18 FND-1796-TD-TB-XX-32-00: Maintenance 0
Total 37,100,680
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
A CONCEALED CONDUITING
Providing & fixing up of Point wiring (including circuit wiring with 3c x 2.5mmsq
PVC/PVC) with 3c x 1.5mmsq PVC/PVC 600/1000V grade copper cable installed
in PVC conduit rigid/flexible (clipped to the surface, or concealed in structure, or
underfloor) vertical drops to be in concealed PVC conduits or in already laid cable
1.0 trunking including all wiring accessories, ceiling rose, 10A switch, switch socket
outlet, solid state fan speed controller, sheet steel back boxes, localy
manufactured PVC junction boxes (100mm x 100mm x 75mm) with PVC glands
with phase and earth terminals, 1.0mmsq 3-core flexible PVC/PVC cord in flexible
PVC conduit upto fixture, etc for:
1.1 Light point, controlled by DB mounted pushbutton via MCB 8 Nos 3,130 25,037
1.3 Point Wiring Light point, from point to point 191 Nos 939 179,328
1.4 Insect killer point from DB with 5A round pin socket outlet 5 Nos 2,504 12,519
1.5 Insect killer point to point with 5A round pin socket outlet 9 Nos 1,878 16,900
1.6 Single 5A round pin socket outlet first point 15 Nos 2,504 37,556
1.7 Single 5A round pin socket outlet point to point 56 Nos 1,878 105,156
1.8 Single 5A round pin socket outlet adjacent 30 Nos 626 18,778
1.9 ceiling fan point with solid state fan speed controller 2 Nos 1,878 3,756
1.11 Exhaust fan point with 5A socket outlet/ controlled by one switch 32 Nos 1,878 60,089
Same as item No. 1 above but point wiring for Emergency light fixture with
2.0 0 Nos 1,878 -
3cx1.5mmsq PVC/PVC 600/1000V copper conductor cable as follows:
Emergency Lights
2.1 Point Wiring Emergency light / exit sign point, from DB with 5A socket outlet 7 Nos 3,130 21,907
2.2 Emergency light / exit sign point with 5A socket outlet, from point to point 22 Nos 1,878 41,311
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Providing and fixing up of External flood light-point wiring from LPDB/DB with
3c x 4.0mmsq PVC/PVC installed copper conductor cable in PVC conduit
rigid/flexible (clipped to the surface, or concealed in structure, or underfloor), or in
3.0 already laid cable trunking or in surface extra light GI conduit (external/roof)
External Flood including all wiring & termination accessories, sheet steel back boxes, locally
Lights Point manufactured PVC junction boxes (100mm x 100mm x 75mm) with PVC glands
Wiring with phase and earth terminals, flexible conduits and connectors as follows:
3.1 Flood light point, controlled by DB mounted pushbutton via MCB 1 No 5,007 5,007
Same as item No. 1 above but circuit and point wiring with 3cx2.5mmsq
4.0 PVC/PVC 600/1000V copper conductor cable including all accessories with 13A
flat pin switched socket outlet or 16A Schuko Socket outlet as follows:
13A Flat Pin
Socket Point
4.1 Wiring Single 13A flat pin socket outlet or 16A schuko socket outlet first point 11 Nos 2,504 27,541
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. 13ANAME
Flat Pin QUANTITY RATE
Socket Point AMOUNT (Rs.)
(Rs.)
