscosity (ASTM D445): and d
the selection of the pump, We use this test to determine perfor
valves, actuators or bearings. into account the specific needed, but at Theother times
Eaton a
Fluid Analysis the viscosity of your oil.
Service is certified to ISO Draw
needs of the system. shift to a finer grade of filter
12025 and offers a full range
Without proper hydraulic fluid Isolat
elements or additional filter designed viscosity,
of tests specifically
your equipment will we de
Vickers Systemic Sources of Contamination housings may be needed.
for the analysis of hydraulic
suffer. Incorrect viscosity conta
leads to fluid breakdown, fluids
Approach to Eaton doc. 561, page 8 and lubrication system fluid. inefficient equipment partic
Our laboratory equipment
Contamination Control and test procedures provide
operation, premature system organ
Generated Ingressed from cylinder rod failure and damage to other Used
• Set a target Cleanliness an exact analysis of your
by cylinder hydraulic or oil lubricated
components. photo
Level system, and our drawdown drawd
particle isolation procedure identi
• Select filters and filter ensures accurate results. of flui
placements to achieve A B Autom
target Our testing procedures (ISO 1
Generated by valve can include: intens
• Sample fluid and confirm P T a pho
Photomicrography: We
achievement scan and photograph a filter numb
patch using an optical in the
Pressure microscope to find particle define
accord
line filter size and type. The scanning Water (ASTM E203): We and q
process verifies the determine the water content
automatic particle count to partic
in hydraulic fluid, which helps repea
identify samples needing us predict quality and
Transfer cart
special preparation. Thisfilter performance characteristics
provid
provides confirmation of we ca
for the fluid and system ISO S
automatic counter results, components. Excess water
and helps us see what define
reduces the viscosity of
Return contaminants are in the fluid. hydraulic fluid, which
betwe
line hydra
Ingressed from Generated increases the likelihood of This le
Ingressed filter adverse chemical reactions
air breather what
by pump through
M reservoir M EATON Vic
openings Ingressed
from
Built-in debris new oil

4 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 3
Introduction to Eaton Filtration

Contaminated New Oil be metal, silica and fibers. Ingressed Contamination Generated Contamination
Although hydraulic and With fluids from reputable Contamination from the The most dangerous
lubrication fluids are refined suppliers, sampling has immediate surroundings can contamination to a system is
and blended under relatively shown typical Cleanliness be ingressed into the fluid the contamination generated
clean conditions, the fluid Levels of 17/16/14 or dirtier. power or lubrication system. by the system itself. These
travels through many hoses Using a portable transfer cart On large installations, such as particles are “work
and pipes before it is stored fitted with a high efficiency those within steelworks or hardened” to a greater
in drums or in a bulk tank at filter, contamination should automotive plants, it is hardness than the surface
the user’s facility. At this be removed from new fluids relatively easy to know the from which they came, and
point, the fluid is no longer before the contamination environmental conditions, are very aggressive in
clean as the fluid lines it has enters and damages the though they vary considerably. causing further wear in the
traveled through have components in the system. For example, a coke oven system. In a system running
contributed metal and rubber system operates in conditions on properly cleaned fluid very
particles, and the drums Built-in Contamination very different from a similar few particles are generated,
have added flakes of metal New machinery always system in a cold mill. For although all components
or scale. Storage tanks are a contains a certain amount of mobile equipment, there is a (especially pumps) create a
real problem because water built-in contamination. Care very wide variation in small amount of particles
condenses in them causing in system assembly and in environmental conditions by during routine operation. In a
rust particles. Contamination new component flushing application, location and even system where these particles
from the atmosphere can reduces this but never by weather conditions (i.e. are not quickly captured the
eliminates it. Typical built-in high winds). elevated contamination levels
The key is to severely limit will cause the number of
the access that environmental additional generated particles
contamination has to enter to increase at a highly
the hydraulic or lubrication accelerated rate! The best
system. There are four major way to prevent
ways dirt can enter a system: contamination generation
reservoir vent ports (breathers), within a system is to start
power unit or system access with a clean (fully flushed)
plates, components left open system and keep the system
during maintenance and fluid clean.
cylinder seals.

Eaton Clean Cart

also find its way into the Eaton H20 Gate Reservoir Breather BR110
tank unless satisfactory air
breathers are fitted. contaminants are burrs,
If the fluid is stored under chips, flash, dirt, dust, fiber,
reasonable conditions, the sand, moisture, pipe sealant,
principal contaminants on weld splatter, paint and
delivery to the machine will flushing solution.

4 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 5
Introduction to Eaton Filtration

Filter Element Initial Beta ratios and dirt capacity. Eaton Media Construction
Efficiency The most important Coated Steel Mesh

The international standard for information needed by a Non woven synthetic


diffuser layer
rating the efficiency of a designer or user of a
Proprietary glass
hydraulic or lubrication filter hydraulic system is the micro fiber media with
is the Multipass Filter system cleanliness they can special resin binder

Performance Beta Test (ISO expect when that filter and Non woven synthetic diffuser

16889). The results of this media are properly installed (drainage) layer

test are reported as a ratio of in the system. Coated Steel Mesh

number of particles greater Each grade of Eaton high


than a designated size efficiency filter media
upstream of the test filter construction is thoroughly
compared with the number multipass tested and then
of same size particles rated with the system
downstream of the test filter. cleanliness level expected to
These results are then be achieved with the use of
expressed as a Beta ratio. that product. The
Most Eaton™ filters are assumptions behind these may fail to answer the and gives the filter medium
rated at Beta x(c)=1000. See cleanliness ratings are: 1) the question of how an aged the support it needs to keep
individual filter “Features and filter sees full system flow, element will perform during from failing due to fatigue.
Benefits” for more detail. 2) the filter is the primary the latter part of its service The downstream wire mesh
filter in the system, and 3) life. also serves as a last chance
BETA RATIOS AND air breathers along with protection in case of
CORRESPONDING EFFICIENCIES The best way to deal with
recognized maintenance unexpectedly severe stress
Beta Ratios Efficiency this issue is to look at the
practices will limit dirt that causes element media
construction and feel the
1 0% ingression from the rupture.
element pleats. Are the
2 50.00% atmosphere.
pleats well supported? Do
5 80.00% A major problem in correlating they flex under hand Filter Condition Indicators
10 90.00% multipass test claims to real pressure? Any element that After the filters are placed
20 95.00% world fluid cleanliness levels fails these simple tests will within the system, the next
75 98.00% is that real systems operation fail to maintain efficiency and consideration is how the
100 99.00%
greatly stresses the element. integrity, and will not user is going to know when
In active systems, flow rate maintain the targeted to change the element. The
200 99.50% changes (often several times cleanliness level. answer recommended in
1000 99.90% a minute), pressure pulses DIN 24550 standard is to
5000 99.98% Additionally, look at the pack
(hundreds a minute), have all filters fitted with a
construction. Steel wire
Beta ratios and dirt capacity are only decompression shock differential pressure indicator
mesh is very important in
a guide to system cleanliness needs waves, cold starts and other that gives an easy-to-read
ref. Eaton doc. 561, page 19 element construction. Wire
variables all work to degrade indication that the element
keeps the pleats from flexing
a filter’s performance. In needs to be changed. Eaton
Multipass testing has greatly multipass testing the element
aided engineers in the is subject to one gradual rise LIMITS ON CORRELATION BETWEEN “BETA” AND SYSTEM
development of better and in differential pressure as the CLEANLINESS AND “DIRT CAPACITY” AND SERVICE LIFE
more efficient filter element loads! Laboratory Procedure Real World
elements, and it has helped Flow fatigue test protocol Pressure Rise One gradual rise Thousands of changes
the design engineer who (ISO 3724) leaves many Fatigue Cycles One Millions
needed to specify a filter important questions
element’s performance. But, Element Aging Minutes Months
unanswered. Again the Element Life One hour 800+ hours
there’s little correlation element is tested in laboratory
between multipass Contaminant AC fine test dust Debris, water, gas
conditions that cannot
efficiencies and system duplicate the interaction of Challenge Rate Constant Always changing
cleanliness needs. In the the many forces working to Fluid Used MIL 5606 Wide variety
final performance analysis, stress and degrade the Temperature 100°F (38°C) -20°F to 200°F (-7° to 93°C)
the goal is properly cleaned element. This laboratory test Flow Steady Thousands of changes
fluid and not just very high

6 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 5
Introduction to Eaton Filtration

indicators are designed to In poorly supported elements, changes in flow and pressure drop cause the
indicate at a pressure drop sides of element corrugations to flex and the root to stretch, giving rise to fatigue
20% below the bypass stresses. Dirt capacity is also lost as areas of the medium have no flow.
setting which equates to Eaton doc. 561, page 21
95% of the element’s
service life. This indication
before bypass feature was No flow Flow directions
incorporated to allow safe
operation of the machine Deflection under Filter medium
until the next shift change or high flow
convenient maintenance
opportunity.

Element Service Life


High stress under Flow fatigue failure is
As in any aspect of machine high flow conditions commonly at root of pleat.
design or maintenance, cost causes pleat to deform.
of installation and operation
are very important concerns. always use genuine Eaton media structure only, which
For filters, the length of elements because of their can give increased “dirt
time an element lasts in consistent performance capacity” under laboratory
service and the initial cost of and superior strength under conditions, but no increase
that element, combine to stress. in service life is experienced
determine the economics in real systems.
The third issue in long
of using that product.
element service life is the An often overlooked aspect
The most important aspect “dirt capacity” of the of dirt capacity and service
of gaining long element element. This value is life is the effect of element
service life is to minimize the calculated as part of the area. When comparing an
ingression! Reservoirs need multipass efficiency test. element of “x” area with an
to be fitted with vent filters Because of the many element of “2x” area, one
(=3µm) that remove the dirt differences between the test would expect twice the life
before it enters the system. conditions and real system for the larger element. But,
Access port and doors need operation, different dirt in real systems, the life
to be kept sealed so that dirt capacity values do not extension is most often
cannot be drawn into the correlate well to changes in between 2.5 and 3.5 times
system. Cylinder rods that element service life. Dirt as long. This is because the
extend into contamination capacity can only be used to reduced flow density through
laden environments should compare elements under a unit area of media allows for
be shielded to minimize the very specific laboratory more effective contaminant
dirt being drawn into the situations, and as a result capture. Larger elements are
system. published dirt capacity values the most cost effective
The second important aspect should be used as general approach to contamination
to long element service life information rather than control from the perspective
is to keep the cleanliness specific comparable data. of operating costs.
level of the fluid at or below Eaton elements are designed
target. Periods of machine to give long life and reliable
operation with dirty fluid service in hydraulic or
cause accelerated internal lubrication applications.
wear that loads a filter This is achieved with our
element. (It’s important the multi-layer construction.
debris is caught as it saves Each layer provides
the system, but it does cost additional strength or
the element part of its capacity leading to overall
service life.) Always change superior performance. Some
an element on indication and elements focus heavily on

6 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 7
Guide for Selecting Filters

Target Cleanlines that maintenance of the Housing for longer element life.
Using the Vickers Target system will be consistent The selected housing should Some systems require
Cleanliness Worksheet with current technology. be rated within the required filtration with no bypass,
(#578), it is easy to If in operation the system is flow and pressures of the such as servo applications.
determine the target ISO running dirtier than expected, application. Vickers H-Pak media is
Cleanliness Level for a corrective actions should be Important: If the system recommended for non-
system. This target is based initiated. Suggested corrective fluid’s specific gravity (SG) is bypass systems.
on the application’s actions are: greater than 0.9 (for
components and system • Check the indicator to example, water glycol), the Indicator
dynamics. see if the filters are on housing pressure drop (∆P) To meet ANSI Standard
by-pass. should be corrected for 12.2.5, filter assemblies
Placement and Media actual application. should have a device to
• Check the sources of
Use the chart below to help ingression and correct indicate when the filter
select the appropriate filter problems. Specific Gravity requires servicing. Per ANSI
placement and grade of Corrections for Pressure Standard 12.2.6, the
media to acheive the target • Check that the filters are Drops indicator should “trip” at
cleanliness level. For more positioned properly to see approximately 80% of the
maximum fluid flow. The filter housing flow
detail, consult the Eaton curves in this catalog can be bypass pressure setting. If
Guide to Systemic • Consider using a finer adjusted using the following using a non-bypass housing,
Contaminaton Control, Pak grade equation: an indicator selling of
your Vickers representative, approximately 100 psid is
• Add additional filters to Adjusted ∆PHousing =
or the ANSI System recommended. Differential
the system. ∆PCurve x Actual SG ÷ 0.9
Standards for Stationary pressure indicators are rated
Industrial Machinery. 6,000 psi working, 3,500 psi
Note: All systems need a Bypass Valve fatigue.∆
Filter Placement sealed reservoir with vent Bypass valve selection is
The chart below helps port filtration. based upon system
engineers select the grade requirements. According to
of Vickers media and the CAUTION ANSI Standard 12.2.6, filter
filter placement(s) that will assemblies whose elements
Before servicing the
acheive the required target cannot withstand full system
element, the bleed
cleanliness. It assumes the differential pressure without
plug in filter housing
system will experience damage should be equipped
must be loosened to relieve
“average” ingression and with bypass valves.
pressure. This will minimize
Generally, a higher bypass
fluid overflow.
pressure setting will allow

RECOMMENDED RECOMMENDED RECOMMENDED


FILTER PLACEMENT FILTER PLACEMENT FILTER PLACEMENT
TARGET FOR HIGH FOR SYSTEMS WITH FOR HIGH
CLEANLINESS INGRESSION VARIABLE VOLUME INGRESSION
SYSTEMS WITH PUMPS. SYSTEMS WITH
FIXED VOLUME VARIABLE VOLUME
PUMPS. PUMPS.

