Eaton VICKERS Filtration Master Catalog
Eaton VICKERS Filtration Master Catalog
Vickers
Filtration Master
Catalogue
LV2P Series
LV2P Series Pressure
Pressure 110
110
MODELPAGE MODELPAGE
Flows to:
Flows to: 110
110 L/min
L/min (29
(29 USgpm)
USgpm)
Fluid Analysis
Eaton Fluid Analysis Service
Pressures to:
Pressures to: 100
100 bar
bar (1,500
(1,500 psi)
psi)
Elements: V051...series
V051...series
Critical Analysis Clear Benefits
Eaton hydraulic components have a global reputation
for quality, reliability and performance. That reputation
is built on a tradition of customer service and we
Fluid is the lifeblood of every
hydraulic power system. To
keep yours running
We offer testing designed to
tell you the most about your
hydraulic fluid. We use Elements: 111
111
Fluid Analysis Pressure Filters
efficiently and effectively, sophisticated computer
stand behind every one of our products.
Breathers
Our Fluid Analysis Service follows that same tradition.
you need to know what’s in
it. What you don’t know can
programs and laboratory
diagnostic equipment such
hurt you. as an Energy Dispersive
We provide our customers with comprehensive fluid
The Eaton Fluid Analysis X-ray Fluorescence and an
testing and diagnostic services, with detailed reports inductively coupled plasma
that are easy to understand. Service analyzes hydraulic
spectrophotometer.
LV4PSeries
SeriesPressure
Pressure 113
fluid in much the same way
To find out how theH2O-gate™
Eaton Fluid
Analysis Service can help your
operation, read on.
Reservoir Breather
a medical lab tests a blood
Fluid Analysis
sample. Just as a blood test
helps a doctor diagnose
Features/Benefits:
health problems, a sample of
After we use this advanced
equipment to provide the
most• detailed
Media possible
contains oil
analysis of your hydraulic
Part Numbers:
9 ECF
LV4P Series Pressure 34
113
Flows to: 110 L/min (29 USgpm)
• Visual Mechanical attractant layerthat
to collect
Flows
Flows to:
to: 19
110L/min (5(29
USgpm)
Then call us to hydraulic fluid can help fluid, we create reports
L/min USgpm)
us pinpointActuates
sources of when and return
are always oil splashes.
easy to read and
H20-gate BR110
get started. Indicator:
contamination and determine understand. By taking the Bayonet Adapter 924710
particles have blocked the • Easyout Installation:
Elements: 114
failures, maintain optimum
A Name You Trust Reduces
componentdew point
performance, • Durable Plastic Housing:
Only one fluid analysis lab lets you put years of Eaton temperature
and identify anytosubstandard
prevent Protects the media from
experience to work for you. So when the health of condensation and is Your
maintenance practices. external splashing.
Breathers
your hydraulic system is at stake, choose a partner bottom-line
99.7% benefitinis blocking
efficient
with more than 75 years of experience. Contact your increased productivity. • Superior breather filters
Eaton representative for more information on our Fluid
particles 3µ and larger. both moisture and
Analysis Service. • Reversible Flow Through particles from air.
Media: Allows for
HF2P
HF2P Series In Line
Lineand
andSubplate
Subplate 36
• Effective up to 121°C
Flowsto:
to:90
90L/min
L/min(24(24USgpm)
USgpm)
12025 and offers a full range
Flows
viscosity, your equipment will we determine the insoluble Spectrometric Analysis
of tests specifically designed
Pressuresto: to:280
280bar
bar(4,000
(4,000psi)
psi)
inefficient particles and gel-like matter, soluble elements and
Pressures
Our laboratory equipment operation, premature system
Elements:V304...series
V304...series
hydraulic or oil lubricated • Visual • Durable Plastic Housing:
system, and our drawdown
particle isolation procedure
ensures accurate results.
drawdown patch helps us
Indicator:
identify theActuates
particles
source andwhen
have blocked the
of fluid contaminants.
media, before theCount
type
pump
to evaluate the condition
of the Protects
additives inthe
rather external
media from
a fluid
splashing.
than its particulate
contamination. Used in
Dirt-gate
Bayonet Adapter
Screw-in Adapter
BR210
924710
P-077002 Elements:
Elements: V304...series 117
37
117
Automatic Particle • High Efficiency:
Our testing procedures cavitates.
(ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle(99% at 2it helps
counting, microns)
us
• Easy Installation:
a photo sensor to count the accurately assess the
• Very Low Pressure Drop Note:
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter Lightweight
number and size design can
of particles
• Filters out particles This breather does not filter
BR210 Breather 13
patch using an optical be hand
in the fluidtightened
sample andonto
then Energy Dispersive X-ray
define contaminants
adapter. Fluorescence (ASTM E moisture from air.
MF2P Series
Series Pressure 119
Water (ASTM E203): We and quantities. Automatic (250°F)
Dispersive X-ray Fluorescence
process verifies the determine the water content
MF2P Pressure 39
automatic particle count to particle counting is quick, (XRF)
• analysis
Rated onupsamples
to 25 SCFM
Flows to:
to: 113.5
113.5 L/min
L/min (30
(30 USgpm)
USgpm)
us predict quality and provides reliable information concentrations of particulate
special preparation. This performance characteristics
Flows
provides confirmation of we can use to check against contamination. By isolating
for the fluid and system ISO Standard 4406, which chemical elements, we
automatic counter results, components. Excess water
Flows to:
Pressures 113.5
to: L/minbar
275.5 (30(4,000
bar USgpm)
(4,000 psi)
and helps us see what defines the relationship pinpoint contaminant types so
reduces the viscosity of between particle counts and we can establish their origins,
Elements: V051...series
Pressures V051...series
to: 275.5 bar (4,000 psi) 120
adverse chemical reactions what corrective actions,
Mobile-gate™ Filler Breather Assemblies
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Features/Benefits:
11
Part Number Elements: 120
• Proprietary Media: • Reversible Flow Through MBR110 5002486
Elements: V051...series 40
MBR110 and MBR120 Breathers 13
Reduces dew point Media: Allows for MBR120 5002487
temperature to prevent moisture to exit the
condensation and is reservoir.
99.7% efficient in
OFPH003/005 Series
Series Pressure
Pressure 122
• Easy Installation:
OFPH003/005 122
Lightweight design can be
and larger. hand tightened.
• Water Barrier: • Rugged metal housing is
applications
Regenerates its water
shedding capacity with
each cycle.
long lasting and ideal for
mobile applications. FlowsSeries
Flows
HF4P up to:
up to:In
53Line
53 L/min
L/min (14Subplate
(14
and USgpm)
USgpm) 42
MBR120
• Rated to 16.7 SCFM
Pressures to:
Pressures to: 310
310 bar
bar (4,500
(4,500 psi)
psi)
Flows to: 570
Elements: L/min (150
OFPH31 USgpm)
== V0603
V0603 123
MBR110
Check out our full line of filtration products and accessories at www.eaton.com/filtration
Fluid Analysis
The systemic contamination Once the targetEaton
has been There are four primary
Fluid Analysis Service Critic
control approach assures set, the next step is to sources for solid
Eatonfilters
hydraulic components have a global reputation Fluid
the user of the hydraulic select and position contamination to enter hydra
for quality, reliability and performance. That reputation
system a cost effective in the system so that the a hydraulic fluid.
is built on a tradition of customer service and we keep
approach to contamination target can be achieved
stand behindin every oneThey are:products.
of our contaminated new
efficie
you n
control that allows the price a cost effective manner. oil, built-in contamination, it. Wh
Our Fluid Analysis Service follows that same tradition.
of the filters and elements After the machine ingressed
is in our customers
We provide contaminationfluid
with comprehensive hurt y
to be quickly recovered by operation, the last and
testing and
and diagnostic internally-generated
services, with detailed reports The E
the savings of improved ongoing step isthat
to are easy to understand.
confirm contamination.
Servic
fluid i
performance, increased that the target To
cleanliness a med
find out how the Eaton Fluid
component life, increased oil level is being maintained.
Analysis Service can help your samp
life, increased uptime and operation, read on. helps
fewer repairs. This is most often health
Then call us to hydra
accomplished by sending
The goal of systemic a fluid sample toget started.
a particle
us pin
conta
contamination control is counting laboratory that wheth
always the same: to clean gives cleanliness code data uses
the fluid to the point that to established standards. If We c
contamination is not a factor the target is being met, the
catas
failure
in the failure (catastrophic, system only needsA Name You Trust
to have comp
intermittent, or degradation) Onlyand
one fluid Eaton Fluid Analysis Service PN 894276
For a hydraulic or oil filters maintained the analysis lab lets you put years of Eaton and id
of any component in the experience to work for you. So when the health of
fluid retested periodically. If
maint
lubricated machine, the your hydraulic system is at stake, choose a partner botto
system during the desired the cleanlinesswith
target
moreisthan
not75 years of experience. Contact your
development of a target increa
useful life of that system. being achieved,Eaton representative for more information on our Fluid
corrective
cleanliness level and the Analysis Service.
plan to achieve it is as much The first step towards this actions need to be taken.
a part of system design as goal is the setting of a target Sometimes a change in
cleanliness level that takes Comprehensive
maintenance practices is Testing Viscosity (ASTM D445): and d
the selection of the pump, We use this test to determine perfor
valves, actuators or bearings. into account the specific needed, but at Theother times
Eaton a
Fluid Analysis the viscosity of your oil.