Wiring
4.2 Single 13A flat pin socket outlet or 16A schuko socket outlet from point to point 26 Nos 1,878 48,822
4.3 Single 13A flat pin socket outlet adjacent 4 Nos 626 2,504
Same as item No. 1 above but circuit and point wiring with 3cx4.0mmsq
5.0 PVC/PVC 600/1000V copper conductor cable including all accessories with 15A
15A Round Pin round pin switched socket outlet as follows:
Socket Point
Wiring
5.1 Single 15A round pin socket outlet first point 4 Nos 2,504 10,015
5.2 Single 15A round pin socket outlet point to point 3 Nos 1,502 4,507
Same as item No.1, above but point wiring for Alarm & Control Panels from DB
6.0 with 3c x 2.5mmsq PVC/PVC 600/1000V grade copper conductor cable including
Alarm and Control all accessories as follows:
Panels Point
Wiring
6.1 FACP (with 16A schuko socket outlet) 3 Nos 2,504 7,511
6.2 MDF / IDF / CCTV Racks (16A SP IP44 industrial socket with plug) 10 Nos 2,504 25,037
Same as item No. 1 above but wiring for Surface mounted multiple industrial
socket outlet (CEE) board, from DB with multi-core 5c x 6.0mmsq PVC/PVC
7.0
600/1000V grade copper conductor cable complete with glands and all
accessories as follows:
7.1 multiple industrial socket outlet (CEE) board, first point 4 Nos 4,381 17,526
7.2 multiple industrial socket outlet (CEE) board, from point to point 2 Nos 3,756 7,511
CEE Board Point Providing & fixing up of Surface mounted multiple industrial socket outlet (CEE)
Wiring board IP44 protection complete with wall mounting arrangement, circuit breakers,
industrial sockets and plugs using following fittings:
8.0 - 1 x 32A 5pin industrial socket 6 Nos 3,756 22,533
- 1 x 16A 3pin industrial socket
- 1 x 4p ELCB 30mA trip
- 1 x 2p ELCB 30mA trip
Same as item No. 7 above but Surface mounted multiple industrial socket outlet
8.1 (CEE) board IP67/weatherproof protection complete with all wall mounting 0 Nos - -
arrangement, circuit breakers, industrial sockets and plugs
Same as item No. 1 above but wiring for industrial socket outlet from DB with
multi-core PVC/PVC 600/1000V grade copper conductor cable complete with
9.0
IP44 industrial socket and plug, junction boxes, sheet steel back box and all
accessories as follows:
9.1 16A 3-pin SP industrial socket 3c x 4.0mmsq, first point 3 Nos 3,130 9,389
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Industrial Socket
9.3 Point Wiring 16A 5-pin TP industrial socket (IP67) 5c x 4.0mmsq, first point (For Pumps) 0 Nos - -
9.4 32A 3-pin SP industrial socket 3c x 4.0mmsq, for UPS 2 Nos 6,259 12,519
9.7 63A 3-pin SP industrial socket 3c x 6.0mmsq, for UPS 6 Nos 3,130 18,778
Same as item number 1 but, point wiring for miscellaneous equipment complete
with multicore PVC/PVC 450/750V copper conductor cables with IP44 standard
10.0 - -
imported wall mounted, load break switches (switch disconnector type), lockable
handle with IP44 rated cable glands and all accessories:
10.1 20A DP IP44 (AC-23) for roller shutter door with 3c x 2.5mmsq 3 Nos 3,756 11,267
LBS Point Wiring
10.2 40A FP IP44 (AC-23) for Dock Leveler with 5c x 6.0mmsq 0 Nos - -
Hand Dryer Point Same as item No.1, above but point wiring for hand dryers with 3 x 1c x 4.0mmsq
11.0 3 Nos 3,130 9,389
Wiring PVC insulated conductor cable from DB
Providing & fixing up of wiring for Split AC indoor unit with single core copper
conductor cables in surface extra light GI conduit/concealed PVC conduit with
12.0
sheet steel junction boxes back boxes, connectors, etc. and all required
accessories as follows:
Split AC Point
12.1 Wiring 1 & 1.5 Ton, 20A DP isolator switch socket with 3 x 4mmsq PVC cable 36 Nos 3,130 112,667
12.2 2.0 & 2.5 Ton, 25A DP isolator switch socket with 3 x 6mmsq PVC cable 3 Nos 4,381 13,144
12.3 4.0 Ton, 32A DP isolator switch socket with 3 x 6mmsq PVC cable 0 Nos. - -
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Wifi Access Installation & connecting up of "Owner Supplier" wifi access device fixed to
16.0 1 No. 6,259 6,259
Device ceiling/walls with supports
Providing & fixing up of push buttons station for remote control operation of lights,
17.0 complete with IP44 press push button mounted on surface type back box and all 2 Nos 3,756 7,511
accessories
Push Button for
remote controlling
Providing & fixing up of push buttons control point wiring from (already provided)