Full flow pressure Full flow pressure Pressure line/ Pressure line plus Recirculating loop at Recirculating loop at
line or return line line or return line recirculating loop at return line plus 20% of system volume 10% of system volume
20% of system volume recirculating loop per minute per minute
per minute
14/12/10 - 03 03 03 - -
15/13/11 - 03 03 05 - -
16/14/12 03 05 05 05 or 10 03 03
17/15/13 03 05 05 05 or 10 03 03
18/16/14 05 10 05 or 10 10 05 03
16/14/10 05 or 10 10 10 10 05 or 10 05

8 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 7
Guide for Selecting Filters

Surge Control H-Pak Construction L-Pak Construction


Surge Control is used on For systems where a bypass The L-Pak is specially
systems where spikes and valve is undesirable, such as designed for lubrication
surges in the hydraulic servo systems, the H-Pak applications. Using the same
system could prematurely media provides high collapse five layer construction as the
trip the indicator. Surge rated housing pressures. C-Pak, the L-Pak also has a
controls slow the indicator H-Pak media construction deep pleat construction to
response. If the indicator utilizes 304 stainless steel maximize element life in
encounters a continuous inner and outer mesh support steady flow, low pulsation
high differential pressure, it along with heavier core systems.
will trip at the rated setting. tubes and media support to
protect the system.
Element
C-Pak Construction
The Vickers element media
grade should be selected C-Pak media uses five
to acheive the Target layer construction. C-Pak
Cleanliness Level. The incorporates epoxy coated
Vickers media construction carbon steel as the two
should be chosen based outer face layers to retain
upon system requirements the inner media pak layers.
such as flow characterstics,
R-Pak Construction
pressure surges and specific
application conditions. The R-Pak spin-on filter
elements are designed for
Important: If the system low clean pressure drop
fluid’s specific gravity (SG) and high efficiency. R-Pak
is greater than 0.9 (for incorporates a five layer
example, water glycol), the media construction with
element pressure drop outer layers of epoxy coated
(∆P) should be corrected. carbon steel wire to retain
the inner media pak layers.

Viscosity Corrections for Pressure Drops


The element flow curves can be adjusted using the following equations:
Adjusted Clean ∆PElement =
Actual viscosity in cP ÷ 29 x ∆PCurve
Actual viscosity in cSt/32 x Actual SG ÷ 0.9 x ∆PCurve
Actual viscosity in SUS/150 x Actual SG ÷ 0.9 x ∆PCurve
A good “rule of thumb”. To ensure satisfactory element life, the clean element pressure
drop should generally be less than or equal to 40 percent of the indicator’s rated differential
pressure:
∆PElement = 0.4 x ∆PIndicator
The best way to extend element service life is to minimize ingression (vents, seals, cylinder
rods) and maintain system cleanliness at or below the Target Cleanliness Level.

8 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 9
Fluid Analysis
Eaton Fluid Analysis Service Critical Analysis Clear Benefits
Eaton hydraulic components have a global reputation Fluid is the lifeblood of every We offer testing designed to
for quality, reliability and performance. That reputation hydraulic power system. To tell you the most about your
keep yours running hydraulic fluid. We use
is built on a tradition of customer service and we
efficiently and effectively, sophisticated computer
stand behind every one of our products. you need to know what’s in programs and laboratory
Our Fluid Analysis Service follows that same tradition. it. What you don’t know can diagnostic equipment such
hurt you. as an Energy Dispersive
We provide our customers with comprehensive fluid
The Eaton Fluid Analysis X-ray Fluorescence and an
testing and diagnostic services, with detailed reports inductively coupled plasma
that are easy to understand. Service analyzes hydraulic
fluid in much the same way spectrophotometer.
To find out how the Eaton Fluid a medical lab tests a blood After we use this advanced
Analysis Service can help your sample. Just as a blood test equipment to provide the
operation, read on. helps a doctor diagnose most detailed possible
health problems, a sample of analysis of your hydraulic
Then call us to hydraulic fluid can help fluid, we create reports that
get started. us pinpoint sources of are always easy to read and
contamination and determine understand. By taking the
whether or not your system mystery out of fluid analysis,
uses adequate filtration. we provide a service that
We can help you reduce clearly explains the benefits
catastrophic equipment of clean fluid.
failures, maintain optimum
A Name You Trust
component performance,
Only one fluid analysis lab lets you put years of Eaton and identify any substandard
experience to work for you. So when the health of maintenance practices. Your
your hydraulic system is at stake, choose a partner bottom-line benefit is
with more than 75 years of experience. Contact your increased productivity.
Eaton representative for more information on our Fluid
Analysis Service.

Comprehensive Testing Viscosity (ASTM D445): and degrades equipment if any, are needed. The lab
We use this test to determine performance. is also capable of testing to
The Eaton Fluid Analysis the viscosity of your oil. the new ISO 4406(1999)
Service is certified to ISO Drawdown Particle
Without proper hydraulic fluid Isolation: Using this test, standard (4µ, 6µ,14µ).
12025 and offers a full range viscosity, your equipment will
of tests specifically designed we determine the insoluble Spectrometric Analysis
suffer. Incorrect viscosity contaminates in hydraulic (ASTM D 5185): This shows
for the analysis of hydraulic leads to fluid breakdown,
and lubrication system fluid. fluids, both insoluble us the concentration of oil-
inefficient equipment particles and gel-like matter, soluble elements and
Our laboratory equipment operation, premature system
and test procedures provide organics and inorganics. indicates the additives and
failure and damage to other Used in conjunction with trace metal content in the
an exact analysis of your components.
hydraulic or oil lubricated photomicrography, the fluids. We use this technique
system, and our drawdown drawdown patch helps us to evaluate the condition
particle isolation procedure identify the source and type of the additives in a fluid
ensures accurate results. of fluid contaminants. rather than its particulate
Automatic Particle Count contamination. Used in
Our testing procedures (ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle counting, it helps us
a photo sensor to count the accurately assess the
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter number and size of particles
patch using an optical in the fluid sample and then Energy Dispersive X-ray
microscope to find particle define contaminants Fluorescence (ASTM E
size and type. The scanning according to size distribution 1508): We perform Energy
Water (ASTM E203): We and quantities. Automatic Dispersive X-ray Fluorescence
process verifies the determine the water content
automatic particle count to particle counting is quick, (XRF) analysis on samples
in hydraulic fluid, which helps repeatable and accurate. It with extremely high
identify samples needing us predict quality and
special preparation. This provides reliable information concentrations of particulate
performance characteristics we can use to check against contamination. By isolating
provides confirmation of for the fluid and system
automatic counter results, ISO Standard 4406, which chemical elements, we
components. Excess water defines the relationship pinpoint contaminant types so
and helps us see what reduces the viscosity of
contaminants are in the fluid. between particle counts and we can establish their origins,
hydraulic fluid, which hydraulic fluid cleanliness. and so you can take corrective
increases the likelihood of This lets us determine exactly action.
adverse chemical reactions what corrective actions,

EATON Vickers Filtration


EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 119
Fluid Analysis
Easy-to-Read Reports 1. Results Target: A results Fluid Test Results
Fluid Results
target compares your
We present your fluid test actual fluid cleanliness 2 5
results in a format that is results and your ideal
easy to understand. Results cleanliness level. If you
typically include these items: don’t have a target level yet,
we can use your sample to
help you determine what
it should be. WATER 15

2. Trend Information: We
evaluate data from your VISCOSITY
previous two samples On-target Re-sample
along with the results of Marginal Immediate action
your current sample. This
provides a trend analysis
of critical measurements, TEST 1 TEST 2 TEST 3
and shows changes in the Time Present Previous #1 Previous #2
fluid over time. Viscosity 45.0 (210) 45.5 (212) 45.8 (213)
@ 100˚F cSt (SUS)
pH (ASTM E 70)
represents the strength of Water 0.03% 0.03% 0.03%
% Weight
Vacuum Pump PN 894279 acidity in hydraulic fluid,
and is usually measured pH 9.4 9.5 9.6
Note: pH is for water containing fluids only.
for water-containing
hydraulic fluids TAN mg KOH/gm 2.1 2.0 2.1
Note: TAN is for synthetic fluids only.
(water/glycols, invert
emulsions). Typical values
are 8.5–10.5. Particle Count Summary
Total Acid Number, or TEST 1 TEST 2 TEST 3
Time Present Previous #1 Previous #2
TAN (ASTM D 974), is the
amount of acid and acid- >2µ 65,120 4,100 418
acting material constituents >5µ 12,220 1,250 88
in hydraulic fluid. An >10µ 5,800 700 39
increase in TAN indicates >15µ 900 250 22
oxidation or acid >25µ 125 60 4
contamination. Some >50µ 12.0 5.0 1.0
hydraulic fluids exhibit
higher acid numbers than Cleanliness 23/21/17 19/17/15 16/14/12
Code
others. Typical values are
0.1–3.0.

KIT FEATURES

Photo Energy
Automatic Microscopy Dispersive Spectrographic
Particle Water Viscosity Drawdown XRF ASTM Analysis
Kit Count ASTM TAN/PH ASTM Particle E1508 ASTM
Part # ISO 11500 E203 (if applicable) D445 Isolation (if applicable) D5185
894276P • • • • • •
894277P • • • • • • •
Each kit includes:
• Super clean sample bottle
• Packaging for sending sample
• Numbered test sample data form
• Fluid analysis service

Also available is PN 894279, Vacuum Pump for extracting oil sample, and PN 932339, Ultra Clean Bottle.

Items not in bold are non-standard and may have a longer lead time
12
10 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Fluid Analysis Range Code
Cleanliness Code Graph
300,000
25 200,000
100,000 150,000
24 100.000
80,000
3. Cleanliness Code Graph: 23 50,000
This graph uses the ISO 40,000 40,000
22 30,000
4406 standard for 20,000 20,000
measuring and depicting 21 15,000
10,000 10,000
the amount and size of 20
particles per milliliter in 5,000 5,000
4,000
hydraulic fluid, shown in a 19 3,000
2,500 2,000
log-log2 graph that charts 18 1,500
the amount of particles 1,000 1,000
17
greater than certain micron 500

Number of particles greater than size per mililiter


500
sizes per milliliter of fluid. 16 400
250 300
Recommendations: This 15 200
100 150
section of the report 14 100
provides you with valuable 80 50
information on the 13 40
40 30
cleanliness of your 12 20
20
hydraulic system, as well 11
10
as tips on maintaining or 10 10
improving its current 10
5 5
condition. 9 4
3
2.5 2
8 1.5
1.5 1.0
7
1 .5
6 .4
.5 .3
5 .2
.15 .01
4 .1
.08
3
.04
2
.02
1 .01
1 4 6 10 14 20 25 30 35 40 45 50
20/14/12 Particle size in micrometers
Cleanliness code

Sample XRF Analysis 100


Results
When a fluid sample shows 90
high particulate 80
contamination, we use
Energy Dispersive X-ray 70
Fluorescence (XRF) analysis 60
to isolate and identify
Percent

chemical elements. The 50 47.8%


results are shown in a graph
40
like this.
30 24.7%
20
13.9%
10 9.0%
4.6%
0
Ca P S Fe Zn
Element

EATON Vickers Filtration


EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 13
11
Breathers

Hydraulic reservoirs “breathe” air in and out as the oil level rises and falls.
This circulating air contains particles and moisture that can cause
corrosion, increase equipment wear and reduce fluid performance. In
typical systems, the internal hydraulic fluid is warmer than the
external environment. This difference in temperatures causes
water vapor to form. Breathers protect your hydraulic
system by filtering out damaging moisture and particles.
More than 25% of the samples sent to the Eaton Fluid
Analysis Laboratory for analysis have significant water
contamination. In an operating system, the H20-gate
Vent Breather creates a moisture barrier when there
is a 5°F (2°C) difference between reservoir and
ambient temperature and when there is a 10%
per minute exchange of air volume above the
fluid. The Mobile-gate breather is smaller in
size but is also 1/4 the size and 1/2 the capacity
of the H20-gate. These temperature and air flow
conditions are present in most hydraulic systems
which employ a cylinder.