Service is certified to ISO Draw
needs of the system. shift to a finer grade of filter
12025 and offers a full range
Without proper hydraulic fluid Isolat
elements or additional filter designed viscosity,
of tests specifically
your equipment will we de
Vickers Systemic Sources of Contamination housings may be needed.
for the analysis of hydraulic
suffer. Incorrect viscosity conta
leads to fluid breakdown, fluids
Approach to Eaton doc. 561, page 8 and lubrication system fluid. inefficient equipment partic
Our laboratory equipment
Contamination Control and test procedures provide
operation, premature system organ
Generated Ingressed from cylinder rod failure and damage to other Used
• Set a target Cleanliness an exact analysis of your
by cylinder hydraulic or oil lubricated
components. photo
Level system, and our drawdown drawd
particle isolation procedure identi
• Select filters and filter ensures accurate results. of flui
placements to achieve A B Autom
target Our testing procedures (ISO 1
Generated by valve can include: intens
• Sample fluid and confirm P T a pho
Photomicrography: We
achievement scan and photograph a filter numb
patch using an optical in the
Pressure microscope to find particle define
accord
line filter size and type. The scanning Water (ASTM E203): We and q
process verifies the determine the water content
automatic particle count to partic
in hydraulic fluid, which helps repea
identify samples needing us predict quality and
Transfer cart
special preparation. Thisfilter performance characteristics
provid
provides confirmation of we ca
for the fluid and system ISO S
automatic counter results, components. Excess water
and helps us see what define
reduces the viscosity of
Return contaminants are in the fluid. hydraulic fluid, which
betwe
line hydra
Ingressed from Generated increases the likelihood of This le
Ingressed filter adverse chemical reactions
air breather what
by pump through
M reservoir M EATON Vic
openings Ingressed
from
Built-in debris new oil
Contaminated New Oil be metal, silica and fibers. Ingressed Contamination Generated Contamination
Although hydraulic and With fluids from reputable Contamination from the The most dangerous
lubrication fluids are refined suppliers, sampling has immediate surroundings can contamination to a system is
and blended under relatively shown typical Cleanliness be ingressed into the fluid the contamination generated
clean conditions, the fluid Levels of 17/16/14 or dirtier. power or lubrication system. by the system itself. These
travels through many hoses Using a portable transfer cart On large installations, such as particles are “work
and pipes before it is stored fitted with a high efficiency those within steelworks or hardened” to a greater
in drums or in a bulk tank at filter, contamination should automotive plants, it is hardness than the surface
the user’s facility. At this be removed from new fluids relatively easy to know the from which they came, and
point, the fluid is no longer before the contamination environmental conditions, are very aggressive in
clean as the fluid lines it has enters and damages the though they vary considerably. causing further wear in the
traveled through have components in the system. For example, a coke oven system. In a system running
contributed metal and rubber system operates in conditions on properly cleaned fluid very
particles, and the drums Built-in Contamination very different from a similar few particles are generated,
have added flakes of metal New machinery always system in a cold mill. For although all components
or scale. Storage tanks are a contains a certain amount of mobile equipment, there is a (especially pumps) create a
real problem because water built-in contamination. Care very wide variation in small amount of particles
condenses in them causing in system assembly and in environmental conditions by during routine operation. In a
rust particles. Contamination new component flushing application, location and even system where these particles
from the atmosphere can reduces this but never by weather conditions (i.e. are not quickly captured the
eliminates it. Typical built-in high winds). elevated contamination levels
The key is to severely limit will cause the number of
the access that environmental additional generated particles
contamination has to enter to increase at a highly
the hydraulic or lubrication accelerated rate! The best
system. There are four major way to prevent
ways dirt can enter a system: contamination generation
reservoir vent ports (breathers), within a system is to start
power unit or system access with a clean (fully flushed)
plates, components left open system and keep the system
during maintenance and fluid clean.
cylinder seals.
also find its way into the Eaton H20 Gate Reservoir Breather BR110
tank unless satisfactory air
breathers are fitted. contaminants are burrs,
If the fluid is stored under chips, flash, dirt, dust, fiber,
reasonable conditions, the sand, moisture, pipe sealant,
principal contaminants on weld splatter, paint and
delivery to the machine will flushing solution.
Filter Element Initial Beta ratios and dirt capacity. Eaton Media Construction
Efficiency The most important Coated Steel Mesh
Performance Beta Test (ISO expect when that filter and Non woven synthetic diffuser
16889). The results of this media are properly installed (drainage) layer
indicators are designed to In poorly supported elements, changes in flow and pressure drop cause the
indicate at a pressure drop sides of element corrugations to flex and the root to stretch, giving rise to fatigue
20% below the bypass stresses. Dirt capacity is also lost as areas of the medium have no flow.
setting which equates to Eaton doc. 561, page 21
95% of the element’s
service life. This indication
before bypass feature was No flow Flow directions
incorporated to allow safe
operation of the machine Deflection under Filter medium
until the next shift change or high flow
convenient maintenance
opportunity.
Target Cleanlines that maintenance of the Housing for longer element life.
Using the Vickers Target system will be consistent The selected housing should Some systems require
Cleanliness Worksheet with current technology. be rated within the required filtration with no bypass,
(#578), it is easy to If in operation the system is flow and pressures of the such as servo applications.
determine the target ISO running dirtier than expected, application. Vickers H-Pak media is
Cleanliness Level for a corrective actions should be Important: If the system recommended for non-
system. This target is based initiated. Suggested corrective fluid’s specific gravity (SG) is bypass systems.
on the application’s actions are: greater than 0.9 (for
components and system • Check the indicator to example, water glycol), the Indicator
dynamics. see if the filters are on housing pressure drop (∆P) To meet ANSI Standard
by-pass. should be corrected for 12.2.5, filter assemblies
Placement and Media actual application. should have a device to
• Check the sources of
Use the chart below to help ingression and correct indicate when the filter
select the appropriate filter problems. Specific Gravity requires servicing. Per ANSI
placement and grade of Corrections for Pressure Standard 12.2.6, the
media to acheive the target • Check that the filters are Drops indicator should “trip” at
cleanliness level. For more positioned properly to see approximately 80% of the
maximum fluid flow. The filter housing flow
detail, consult the Eaton curves in this catalog can be bypass pressure setting. If
Guide to Systemic • Consider using a finer adjusted using the following using a non-bypass housing,
Contaminaton Control, Pak grade equation: an indicator selling of
your Vickers representative, approximately 100 psid is
• Add additional filters to Adjusted ∆PHousing =
or the ANSI System recommended. Differential
the system. ∆PCurve x Actual SG ÷ 0.9
Standards for Stationary pressure indicators are rated
Industrial Machinery. 6,000 psi working, 3,500 psi
Note: All systems need a Bypass Valve fatigue.∆
Filter Placement sealed reservoir with vent Bypass valve selection is
The chart below helps port filtration. based upon system
engineers select the grade requirements. According to
of Vickers media and the CAUTION ANSI Standard 12.2.6, filter
filter placement(s) that will assemblies whose elements
Before servicing the
acheive the required target cannot withstand full system
element, the bleed
cleanliness. It assumes the differential pressure without
plug in filter housing
system will experience damage should be equipped
must be loosened to relieve
“average” ingression and with bypass valves.
pressure. This will minimize
Generally, a higher bypass
fluid overflow.
pressure setting will allow
Full flow pressure Full flow pressure Pressure line/ Pressure line plus Recirculating loop at Recirculating loop at
line or return line line or return line recirculating loop at return line plus 20% of system volume 10% of system volume
20% of system volume recirculating loop per minute per minute
per minute
14/12/10 - 03 03 03 - -
15/13/11 - 03 03 05 - -
16/14/12 03 05 05 05 or 10 03 03
17/15/13 03 05 05 05 or 10 03 03
18/16/14 05 10 05 or 10 10 05 03
16/14/10 05 or 10 10 10 10 05 or 10 05
Comprehensive Testing Viscosity (ASTM D445): and degrades equipment if any, are needed. The lab
We use this test to determine performance. is also capable of testing to
The Eaton Fluid Analysis the viscosity of your oil. the new ISO 4406(1999)
Service is certified to ISO Drawdown Particle
Without proper hydraulic fluid Isolation: Using this test, standard (4µ, 6µ,14µ).