push button to contactor in distribution board with 3c x 2.5mmsq PVC/PVC
17.1 2 Nos 9,389 18,778
flexible cable in PVC/GI conduit, sheet steel junction box complete with all
accessories
B SURFACE CONDUITING
Providing & fixing up of Point wiring (including circuit wiring with 3c x 2.5mmsq
PVC/PVC) with 3c x 1.5mmsq PVC/PVC 600/1000V grade copper cable installed
in surface extra light GI conduit, or in already laid cable trunking (Vertical drops to
be in surface EMT conduits) including all wiring accessories, ceiling rose, 10A
18.0
switch, switch socket outlet, solid state fan speed controller, sheet steel back
boxes, localy manufactured PVC junction boxes (100mm x 100mm x 75mm) with
PVC glands with phase and earth terminals, 1.0mmsq 3-core flexible PVC/PVC
cord in flexible PVC conduit upto fixture, etc for:
18.1 Light point, controlled by DB mounted pushbutton via MCB 11 Nos 3,130 34,426
Point Wiring
18.2 Light point, controlled by one switch 3 Nos 2,504 7,511
INSTALLATION
ITEM Point Wiring
COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
18.4 Insect killer point from DB with 5A round pin socket outlet 1 Nos 2,504 2,504
18.5 Insect killer point to point with 5A round pin socket outlet 6 Nos 2,504 15,022
18.6 Insect killer point to point with 5A round pin socket outlet (weatherproof) 3 Nos 3,130 9,389
18.8 Single 5A round pin socket outlet point to point 2 Nos 2,504 5,007
Same as item No.18 above but point wiring for Emergency light fixture with
19.0
3cx1.5mmsq PVC/PVC 600/1000V copper conductor cable as follows:
Emergency Lights
19.1 Point Wiring Emergency light / exit sign point, from DB with 5A socket outlet 2 Nos 2,504 5,007
19.2 Emergency light / exit sign poin with 5A socket outlet, from point to point 9 Nos 2,504 22,533
Same as item No.18 above but Circuit and point wiring for Highbay Lights with
20.0
3cx2.5mmsq PVC/PVC 600/1000V copper conductor cable as follows:
Highbay Lights
20.1 Point Wiring Light point, controlled by DB mounted pushbutton via MCB 3 Nos 2,504 7,511
Providing and fixing up of External flood light-point wiring from LPDB/DB with
3c x 4.0mmsq PVC/PVC installed copper conductor cable in PVC conduit
rigid/flexible (clipped to the surface, or concealed in structure, or underfloor), or in
21.0 already laid cable trunking or in surface extra light GI conduit (external/roof)
External Flood including all wiring & termination accessories, sheet steel back boxes, locally
Lights Point manufactured PVC junction boxes (100mm x 100mm x 75mm) with PVC glands
Wiring with phase and earth terminals, flexible conduits and connectors as follows:
21.1 Flood light point, controlled by DB mounted pushbutton via MCB 3 Nos 3,130 9,389
21.2 Flood light point, from point to point 3 Nos 2,504 7,511
Same as item No. 18 above but wiring for surface mounted multiple industrial
socket outlet (CEE) board, from DB with multi-core 5c x 6.0mmsq PVC/PVC
22.0
600/1000V grade copper conductor cable complete with glands and all
accessories as follows:
22.1 multiple industrial socket outlet (CEE) board, first point 3 Nos 3,130 9,389
22.2 multiple industrial socket outlet (CEE) board, from point to point 4 Nos 3,756 15,022
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
CEE Board Point Providing & fixing up of Surface mounted multiple industrial socket outlet (CEE)
Wiring board IP44 protection complete with wall mounting arrangement, circuit breakers,
industrial sockets and plugs using following fittings:
23.0 - 1 x 32A 5pin industrial socket 5 Nos 3,756 18,778
- 1 x 16A 3pin industrial socket
- 1 x 4p ELCB 30mA trip
- 1 x 2p ELCB 30mA trip
Same as item No. 22 above but Surface mounted multiple industrial socket outlet
23.1 (CEE) board IP67/weatherproof complete with all wall mounting arrangement, 2 Nos 6,259 12,519
circuit breakers, industrial sockets and plugs
Same as item No. 18 above but wiring for industrial socket outlet from DB with
multi-core PVC/PVC 600/1000V grade copper conductor cable complete with
24.0
IP44 industrial socket and plug, junction boxes, sheet steel back box and all
accessories as follows:
24.3 16A 5-pin TP industrial socket (IP 67) 5c x 4.0mmsq, first point (For Pumps) 0 Nos - -
24.4 32A 5-pin TP industrial socket 3c x 6.0mmsq, first point 1 Nos 6,259 6,259
Only Conduit .