Part Numbers:
NPT Mobile-gate MBR110
Flange Mobile-gate MBR120
H20-gate BR110
Dirt-gate BR210

Performs as a gate Works even when the Reduces humidity inside


During the “inhalation” cycle, system is shut down. reservoir.
the proprietary media blocks The H20-gate and Mobile- The H20-gate and Mobile-
the water vapor from entering gate Vent Breather retard the gate Vent Breathers lower
the reservoir. During the vapor equilibrium process and stabilize the relative
“exhalation” cycle, the media and work to prevent humidity of air inside the
allows the moisture in the condensation even after the reservoir, leading to a lower
reservoir air to exit. The system is shut and cooled dewpoint (Tdewpoint <
moisture is carried off the down, such as overnight. As Tambient = NO
media by the exiting air, this chart illustrates, the CONDENSATION) at a rate
restoring the media’s water dewpoint is slow to climb, and amount that will be
barrier capacity and the even after the system dependent upon several
moisture barrier mechanism is temperature has dropped to conditions: the ambient
not affected by the amount of the ambient temperature. conditions, the internal
exposure to moisture. The Once the system has reservoir heat, amount and
reservoir air is maintained at a reached ambient frequency of reservoir air
low relative humidity and temperature, condensation flow through the vent and
more importantly, at a lower does not occur. the temperature of the
dew point temperature than reservoir surfaces.
the ambient temperature.
BREATHER FEATURES

H2O-gate Dirt-gate Mobile-gate


Visual Indicator • • •
Particle Control • • •
Water/Moisture Control • •
Corrosion Resistant Housing • • •
Flow Rate 708 L/min 708 L/min 473 L/min
(187 USgpm) (187 USgpm) (125 USgpm)

16
12 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Breathers

H2O-gate™ Reservoir Breather

Features/Benefits: • Media contains oil Part Numbers:


• Visual Mechanical attractant layer to collect
and return oil splashes. H20-gate BR110
Indicator: Actuates when
Bayonet Adapter 924710
particles have blocked the • Easy Installation:
media, before the pump Lightweight design can Screw-in Adapter P-077002
cavitates. be hand tightened onto
• Proprietary Media: adapter.
Reduces dew point • Durable Plastic Housing:
temperature to prevent Protects the media from
condensation and is external splashing.
99.7% efficient in blocking • Superior breather filters
particles 3µ and larger. both moisture and
• Reversible Flow Through particles from air.
Media: Allows for • Effective up to 121°C
moisture to exit the (250°F)
reservoir.
• Rated up to 25 SCFM

Dirt-gate™ Reservoir Breather


Features/Benefits: Part Numbers:
• Visual Mechanical • Durable Plastic Housing: Dirt-gate BR210
Indicator: Actuates when Protects the media from
particles have blocked the external splashing. Bayonet Adapter 924710
media, before the pump Screw-in Adapter P-077002
• High Efficiency:
cavitates. (99% at 2 microns)
• Easy Installation: • Very Low Pressure Drop Note:
Lightweight design can
be hand tightened onto • Filters out particles This breather does not filter
adapter. moisture from air.
• Effective up to 121°C
(250°F)
• Rated up to 25 SCFM

Mobile-gate™ Filler Breather Assemblies

Features/Benefits: Part Number


• Proprietary Media: • Reversible Flow Through MBR110 5002486
Reduces dew point Media: Allows for MBR120 5002487
temperature to prevent moisture to exit the
condensation and is reservoir.
99.7% efficient in • Easy Installation:
blocking particles 10µ Lightweight design can be
and larger. hand tightened.
• Water Barrier: • Rugged metal housing is
Regenerates its water long lasting and ideal for
shedding capacity with mobile applications.
each cycle.
• Rated to 16.7 SCFM
MBR120
MBR110

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration
EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 17
13
Breathers

H2O-gate Specifications Dirt-gate Specifications


19 19
133,4 (.75) 133,4
(5.25) (.75)
(5.25)

105
(4.13)
184,2 12
(7.25) (.47)

12
(.47)
1.5 UN Straight Thread

1.5 UN Straight Thread

H2O-gate Pressure Drop Dirt-gate Pressure Drop


Fluid Displacement L/min (USgal) Fluid Displacement L/min (USgal)
283 850 1416 1982 2406 283 850 1416 1982 2406
(75) (225) (375) (525) (675) .0075 (75) (225) (375) (524) (636) .0075
3.0 3.0 (.108)
(.108)
2.7 2.7
2.2 2.2
Inches of water

.005
Inches of water

2.0 .005 2.0


(.073) (.073)

bar (psi)
bar (psi)

1.7 1.7
1.2 1.2
1.0 .0025 1.0 .0025
(.036) (.036)
0.7 0.7
0.2 0.2

0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Air Flow, SCFM Air Flow, SCFM

Mobile-gate Specifications
PART NUMBER FLOW DIMENSIONS (in)

USgpm L/min D1 D2 D3 D4 H1 H2 T1
MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4
MBR120 125 475 3.08 1.88 - 2.50 3.50 -
MBR120 FLANGE - - - - 0.25 2.81 - - -

D1 D1

H1 H1 D3

D4
H2
H2 T1

D2
18
14 EATON Vickers Filtration
EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Breathers
Adapters

Installation Dimensions

Threaded Pipe Adaptor Bayonet Adaptor


82,6
(3.25)
21,7
(.853) 25,4
19,1 (1.00)
(.750) Vent Filter

O-ring 11/4 NPT


Bayonet Adaptor
11/2-16 UN
Standard Mounting
Flange of a reservoir
filler/breather
assembly
MODELS AND PART NUMBERS
Part Number Description Vent Filters Applicable
924710 Bayonet, no check BR110, BR210
P-077002 Threaded pipe BR110, BR210

All Eaton Vent Filters are easily applied


to reservoirs via Spin-On adaptors.

EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 19
15
Return Line Filters

General Data
Return line filters usually have spin-on type elements, Return line filters may also be equipped with fluid
cartridge elements in an in-line mounted housing, or sampling devices to monitor the fluid cleanliness
cartridge elements within a housing that is mounted level. Secondary ports may also be incorporated to
directly within the reservoir itself (sometimes referred add make-up fluid and ensure that the fluid is
to as an in-tank filter). transferred through a filter before entering the system.

Return line filters are:


• An integral part of an • A crucial component
effective contamination when cylinders are
control solution. present in the system.
• Ideal for systems where Cylinders potentially
the pump is the sensitive contribute a large amount
component. of contamination
ingression and return line
• An economic means filters are ideal for this
of achieving the target type of control solution.
cleanliness level.
• Sometimes the only filters
• Often placed before the necessary (combined with
fluid enters the reservoir a breather) when seeing
in order to prevent debris the entire system flow on
and particles from a continuous basis.
recirculating through the
system. • Only a part of an effective
contamination control
solution when the
system employs variable
displacement pumps.
Filters in systems like this
may be supplemented by
pressure and/or off-line
filters.

Applications
• Stroke boom delimbers
• Drilling platforms
• Die cast machines/
injection molding
• Large machine tools

Items not in bold are non-standard and may have a longer lead time
20
16 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series

Features and Benefits DESIGN SPECIFICATIONS

• Beta Ratio: βx(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 240 L/min (63 USgpm)
Length 4 280 L/min (74 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -30°C to 121°C (-22°F to 250°F)
• Visual and electrical Pressure rating: Operating 50 bar (725 psi)
indicators with lamp Fatigue 50 bar (725 psi)
options for system design Material: Head Aluminum
flexibility Bowl Carbon Steel
• Fully serviceable without Collar Carbon Steel
tools Dry weight: Length 1 2,3 kg (5.1 lbs)
• Zero leak by-pass valve (Approximate) Length 2 2,5 kg (5.5 lbs)
Length 4 3,4 kg (7.5 lbs)
construction
• Wide range of element
lengths for maximum
design flexibility
• High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HV3R * ** * ** * * * **
• High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HV3R Series 1 Filter Series - HV3R QH - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann Hirschmann
Model Code 2 Element Collapse Rating
LN - Visual (30 psi)
No Connector 6 Seal Material
1 - 17 bar (250 psi) Low Collapse RB - Electrical 2 bar (30 psi) B - Buna-N
Sample model code: 4 - 207 bar (3000 psi) High Brad Harrison V - Viton-A
Collapse RJ - Electrical 2 bar (30 psi)
HV3R1SC4RLB2C05 Viton is a registered trademark of E.I. DuPont
Hirschmann w 24 volt
3 Port Options light 7 Assembly Length
BC - G 1-1/4 to ISO 228 RK - Electrical 2 bar (30 psi) mm (inch)
SC - 1.625 - 12UN SAE-20 str. Hirschmann w 115 volt 1 - 207 (8.15)
Thd. (1-1/4" tube) light 2 - 266 (10.47)
RL - Electrical 2 bar (30 psi) 4 - 447 (17.6)
4 Valve Options Hirschmann w 230 volt
1- Non-Bypass light 8 Element Construction
3- Bypass set at 1.7 bar (25 psi) RH - Electrical 2 bar (30 psi) C - 17 bar (250 psi) Low Collapse
4- Bypass set at 3 bar (43 psi) Hirschmann H - 207 bar (3000 psi) High
6- Bypass set at 6 bar (87 psi) AN - Visual (70 psi) Collapse
No Connector X - no element
5 Indicator Options UB - Electrical 4.9 bar (70 psi)
JN - No Indicator (plug), Brad Harrison 9 Fluid Cleanliness Rating
No Connector UJ - Electrical 4.9 bar (70 psi) Target fluid
QB - Electrical 1 bar (15 psi) Hirschmann w 24 volt Code cleanliness level
Brad Harrison light *03 16/14/12 or better
QJ - Electrical 1 bar (15 psi) UK - Electrical 4.9 bar (70 psi) *05 18/16/14 or better
Hirschmann w 24V light Hirschmann w 115 volt
light *10 20/18/15 or better
QK - Electrical 1 bar (15 psi)
Hirschmann w 115V light UL - Electrical 4.9 bar (70 psi) *20 22/19/16 or better
QL - Electrical 1 bar (15 psi) Hirshman w 230 volt light XX no element
Hirschmann w 230V light
EATON
EATON Vickers
Vickers Filtration Catalog E-FIFI-MC002-E2
Filtration Catalog E-FIFI-MC002-E2December 2007
February 2022 21
17
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series

V3R * * * **

1 2 3 4 5

V3R Element 1Filter Element 3 Element Length 5 Fluid Cleanliness Rating


Model Code V3R - For use with HV3R mm (inch) Target fluid
series housings 1 - 114 (4.5) Code cleanliness level
Sample model code: 2 - 173 (6.8) *03 16/14/12 or better
2 Seal Material 4 - 356 (14) *05 18/16/14 or better
V3RB1C05
B - Buna-N *10 20/18/15 or better
V - Viton-A 4 Element Construction
*20 22/19/16 or better
C - C-Pak (code 03, 05, 10, 20)
H - H-Pak (code 03, 05, 10) * C - Pak only

Housing Dimensions Mounting Holes


3/8 - 24 X 14 (0.56) deep with SC (SAE-20) port option
mm (inch)
M10 with BC (G 1-1/4) port option

56
(2.2)

ø130
7.4 (5.12) Indicator Plug
(0.29)
Label
46.4
(1.83)
1 5/8-12UNF in. or G 1 1/4 port
SAE-20 port
2 PL'S

Refer to
Model Code

ø82.5
(3.25)
50.0 (1.97) ø125
Clearance for (4.92)
Element Removal

Items not in bold are non-standard and may have a longer lead time
22
18 EATON
EATON Vickers Filtration Catalog
Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December 2007
February 2022
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
Flow versus pressure drop:
HV3R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data

HV3R Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)


2 0.008 (0.450) 0.006 (0.332) 0.004 (0.196) 0.002 (0.127)
4 0.004 (0.220) 0.003 (0.170) 0.002 (0.092) 0.001 (0.071)
H -pak 1 0.017 (0.919) 0.010 (0.569) 0.006 (0.321) xxx
2 0.011 (0.578) 0.007 (0.374) 0.004 (0.214) xxx
4 0.006 (0.312) 0.003 (0.184) 0.002 (0.097) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
13 40 66 13 40
1,4 5,0
1,2 17
Pressure drop - PSID

Pressure drop - PSID


Pressure drop - bar

Pressure drop - bar

4,0 58
1,0
0,8 12 3,0
0,6 2,0 29
0,4 6
1,0
0,2
0
0 50 100 150 200 250 300 0 50 100 150 200
Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : HV3R1SC4RLB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.7x 0.8/0.9 + 100 x 0.006 x 46/32 x 0.8/0.9
= 0.620 + 0.76
= 1.38 bar

EATON
EATON Vickers Filtration Catalog
Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 23
19
In-tank Filters

General Data
In-tank filters are a special type of low pressure return The filter housing may be equipped with diffusers
line filters. In-tank filters are mounted directly to the to ensure that the returning oil energy is gradually
reservoir tank top and have an accessible head that is dissipated within the reservoir fluid to minimize
located outside of the reservoir while the body of the the potential for aerating or foaming of the oil. In
housing is located inside the reservoir. The exposed addition, the diffuser helps direct the fluid outward
cover allows the element to be easily replaced as against the walls of the reservoir to aid in the heat
needed. transfer capability of the reservoir.

Applications
• Forestry harvesting
equipment such as
delimbers and feller
bunchers
• Injection molding or blow
molding equipment
• Offshore drilling platform
power units
• Machine tools
• Die cast machines

Items not in bold are non-standard and may have a longer lead time
44
20 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
In-tank Filters Flows to 454 L/min (120 USgpm)
Pressures to 7 bar (100 psi)
HF4RT Series

Pop-rivets for
shipping purposes
only. Remove prior
to installation.

Features and Benefits DESIGN SPECIFICATIONS

• Beta Ratio: βx(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 454 L/min (120 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards. Temp range: -30°C to 121°C (-22°F to 250°F)
• Conforms to HF4 Pressure rating: Operating 7 bar (100 psi)
specifications Fatigue 7 bar (100 psi)
• Gauge and electrical Material: Head Aluminum
switch options available to Cover Aluminum
monitor element loading Bowl Carbon Steel
Dry weight: Length 3 4,5 kg. (10.0 lbs.)
• In-tank configuration (Approximate) Length 6 6,6 kg. (14.5 lbs.)
minimizes space Length 7 8,4 kg. (18.6 lbs.)
requirements and potential
system leakage points
• Optional secondary
port allows filtration of a
second return line without
additional fittings or
filtered fill port
• High efficiency
replacement elements in
standard configurations (C-
Pak) to meet Target
Cleanliness Levels. HF4RT 1 ** * ** * ** * * **
Optional extend tube
allows smaller filtration unit
1 2 3 4 5 6 7 8 9 10
to be used where needed
HF4RT Series 1 Filter Series - HF4RT 5 Indicator Options* SZ - 2.50 - 12 UN SAE-32 str.
Filter and Element Thd. (2" tube) - use with
XX - No indicator
Model Code FE Inlet Port
2 Element Collapse Rating GA - Gauge 0-4 bar (0-60psi)
XX - No Secondary Port
1 - 10 bar (150 psi) Low GB - Gauge 0-10 bar (0-160psi) Note: No secondary port option is available
Sample model code: Collapse MB - Electrical, 15 PSI with the ME inlet port option.
Brad Harrison
HF4RT1SD313XXBC05 3 Port Options RB - Electrical, 30 PSI 8 Seal Material
BC - G11/4 to ISO 228 Brad Harrison
B - Buna-N
ME - 11/2" - SAE 4 bolt Flange MH - Electrical, 15 PSI V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
SD - 1.875 - 12 UN SAE-24 RH - Electrical, 30 PSI 9 Element Construction
str. Thd. (11/2" tube) Hirschmann
C - Standard Construction
FE - 11/2" - SAE 4 bolt Flange X - no element
Code 61 (UNC)
6 Assembly Length
mm (inch)
3 - 378 (14.9)
10 Fluid Cleanliness Rating
4 Valve Options Target fluid
6 - 584 (23)
3 - Bypass set at 1.7 bar 7 - 787 (31) Code cleanliness level
(25 psi)
cracking pressure 03 16/14/12 or better
7 Secondary Port
4 - Bypass set at 3 bar 05 18/16/14 or better
(43 psi) cracking BC - G11/4 to ISO 228 - use 10 20/18/15 or better
pressure with BC Inlet Port
SD - 1.875 - 12 UN SAE-24 20 22/19/16 or better
str. Thd. (11/2" tube) - XX no element
use with SD Inlet Port
* For indicator options, refer to Static Indicators on page 150.