12025 and offers a full range viscosity, your equipment will
of tests specifically designed we determine the insoluble Spectrometric Analysis
suffer. Incorrect viscosity contaminates in hydraulic (ASTM D 5185): This shows
for the analysis of hydraulic leads to fluid breakdown,
and lubrication system fluid. fluids, both insoluble us the concentration of oil-
inefficient equipment particles and gel-like matter, soluble elements and
Our laboratory equipment operation, premature system
and test procedures provide organics and inorganics. indicates the additives and
failure and damage to other Used in conjunction with trace metal content in the
an exact analysis of your components.
hydraulic or oil lubricated photomicrography, the fluids. We use this technique
system, and our drawdown drawdown patch helps us to evaluate the condition
particle isolation procedure identify the source and type of the additives in a fluid
ensures accurate results. of fluid contaminants. rather than its particulate
Automatic Particle Count contamination. Used in
Our testing procedures (ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle counting, it helps us
a photo sensor to count the accurately assess the
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter number and size of particles
patch using an optical in the fluid sample and then Energy Dispersive X-ray
microscope to find particle define contaminants Fluorescence (ASTM E
size and type. The scanning according to size distribution 1508): We perform Energy
Water (ASTM E203): We and quantities. Automatic Dispersive X-ray Fluorescence
process verifies the determine the water content
automatic particle count to particle counting is quick, (XRF) analysis on samples
in hydraulic fluid, which helps repeatable and accurate. It with extremely high
identify samples needing us predict quality and
special preparation. This provides reliable information concentrations of particulate
performance characteristics we can use to check against contamination. By isolating
provides confirmation of for the fluid and system
automatic counter results, ISO Standard 4406, which chemical elements, we
components. Excess water defines the relationship pinpoint contaminant types so
and helps us see what reduces the viscosity of
contaminants are in the fluid. between particle counts and we can establish their origins,
hydraulic fluid, which hydraulic fluid cleanliness. and so you can take corrective
increases the likelihood of This lets us determine exactly action.
adverse chemical reactions what corrective actions,
2. Trend Information: We
evaluate data from your VISCOSITY
previous two samples On-target Re-sample
along with the results of Marginal Immediate action
your current sample. This
provides a trend analysis
of critical measurements, TEST 1 TEST 2 TEST 3
and shows changes in the Time Present Previous #1 Previous #2
fluid over time. Viscosity 45.0 (210) 45.5 (212) 45.8 (213)
@ 100˚F cSt (SUS)
pH (ASTM E 70)
represents the strength of Water 0.03% 0.03% 0.03%
% Weight
Vacuum Pump PN 894279 acidity in hydraulic fluid,
and is usually measured pH 9.4 9.5 9.6
Note: pH is for water containing fluids only.
for water-containing
hydraulic fluids TAN mg KOH/gm 2.1 2.0 2.1
Note: TAN is for synthetic fluids only.
(water/glycols, invert
emulsions). Typical values
are 8.5–10.5. Particle Count Summary
Total Acid Number, or TEST 1 TEST 2 TEST 3
Time Present Previous #1 Previous #2
TAN (ASTM D 974), is the
amount of acid and acid- >2µ 65,120 4,100 418
acting material constituents >5µ 12,220 1,250 88
in hydraulic fluid. An >10µ 5,800 700 39
increase in TAN indicates >15µ 900 250 22
oxidation or acid >25µ 125 60 4
contamination. Some >50µ 12.0 5.0 1.0
hydraulic fluids exhibit
higher acid numbers than Cleanliness 23/21/17 19/17/15 16/14/12
Code
others. Typical values are
0.1–3.0.
KIT FEATURES
Photo Energy
Automatic Microscopy Dispersive Spectrographic
Particle Water Viscosity Drawdown XRF ASTM Analysis
Kit Count ASTM TAN/PH ASTM Particle E1508 ASTM
Part # ISO 11500 E203 (if applicable) D445 Isolation (if applicable) D5185
894276P • • • • • •
894277P • • • • • • •
Each kit includes:
• Super clean sample bottle
• Packaging for sending sample
• Numbered test sample data form
• Fluid analysis service
Also available is PN 894279, Vacuum Pump for extracting oil sample, and PN 932339, Ultra Clean Bottle.
Items not in bold are non-standard and may have a longer lead time
12
10 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Fluid Analysis Range Code
Cleanliness Code Graph
300,000
25 200,000
100,000 150,000
24 100.000
80,000
3. Cleanliness Code Graph: 23 50,000
This graph uses the ISO 40,000 40,000
22 30,000
4406 standard for 20,000 20,000
measuring and depicting 21 15,000
10,000 10,000
the amount and size of 20
particles per milliliter in 5,000 5,000
4,000
hydraulic fluid, shown in a 19 3,000
2,500 2,000
log-log2 graph that charts 18 1,500
the amount of particles 1,000 1,000
17
greater than certain micron 500
Hydraulic reservoirs “breathe” air in and out as the oil level rises and falls.
This circulating air contains particles and moisture that can cause
corrosion, increase equipment wear and reduce fluid performance. In
typical systems, the internal hydraulic fluid is warmer than the
external environment. This difference in temperatures causes
water vapor to form. Breathers protect your hydraulic
system by filtering out damaging moisture and particles.
More than 25% of the samples sent to the Eaton Fluid
Analysis Laboratory for analysis have significant water
contamination. In an operating system, the H20-gate
Vent Breather creates a moisture barrier when there
is a 5°F (2°C) difference between reservoir and
ambient temperature and when there is a 10%
per minute exchange of air volume above the
fluid. The Mobile-gate breather is smaller in
size but is also 1/4 the size and 1/2 the capacity
of the H20-gate. These temperature and air flow
conditions are present in most hydraulic systems
which employ a cylinder.
Part Numbers:
NPT Mobile-gate MBR110
Flange Mobile-gate MBR120
H20-gate BR110
Dirt-gate BR210
16
12 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Breathers
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration
EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 17
13
Breathers
105
(4.13)
184,2 12
(7.25) (.47)
12
(.47)
1.5 UN Straight Thread
.005
Inches of water
bar (psi)
bar (psi)
1.7 1.7
1.2 1.2
1.0 .0025 1.0 .0025
(.036) (.036)
0.7 0.7
0.2 0.2
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Air Flow, SCFM Air Flow, SCFM
Mobile-gate Specifications
PART NUMBER FLOW DIMENSIONS (in)
USgpm L/min D1 D2 D3 D4 H1 H2 T1
MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4
MBR120 125 475 3.08 1.88 - 2.50 3.50 -
MBR120 FLANGE - - - - 0.25 2.81 - - -
D1 D1
H1 H1 D3
D4
H2
H2 T1
D2
18
14 EATON Vickers Filtration
EATON Vickers Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Breathers
Adapters
Installation Dimensions
EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 19
15
Return Line Filters
General Data
Return line filters usually have spin-on type elements, Return line filters may also be equipped with fluid
cartridge elements in an in-line mounted housing, or sampling devices to monitor the fluid cleanliness
cartridge elements within a housing that is mounted level. Secondary ports may also be incorporated to
directly within the reservoir itself (sometimes referred add make-up fluid and ensure that the fluid is
to as an in-tank filter). transferred through a filter before entering the system.