Wiring Cable OFM
24.5 32A 5-pin TP industrial socket 3c x 6.0mmsq, point to point 1 Nos 9,389 9,389
Same as item number 18 but, point wiring for miscellaneous equipment complete
with multicore PVC/PVC 450/750V copper conductor cables with IP44 standard
25.0
imported wall mounted, load break switches (switch disconnector type), lockable
handle with IP44 rated cable glands and all accessories:
25.1 20A DP IP44 (AC-23) for roller shutter door with 3c x 2.5mmsq 5 Nos 3,756 18,778
25.2 20A DP weatherproof (AC-23) for roller shutter door with 3c x 2.5mmsq 5 Nos 9,389 46,945
25.3 40A FP IP44 (AC-23) for Dock Leveler with 5c x 6.0mmsq 3 Nos 3,130 9,389
LBS Point Wiring
25.4 16A DP IP44 Air curtains with 3c x 2.5mmsq 0 Nos - -
25.6 16A FP IP44 for exhaust fan with 5c x 4sqmm 2 Nos 3,130 6,259
25.8 25A FP IP44 for exhaust fan with 5c x 6sqmm 17 Nos 3,756 63,845
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Providing & fixing up of Point wiring (including circuit wiring with 3c x 2.5mmsq
PVC/PVC) with 3c x 1.5mmsq PVC/PVC 600/1000V grade copper cable installed
in surface GI conduit or in already laid cable trunking (Vertical drops to be in
surface GI conduits) including all wiring accessories, ceiling rose, 10A switch,
26.0
switch socket outlet, solid state fan speed controller, sheet steel back boxes,
localy manufactured PVC junction boxes (100mm x 100mm x 75mm) with PVC
Point Wiring glands with phase and earth terminals, 1.0mmsq 3-core flexible PVC/PVC cord in
flexible PVC conduit upto fixture, etc for:
26.1 Light point, controlled by DB mounted pushbutton via MCB 9 Nos 2,504 22,533
Same as item No. 26 above but Circuit and point wiring for Highbay/Lowbay
27.0 Lights with 3cx2.5mmsq PVC/PVC 600/1000V copper conductor cable as
follows:
Highbay/Lowbay
27.1 Lights Point Light point, controlled by DB mounted pushbutton via MCB 9 Nos 5,007 45,067
Wiring
27.2 Light point, controlled by one switch 0 Nos - -
Providing & fixing up of aluminum junction boxes for hazardous area light point
28.0 Junction Boxes wiring (zone 2/zone 1 rated) with min. 6 cable glands including all termination and 17 Nos. 6,259 106,408
mounting accessories
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Note:
1. This BOQ to be read in conjunction with tender layouts & cable schedules
2. Pr: No. of Pairs
3. The process power & instrumentation cable to be as per process consultant's specifications/ must be compatible with equipment
4. Building # 08 (TPQ) is considered as non hazardous.
3. Building # 01, 03, 04/07 (NC Varnish, LIH, FG & RM Store respectively) are considered as hazardous areas (zone 1/2 rated)
3.0 Same as item number 1, but PVC/PVC Flexible cable for UPS incoming and outgoing
Copper Cable
3.1 3c x 16mmsq
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Supply, installation & connecting up of 450/750V grade Aluminium conductor cable
as CPC, in PVC conduit, clipped to the surface, or concealed in structure, or in
5.0
already laid cable tray, including all fixing, jointing tee/c clamps & termination
accessories, etc., in the following sizes:
5.1 95mmsq PVC 830 Mtr 150 124,685
CPC
5.2 70mmsq PVC 600 Mtr 100 60,089
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
11kV Cable
9.1 3c x 240mmsq (Al) 1800 Mtr 1,001 1,802,672
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
Providing & fixing of GI (pre-galvanised sheet steel) cable trunking with cover
including all accessories, bends, tees, reducers, clamps, hooks, bolts, etc., complete
1.0 in all respect in the following sizes: (only strut-channel HDGAF supports are
acceptable as horizontal support) vertical Hangers pre-galvanised 10mm dia threaded
rods with steel roof clamps as follows:
Cable Trunking
1.1 150 x 100mm (1.2mm) 150 Mtr 377 56,614
Providing & fixing of GI (pre-galvanised sheet steel) cable tray including all
accessories, bends, tees, reducers, clamps, hooks, bolts, etc., complete in all respect
including following type of supports in the following sizes:
a.) For Suspended Cable Trays:
Only strut-channel HDGAF supports are acceptable as horizontal support.