EATON Vickers
EATON Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2022
2007 21
77
In-tank Filters Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
HF4RT Series

V405 1 * * C **

1 2 3 4 5 6

V405 Element 1 Filter Element 4 Element Length 6 Fluid Cleanliness Rating


Model Code V405 - For use with HF4RT mm (inch) Target fluid
3 - 229 (9) Code cleanliness level
Sample model code: 2 Element Collapse Rating 6 - 457 (18) 03 16/14/12 or better
1 - 10 bar (150 psi) 7 - 686 (27)
V4051B3C05 05 18/16/14 or better
Low Collapse
5 Element Construction 10 20/18/15 or better
3 Seal Material C - C-Pak (code 03, 05, 10, 20) 20 22/19/16 or better
B - Buna-N
V - Viton-A

Housing Dimensions
mm (inch)
112.2
(4.42)
56.1 M10 or
(2.21) 3/8"-20 thread
4 PL'S
Equally
spaced

112.2
(4.42) ø127
(5.0")
ø158.75
(6.25)

56.1 Reservoir Opening Inlet port


(2.21)
152.2 170.2 3.6
(6.00) (6.70) (0.14)

Secondary 118.5
port
(4.67)

Indicator port
1/8 NPT 53.6
(2.11)
Refer to
Model Code
"ME" port - M12 x 1.75
"FE" port - 1/2 - 13UNC (4 places)
69.8
(2.75) 35.7
(1.41)

Outlet port
Length Connection
3 1" Hose ø38.1 (1.5)
Ø124.6 6 1 1/2" NPT SAE-4 bolt
flange code 61
(4.9) 7 1 1/2" NPT
Inlet Flange

78 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007

22 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022


In-tank Filters Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
HF4RT Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF4RT Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 3 0.003 (0.168) 0.003 (0.140) 0.001 (0.078) 0.001 (0.044)


6 0.001 (0.080) 0.001 (0.066) 0.001 (0.037) 0.001 (0.021)
7 0.001 (0.051) 0.001 (0.043) 0.001 (0.024) 0.001 (0.013)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


26 79 26 79
0,8 12 4,5
43 PSI
4,0 4,0
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

0,6 3,5
3,0 3,0
0,4 6 25 PSI
2,5
2,0 2,0
0,2
1,5
0
0 100 200 300 400 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : HF4RT1SD3XX3XXBC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.15 x 0.8/0.9 + 200 x 0.003 x 46/32 x 0.8/0.9
= 0.130 + 0.76
= 0.89 bar

EATONVickers
EATON Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022 23
79
Series
OF3Inlet Strainers
Series Inlet Strainers
Flows to 379Flows
L/min to
(100
379USgpm)
L/min (100 USgpm)
ries Inlet Strainers Flows to 379 L/min (100 USgpm)
OF3 Series Inlet Strainers Flows to 379 L/min (100 USgpm)
ures and Benefits
Features General Data
and Benefits General Data
Element Selection
Element Selection
less steel elements have 149 These Vickers inlet strainers protect The size and number of elements
The size and number of elements
and
on (100Benefits
mesh) Stainless
screen steel
micron (100
General
elements
to protect
mesh)
haveData
hydraulic
screen to
149
pumps
protect
These Vickers inlet Element
and control systems
strainersselected Selection
protect should be based on the
selected should be based on the
aulic pumps from solid hydraulic pumps and control systems
el elements have 149 pumpsThese
hydraulic from solid
from solid
Vickers inletcontaminants.
strainers They shouldThe sizemaximum and number flowofratings listed on this
elements
maximum flow ratings listed on this
aminants. fromprotect
solid contaminants. They page.should
The ratings are conservative, and
mesh) screen to protect
contaminants. hydraulic bepumps
used as andimmersion
control suction strainers
systems selected should be basedpage. on theThe ratings are conservative, and
be used as immersion suction strainers
a change in fluid viscosity
able from
mps
Features and Benefits
flow rates
solid to 379 L/min
Available flow oncontaminants.
fromtosolid
rates 379 pump inlet lines.
L/min General Data
They should maximum flow ratings listed on thisshould
a change in fluid
not
Element Selection
viscosity should not
on pump inlet lines. significantly affect capacity.
s.USgpm). Higher rates can be page. The ratings are conservative, significantlyand
affect capacity.
eved by using(100 USgpm).
multiple Higher
be used
strainers. rates can be Valve
as immersion
Bypass suction strainers
should not The size and number of elements
Stainless
L/min bysteel
w rates to 379achieved onelements
using multiple
pump inlet lines. 149 Bypass
have
strainers. These Valve a change
Vickers inlet in fluid viscosity
Cleaning
strainers protect
ssHigher
). valve available
rates canto
micron
Bypass be prevent
(100available
valve mesh) screen
Anprevent
to to protect
available integral relief valve
hydraulic significantly
pumps and affect
control capacity. Cleaning selected should be based on the
systems
em shutdown.
using multiple strainers. Bypass Valve An available integral relief valve The strainer elements should be
hydraulic
system pumps
shutdown. from solid
parallels the element and is preset to maximum
The strainer elements flow
should beratings listed on this
eent media to
available is contaminants.
pleated
prevent for longAn available
openintegral
at a 3 psi
parallels
pressure
from
the element
drop across Cleaning
solid contaminants.
and is cleaned They should
preset toperiodically. Remove the
Element media is pleated for long reliefopen valveatbe
a 3used asThe
psi pressureimmersion
drop across
elements suction cleaned
strainers
from should
the reservoir, washpage.
periodically. The
Remove ratings
the are conservative, and
down. the element. Element bypassing can be strainer elements be from
elements
Available flowparallels
life. tothe379
rates caused element
L/min andtheis preset
element.
on to Element
pump inletbypassing
lines. can bein a suitable
thoroughly solvent, athe
and
reservoir,
change in wash
fluid viscosity should not
ents
dia can be cleaned
is pleated for long and open at a 3 psi pressure by excessdrop flowacross
rates, high fluidcleaned periodically. Remove the in a suitable solvent, and
thoroughly
ed. (100
Elements USgpm). Higher
can be cleaned rates can
and
viscosity, becaused
dirt-loaded
by excess flow rates,
elements, or a elements
high fluid
blow
fromdry with
the air fromwash
reservoir, significantly affect capacity.
inside to outside.
blow dry with air from inside to outside.
reused. the element.
achieved by using multiple Element
caused combination
bypassing
strainers.viscosity,
of these. Bypass
can be
dirt-loaded Valve
elements, or a
thoroughly in a suitable solvent, and
n be cleaned and
Bypass valveviscosity,
available
by excess flow
to prevent
rates, high fluidof these.
combination
blow dry withrelief
air from inside to outside.
Cleaning
dirt-loaded elements, or Ana available integral valve
system shutdown. combination of these. parallels the element and is preset to The strainer elements should be
Element media is pleated for long open at a 3 psi pressure drop across cleaned periodically. Remove the
gn Specifications
life.
Design Model Code
Specifications the Code
Model element. Element bypassing can be elements from the reservoir, wash
caused by excess flow rates, high fluid thoroughly in a suitable solvent, and
Elements can be cleaned and
pecifications
ow:
8 reused.
Rated flow:
38 L/min
Model Code
(10 USgpm)
viscosity, dirt-loaded elements, or a blow dry with air from inside to outside.
OF3-08 38 L/min (10 USgpm) combination of these.
0 76 L/min (20 USgpm)
OF3-10 76 L/min (20 USgpm)
238 L/min114 (10 L/min
USgpm) (30 USgpm)
OF3-12 114 L/min (30 USgpm)
676 L/min189 (20 L/min
USgpm) (50 USgpm) 1 2 3 4
OF3-16 189 L/min (50 USgpm) 1 2 3 4
0114 L/min 284 L/min (75 USgpm)
(30 USgpm) 284 L/min (75 USgpm)
OF3-20
4189 L/min 379 L/min (100 USgpm)
(50 USgpm) 379 L/min (100 USgpm)
OF3-24
Design Specifications Model Code
1 2 3 4
284 L/min (75 USgpm)
mpatibility: 1 Model Series 3 Bypass Valve
Fluid compatibility: 1 Model Series 3 Bypass Valve
e379 L/min are
strainers (100compatible
USgpm) with
These strainers are compatible OF3 - Inlet
withstrainers 3RV - 3 psi differential opening pressure
mmonly
ty: used
Rated hydraulic fluids,
flow: used 1 Model Series OF3 - Inlet strainers 3 Bypass Valve 3RV - 3 psi differential opening pressure
all commonly hydraulic fluids, Blank - Omit if not required
dingare
ers phosphate
OF3-08
compatible esters
with and water
38 L/min (10 USgpm) Blank - Omit if not required
including phosphate OF3 esters
- Inlet and water
strainers 3RV - 3 psi differential opening pressure
dused
fluids.
hydraulic fluids, PortUSgpm)
Size (NPTF)
OF3-10
based fluids. 76 L/min 2 (20
2 Port Size (NPTF) Blank - Omit if not required
sphate
nge: esters Cand
-40OF3-12 waterC 114 L/min
to +107 4 Design number
Temp range: -40 C to +107 08 - (30
1” USgpm)
C 4 Design number
(-40 F to +225 F) 2 Port10 Size (NPTF)
1/ USgpm) 08 - 1”
OF3-16 189
(-40 L/min
F to +225 - (50
1
F) 4” 1
10 - 1 /4”
Subject to change. 1 Dimensions
Subject 2to change.
remain
3 4
Dimensions remain
n:-40 C toUnit
+107 C
is supplied with08 12 - 1 1/ ” 4 Design
the number
same for designs 10 through 19.
OF3-20
Filtration: 284
Unit is L/min
- supplied
1” (75
with2USgpm) 1
12 - 1 /2” the same for designs 10 through 19.
(-40 F to149+225micron
F) (100 mesh) 16 - 2”
OF3-24
wire cloth element. 149379
10 1
- L/min ” (100
1 /4(100
micron mesh)USgpm) 16 - 2” Subject to change. Dimensions remain
/20
- 11element.
12cloth - 21/2” the same for designs 10 through 19.
Unit is supplied with wire 2” 20 - 21/12”
:149 micronFluid(100 compatibility:
mesh) 16 - 2” 24 - 3” Model Series 3 Bypass Valve
Material: 24 - 3”
Nylon
wire cloth These
element. strainers20 -are2 1compatible
/ ” with
nt Head stainlessNylon
Pleated steel
2 OF3 - Inlet strainers 3RV - 3 psi differential opening pressure
all commonly
Element used
24
Pleated- 3” hydraulic
stainless fluids,
steel
ght: (Approximate)
Blank - Omit if not required
Nylon Dryincluding phosphate esters and water
weight: (Approximate)
8Pleated 0,3 kg
stainless(0.7 lbs)
steel
based fluids.
OF3-08 0,3 kg (0.7 lbs) 2 Port Size (NPTF)
0
proximate) 0,4 kg (1.0 lbs)
OF3-10 0,4 kg (1.0 lbs) 4 Design number
20,3 kg (0.7Temp
0,6 range:
kg (1.4
lbs) lbs) -40 C to +107 C 08 - 1”
OF3-12 0,6 kg (1.4 lbs)
60,4 kg (1.0
0,8 lbs)
kg (1.8 lbs)
OF3-16
(-40 F
0,8 kg (1.8 lbs)
to +225 F) 10 - 11/4” Subject to change. Dimensions remain
00,6 kg (1.4
1,0 lbs)
kg (2.3 lbs)
OF3-20
Filtration: 1,0Unit
kg (2.3
is lbs)
supplied with 12 - 1 1/ ” the same for designs 10 through 19.
40,8 kg (1.8
1,4 lbs)
kg (3.0 lbs) 2
OF3-24 1,4149
kg (3.0
micronlbs) (100 mesh) 16 - 2”
1,0 kg (2.3 lbs)
wire cloth element. 20 - 21/2”
1,4 kg (3.0 lbs)
Material: 24 - 3”
Head Nylon
Element Pleated stainless steel
Dry weight: (Approximate)
OF3-08 0,3 kg (0.7 lbs)
OF3-10 0,4 kg (1.0 lbs)
OF3-12 0,6 kg (1.4 lbs) 57
OF3-16 0,8 kg (1.8 lbs) 57
OF3-20 1,0 kg (2.3 lbs)
57
OF3-24 1,4 kg (3.0 lbs)

24 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022


InstallationDimensions
Installation Dimensions

Inlet Strainer
Inlet
mm Strainer
(inch)
mm (inch)
C

A
Minimum Screen Area
Model Series cm2 (in2) A (NPTF pipe thread) B C 3,2 ( 0.125)
OF3-08 710 (110) 1” 67,8 (2.67) 135,9 (5.35)
OF3-10 1032 (160)
Minimum Screen Area 11/4” 88,1 (3.47) 174,0 (6.85)
Model Series
OF3-12 cm
2194 2 (in2)
(340) 11/2” A (NPTF pipe thread)
101,6 (4.00) B 250,2 (9.85) C 3,2 ( 0.125)
OF3-16
OF3-08 2194 (340)
710 (110) 2” 1” 101,6 (4.00) 67,8 (2.67)
250,2 (9.85) 135,9 (5.35)
OF3-20 2581 (400) 21/2” 131,3 (5.17) 256,5 (10.10)
OF3-10 1032 (160) 11/4” 88,1 (3.47) 174,0 (6.85)
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)
OF3-12 2194 (340) 11/2” 101,6 (4.00) 250,2 (9.85)
OF3-16 2194 (340) 2” 101,6 (4.00) 250,2 (9.85)
OF3-20 2581 (400) 21/2” 131,3 (5.17) 256,5 (10.10)
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)

Typical Installations

Oil level Disconnect pipe union

Typical Installations to remove strainers

Pump intake
connection

Oil level Disconnect pipe union


to remove strainers

Pump intake
Access opening should be provided so connection Pipe joints submerged
strainers can be removed for cleaning
without draining fluid from tank.