Applications
• Stroke boom delimbers
• Drilling platforms
• Die cast machines/
injection molding
• Large machine tools
Items not in bold are non-standard and may have a longer lead time
20
16 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series
• Beta Ratio: βx(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 240 L/min (63 USgpm)
Length 4 280 L/min (74 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -30°C to 121°C (-22°F to 250°F)
• Visual and electrical Pressure rating: Operating 50 bar (725 psi)
indicators with lamp Fatigue 50 bar (725 psi)
options for system design Material: Head Aluminum
flexibility Bowl Carbon Steel
• Fully serviceable without Collar Carbon Steel
tools Dry weight: Length 1 2,3 kg (5.1 lbs)
• Zero leak by-pass valve (Approximate) Length 2 2,5 kg (5.5 lbs)
Length 4 3,4 kg (7.5 lbs)
construction
• Wide range of element
lengths for maximum
design flexibility
• High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HV3R * ** * ** * * * **
• High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HV3R Series 1 Filter Series - HV3R QH - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann Hirschmann
Model Code 2 Element Collapse Rating
LN - Visual (30 psi)
No Connector 6 Seal Material
1 - 17 bar (250 psi) Low Collapse RB - Electrical 2 bar (30 psi) B - Buna-N
Sample model code: 4 - 207 bar (3000 psi) High Brad Harrison V - Viton-A
Collapse RJ - Electrical 2 bar (30 psi)
HV3R1SC4RLB2C05 Viton is a registered trademark of E.I. DuPont
Hirschmann w 24 volt
3 Port Options light 7 Assembly Length
BC - G 1-1/4 to ISO 228 RK - Electrical 2 bar (30 psi) mm (inch)
SC - 1.625 - 12UN SAE-20 str. Hirschmann w 115 volt 1 - 207 (8.15)
Thd. (1-1/4" tube) light 2 - 266 (10.47)
RL - Electrical 2 bar (30 psi) 4 - 447 (17.6)
4 Valve Options Hirschmann w 230 volt
1- Non-Bypass light 8 Element Construction
3- Bypass set at 1.7 bar (25 psi) RH - Electrical 2 bar (30 psi) C - 17 bar (250 psi) Low Collapse
4- Bypass set at 3 bar (43 psi) Hirschmann H - 207 bar (3000 psi) High
6- Bypass set at 6 bar (87 psi) AN - Visual (70 psi) Collapse
No Connector X - no element
5 Indicator Options UB - Electrical 4.9 bar (70 psi)
JN - No Indicator (plug), Brad Harrison 9 Fluid Cleanliness Rating
No Connector UJ - Electrical 4.9 bar (70 psi) Target fluid
QB - Electrical 1 bar (15 psi) Hirschmann w 24 volt Code cleanliness level
Brad Harrison light *03 16/14/12 or better
QJ - Electrical 1 bar (15 psi) UK - Electrical 4.9 bar (70 psi) *05 18/16/14 or better
Hirschmann w 24V light Hirschmann w 115 volt
light *10 20/18/15 or better
QK - Electrical 1 bar (15 psi)
Hirschmann w 115V light UL - Electrical 4.9 bar (70 psi) *20 22/19/16 or better
QL - Electrical 1 bar (15 psi) Hirshman w 230 volt light XX no element
Hirschmann w 230V light
EATON
EATON Vickers
Vickers Filtration Catalog E-FIFI-MC002-E2
Filtration Catalog E-FIFI-MC002-E2December 2007
February 2022 21
17
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series
V3R * * * **
1 2 3 4 5
56
(2.2)
ø130
7.4 (5.12) Indicator Plug
(0.29)
Label
46.4
(1.83)
1 5/8-12UNF in. or G 1 1/4 port
SAE-20 port
2 PL'S
Refer to
Model Code
ø82.5
(3.25)
50.0 (1.97) ø125
Clearance for (4.92)
Element Removal
Items not in bold are non-standard and may have a longer lead time
22
18 EATON
EATON Vickers Filtration Catalog
Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December 2007
February 2022
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
Flow versus pressure drop:
HV3R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data
4,0 58
1,0
0,8 12 3,0
0,6 2,0 29
0,4 6
1,0
0,2
0
0 50 100 150 200 250 300 0 50 100 150 200
Flow Rate - L/min Flow Rate - L/min
Sample ∆P Calculation : HV3R1SC4RLB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.7x 0.8/0.9 + 100 x 0.006 x 46/32 x 0.8/0.9
= 0.620 + 0.76
= 1.38 bar
EATON
EATON Vickers Filtration Catalog
Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022 23
19
In-tank Filters
General Data
In-tank filters are a special type of low pressure return The filter housing may be equipped with diffusers
line filters. In-tank filters are mounted directly to the to ensure that the returning oil energy is gradually
reservoir tank top and have an accessible head that is dissipated within the reservoir fluid to minimize
located outside of the reservoir while the body of the the potential for aerating or foaming of the oil. In
housing is located inside the reservoir. The exposed addition, the diffuser helps direct the fluid outward
cover allows the element to be easily replaced as against the walls of the reservoir to aid in the heat
needed. transfer capability of the reservoir.
Applications
• Forestry harvesting
equipment such as
delimbers and feller
bunchers
• Injection molding or blow
molding equipment
• Offshore drilling platform
power units
• Machine tools
• Die cast machines
Items not in bold are non-standard and may have a longer lead time
44
20 EATON Vickers
EATON Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2 December 2007
February 2022
In-tank Filters Flows to 454 L/min (120 USgpm)
Pressures to 7 bar (100 psi)
HF4RT Series
Pop-rivets for
shipping purposes
only. Remove prior
to installation.
• Beta Ratio: βx(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 454 L/min (120 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards. Temp range: -30°C to 121°C (-22°F to 250°F)
• Conforms to HF4 Pressure rating: Operating 7 bar (100 psi)
specifications Fatigue 7 bar (100 psi)
• Gauge and electrical Material: Head Aluminum
switch options available to Cover Aluminum
monitor element loading Bowl Carbon Steel
Dry weight: Length 3 4,5 kg. (10.0 lbs.)
• In-tank configuration (Approximate) Length 6 6,6 kg. (14.5 lbs.)
minimizes space Length 7 8,4 kg. (18.6 lbs.)
requirements and potential
system leakage points
• Optional secondary
port allows filtration of a
second return line without
additional fittings or
filtered fill port
• High efficiency
replacement elements in
standard configurations (C-
Pak) to meet Target
Cleanliness Levels. HF4RT 1 ** * ** * ** * * **
Optional extend tube
allows smaller filtration unit
1 2 3 4 5 6 7 8 9 10
to be used where needed
HF4RT Series 1 Filter Series - HF4RT 5 Indicator Options* SZ - 2.50 - 12 UN SAE-32 str.
Filter and Element Thd. (2" tube) - use with
XX - No indicator
Model Code FE Inlet Port
2 Element Collapse Rating GA - Gauge 0-4 bar (0-60psi)
XX - No Secondary Port
1 - 10 bar (150 psi) Low GB - Gauge 0-10 bar (0-160psi) Note: No secondary port option is available
Sample model code: Collapse MB - Electrical, 15 PSI with the ME inlet port option.
Brad Harrison
HF4RT1SD313XXBC05 3 Port Options RB - Electrical, 30 PSI 8 Seal Material
BC - G11/4 to ISO 228 Brad Harrison
B - Buna-N
ME - 11/2" - SAE 4 bolt Flange MH - Electrical, 15 PSI V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
SD - 1.875 - 12 UN SAE-24 RH - Electrical, 30 PSI 9 Element Construction
str. Thd. (11/2" tube) Hirschmann
C - Standard Construction
FE - 11/2" - SAE 4 bolt Flange X - no element
Code 61 (UNC)
6 Assembly Length
mm (inch)
3 - 378 (14.9)
10 Fluid Cleanliness Rating
4 Valve Options Target fluid
6 - 584 (23)
3 - Bypass set at 1.7 bar 7 - 787 (31) Code cleanliness level
(25 psi)
cracking pressure 03 16/14/12 or better
7 Secondary Port
4 - Bypass set at 3 bar 05 18/16/14 or better
(43 psi) cracking BC - G11/4 to ISO 228 - use 10 20/18/15 or better
pressure with BC Inlet Port
SD - 1.875 - 12 UN SAE-24 20 22/19/16 or better
str. Thd. (11/2" tube) - XX no element
use with SD Inlet Port
* For indicator options, refer to Static Indicators on page 150.
EATON Vickers
EATON Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2022
2007 21
77
In-tank Filters Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
HF4RT Series
V405 1 * * C **
1 2 3 4 5 6
Housing Dimensions
mm (inch)
112.2
(4.42)
56.1 M10 or
(2.21) 3/8"-20 thread
4 PL'S
Equally
spaced
112.2
(4.42) ø127
(5.0")
ø158.75
(6.25)
Secondary 118.5
port
(4.67)
Indicator port
1/8 NPT 53.6
(2.11)
Refer to
Model Code
"ME" port - M12 x 1.75
"FE" port - 1/2 - 13UNC (4 places)
69.8
(2.75) 35.7
(1.41)
Outlet port
Length Connection
3 1" Hose ø38.1 (1.5)
Ø124.6 6 1 1/2" NPT SAE-4 bolt
flange code 61
(4.9) 7 1 1/2" NPT
Inlet Flange
0,6 3,5
3,0 3,0
0,4 6 25 PSI
2,5
2,0 2,0
0,2
1,5
0
0 100 200 300 400 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min
Sample ∆P Calculation : HF4RT1SD3XX3XXBC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.15 x 0.8/0.9 + 200 x 0.003 x 46/32 x 0.8/0.9
= 0.130 + 0.76
= 0.89 bar
EATONVickers
EATON Vickers Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022 23
79
Series
OF3Inlet Strainers
Series Inlet Strainers
Flows to 379Flows
L/min to
(100
379USgpm)
L/min (100 USgpm)
ries Inlet Strainers Flows to 379 L/min (100 USgpm)
OF3 Series Inlet Strainers Flows to 379 L/min (100 USgpm)
ures and Benefits
Features General Data
and Benefits General Data
Element Selection
Element Selection
less steel elements have 149 These Vickers inlet strainers protect The size and number of elements
The size and number of elements
and
on (100Benefits
mesh) Stainless
screen steel
micron (100
General
elements
to protect
mesh)
haveData
hydraulic
screen to
149
pumps
protect
These Vickers inlet Element
and control systems
strainersselected Selection
protect should be based on the
selected should be based on the
aulic pumps from solid hydraulic pumps and control systems
el elements have 149 pumpsThese
hydraulic from solid
from solid
Vickers inletcontaminants.
strainers They shouldThe sizemaximum and number flowofratings listed on this
elements
maximum flow ratings listed on this
aminants. fromprotect
solid contaminants. They page.should
The ratings are conservative, and
mesh) screen to protect
contaminants. hydraulic bepumps
used as andimmersion
control suction strainers
systems selected should be basedpage. on theThe ratings are conservative, and
be used as immersion suction strainers
a change in fluid viscosity
able from
mps
Features and Benefits
flow rates
solid to 379 L/min
Available flow oncontaminants.
fromtosolid
rates 379 pump inlet lines.