58

Access opening should be provided so Pipe joints submerged


strainers can be removed for cleaning
without draining fluid from tank.

58
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 25
Spin-on Filters
Spin-on Filters
General Data
Spin-on filters
General Datatypically consist of a head mounted
directly in-line with the return piping and a canister
Spin-on filters typically consist of a head mounted These are an effective and economical choice of filter
containing an element which screws onto a threaded
directly in-line with the return piping and a canister where the return line pressure is low and there are no
post. The canister seals to the head to prevent These are an effective and economical choice of filter
containing an element which screws onto a threaded large flow surges with the return line. They are also
leakage. where the return line pressure is low and there are no
post. The canister seals to the head to prevent easily installed without specialty equipment or tooling.
large flow surges with the return line. They are also
leakage.
Applications
easily installed without specialty equipment or tooling.
•Applications
Agricultural equipment -
tractors, spreaders,
• Agricultural
harvesters equipment -
tractors, spreaders,
• Metal forming presses
harvesters
•• Strapping systems
Metal forming presses
•• Strapping
Brush Chippers
systems
•• Turf
Brush Chippers equipment
maintenance
•• Small power unitsequipment
Turf maintenance
• Small power units

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 87

26 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 87
Spin-on Filters Flows to 57 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15

Features and Benefits DESIGN SPECIFICATIONS

• Simple spin-on element Rated flow: 57 L/min 15 USgpm)


design for easy Fluid compatibility: Compatible with most most petroleum oil, water glycol,
maintenance oil-in-water and water-in-oil fluids.
Temp range: -40°C to +107°C (-40°F to +225°F)
• Bypass valves prevent
excessive pressure drop Pressure rating: Operating 7 bar (100 psi)
and accidental element Material: Head Die cast aluminum
collapse Bowl Carbon steel
• Two available ports for Dry weight: 1,0 kg (2.2 lbs.)
use as gauge and/or
diagnostic ports

OFRS 15 * * *** * * * ** 10

1 2 3 4 5 6 7 8 9 10

OFRS15 Series 1 Filter Series - OFRS 5 Fluid Cleanliness Rating 8 Outlet Gauge Port
Filter and Element Target fluid Location (1/8" NPT)
Model Code 2 Flow Rating Code cleanliness level E - Location E
15 -15 USgpm (57 L/min) R03 16/14/12 X - No Gauge
Sample model code: R05 18/16/14
3 Port Type R10 20/18/15
9 Bypass Valve
OFRS15S2R03PBE1010
B - G1 to ISO 228 XXX - no element 10 -Bypass valve set at
P - 1in NPT 0.6 bar (10 psi)
S - 1.312-12 UN SAE-16 25 - Bypass valve set at
straight thd.
6 Pressure Gauge Option 1.7 bar (25 psi)
P - Pressure gauge 0-8 bar
4 Assembly Length (0-120 psi);l p/n 736129 10 Design Number
mm (inch) C - Color Coded Pressure 10 - Standard Design
1 - 194,6 (7.7) Gauge (For use with 1.7
2 - 250,4 (9.9) bar (25 psi) bypass only);
X - no element p/n P-232965-01
X - No Gauge
7 Inlet Gauge Port Location
(1/8" NPT)
B - Location B
X - No Gauge

88 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 27
Spin-on Filters Flows to 57 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15

V019 1 B * R **

1 2 3 4 5 6

V019 Element 1 Series Designation 4 Element Length 6 Fluid Cleanliness Rating


Model Code V019 - Filter element for use mm (inch) Target fluid
with OFRS15 1 - 147 mm (5.8 in) Code cleanliness level
Sample model code: 2 - 203 mm (8.0 in) 03 16/14/12
2 Element Collapse Rating 05 18/16/14
V0191B2R03 5 Element Construction
1 - 10 bar (150 psi) 10 20/18/15
R - R–Pak
3 Seal Material
B - Buna–N

Housing Dimensions
26,9 26,9 .375-16 UNC-2B thd. 19,1 (0.75) min. full thd.
mm (inch) (1.06) (1.06) 2 holes for mounting Mounting screw torque
20-27 Nm (15-20 ft-lb)
B Pressure gauge 3,05R (0.12R) Typ.
connection
E Pressure gauge connection1/8" NPTF pipe thd.
2 locations (see Model Code)
47,8
(1.88) 27,2 (1.07)

13,5
(0.53)
23,9
(0.94) 11,2 9,53/9,78R (0.375/0.385R) Typ.
11,2
(0.44) 7,87R (0.44)
(0.31R)

98,8
Optional pressure gauge (3.89)
49,3 44,4
(1.94) (1.75) Hex. - both ends
24,4
Approx. (0.96)
55,9
(2.20)

Std.
Inlet Outlet (length 1)
port port 194,6
(7.66)
Long
(length 2)
250,4
(9.86)
Std.
(length 1)
170,2
(6.70)
Long
(length 2)
226,1
(8.9)

12,7 (0.50) 97,5 Max.


Clearance required for removal of cartridge (3.84)

28 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 89
Spin-on Filters Flows to 60 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Element Flow Data

OFRS 15 Element Length 1 OFRS 15 Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


5 10 15 20 10 20 30 40
0,6 10 0,6 10
R03
0,5 8 0,5 8
Pressure drop - bar

Pressure drop - bar

Pressure drop - psid


Pressure drop - psid
R03 R05
0,4 6 0,4 6
R05
0,2 4 0,2 4
R10
0,1 R10 0,1
2 2
0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Flow Rate - USgpm Flow Rate - USgpm


0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 26 53
50
45 3,0
40
Pressure drop - bar

Pressure drop - psid


Pressure drop - psid
Pressure drop - bar

35 2,5 36
30
25 2,0
20
15 1,5 22
10
5 0,5
0
9.5 19 28 38 47 57 66 76 85 95
Flow Rate - L/min 50 100 150 200
Flow Rate - L/min

Sample ∆P Calculation : OFRS15S2R03PBE1010 - Filter assembly having '2' length spinon filter element with micron
rating code '03' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing ∆P from graph + Element ∆P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.4 x 0.8/0.9 + 0.08 x 46/32 x 0.8/0.9
= 0.350 + 0.1
= 0.45 bar

90 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 29
Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series

Features and Benefits DESIGN SPECIFICATIONS

• Designed to comply with Rated flow: Length 1 227 L/min (60 USgpm)
ANSI specifications and Length 2 454 L/min(120 USgpm)
ISO cleanliness standards Fluid compatibility Compatible with most petroleum ol, water glycol,
oil-in-water and water-in-oil fluids
• Dual flow path design Temp range: -32°C to +107°C (-25°F to +225°F)
maximizes flow capability
Pressure rating: Operating 14 bar (200 psi)
and service life
Material: Head Aluminum
• Spin-on element make
servicing fast and easy Dry weight: Length 1 7.3 kg (16 lbs)
Length 2 8.6 kg (19 lbs)
• High efficiency
replacement elements in
standard configurations
(R-Pak) to meet Target
Cleanliness Levels
HS22 1 FE * * N B * * **

1 2 3 4 5 6 7 8 9 10

HS22 Series 1 Filter Series - HS22 5 Indicator options 9 Element Construction


Filter and Element 1 - No indicator R - R-Pak (code 3, 5,10, 20)
Model Code 2 Element Collapse Rating 2 - 13.7 bar (200 psi) gauge W- Water Removal (10, length
1 - 150 psi Low Pressure 4 - 4 bar (60 psi) gauge 2 only)
Sample model code: X - No Element
3 Port options 6 Receptical
HS22FED32NB2R05 N - None 10 Fluid cleanliness rating
FE - 1-1/2" SAE 4 bolt Flange
Code 61 (UNC) Target fluid
7 Seal material Code cleanliness level
B - Buna-N 03 16/14/12 or better
4 Valve options
05 18/16/14 or better
3 - Bypass set at 1.7 bar 8 Assembly Length
(25 psi) cracking pressure 10 20/18/15 or better
mm (inch) 20 22/19/16 or better
4 - Bypass set at 3 bar (50
1 - 253 (10)
psi) cracking pressure XX No Element
2 - 355 (14)
X - No Element

30
104 EATON Vickers Filtration
EATON Filtration Catalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007
Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series

V021 1 B * * **

1 2 3 4 5 6

V021 Element 1 Filter Element 3 Seal Material 6 Fluid Cleanliness Rating


Model Code V021 - Filter element for use B - Buna-N Target fluid
with HS22 and OFRS- cleanliness Element
Sample model code: 60 series filters (R-Pak 4 Canister Length Code level construction
construction only) mm (inch) 03 16/14/12 R-Pak
V0211B1R03
1 - 184 (7) 05 18/16/14 R-Pak
2 Element Collapse Rating 2 - 286 (11) 10 20/18/15 R-Pak or
1 - 10 bar (150 psi) Low water
Pressure 5 Element Construction removal
R - R-Pak (code 3, 5,10, 20) 20 22/19/16 R-Pak
W- Water Removal (Code 10,
length 2 only)

Housing Dimensions 286,0


mm (inch) (11.26)

60 165,5
146 (6.52)
(2.36) (5.75)

171,0
(6.73)
Mounting Holes
3/8"-16 - 4 Places

40,0
286 (1.57)
(11.26)

35,5 Refer to
(1.40) Model Code

128,3
(5.05)

EATON Vickers Filtration


EATON FiltrationCatalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007 31
105
Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

Element Flow Data

HS22 R-Pak Element Length 1 HS22 R-Pak Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


7 20 33 13 40 66
R03 R03

Pressure drop - psid


Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


26 79 26 79
1,2
5,0 73

Pressure drop - psid


1,0 15
Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

50 PSID Valve 65
0,8 4,0
9 3,0 45 44
0,6
0,4 2,0 25 PSID Valve
0,2 3 1,0 15

0 100 200 300 400 0 100 200 300 400


Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : HS221SD32NB2RO5 - Filter assembly having '2' length filter element with micron rating code
'05' at 250 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing ∆P from graph + Element ∆P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 0.37 x 46/32 x 0.8/0.9
= 0.260 + 0.47
= 0.73 bar

32
106 EATONVickers
EATON Vickers Filtration
Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022
Pressure Filters

General Data
Pressure filters are used to protect downstream In some applications, pressure filters are used as
components from contamination levels beyond the isolation filters to protect specific components such
recommended cleanliness target. Because they are as proportional or servo valves. Typically these
typically sized for the output of the pump, pressure filters filters are non-bypass and employ elements that are
tend to be smaller than return line filters when cylinders capable of withstanding full system differential
are present. In systems using accumulators, pressure pressure without collapsing. While these filters are
filters must be sized according to the large effective flow sized to handle only a specific components' required
rates present during parts of the duty cycle. flow, the use of high collapse elements result in a
higher cost than elements used in housings with
bypass valves. Most isolation filters are direct-
mounted beneath the valve which can save space
as well as reduce plumbing costs.

Applications
• Paper Mills • Test and simulation
• Steel Mills equipment
• Injection molding • Entertainment stage
machines equipment
• Motion bases • Hydrostatic drives
• Sawmill equipment • Power generation
turbine control systems
• Flight simulators

EATON Vickers Filtration


EATON FiltrationCatalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007 33
107
Pressure Filters Flows to 19 L/min (5 USgpm)
Pressures to 200 bar (3,000 psi)
ECF Series

Features and Benefits DESIGN SPECIFICATIONS

• Integrated throwaway Rated flow: 19 L/min (5 USgpm)


element which is screwed Fluid compatibility: Compatible with all petroleum-/oil-based and synthetic fluids.
into the manifold port for Not rated for use with fluoro-rubber or ethylene propylene seals.
last chance filtration
Temp range: -30°C to +121°C (-22°F to 250°F)
Pressure rating: Operating 200 bar (3000 psi)
Cavity: BC20-S3
Material: Head Aluminum
Bowl Aluminum
Dry weight: (Approximate) 0,11 kg (0.25 lbs)

ECF 1 SB 1 J 3 * V ***

1 2 3 4 5 6 7 8 9

ECF Series 1 Filter Series - ECF Assembly Length


6
Filter and Element mm (inch)
Model Code 2 Element Collapse Rating 3 - 80.2 (3.16)
1 - 17 bar (250 psi) low
Sample model code: collapse 7 Element Construction
C - Standard construction
ECF1SB1J3CV025 3 Port Options M - Wire screen
SB - 1.312-12 UN SAE-16
straight thread 8 Seal Material
V - Viton-A
4 Valve Options
1 - Non-Bypass 9 Fluid Cleanliness
(Screw directly into cavity) Fluid
Cleanliness Element
Code Rating Construction
5 Indicator Options
015 20/18/15 C-Pak
J - No indicator
025 Wirescreen
100 Wirescreen

34
108 EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007
Pressure Filters Flows to 19 L/min (5 USgpm)
Pressures to 207 bar (3,000 psi)
ECF Series

Housing Dimensions
mm (inch)
Ø48.9
(Ø1.929)
Spotface
35.5
(1.399) 1.5
HEX
1 5/16-12UN-2B IN.
SAE-16 PORT
19.05
Ø19.05 0.76 3.3 (0.75)
(Ø0.75) (0.03) (0.13)
Min. Full Thread

INLET 61.0 (2.400)


45° 68.6 (2.710) 80.2 66.9
INLET PORT BETWEEN
20.3 - 50.8 (0.80-2.00) FROM TOP

(3.157) (2.634)
20°

Ø25.3
(Ø.998)

Ø19.05 (Ø0.75) Pilot Drill


1 5/16 - 12UN-2A IN.
Ø25.5 (Ø1.003)
Ø31.3 (Ø1.234)

OUTLET

Housing/Element Flow Data

Flow versus pressure drop:


150 SUS (32 cSt) oil with specific gravity of <0.9

ECF15 ECF 25/150


Flow Rate - USgpm Flow Rate - USgpm
0 1 2 3 4 5 6 0 2 4 6 8 10 12 14 16 18
1,50 1,50
20 20
Pressure drop - psid

Pressure drop - psid

1,25
Pressure drop-bar

Pressure drop-bar

1,25
16 16
1,00 1,00
0,75 12 12
0,75
0,50 8 8
0,50
0,25 4 0,25 4
0 0 0 0
0 4 8 12 16 20 24 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72
Flow Rate - L/min Flow Rate - L/min

EATON
EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007 35
109
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series

Features and Benefits DESIGN SPECIFICATIONS

• Beta Ratio: βx(c) = 1000 Rated flow: Length 1 45 L/min (12 USgpm)
to ISO 16889 Length 2 91 L/min (24 USgpm)

• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual, electrical, and Pressure rating: Operating 280 bar (4000 psi)
electrical indicators with Fatigue 280 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Carbon Steel
• Conforms to HF2 Dry weight: Length 1 4,6 kg (10.1lbs)
(Approximate) Length 2 5,9 kg (134lbs)
automotive specifications
• Compact design for use with
servo and proportional valves
• Manifold mounting option
for system flexibility
• High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HF2P * ** * ** * * * **
• High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications

HF2P Series 1 Filter Series - HF2P RB - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Filter and Element Brad Harrison (70 psi), Hirschmann
RH - Electrical 2 bar (30 psi), w 115 volt light
Model Code 2 Element Collapse Rating Hirschmann UL - Electrical 4.9 bar (70 psi),
1 - 17 bar (250 psi) Low RJ - Electrical 2 bar (30 psi), Hirschmann w 230 volt
Sample model code: Collapse Hirschmann w 24 volt light
4 - 207 bar (3000 psi) High light
HF2P1SA4LNB2C05 Collapse RK - Electrical 2 bar (30 psi), 6 Seal Material
NOTE: Use 1 only with bypass valve or Hirschmann w 115 volt B - Buna-N
monitored P indicator. light V - Viton-A
RL - Electrical 2 bar (30 psi),
3 Port Options Hirschmann w 230 volt 7 Assembly Length
BA - G3/4 to ISO 228 light
SA - 1.062 - 12UN SAE-12 TB - Electrical 7.9 bar mm (inch)
(3/4" tube) (115 psi), Brad Harrison 1 - 211.9 (8.3)
WS - Subplate mounting TH - Electrical 7.9 bar 2 - 304.9 (12.0)
(115 psi), Hirschmann
4 Valve Options TJ - Electrical 7.9 bar 8 Element Construction
(115 psi), Hirschmann C - 17 bar (250 psi)
1 - Non-Bypass
w 24 volt light Low Collapse
4 - Bypass set at 2.9 bar TK - Electrical 7.9 bar
(43 psi) cracking pressure H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
6 - Bypass set at 6 bar w 115 volt light
(90 psi) cracking pressure X - no element
TL - Electrical 7.9 bar (115
psi), 9 Fluid Cleanliness Rating
5 Indicator Options Hirschmann w 230 volt
Target fluid
AN - Visual 4.9 bar (70 psi), light Code cleanliness level
No Connector UB - Electrical 4.9 bar
JN - No Indicator (plug), (70 psi), Brad Harrison 03 16/14/12 or better
No Connector UH - Electrical 4.9 bar 05 18/16/14 or better
LN - Visual 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
No Connector UJ - Electrical 4.9 bar
20 22/19/16 or better
ON - Visual 7.9 bar (115 psi), (70 psi), Hirschmann
w 24 volt light XX no element
No Connector

36
116 EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
V304 * * * * **

1 2 3 4 5 6

V304 Element 1 Filter Element 3 Seal Material 5 Element Construction


Model Code V304 - For use with HF2P B - Buna-N C - C-Pak (code 03, 05, 10, 20)
series filters V - Viton-A H - H-Pak (code 03, 05, 10)
Sample model code:
2 Element Collapse Rating 4 Element Length 6Fluid Cleanliness Ratings
V3041B1C05
1 - 17 bar (250 psi) mm (inch) Target fluid
(C-Pak only) 1 - 101 (4) Code cleanliness level
5 - 207 bar (3000 psi) 2 - 203 (8) 03 16/14/12 or better
(H-Pak only) 05 18/16/14 or better
10 20/18/15 or better
20 22/19/16 or better

Housing Dimensions
mm (inch)
88.9
Subplate Mounting Outlet (3.50) Inlet Indicator Plug 21.4
7 44.5
(0.28) (1.75) (.08)
15.9
ø25.4 (0.63)
(1.00) 52 ø86
80 (2.05) (3.39)
(3.15)
ø17.5 31.8
(0.69) (1.25)

31.8 17 104
ø8.6 (0.34) thru (1.25) (0.67) (4.09)
4PL's
5/16-18UNC x 4.25 long
grade 8 bolts for 0.5
engagement are recommended
(4 req'd). Torque 9-12lb-ft (12-16Nm)

27 HEX 79.4
(1.06) (3.13)
7 24.2
(0.95) Inlet Outlet
(0.28)
ø6.75
(0.27)
96 98
(3.78) (3.86)

Refer to
Model Code

24 HEX
(0.95)

75 (2.96)
ø76.2 Clearance for
(3.00) Element Removal

EATON
EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007 37
117
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF2P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 1 0.037 (2.046) 0.032 (1.735) 0.017 (0.924) 0.010 (0.531)


2 0.018 (1.011) 0.016 (0.858) 0.008 (0.457) 0.005 (0.262)
H - pak 1 0.044 (2.396) 0.031 (1.688) 0.019 (1.026) xxx
2 0.021 (0.865) 0.015 (0.820) 0.009 (0.499) xxx

Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass Valve


Flow Rate - USgpm Flow Rate - USgpm
11 21 0 2 4 6 8 10 12 14 16 18 20
25,0
1,2 17
322.5
Pressure drop - psid

Pressure drop - psid


20,0
Pressure drop-bar

Pressure drop-bar

0,8 272.5

15,0 222.5

172.5
0,4 6
10,0
122.5

0 5,0 72.5
0 20 40 60 80 100 0 10 20 30 40 50 60 70 80
Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : HF2P1SA4LNB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 50 x 0.016 x 46/32 x 0.8/0.9
= 0.220 + 1.01
= 1.23 bar

38
118 EATON Vickers Filtration
EATON Filtration Catalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007
Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series

Features and Benefits DESIGN SPECIFICATIONS

• Beta Ratio: βx(c) = 1000 Rated flow: Length 5 68 L/min (18 USgpm)
to ISO 16889 Length 7 113.5 L/min (30 USgpm)

• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual, electrical, and Pressure rating: Operating 276 bar (4000 psi)
electrical indicators with Fatigue 276 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Steel
• High efficiency Dry weight: Length 5 3,9 kg (8.3 lbs)
(Approximate) Length 7 4,5 kg (9.9 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
• Poppet type leak by-pass
valve construction

MF2P 1 SA 5 ** * * * **

1 2 3 4 5 6 7 8 9

MF2P Series 1 Filter Series - MF2P 5 Indicator Options 7 Assembly Length


Filter Assembly Model AN - Visual 4.9 bar (70 psi), mm (inch)
Code 2 Element Collapse Rating No Connector 5 - 210 (8.27)
1 - 17 bar (250 psi) Low JN - No Indicator (plug), 7 - 263 (10.36)
Sample model code: Collapse No Connector
UB - Electrical 4.9 bar 8 Element Construction
MF2P1SA5ANB5C05 3 Port Options (70 psi), Brad Harrison C - 250 psi Low Collapse
SA - 1.062 - 12UN SAE-12 UJ - Electrical 4.9 bar X - no element
(3/4" tube) (70 psi), Hirschmann
w 24 volt light 9 Fluid Cleanliness Rating
4 Valve Options UK - Electrical 4.9 bar Target fluid
(70 psi), Hirschmann Code cleanliness level
5 - Bypass set at 100 psi
w 115 volt light 03 16/14/12 or better
(7 bar) cracking pressure
UL - Electrical 4.9 bar (70 psi),
05 18/16/14 or better
Hirschmann w 230 volt
light 10 20/18/15 or better
UH - Electrical 4.9 bar 20 22/19/16 or better
(70 psi), Hirschmann XX no element
6 Seal Material
B - Buna-N
V - Viton-A

EATON Vickers Filtration


EATON Filtration Catalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007 39
119
Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series

V0512 * * C **

1 2 3 4 5

V0512 Element 1Filter Element 4 Element Construction


Model Codes V0512 - For use with MF2P C - C-Pak (code 03, 05, 10, 20)
series housings
Sample model code: 9 Fluid Cleanliness Rating
2 Seal Material Target fluid
V0512B5C05 Code cleanliness level
B - Buna-N
V - Viton-A 03 16/14/12 or better
05 18/16/14 or better
3 Element Length 10 20/18/15 or better
mm (inch)
20 22/19/16 or better
5 - 117 (5)
7 - 169 (7)

Housing Dimensions ø 41
92 (1.61)
mm (inch) 6
(3.62) Clogging
(0.24) Indicator
1 1/16-12 UN
Port

35 35
(1.38) (1.38)

90
(3.54)

Length 5
204
(8.03)

Length 7
257
(10.12)

SW 27

55 ø 76,2
(2.17) (3.00)
55 ø 86
(3.39)
OUTLET R9

INLET
ø 45 40
(1.37) (1.57)

mounting threads
3/8-16 UNC

40
120 EATONVickers
EATON Vickers Filtration
Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022
Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of < 0.9

MF2P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 5 0.014 (0.750) 0.011 (0.602) 0.008 (0.443) 0.005 (0.263)


7 0.009 (0.509) 0.008 (0.411) 0.005 (0.290) 0.003 (0.169)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass
Flow Rate - USgpm Flow Rate - USgpm
0 5 10 15 20 25 30 0 2 4 6 8 10 12 14
16 20,0
1,0 272.5
14

Pressure Drop - psid


247.5
Pressure Drop - psid
Pressure Drop - bar

Pressure Drop - bar

0,6 12 15,0 222.5


10 197.5
0,5
8 172.5
0,4 6 10,0 147.5
4 122.5
0,2 97.5
2
0,0 0 5,0 72.5
0 15 30 45 60 75 90 105 0 10 20 30 40 50 60
Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : MF2P1SA5UNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 50 x 0.011 x 46/32 x 0.8/0.9
= 0.260 + 0.69
= 0.95 bar

EATONVickers
EATON Vickers Filtration
Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022 41
121
Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series

Features and Benefits DESIGN SPECIFICATIONS

• Beta Ratio: βx(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 568 L/min (150 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual and electrical Pressure rating: Operating 345 bar (5000 psi)
indicators with lamp Fatigue 345 bar (5000 psi)
options for system Material: Head Ductile Iron
design flexibility Bowl Carbon Steel
• Conforms to HF4 Lid Ductile Iron
specifications Dry weight: Length 3 28,8 kg (63.4 lbs)
(Approximate) Length 6 38,7 kg (85.3 lbs)
• Fatigue rated to 5000 psi Length 7 51,5 kg (113.6 lbs)
for maximum reliability in
rugged applications
• Top loading design to
ease maintenance and
minimize spillage
• Multiple filter element HF4P * ** * ** * * * **
lengths for design flexibility
• High efficiency 1 2 3 4 5 6 7 8 9
replacement elements in JN - No Indicator (plug), UL - Electrical 4.9 bar (70 psi),
standard configurations
1 Filter Series - HF4P
No Connector Hirschmann w 230 volt
(C-Pak) to meet Target RB - Electrical 2 bar (30 psi), light
Cleanliness Levels
2 Element Collapse Rating
Brad Harrison UH - Electrical 4.9 bar
1 - 10 bar (150 psi) Low RJ - Electrical 2 bar (30 psi), (70 psi), Hirschmann
• High collapse elements
Collapse Hirschmann w 24 volt
available for non-bypass 4 - 207 bar (3000 psi)
applications light 6 Seal material
High Collapse RK - Electrical 2 bar (30 psi), B - Buna-N
Series Hirschmann w 115 volt V - Viton-A
3 Port options light
Filter and Element
BD - G11/2 to ISO 228 RL - Electrical 2 bar (30 psi), 7 Assembly Length
Model Code ME - 11/2" SAE 4 bolt Flange Hirschmann w 230 volt mm (inch)
Code 61 (M12 x 1.75) light 3 - 447 (17.6)
Sample model code: MR - 11/2" SAE 4 bolt Flange RH - Electrical 2 bar (30 psi), 6 - 685.3 (27)
HF4P1SD4LNB6C05 Code 62 (M16 x 2.0) Hirschmann 7 - 923.5 (36.4)
SD - 1.875 - 12 UN SAE-24 TB - Electrical 7.9 bar
str. Thd. (11/2" tube) (115 psi), Brad Harrison 8 Element construction
FE - 11/2" SAE 4 bolt Flange TJ - Electrical 7.9 bar
Code 61 (UNC) C - 10 bar (150 psi)
(115 psi), Hirschmann
FR - 11/2" SAE 4 bolt Flange Low Collapse
w/ 24 volt light
Code 62 (UNC) H - 207 bar (3000 psi)
TK - Electrical 7.9 bar High Collapse
WS - Subplate mounting (115 psi), Hirschmann
X - no element
w/ 115 volt light
4 Valve options TL - Electrical 7.9 bar 9 Fluid cleanliness rating
1 - Non-Bypass (115 psi), Hirschmann
Target fluid
4 - Bypass set at 2.9 bar w/ 230 volt light Code cleanliness level
(43 psi) cracking pressure TH - Electrical 7.9 bar
6 - Bypass set at 6 bar (115 psi), Hirschmann 03 16/14/12 or better
(90 psi) cracking pressure UB - Electrical 4.9 bar 05 18/16/14 or better
(70 psi), Brad Harrison 10 20/18/15 or better
5 Indicator options UJ - Electrical 4.9 bar 20* 22/19/16 or better
AN - Visual 4.9 bar (70 psi), (70 psi), Hirschmann XX no element
No Connector w 24 volt light
* C-Pak only
LN - Visual 2 bar (30 psi), UK - Electrical 4.9 bar
No Connector (70 psi), Hirschmann
w 115 volt light