L/min General Data
They should maximum flow ratings listed on thisshould
a change in fluid
not
Element Selection
viscosity should not
on pump inlet lines. significantly affect capacity.
s.USgpm). Higher rates can be page. The ratings are conservative, significantlyand
affect capacity.
eved by using(100 USgpm).
multiple Higher
be used
strainers. rates can be Valve
as immersion
Bypass suction strainers
should not The size and number of elements
Stainless
L/min bysteel
w rates to 379achieved onelements
using multiple
pump inlet lines. 149 Bypass
have
strainers. These Valve a change
Vickers inlet in fluid viscosity
Cleaning
strainers protect
ssHigher
). valve available
rates canto
micron
Bypass be prevent
(100available
valve mesh) screen
Anprevent
to to protect
available integral relief valve
hydraulic significantly
pumps and affect
control capacity. Cleaning selected should be based on the
systems
em shutdown.
using multiple strainers. Bypass Valve An available integral relief valve The strainer elements should be
hydraulic
system pumps
shutdown. from solid
parallels the element and is preset to maximum
The strainer elements flow
should beratings listed on this
eent media to
available is contaminants.
pleated
prevent for longAn available
openintegral
at a 3 psi
parallels
pressure
from
the element
drop across Cleaning
solid contaminants.
and is cleaned They should
preset toperiodically. Remove the
Element media is pleated for long reliefopen valveatbe
a 3used asThe
psi pressureimmersion
drop across
elements suction cleaned
strainers
from should
the reservoir, washpage.
periodically. The
Remove ratings
the are conservative, and
down. the element. Element bypassing can be strainer elements be from
elements
Available flowparallels
life. tothe379
rates caused element
L/min andtheis preset
element.
on to Element
pump inletbypassing
lines. can bein a suitable
thoroughly solvent, athe
and
reservoir,
change in wash
fluid viscosity should not
ents
dia can be cleaned
is pleated for long and open at a 3 psi pressure by excessdrop flowacross
rates, high fluidcleaned periodically. Remove the in a suitable solvent, and
thoroughly
ed. (100
Elements USgpm). Higher
can be cleaned rates can
and
viscosity, becaused
dirt-loaded
by excess flow rates,
elements, or a elements
high fluid
blow
fromdry with
the air fromwash
reservoir, significantly affect capacity.
inside to outside.
blow dry with air from inside to outside.
reused. the element.
achieved by using multiple Element
caused combination
bypassing
strainers.viscosity,
of these. Bypass
can be
dirt-loaded Valve
elements, or a
thoroughly in a suitable solvent, and
n be cleaned and
Bypass valveviscosity,
available
by excess flow
to prevent
rates, high fluidof these.
combination
blow dry withrelief
air from inside to outside.
Cleaning
dirt-loaded elements, or Ana available integral valve
system shutdown. combination of these. parallels the element and is preset to The strainer elements should be
Element media is pleated for long open at a 3 psi pressure drop across cleaned periodically. Remove the
gn Specifications
life.
Design Model Code
Specifications the Code
Model element. Element bypassing can be elements from the reservoir, wash
caused by excess flow rates, high fluid thoroughly in a suitable solvent, and
Elements can be cleaned and
pecifications
ow:
8 reused.
Rated flow:
38 L/min
Model Code
(10 USgpm)
viscosity, dirt-loaded elements, or a blow dry with air from inside to outside.
OF3-08 38 L/min (10 USgpm) combination of these.
0 76 L/min (20 USgpm)
OF3-10 76 L/min (20 USgpm)
238 L/min114 (10 L/min
USgpm) (30 USgpm)
OF3-12 114 L/min (30 USgpm)
676 L/min189 (20 L/min
USgpm) (50 USgpm) 1 2 3 4
OF3-16 189 L/min (50 USgpm) 1 2 3 4
0114 L/min 284 L/min (75 USgpm)
(30 USgpm) 284 L/min (75 USgpm)
OF3-20
4189 L/min 379 L/min (100 USgpm)
(50 USgpm) 379 L/min (100 USgpm)
OF3-24
Design Specifications Model Code
1 2 3 4
284 L/min (75 USgpm)
mpatibility: 1 Model Series 3 Bypass Valve
Fluid compatibility: 1 Model Series 3 Bypass Valve
e379 L/min are
strainers (100compatible
USgpm) with
These strainers are compatible OF3 - Inlet
withstrainers 3RV - 3 psi differential opening pressure
mmonly
ty: used
Rated hydraulic fluids,
flow: used 1 Model Series OF3 - Inlet strainers 3 Bypass Valve 3RV - 3 psi differential opening pressure
all commonly hydraulic fluids, Blank - Omit if not required
dingare
ers phosphate
OF3-08
compatible esters
with and water
38 L/min (10 USgpm) Blank - Omit if not required
including phosphate OF3 esters
- Inlet and water
strainers 3RV - 3 psi differential opening pressure
dused
fluids.
hydraulic fluids, PortUSgpm)
Size (NPTF)
OF3-10
based fluids. 76 L/min 2 (20
2 Port Size (NPTF) Blank - Omit if not required
sphate
nge: esters Cand
-40OF3-12 waterC 114 L/min
to +107 4 Design number
Temp range: -40 C to +107 08 - (30
1” USgpm)
C 4 Design number
(-40 F to +225 F) 2 Port10 Size (NPTF)
1/ USgpm) 08 - 1”
OF3-16 189
(-40 L/min
F to +225 - (50
1
F) 4” 1
10 - 1 /4”
Subject to change. 1 Dimensions
Subject 2to change.
remain
3 4
Dimensions remain
n:-40 C toUnit
+107 C
is supplied with08 12 - 1 1/ ” 4 Design
the number
same for designs 10 through 19.
OF3-20
Filtration: 284
Unit is L/min
- supplied
1” (75
with2USgpm) 1
12 - 1 /2” the same for designs 10 through 19.
(-40 F to149+225micron
F) (100 mesh) 16 - 2”
OF3-24
wire cloth element. 149379
10 1
- L/min ” (100
1 /4(100
micron mesh)USgpm) 16 - 2” Subject to change. Dimensions remain
/20
- 11element.
12cloth - 21/2” the same for designs 10 through 19.
Unit is supplied with wire 2” 20 - 21/12”
:149 micronFluid(100 compatibility:
mesh) 16 - 2” 24 - 3” Model Series 3 Bypass Valve
Material: 24 - 3”
Nylon
wire cloth These
element. strainers20 -are2 1compatible
/ ” with
nt Head stainlessNylon
Pleated steel
2 OF3 - Inlet strainers 3RV - 3 psi differential opening pressure
all commonly
Element used
24
Pleated- 3” hydraulic
stainless fluids,
steel
ght: (Approximate)
Blank - Omit if not required
Nylon Dryincluding phosphate esters and water
weight: (Approximate)
8Pleated 0,3 kg
stainless(0.7 lbs)
steel
based fluids.
OF3-08 0,3 kg (0.7 lbs) 2 Port Size (NPTF)
0
proximate) 0,4 kg (1.0 lbs)
OF3-10 0,4 kg (1.0 lbs) 4 Design number
20,3 kg (0.7Temp
0,6 range:
kg (1.4
lbs) lbs) -40 C to +107 C 08 - 1”
OF3-12 0,6 kg (1.4 lbs)
60,4 kg (1.0
0,8 lbs)
kg (1.8 lbs)
OF3-16
(-40 F
0,8 kg (1.8 lbs)
to +225 F) 10 - 11/4” Subject to change. Dimensions remain
00,6 kg (1.4
1,0 lbs)
kg (2.3 lbs)
OF3-20
Filtration: 1,0Unit
kg (2.3
is lbs)
supplied with 12 - 1 1/ ” the same for designs 10 through 19.
40,8 kg (1.8
1,4 lbs)
kg (3.0 lbs) 2
OF3-24 1,4149
kg (3.0
micronlbs) (100 mesh) 16 - 2”
1,0 kg (2.3 lbs)
wire cloth element. 20 - 21/2”
1,4 kg (3.0 lbs)
Material: 24 - 3”
Head Nylon
Element Pleated stainless steel
Dry weight: (Approximate)
OF3-08 0,3 kg (0.7 lbs)
OF3-10 0,4 kg (1.0 lbs)
OF3-12 0,6 kg (1.4 lbs) 57
OF3-16 0,8 kg (1.8 lbs) 57
OF3-20 1,0 kg (2.3 lbs)
57
OF3-24 1,4 kg (3.0 lbs)
Inlet Strainer
Inlet
mm Strainer
(inch)
mm (inch)
C
A
Minimum Screen Area
Model Series cm2 (in2) A (NPTF pipe thread) B C 3,2 ( 0.125)
OF3-08 710 (110) 1” 67,8 (2.67) 135,9 (5.35)
OF3-10 1032 (160)
Minimum Screen Area 11/4” 88,1 (3.47) 174,0 (6.85)
Model Series
OF3-12 cm
2194 2 (in2)
(340) 11/2” A (NPTF pipe thread)
101,6 (4.00) B 250,2 (9.85) C 3,2 ( 0.125)
OF3-16
OF3-08 2194 (340)
710 (110) 2” 1” 101,6 (4.00) 67,8 (2.67)
250,2 (9.85) 135,9 (5.35)
OF3-20 2581 (400) 21/2” 131,3 (5.17) 256,5 (10.10)
OF3-10 1032 (160) 11/4” 88,1 (3.47) 174,0 (6.85)
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)
OF3-12 2194 (340) 11/2” 101,6 (4.00) 250,2 (9.85)
OF3-16 2194 (340) 2” 101,6 (4.00) 250,2 (9.85)
OF3-20 2581 (400) 21/2” 131,3 (5.17) 256,5 (10.10)
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)
Typical Installations
Pump intake
connection
Pump intake
Access opening should be provided so connection Pipe joints submerged
strainers can be removed for cleaning
without draining fluid from tank.
58
58
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 February 2022 25
Spin-on Filters
Spin-on Filters
General Data
Spin-on filters
General Datatypically consist of a head mounted
directly in-line with the return piping and a canister
Spin-on filters typically consist of a head mounted These are an effective and economical choice of filter
containing an element which screws onto a threaded
directly in-line with the return piping and a canister where the return line pressure is low and there are no
post. The canister seals to the head to prevent These are an effective and economical choice of filter
containing an element which screws onto a threaded large flow surges with the return line. They are also
leakage. where the return line pressure is low and there are no
post. The canister seals to the head to prevent easily installed without specialty equipment or tooling.
large flow surges with the return line. They are also
leakage.
Applications
easily installed without specialty equipment or tooling.
•Applications
Agricultural equipment -
tractors, spreaders,
• Agricultural
harvesters equipment -
tractors, spreaders,
• Metal forming presses
harvesters
•• Strapping systems
Metal forming presses
•• Strapping
Brush Chippers
systems
•• Turf
Brush Chippers equipment
maintenance
•• Small power unitsequipment
Turf maintenance
• Small power units
OFRS 15 * * *** * * * ** 10
1 2 3 4 5 6 7 8 9 10
OFRS15 Series 1 Filter Series - OFRS 5 Fluid Cleanliness Rating 8 Outlet Gauge Port
Filter and Element Target fluid Location (1/8" NPT)
Model Code 2 Flow Rating Code cleanliness level E - Location E
15 -15 USgpm (57 L/min) R03 16/14/12 X - No Gauge
Sample model code: R05 18/16/14
3 Port Type R10 20/18/15
9 Bypass Valve
OFRS15S2R03PBE1010
B - G1 to ISO 228 XXX - no element 10 -Bypass valve set at
P - 1in NPT 0.6 bar (10 psi)
S - 1.312-12 UN SAE-16 25 - Bypass valve set at
straight thd.
6 Pressure Gauge Option 1.7 bar (25 psi)
P - Pressure gauge 0-8 bar
4 Assembly Length (0-120 psi);l p/n 736129 10 Design Number
mm (inch) C - Color Coded Pressure 10 - Standard Design
1 - 194,6 (7.7) Gauge (For use with 1.7
2 - 250,4 (9.9) bar (25 psi) bypass only);
X - no element p/n P-232965-01
X - No Gauge
7 Inlet Gauge Port Location
(1/8" NPT)
B - Location B
X - No Gauge
V019 1 B * R **
1 2 3 4 5 6
Housing Dimensions
26,9 26,9 .375-16 UNC-2B thd. 19,1 (0.75) min. full thd.
mm (inch) (1.06) (1.06) 2 holes for mounting Mounting screw torque
20-27 Nm (15-20 ft-lb)
B Pressure gauge 3,05R (0.12R) Typ.
connection
E Pressure gauge connection1/8" NPTF pipe thd.
2 locations (see Model Code)
47,8
(1.88) 27,2 (1.07)
13,5
(0.53)
23,9
(0.94) 11,2 9,53/9,78R (0.375/0.385R) Typ.
11,2
(0.44) 7,87R (0.44)
(0.31R)
98,8
Optional pressure gauge (3.89)
49,3 44,4
(1.94) (1.75) Hex. - both ends
24,4
Approx. (0.96)
55,9
(2.20)
Std.
Inlet Outlet (length 1)
port port 194,6
(7.66)
Long
(length 2)
250,4
(9.86)
Std.
(length 1)
170,2
(6.70)
Long
(length 2)
226,1
(8.9)
35 2,5 36
30
25 2,0
20
15 1,5 22
10
5 0,5
0
9.5 19 28 38 47 57 66 76 85 95
Flow Rate - L/min 50 100 150 200
Flow Rate - L/min
Sample ∆P Calculation : OFRS15S2R03PBE1010 - Filter assembly having '2' length spinon filter element with micron
rating code '03' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing ∆P from graph + Element ∆P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.4 x 0.8/0.9 + 0.08 x 46/32 x 0.8/0.9
= 0.350 + 0.1
= 0.45 bar
• Designed to comply with Rated flow: Length 1 227 L/min (60 USgpm)
ANSI specifications and Length 2 454 L/min(120 USgpm)
ISO cleanliness standards Fluid compatibility Compatible with most petroleum ol, water glycol,
oil-in-water and water-in-oil fluids
• Dual flow path design Temp range: -32°C to +107°C (-25°F to +225°F)
maximizes flow capability
Pressure rating: Operating 14 bar (200 psi)
and service life
Material: Head Aluminum
• Spin-on element make
servicing fast and easy Dry weight: Length 1 7.3 kg (16 lbs)
Length 2 8.6 kg (19 lbs)
• High efficiency
replacement elements in
standard configurations
(R-Pak) to meet Target
Cleanliness Levels
HS22 1 FE * * N B * * **
1 2 3 4 5 6 7 8 9 10
30
104 EATON Vickers Filtration
EATON Filtration Catalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007
Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series
V021 1 B * * **
1 2 3 4 5 6
60 165,5
146 (6.52)
(2.36) (5.75)
171,0
(6.73)
Mounting Holes
3/8"-16 - 4 Places
40,0
286 (1.57)
(11.26)
35,5 Refer to
(1.40) Model Code
128,3
(5.05)
0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min
50 PSID Valve 65
0,8 4,0
9 3,0 45 44
0,6
0,4 2,0 25 PSID Valve
0,2 3 1,0 15
Sample ∆P Calculation : HS221SD32NB2RO5 - Filter assembly having '2' length filter element with micron rating code
'05' at 250 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing ∆P from graph + Element ∆P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 0.37 x 46/32 x 0.8/0.9
= 0.260 + 0.47
= 0.73 bar
32
106 EATONVickers
EATON Vickers Filtration
Filtration Catalog
Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022
Pressure Filters
General Data
Pressure filters are used to protect downstream In some applications, pressure filters are used as
components from contamination levels beyond the isolation filters to protect specific components such
recommended cleanliness target. Because they are as proportional or servo valves. Typically these
typically sized for the output of the pump, pressure filters filters are non-bypass and employ elements that are
tend to be smaller than return line filters when cylinders capable of withstanding full system differential
are present. In systems using accumulators, pressure pressure without collapsing. While these filters are
filters must be sized according to the large effective flow sized to handle only a specific components' required
rates present during parts of the duty cycle. flow, the use of high collapse elements result in a
higher cost than elements used in housings with
bypass valves. Most isolation filters are direct-
mounted beneath the valve which can save space
as well as reduce plumbing costs.