42 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 125
Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series
V405 * * * * **

1 2 3 4 5 6

V405 Element 1 Filter Element - V405 4 Element Length 6 Fluid Cleanliness Rating
model code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) 03 16/14/12
4 - 206.9 bar (3000 psi) 7 - 686 (27) 05 18/16/14
Sample model code:
High Collapse 10 20/18/15
V4051B3C03 NOTE: Use 1 only with bypass valve or 5 Element Construction
monitored delta P indicator. 20 22/19/16
C - C-Pak (code 03, 05, 10,
20)
3 Seals H - H-Pak (code 03, 05, 10)
B - Buna-N
V - Viton-A
Housing Dimensions Drain Plug
25.4 (1.00) 50.8
mm (inch) Hex 14.2 (2.00)
(0.56) 7.9 Outlet
thru (0.31)
57.2
158.8 4 PL'S (2.25)
(6.25)
79.4
(3.13) 114.3
(4.50)
Vent Plug
73 Inlet
(2.88) 146.1 Refer to
(5.75) Model Code Indicator
63.5 Port
(2.50)
127
(5.00)
133.4
22.4 (5.25) View X - Subplate Mounting
(0.88) 66.7
(2.63)

Inlet & Outlet = 31.8 (1.25)


O-ring = 2 x 1. .139

Refer to
Model
Code

Inlet (SAE-24 or G 1.5")


Outlet
Port on opposite face

70
(2.76)

35.1
Bolt Thread (1.38)
View X
E D C
A B C D E
mm mm mm mm mm
(inch) (inch) (inch) (inch) (inch)
B
A ME 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
MR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
FE 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
FR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)

126 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 43
Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF4P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 3 0.003 (0.168) 0.003 (0.140) 0.001 (0.078) 0.001 (0.044)


6 0.001 (0.080) 0.001 (0.066) 0.001 (0.037) 0.001 (0.021)
7 0.001 (0.051) 0.001 (0.043) 0.001 (0.024) 0.001 (0.013)
H -pak 3 0.004 (0.206) 0.003 (0.145) 0.002 (0.088) xxx
6 0.002 (0.096) 0.001 (0.068) 0.001 (0.041) xxx
7 0.001 (0.062) 0.001 (0.044) 0.001 (0.026) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
26 79 0 10 20 30 40 50 60 70 80 90
1,00 15 11,0 157

10,0 147
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

0,75
137
9,0
127
0,50 7
8,0 117
107
0,25 7,0
97
0 6,0 87
0 100 200 300 400
0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

Sample ∆P Calculation : HF4P1SD4LNB6C05 - Filter assembly having '6' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.220 + 0.25
= 0.47 bar

44 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 127
Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 410 bar (6,000 psi)
HF3P Series

Features and Benefits


• Beta Ratio: βx(c) = 1000
to ISO 16889
• Designed to comply with
ANSI specifications and DESIGN SPECIFICATIONS
ISO cleanliness standards Rated flow: Length 1 106 L/min (28 USgpm)
• Visual, electrical, and Length 2 208 L/min (55 USgpm)
electrical indicators with Length 4 344 L/min (91 USgpm)
lamp options for system Length 5 454 L/min (120 USgpm)
design flexibility Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
• Conforms to HF3 water-in-oil fluids. Optional seals available for phosphate esters.
automotive specifications Temp range: -26°C to +121°C (-15°F to +250°F)
• Fatigue rated to 6000 psi Pressure rating: Operating 410 bar (6000 psi)
for maximum reliability in Fatigue 410 bar (6000 psi)
the most rugged Material: Head Ductile iron
applications Bowl Carbon Steel
• Reverse flow valve option Dry weight: Length 1 20,3 kg (44.8lbs)
for hydrostatic (Approximate) Length 2 22,5 kg (49.5lbs)
(Approximate) Length 4 28,5 kg (62.9lbs)
transmission applications (Approximate) Length 5 43,4 kg (95.7lbs)
• Multiple filter element
lengths for design flexibility HF3P * ** * ** * * * **
• High efficiency
replacement elements in 1 2 3 4 5 6 7 8 9
standard configurations
(C-Pak) to meet Target 1 Filter Series - HF3P 5 Indicator Options UH - Electrical 4.9 bar
Cleanliness Levels (70 psi), Hirschmann
AN - Visual 4.9 bar (70 psi),
2 Element Collapse Rating
UJ - Electrical 4.9 bar
• High collapse elements No Connector
(70 psi), Hirschmann
available for non-bypass 1 - 17 bar (250 psi) Low JN - No Indicator (plug),
w 24 volt light
applications Collapse No Connector
UK - Electrical 4.9 bar
4 - 207 bar (3000 psi) High KN - Visual 1 bar (15 psi),
(70 psi), Hirschmann
Collapse No Connector
w 115 volt light
LN - Visual 2 bar (30 psi),
HF3P Series UL - Electrical 4.9 bar (70 psi),
3 Port Options No Connector
Filter and Element Hirschmann w 230 volt
BB - G1 to ISO 228 ON - Visual 7.9 bar (115 psi),
Model Code light
BD - G1-1/2 to ISO 228 No Connector
ME - 1-1/2" SAE 4 bolt Flange RB - Electrical 2 bar (30 psi), 6 Seal Material
Sample model code: Code 61 (M12 x 1.75) Brad Harrison
RH - Electrical 2 bar (30 psi), B - Buna-N
HF3P1SB4LNB2C05 MJ - 2" SAE 4 bolt Flange V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
MU - 2" SAE 4 bolt Flange RJ - Electrical 2 bar (30 psi),
Hirschmann w 24 volt
7 Assembly Length
Code 62 (M20 x 2.5)
light mm (inch)
SB - 1.312 - 12 UN SAE-16
RK - Electrical 2 bar (30 psi), 1- 230 (9.1)
str. Thd. (1" tube)
Hirschmann w 115 volt 2- 293 (11.5)
SD - 1.875 - 12 UN SAE-24
Reverse Flow Non-bypass light 4- 414 (16.3)
str. Thd. (1-1/2" tube)
(Valve Option 8) RL - Electrical 2 bar (30 psi), 5- 569 (22.4)
FE - 11/2" SAE 4 bolt Flange
Code 61 (UNC) Hirschmann w 230 volt
light
8 Element Construction
FJ - 2" SAE 4 bolt Flange
Code 61 (UNC) TB - Electrical 7.9 bar C - 17 bar (250 psi)
FU - 2" SAE 4 bolt Flange (115 psi), Brad Harrison Low Collapse
Code 62 (UNC) TH - Electrical 7.9 ba H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
4 Valve Options TJ - Electrical 7.9 bar X - no element
(115 psi), Hirschmann
1- Non-Bypass 9 Fluid Cleanliness Rating
w 24 volt light
4- Bypass set at 2.9 bar
(43 psi) cracking pressure TK - Electrical 7.9 bar Target fluid
Reverse Flow Bypass (115 psi), Hirschmann Code cleanliness level
6- Bypass set at 6 bar
(Valve Option 9) w 115 volt light 03 16/14/12 or better
(90 psi) cracking pressure
8- Reverse Flow Valve TL - Electrical 7.9 bar (115 05 18/16/14 or better
psi), 10 20/18/15 or better
Non-Bypass*
Hirschmann w 230 volt
9- Reverse Flow Valve 2.9 20 22/19/16 or better
light
bar (43 psi) Bypass* (C-Pak only)
* Reverse flow bypass available with BD, UB - Electrical 4.9 bar
(70 psi), Brad Harrison XX no element
MU, SD and FU ports only.

128 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 45
Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 420 bar (6,000 psi)
HF3P Series V602 * * * * **

1 2 3 4 5 6

V602 Element 1 Filter element 3 Seal material 5 Element construction


Model Code V602 - For use with HF3P, B - Buna-N C - C-Pak (code 03, 05, 10,
series filters V - Viton-A 20)
Sample model code: H - H-Pak (code 03, 05, 10)
2 Element collapse rating 4 Element length
V6021B1C03 6 Fluid cleanliness rating
1 - 17 bar (250 psi) Collapse mm (inch)
4 - 207 bar (3000 psi) High 1- 101 (4) Target fluid
Collapse 2- 203 (8) Code cleanliness level
NOTE: Use 1 only with bypass valve. 4- 330 (13) 03 16/14/12 or better
5- 406 (16) 05 18/16/14 or better
10 20/18/15 or better
Housing Dimensions 166.9 20 22/19/16 or better
mm (inch) (6.57)
60 Inlet & Outlet Porting
(2.36)
30 1 1/2" or 2" SAE
(1.18) flange code 61,
inch or metric

159 57.5 1 1/2" or 2" SAE


(6.26) (2.26) flange code 62,
115 inch or metric
(4.53)

1
/2-20UNF-2B in. X 17 (0.67)deep 4 Places
8.4 Indicator Plug
(0.33)
52 SAE-16, 24, G1 OR G1 1/2
(2.05)

16" Housing

Refer to
Model Code
117
(4.61)

ø152
(5.98)
427 Clearance required
Drain Plug G 1/2 ø130.2 (16.8) for element removal
95 (3.74) (5.13)
Clearance required for element removal

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
53 159 0 10 20 30 40 50 60 70 80 90
2,0 30 11,0 157

10,0 147
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

1,5
137
9,0
127
1,0 15
8,0 117
107
0,5 7,0
97
0 6,0 87
0 200 400 600 800 0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

46 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 129
Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 420 bar (6,000 psi)
HF3P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

Element Flow Data

HF3P Filter Elements

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.011 (0.589) 0.009 (0.499) 0.005 (0.266) 0.003 (0.153)


2 0.005 (0.288) 0.004 (0.241) 0.002 (0.135) 0.001 (0.076)
4 0.003 (0.175) 0.003 (0.146) 0.001 (0.082) 0.001 (0.046)
5 0.002 (0.132) 0.002 (0.110) 0.001 (0.061) 0.001 (0.034)
H -pak 1 0.017 (0.936) 0.012 (0.659) 0.007 (0.401) xxx
2 0.008 (0.455) 0.006 (0.320) 0.004 (0.195) xxx
4 0.005 (0.273) 0.004 (0.192) 0.002 (0.117) xxx
5 0.004 (0.206) 0.003 (0.145) 0.002 (0.088) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Sample ∆P Calculation : HF3P1SB4LNB2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.12 x 0.8/0.9 + 100 x 0.001 x 46/32 x 0.8/0.9
= 0.100 + 0.127
= 0.22 bar

130 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 47
Accessories
Differential
Indicators
DESIGN SPECIFICATIONS

Material: PV/PE Series Aluminum


PHV/PHE Series Stainless Steel
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Optional seals available for phosphate esters.
Installation Torque: PV/PE Series 33 Nm (24 lbs-ft)
PHV/PHE Series 100 Nm (74 lbs-ft)
Temp range: -26°C to +120°C (-15°F to +250°F)
Switch Rating (all models): 3A@24VDC
5A@250VAC
Dry weight: (Approximate) PV 55g (0.1lbs)
PHV 110g (0 2lbs)
PE 150g (0.3lbs)
PHE 250g (0.6lbs)
Pressure rating: PV/PE Series 210 bar (3000PSI)
PHV/PHE Series 420 bar (6000PSI)

** ** V * ***

1 2 3 4 5

Indicator Model Code 1 Indicator type and 3 Seal material


pressure rating V - Viton-A
PV - visual 210 bar (3000psi)
PE - electrical 210 bar (3000psi) 4 Connector
PHV- visual 420 bar (6000psi) B - Brad Harrison 5 Pin
PHE - electrical 420 bar (6000psi) H - Hirschmann
N - None (use with PV indicators)
2 Pressure setting
1B - 1 bar (15psid) 5 Light option
2B - 2 bar (30psid) L24 - 24 Volt Lamp
5B - 5 bar (75psid) L115 -115 Volt Lamp
8B - 8 bar (115psid) L230 -230 Volt Lamp

INDICATOR OPTIONS (3000 PSI - USE WITH FILTER MODELS HV6R, HV3R)