Applications
• Paper Mills • Test and simulation
• Steel Mills equipment
• Injection molding • Entertainment stage
machines equipment
• Motion bases • Hydrostatic drives
• Sawmill equipment • Power generation
turbine control systems
• Flight simulators
ECF 1 SB 1 J 3 * V ***
1 2 3 4 5 6 7 8 9
34
108 EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007
Pressure Filters Flows to 19 L/min (5 USgpm)
Pressures to 207 bar (3,000 psi)
ECF Series
Housing Dimensions
mm (inch)
Ø48.9
(Ø1.929)
Spotface
35.5
(1.399) 1.5
HEX
1 5/16-12UN-2B IN.
SAE-16 PORT
19.05
Ø19.05 0.76 3.3 (0.75)
(Ø0.75) (0.03) (0.13)
Min. Full Thread
(3.157) (2.634)
20°
Ø25.3
(Ø.998)
OUTLET
1,25
Pressure drop-bar
Pressure drop-bar
1,25
16 16
1,00 1,00
0,75 12 12
0,75
0,50 8 8
0,50
0,25 4 0,25 4
0 0 0 0
0 4 8 12 16 20 24 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72
Flow Rate - L/min Flow Rate - L/min
EATON
EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007 35
109
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
• Beta Ratio: βx(c) = 1000 Rated flow: Length 1 45 L/min (12 USgpm)
to ISO 16889 Length 2 91 L/min (24 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual, electrical, and Pressure rating: Operating 280 bar (4000 psi)
electrical indicators with Fatigue 280 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Carbon Steel
• Conforms to HF2 Dry weight: Length 1 4,6 kg (10.1lbs)
(Approximate) Length 2 5,9 kg (134lbs)
automotive specifications
• Compact design for use with
servo and proportional valves
• Manifold mounting option
for system flexibility
• High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HF2P * ** * ** * * * **
• High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HF2P Series 1 Filter Series - HF2P RB - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Filter and Element Brad Harrison (70 psi), Hirschmann
RH - Electrical 2 bar (30 psi), w 115 volt light
Model Code 2 Element Collapse Rating Hirschmann UL - Electrical 4.9 bar (70 psi),
1 - 17 bar (250 psi) Low RJ - Electrical 2 bar (30 psi), Hirschmann w 230 volt
Sample model code: Collapse Hirschmann w 24 volt light
4 - 207 bar (3000 psi) High light
HF2P1SA4LNB2C05 Collapse RK - Electrical 2 bar (30 psi), 6 Seal Material
NOTE: Use 1 only with bypass valve or Hirschmann w 115 volt B - Buna-N
monitored P indicator. light V - Viton-A
RL - Electrical 2 bar (30 psi),
3 Port Options Hirschmann w 230 volt 7 Assembly Length
BA - G3/4 to ISO 228 light
SA - 1.062 - 12UN SAE-12 TB - Electrical 7.9 bar mm (inch)
(3/4" tube) (115 psi), Brad Harrison 1 - 211.9 (8.3)
WS - Subplate mounting TH - Electrical 7.9 bar 2 - 304.9 (12.0)
(115 psi), Hirschmann
4 Valve Options TJ - Electrical 7.9 bar 8 Element Construction
(115 psi), Hirschmann C - 17 bar (250 psi)
1 - Non-Bypass
w 24 volt light Low Collapse
4 - Bypass set at 2.9 bar TK - Electrical 7.9 bar
(43 psi) cracking pressure H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
6 - Bypass set at 6 bar w 115 volt light
(90 psi) cracking pressure X - no element
TL - Electrical 7.9 bar (115
psi), 9 Fluid Cleanliness Rating
5 Indicator Options Hirschmann w 230 volt
Target fluid
AN - Visual 4.9 bar (70 psi), light Code cleanliness level
No Connector UB - Electrical 4.9 bar
JN - No Indicator (plug), (70 psi), Brad Harrison 03 16/14/12 or better
No Connector UH - Electrical 4.9 bar 05 18/16/14 or better
LN - Visual 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
No Connector UJ - Electrical 4.9 bar
20 22/19/16 or better
ON - Visual 7.9 bar (115 psi), (70 psi), Hirschmann
w 24 volt light XX no element
No Connector
36
116 EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
V304 * * * * **
1 2 3 4 5 6
Housing Dimensions
mm (inch)
88.9
Subplate Mounting Outlet (3.50) Inlet Indicator Plug 21.4
7 44.5
(0.28) (1.75) (.08)
15.9
ø25.4 (0.63)
(1.00) 52 ø86
80 (2.05) (3.39)
(3.15)
ø17.5 31.8
(0.69) (1.25)
31.8 17 104
ø8.6 (0.34) thru (1.25) (0.67) (4.09)
4PL's
5/16-18UNC x 4.25 long
grade 8 bolts for 0.5
engagement are recommended
(4 req'd). Torque 9-12lb-ft (12-16Nm)
27 HEX 79.4
(1.06) (3.13)
7 24.2
(0.95) Inlet Outlet
(0.28)
ø6.75
(0.27)
96 98
(3.78) (3.86)
Refer to
Model Code
24 HEX
(0.95)
75 (2.96)
ø76.2 Clearance for
(3.00) Element Removal
EATON
EATON Vickers
Vickers Filtration
FiltrationCatalog
Catalog E-FIFI-MC002-E2 February 2022
E-FIFI-MC002-E2 December 2007 37
117
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.
Pressure drop-bar
0,8 272.5
15,0 222.5
172.5
0,4 6
10,0
122.5
0 5,0 72.5
0 20 40 60 80 100 0 10 20 30 40 50 60 70 80
Flow Rate - L/min Flow Rate - L/min
Sample ∆P Calculation : HF2P1SA4LNB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 50 x 0.016 x 46/32 x 0.8/0.9
= 0.220 + 1.01
= 1.23 bar
38
118 EATON Vickers Filtration
EATON Filtration Catalog E-FIFI-MC002-E2 December
Catalog E-FIFI-MC002-E2 February 2022
2007
Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series
• Beta Ratio: βx(c) = 1000 Rated flow: Length 5 68 L/min (18 USgpm)
to ISO 16889 Length 7 113.5 L/min (30 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual, electrical, and Pressure rating: Operating 276 bar (4000 psi)
electrical indicators with Fatigue 276 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Steel
• High efficiency Dry weight: Length 5 3,9 kg (8.3 lbs)
(Approximate) Length 7 4,5 kg (9.9 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
• Poppet type leak by-pass
valve construction
MF2P 1 SA 5 ** * * * **
1 2 3 4 5 6 7 8 9
V0512 * * C **
1 2 3 4 5
Housing Dimensions ø 41
92 (1.61)
mm (inch) 6
(3.62) Clogging
(0.24) Indicator
1 1/16-12 UN
Port
35 35
(1.38) (1.38)
90
(3.54)
Length 5
204
(8.03)
Length 7
257
(10.12)
SW 27
55 ø 76,2
(2.17) (3.00)
55 ø 86
(3.39)
OUTLET R9
INLET
ø 45 40
(1.37) (1.57)
mounting threads
3/8-16 UNC
40
120 EATONVickers
EATON Vickers Filtration
Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022
Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of < 0.9
Housing Bypass
Flow Rate - USgpm Flow Rate - USgpm
0 5 10 15 20 25 30 0 2 4 6 8 10 12 14
16 20,0
1,0 272.5
14
Sample ∆P Calculation : MF2P1SA5UNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 50 x 0.011 x 46/32 x 0.8/0.9
= 0.260 + 0.69
= 0.95 bar
EATONVickers
EATON Vickers Filtration
Filtration Catalog E-FIFI-MC002-E2
E-FIFI-MC002-E2December
February 2007
2022 41
121
Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series
• Beta Ratio: βx(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 568 L/min (150 USgpm)
• Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26°C to +121°C (-15°F to +250°F)
• Visual and electrical Pressure rating: Operating 345 bar (5000 psi)
indicators with lamp Fatigue 345 bar (5000 psi)
options for system Material: Head Ductile Iron
design flexibility Bowl Carbon Steel
• Conforms to HF4 Lid Ductile Iron
specifications Dry weight: Length 3 28,8 kg (63.4 lbs)
(Approximate) Length 6 38,7 kg (85.3 lbs)
• Fatigue rated to 5000 psi Length 7 51,5 kg (113.6 lbs)
for maximum reliability in