Filter Assembly
Description Model Code Letters
POPUP VISUAL 15 psi PV 1B VN KN
POPUP VISUAL 30 psi PV 2B VN LN
POPUP VISUAL 70 psi PV 5B VN AN
BRAD HARRISON 5 PIN ELECTRICAL 15 psi PE 1B V B QB
BRAD HARRISON 5 PIN ELECTRICAL 30 psi PE 2B V B RB
BRAD HARRISON 5 PIN ELECTRICAL 70 psi PE 5B V B UB
HIRSCHMANN ELECTRICAL 15 psi PE 1B V H QH
HIRSCHMANN ELECTRICAL 30 psi PE 2B V H RH
HIRSCHMANN ELECTRICAL 70 psi PE 5B V H UH
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L24 PE 1B V H L24 QJ
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L24 PE 2B V H L24 RJ
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L24 PE 5B V H L24 UJ
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L115 PE 1B V H L115 QK
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L115 PE 2B V H L115 RK
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L115 PE 5B V H L115 UK
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L230 PE 1B V H L230 QL
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L230 PE 2B V H L230 RL
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L230 PE 5B V H L230 UL

48 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 147
Accessories
Differential INDICATOR OPTIONS (6,000 PSI - USE WITH FILTER MODELS HF2P, HF3P, HF3PS, HF4, MF2P)

Indicators Description Model


Filter Assembly
Code Letters
Popup Visual 30psi PHV 2B VN LN
Popup Visual 70 Psi PHV 5B VN AN
Popup Visual 115 Psi PHV 8B VN ON
Brad Harrison 5 Pin Electrical 30 Psi PHE 2B V B RB
Brad Harrison 5 Pin Electrical 70 Psi PHE 5B V B UB
Brad Harrison 5 Pin Electrical 115 Psi PHE 8B V B TB
Hirschmann Electrical 30 Psi PHE 2B V H RH
Hirschmann Electrical 70 Psi PHE 5B V H UH
Hirschmann Electrical 115 Psi PHE 8B V H TH
Hirschmann Visual Electrical 30 Psi - L24 PHE 2B V H L24 RJ
Hirschmann Visual Electrical 70 Psi - L24 PHE 5B V H L24 UJ
Hirschmann Visual Electrical 115 Psi - L24 PHE 8B V H L24 TJ
Hirschmann Visual Electrical 30 Psi - L115 PHE 2B V H L115 RK
Hirschmann Visual Electrical 70 Psi - L115 PHE 5B V H L115 UK
Hirschmann Visual Electrical 115 Psi - L115 PHE 8B V H L115 TK
Hirschmann Visual Electrical 30 Psi - L230 PHE 2B V H L230 RL
Hirschmann Visual Electrical 70 Psi - L230 PHE 5B V H L230 UL
Hirschmann Visual Electrical 115 Psi - L230 PHE 8B V H L230 TL
Indicator Plug 3040056 —

Differential Indicator Dimensional Schematics

PE * B V B PV * B VN
PHE * B V B
58 ø27
(2.28) (1.06)

A WHITE 1

3 RED
GREEN 2 27 HEX
P
1
2 ORANGE 34
BLACK 5
63.5 (1.06)
(2.50)
B
62.5 29
(2.46) 100.6 Schematic
(1.14)
(3.96)

G 1/2

27 G 1/2
(1.06)

PE * B V H PE * B V H L * *
PHE * B V H PHE * B V H L * *
70
(2.76)
51 A )
(2.00) 3
A ) 3P )
3 ) 1
3 1 )
P
2 )
1 1 )
) B
2

2 2
B )
60.2 111.4 Schematic
70
(2.76) 108.1 (2.37) (4.39)
(4.26) Schematic

27 G 1/2
27 G 1/2 (1.06)
(1.06)

148 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 DecemberEATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 49
Accessories
Static
Indicators

PLV 2B V H L24

1 2 3 4 5

Indicator Model Code 1Indicator type and 3 Seal Material


pressure rating V - Viton-A
PLV - Visual
PLE - Electrical 4 Connector
SLV - Visual B - Brad Harrison 5 Pin
SLE - Electrical N - Hirschmann
2 Pressure setting H - None
1B - 1 bar (15psid) 5 Light Options
2B - 2 bar (30psid)
5B - 5 bar (75psid) L24 - 24 Volt Lamp
1.4B - 1.4 bar (20psid) L115 - 115 Volt Lamp
L230 - 230 Volt Lamp
N - None

INDICATORS FOR ORFM


INDICATORS FOR ORFM SERIES EATON SERIES-LENGTH 5-7; EATON
LENGTH 1-4 & HF4RT SERIES MODEL CODE ORF1300 SERIES & DRT SERIES MODEL CODE

KN Visual, 15 PSI, No connector PLV 1B V N N Visual, 15 PSI, No connector SLV 1B V N N


MH Electrical, 15 PSI, Hirschmann PLE 1B V H N Electrical, 15 PSI, Hirschmann SLE 1B V H N
MB Electrical, 15 PSI, Brad Harrison PLE 1B V B N Electrical, 15 PSI, Brad Harrison SLE 1B V B N
MJ Electrical, 15 PSI, Hirschmann w 24 Volt light PLE 1B V H L24 Electrical, 15 PSI, Hirschmann w 24 Volt light SLE 1B V H L24
MK Electrical, 15 PSI, Hirschmann w 115 Volt light PLE 1B V H L115 Electrical, 15 PSI, Hirschmann w 115 Volt light SLE 1B V H L115
ML Electrical, 15 PSI, Hirschmann w 230 Volt light PLE 1B V H L230 Electrical, 15 PSI, Hirschmann w 230 Volt light SLE 1B V H L230
LN Visual, 30 PSI, No connector PLV 2B V N N Visual, 30 PSI, No connector SLV 2B V N N
RH Visual, 30 PSI, Hirschmann PLE 2B V H N Visual, 30 PSI, Hirschmann SLE 2B V H N
RB Electrical, 30 PSI, Brad Harrison PLE 2B V B N Electrical, 30 PSI, Brad Harrison SLE 2B V B N
RJ Electrical, 30 PSI, Hirschmann w 24 Volt light PLE 2B V H L24 Electrical, 30 PSI, Hirschmann w 24 Volt light SLE 2B V H L24
RK Electrical, 30 PSI, Hirschmann w 115 Volt light PLE 2B V H L115 Electrical, 30 PSI, Hirschmann w 115 Volt light SLE 2B V H L115
RL Electrical, 30 PSI, Hirschmann w 230 Volt light PLE 2B V H L230 Electrical, 30 PSI, Hirschmann w 230 Volt light SLE 2B V H L230
AN Visual, 70 PSI, No connector PLV 5B V N N Visual, 70 PSI, No connector SLV 5B V N N
UH Electrical, 70 PSI, Hirschmann PLE 5B V H N Electrical, 70 PSI, Hirschmann SLE 5B V H N
UB Electrical, 70 PSI, Brad Harrison PLE 5B V B N Electrical, 70 PSI, Brad Harrison SLE 5B V B N
UJ Electrical, 70 PSI, Hirschmann w 24 Volt light PLE 5B V H L24 Electrical, 70 PSI, Hirschmann w 24 Volt light SLE 5B V H L24
UK Electrical, 70 PSI, Hirschmann w 115 Volt light PLE 5B V H L115 Electrical, 70 PSI, Hirschmann w 115 Volt light SLE 5B V H L115
UL Electrical, 70 PSI, Hirschmann w 230 Volt light PLE 5B V H L230 Electrical, 70 PSI, Hirschmann w 230 Volt light SLE 5B V H L230

50 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 149
Accessories

Electrical Pressure Switch Hirschmann Connector

77
(3.03)

75
(2.95)
105.8
(4.16)

30 1/8 BSP
(1.18)

HOUSING PART NUMBER

DRT 3039708 Electrical Switch 30 psi Hirschmann Connector

Gauge 0-10 Bar Gauge

3
2
0 10
bar

ø50

30.5
(1.20) 46.7
(1.84)

1/8" BSP
13.97
(0.55)

HOUSING PART NUMBER

DRT 3039703 Gauge 0 - 10 Bar


Note: Gauges indicate pressure in both bar and psi

150 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December EATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 51
Accessories
Indicator Switch

electrical pressure switch

Schematic Wiring Diagram Hirschmann (DIN 43650 Type AM) Receptacle


GD
Note: The female connector is to be 1 2
furnished by the customer. WHITE 3

Note: When fitting indicator, torque BLACK


to 41-47 Nm. PIN
ARRANGEMENT
ELECTRICAL

Switch: SPDT NO
GD GREEN
Rating: 7 amps, resistive C
4 amps, inductive 1 2
TO
2 amps, lamp load NC RED 3 SYSTEM
@28 VDC, 115 VAC 60 Hz
& 220 VAC 50 Hz or 60 Hz

Brad Harrison (41512) Receptacle


GD
1 5
WHITE
2 4
BLACK
3

PIN
ORANGE

ARRANGEMENT
NO 1 5
TO
C
SYSTEM
2 4
NC RED
3 GREEN

Electrical Pressure Switch


HOUSING PART NUMBER

HF4RT 3039705 Electrical Switch 15 psi Brad Harrison Connector


3039707 Electrical Switch 15 psi Hirshmann Connector
HF4RT 3039706 Electrical Switch 30 psi Brad Harrison Connector
3039708 Electrical Switch 30 psi Hirshmann Connector

Hirshmann Connector Brad Harrison Connector

70
77 (2.76)
(3.03)

75 75
(2.95) (2.95)
105.8 105.8
(4.16) (4.16)

30 1/8 NPT
(1.18) 30 1/8 NPT
(1.18)

52 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 151
Accessories
Gauge

HOUSING PART NUMBER 0-4 Bar (0-60 PSI) Gauge 0-10 Bar (0-160 PSI) Gauge
HF4RT 3039703 Gauge 0-160 psi (use with 43 psi Bypass Valve)
3039704 Gauge 0-60 psi (use with 25 psi Bypass Valve)
25
Note: Gauges indicate pressure in both bar and psi 20 3
2
0 PSI60 0 10
bar

ø50 ø50

30.5 30.5
(1.20) (1.20)
46.7 46.7
(1.84) (1.84)

1/8" NPFT 1/8" NPFT


13.97 13.97
(0.55) (0.55)

Mounting Bracket 65 280


(11.0)
HV6R Housing (2.6)
15 140 126
(0.6) (5.5) (5.0)
mm (inch)
40 (1.6) 15
Order part number 3039702 (0.6) ø232
ø18 (9.1")
(0.7")

14
(0.6) 172
(6.8)
280
(11)

ø290
(11.4")

152 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022


EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 53
Accessories
Gauge

Seal Kits SERIES SEAL SEAL KIT


TYPE PART #

Note HV6R Buna-N 3039688


Seal kits include all soft Viton-A* 3039689
goods to fully service a unit.
HV3R Buna-N 3039690
Weld Flange for HF4RT Viton-A 3039691
HF4RT Buna-N 3039692
Order part number P-232964-1 Viton-A 3039693
HF2P Buna-N 3039694
Viton-A 3039695
D DIMENSIONS
HF3P Buna-N 3039696
A Housing A B C D E
Viton-A 3039697
ø diameter length
C HF3PS Buna-N 3039698
HL 15, HL 16 Viton-A
7/16 - 20 UNF 127,0
3039699 181,0 7/16 - 20 UNF x 0.75 12,7
B P-232964-01 thru (4) on 6.25 dia. (5.00) (7.12) Recommended bolts (0.50)
HF4P Buna-N
BC equally spaced 3039700
Viton-A 3039701
E OFR60/ Buna-N 590021
120 Viton-A 591761
(Bowl seal only)
OFR15/ Buna-N 226214
30 Viton-A 262422
(Bowl seal only)

* Viton is a registered trademark of E.I. Dupont

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 153

Seal Kits SERIES SEAL SEAL KIT


TYPE PART #

Note HV6R Buna-N 3039688


Seal kits include all soft Viton-A* 3039689
goods to fully service a unit. HV3R Buna-N 3039690
Viton-A 3039691
HF4RT Buna-N 3039692
Viton-A 3039693
HF2P Buna-N 3039694
Viton-A 3039695
HF3P Buna-N 3039696
Viton-A 3039697
HF3PS Buna-N 3039698
Viton-A 3039699
HF4P Buna-N 3039700
Viton-A 3039701
OFR60/ Buna-N 590021
120 Viton-A 591761
(Bowl seal only)
OFR15/ Buna-N 226214
30 Viton-A 262422
(Bowl seal only)

* Viton is a registered trademark of E.I. Dupont

54 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 FebruaryEATON


2022 Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 153
Notes

154 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December EATON


2007 Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 55
North America Greater China For more information, please US
44 Apple Street No. 7, Lane 280, email us at filtration@eaton.com 1 A 7.3.3
Tinton Falls, NJ 07724 Linhong Road 02-2022
Toll Free: 800 656-3344 Changning District, 200335 or visit www.eaton.com/filtration
(North America only) Shanghai, P.R. China
© 2022 Eaton. All rights reserved. All trademarks
Tel: +1 732 212-4700 Tel: +86 21 5200-0099 and registered trademarks are the property of their
respective owners. All information and recommenda-
tions appearing in this brochure concerning the use of
Europe/Africa/Middle East Asia-Pacific products described herein are based on tests believed
Auf der Heide 2 100G Pasir Panjang Road to be reliable. However, it is the user’s responsibility
53947 Nettersheim, Germany #07-08 Interlocal Centre to determine the suitability for his own use of such
Tel: +49 2486 809-0 Singapore 118523 products. Since the actual use by others is beyond our
Tel: +65 6825-1668 control, no guarantee, expressed or implied, is made
Friedensstraße 41 by Eaton as to the effects of such use or the results
68804 Altlußheim, Germany to be obtained. Eaton assumes no liability arising out
Tel: +49 6205 2094-0 of the use by others of such products. Nor is the infor-
mation herein to be construed as absolutely complete,
An den Nahewiesen 24 since additional information may be necessary or
55450 Langenlonsheim, Germany desirable when particular or exceptional conditions or
Tel: +49 6704 204-0 circumstances exist or because of applicable laws or
government regulations.

You might also like