rugged applications
• Top loading design to
ease maintenance and
minimize spillage
• Multiple filter element HF4P * ** * ** * * * **
lengths for design flexibility
• High efficiency 1 2 3 4 5 6 7 8 9
replacement elements in JN - No Indicator (plug), UL - Electrical 4.9 bar (70 psi),
standard configurations
1 Filter Series - HF4P
No Connector Hirschmann w 230 volt
(C-Pak) to meet Target RB - Electrical 2 bar (30 psi), light
Cleanliness Levels
2 Element Collapse Rating
Brad Harrison UH - Electrical 4.9 bar
1 - 10 bar (150 psi) Low RJ - Electrical 2 bar (30 psi), (70 psi), Hirschmann
• High collapse elements
Collapse Hirschmann w 24 volt
available for non-bypass 4 - 207 bar (3000 psi)
applications light 6 Seal material
High Collapse RK - Electrical 2 bar (30 psi), B - Buna-N
Series Hirschmann w 115 volt V - Viton-A
3 Port options light
Filter and Element
BD - G11/2 to ISO 228 RL - Electrical 2 bar (30 psi), 7 Assembly Length
Model Code ME - 11/2" SAE 4 bolt Flange Hirschmann w 230 volt mm (inch)
Code 61 (M12 x 1.75) light 3 - 447 (17.6)
Sample model code: MR - 11/2" SAE 4 bolt Flange RH - Electrical 2 bar (30 psi), 6 - 685.3 (27)
HF4P1SD4LNB6C05 Code 62 (M16 x 2.0) Hirschmann 7 - 923.5 (36.4)
SD - 1.875 - 12 UN SAE-24 TB - Electrical 7.9 bar
str. Thd. (11/2" tube) (115 psi), Brad Harrison 8 Element construction
FE - 11/2" SAE 4 bolt Flange TJ - Electrical 7.9 bar
Code 61 (UNC) C - 10 bar (150 psi)
(115 psi), Hirschmann
FR - 11/2" SAE 4 bolt Flange Low Collapse
w/ 24 volt light
Code 62 (UNC) H - 207 bar (3000 psi)
TK - Electrical 7.9 bar High Collapse
WS - Subplate mounting (115 psi), Hirschmann
X - no element
w/ 115 volt light
4 Valve options TL - Electrical 7.9 bar 9 Fluid cleanliness rating
1 - Non-Bypass (115 psi), Hirschmann
Target fluid
4 - Bypass set at 2.9 bar w/ 230 volt light Code cleanliness level
(43 psi) cracking pressure TH - Electrical 7.9 bar
6 - Bypass set at 6 bar (115 psi), Hirschmann 03 16/14/12 or better
(90 psi) cracking pressure UB - Electrical 4.9 bar 05 18/16/14 or better
(70 psi), Brad Harrison 10 20/18/15 or better
5 Indicator options UJ - Electrical 4.9 bar 20* 22/19/16 or better
AN - Visual 4.9 bar (70 psi), (70 psi), Hirschmann XX no element
No Connector w 24 volt light
* C-Pak only
LN - Visual 2 bar (30 psi), UK - Electrical 4.9 bar
No Connector (70 psi), Hirschmann
w 115 volt light
1 2 3 4 5 6
V405 Element 1 Filter Element - V405 4 Element Length 6 Fluid Cleanliness Rating
model code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) 03 16/14/12
4 - 206.9 bar (3000 psi) 7 - 686 (27) 05 18/16/14
Sample model code:
High Collapse 10 20/18/15
V4051B3C03 NOTE: Use 1 only with bypass valve or 5 Element Construction
monitored delta P indicator. 20 22/19/16
C - C-Pak (code 03, 05, 10,
20)
3 Seals H - H-Pak (code 03, 05, 10)
B - Buna-N
V - Viton-A
Housing Dimensions Drain Plug
25.4 (1.00) 50.8
mm (inch) Hex 14.2 (2.00)
(0.56) 7.9 Outlet
thru (0.31)
57.2
158.8 4 PL'S (2.25)
(6.25)
79.4
(3.13) 114.3
(4.50)
Vent Plug
73 Inlet
(2.88) 146.1 Refer to
(5.75) Model Code Indicator
63.5 Port
(2.50)
127
(5.00)
133.4
22.4 (5.25) View X - Subplate Mounting
(0.88) 66.7
(2.63)
Refer to
Model
Code
70
(2.76)
35.1
Bolt Thread (1.38)
View X
E D C
A B C D E
mm mm mm mm mm
(inch) (inch) (inch) (inch) (inch)
B
A ME 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
MR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
FE 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
FR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
10,0 147
Pressure drop - psid
0,75
137
9,0
127
0,50 7
8,0 117
107
0,25 7,0
97
0 6,0 87
0 100 200 300 400
0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min
Sample ∆P Calculation : HF4P1SD4LNB6C05 - Filter assembly having '6' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.220 + 0.25
= 0.47 bar
1 2 3 4 5 6
1
/2-20UNF-2B in. X 17 (0.67)deep 4 Places
8.4 Indicator Plug
(0.33)
52 SAE-16, 24, G1 OR G1 1/2
(2.05)
16" Housing
Refer to
Model Code
117
(4.61)
ø152
(5.98)
427 Clearance required
Drain Plug G 1/2 ø130.2 (16.8) for element removal
95 (3.74) (5.13)
Clearance required for element removal
10,0 147
Pressure drop - psid
1,5
137
9,0
127
1,0 15
8,0 117
107
0,5 7,0
97
0 6,0 87
0 200 400 600 800 0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min
Sample ∆P Calculation : HF3P1SB4LNB2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
∆P Assembly = ∆P Housing + ∆P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.12 x 0.8/0.9 + 100 x 0.001 x 46/32 x 0.8/0.9
= 0.100 + 0.127
= 0.22 bar
** ** V * ***
1 2 3 4 5
INDICATOR OPTIONS (3000 PSI - USE WITH FILTER MODELS HV6R, HV3R)
Filter Assembly
Description Model Code Letters
POPUP VISUAL 15 psi PV 1B VN KN
POPUP VISUAL 30 psi PV 2B VN LN
POPUP VISUAL 70 psi PV 5B VN AN
BRAD HARRISON 5 PIN ELECTRICAL 15 psi PE 1B V B QB
BRAD HARRISON 5 PIN ELECTRICAL 30 psi PE 2B V B RB
BRAD HARRISON 5 PIN ELECTRICAL 70 psi PE 5B V B UB
HIRSCHMANN ELECTRICAL 15 psi PE 1B V H QH
HIRSCHMANN ELECTRICAL 30 psi PE 2B V H RH
HIRSCHMANN ELECTRICAL 70 psi PE 5B V H UH
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L24 PE 1B V H L24 QJ
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L24 PE 2B V H L24 RJ
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L24 PE 5B V H L24 UJ
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L115 PE 1B V H L115 QK
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L115 PE 2B V H L115 RK
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L115 PE 5B V H L115 UK
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L230 PE 1B V H L230 QL
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L230 PE 2B V H L230 RL
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L230 PE 5B V H L230 UL
PE * B V B PV * B VN
PHE * B V B
58 ø27
(2.28) (1.06)
A WHITE 1
3 RED
GREEN 2 27 HEX
P
1
2 ORANGE 34
BLACK 5
63.5 (1.06)
(2.50)
B
62.5 29
(2.46) 100.6 Schematic
(1.14)
(3.96)
G 1/2
27 G 1/2
(1.06)
PE * B V H PE * B V H L * *
PHE * B V H PHE * B V H L * *
70
(2.76)
51 A )
(2.00) 3
A ) 3P )
3 ) 1
3 1 )
P
2 )
1 1 )
) B
2
2 2
B )
60.2 111.4 Schematic
70
(2.76) 108.1 (2.37) (4.39)
(4.26) Schematic
27 G 1/2
27 G 1/2 (1.06)
(1.06)
PLV 2B V H L24
1 2 3 4 5
77
(3.03)
75
(2.95)
105.8
(4.16)
30 1/8 BSP
(1.18)
3
2
0 10
bar
ø50
30.5
(1.20) 46.7
(1.84)
1/8" BSP
13.97
(0.55)
Switch: SPDT NO
GD GREEN
Rating: 7 amps, resistive C
4 amps, inductive 1 2
TO
2 amps, lamp load NC RED 3 SYSTEM
@28 VDC, 115 VAC 60 Hz
& 220 VAC 50 Hz or 60 Hz
PIN
ORANGE
ARRANGEMENT
NO 1 5
TO
C
SYSTEM
2 4
NC RED
3 GREEN
70
77 (2.76)
(3.03)
75 75
(2.95) (2.95)
105.8 105.8
(4.16) (4.16)
30 1/8 NPT
(1.18) 30 1/8 NPT
(1.18)
HOUSING PART NUMBER 0-4 Bar (0-60 PSI) Gauge 0-10 Bar (0-160 PSI) Gauge
HF4RT 3039703 Gauge 0-160 psi (use with 43 psi Bypass Valve)
3039704 Gauge 0-60 psi (use with 25 psi Bypass Valve)
25
Note: Gauges indicate pressure in both bar and psi 20 3
2
0 PSI60 0 10
bar
ø50 ø50
30.5 30.5
(1.20) (1.20)
46.7 46.7
(1.84) (1.84)
14
(0.6) 172
(6.8)
280
(11)
ø290
(11.4")