2.0
Vertical Hangers pre-galvanised 10mm dia threaded rods with steel roof clamps
Cable Tray
2.1 50 x 50mm (1.5 mm) with 1.5mm GI Cover 2390 Mtr 252 601,364
2.2 100 x 50mm (1.5 mm) with 1.5mm GI Cover 60 Mtr 315 18,871
2.3 100 x 100mm (1.5 mm) with 1.5mm GI Cover 1930 Mtr 315 607,025
2.4 150 x 100mm (1.5 mm) with 1.5mm GI Cover 260 Mtr 377 98,131
2.5 200 x 100mm ( 1.5mm) with 1.5mm GI Cover 450 Mtr 503 226,455
2.6 300 x 100mm ( 1.5mm) with 1.5mm GI Cover 240 Mtr 881 211,358
2.7 450 x 100mm ( 2.0mm) with 1.5mm GI Cover 150 Mtr 1,069 160,406
2.8 600 x 100mm (2.0 mm) with 1.5mm GI Cover 180 Mtr 1,195 215,132
Providing & fixing of HDGAF cable ladder (300mm rung spacing) including all
HDGAF accessories bends, tees, cross over, junction boxes, reducers, clamps,
3.0 hooks, bolts, hanger, etc., (only strut-channel HDGAF supports are acceptable as
horizontal support) vertical Hangers pre-galvanised 10mm dia threaded rods and all
accessories as follows:
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
3.1 100 x 100mm, 14 gauge (2.0mm) without cover 210 Mtr 315 66,049
3.2 150 x 100mm, 14 gauge (2.0mm) without cover 60 Mtr 377 22,646
3.3 200 x 100mm, 14 gauge (2.0mm) without cover 140 Mtr 503 70,453
3.4 Cable Ladder 300 x 100mm, 14 gauge (2.0mm) without cover 190 Mtr 881 167,325
3.5 450 x 100mm, 10gauge ( 3.4 mm) without cover 210 Mtr 1,069 224,568
3.6 600 x 100mm, 10gauge ( 3.4 mm) without cover 60 Mtr 1,195 71,711
100 x 100mm, 14 gauge (2.0mm) with 16 gauge GI cover 120 Mtr 315 37,743
3.7 200 x 100mm, 14 gauge (2.0mm) with 16 gauge GI cover 50 Mtr 503 25,162
3.8 300 x 100mm, 14 gauge (2.0mm) with 16 gauge GI cover 30 Mtr 629 18,871
3.9 450 x 100mm, 10 gauge (3.4mm) with 16 gauge GI cover 40 Mtr 755 30,194
NOTE:
The mentioned lengths are tentative based on tender drawings. The actual total cable tray/trunking lengths and their associated bends, tees, cross over, junction boxes etc to be gotten measured and verified on site by contractor before
ordering/manufacturing.
INSTALLATION
COMPONENT TOTAL
ITEM NO. ILLUSTRATION DESCRIPTION UNIT Make Model
NAME QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
Supply installation & connecting up of Indoor type termination kits for 11kV cable
1.0
with copper lugs / bimetallic lugs and all accessories as follows:
MV Termination
1.1 Kits 3c x 240mmsq (Al) 2 sets 3,145 6,290
Providing and Fixing up of control wiring with 3cx2.5mmsq multi core conductor
PVC/PVC flexible copper cable (with 25% spare cores) in surface GI conduit or in
2.0
already laid cable tray or RCC/HDPE pipe including all laying & termination
accessories as follows:
Control Wiring Temperature relay alarm & trip wiring between MV panels & Transformer mounted
2.1 4 lot 31,452 125,808
relays
2.2 Buchholz relay alarm & trip wiring between MV panels & Transformer mounted relays 4 lot 31,452 125,808
Providing & fixing up of two (2) hour rated fire stopping measures for present &
3.0 future cable raceway/pipes passing through electrical/comm rooms floors & walls in
all electrical/comm rooms at all levels including all required fillers etc., as follows:
Fire Stopping
3.1 fire stopping mortar 650 kg 189 122,663
Providing & fixing up of Emergency ON/OFF push buttons for remote ON/OFF of
4.0 MV Panel complete with industrial grade mushroom head push button with key mount 4 lot 1,258 5,032
in a wall mounted lockable cabinet in Building
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION EXTERNAL UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Providing & fixing of point wiring from Feeder Pillar or External DB for
street lights/flood lights with PVC insulated copper conductor cable
1.0 installed in buried 50mm dia HDPE pipe or RCC pipe or surface GI pipe,
with all excavation, backfilling, markers,drawpits and all termination
accessories:
Point Wiring
1.1 pole light point, with 5x 1c x 6.0mmsq PVC/PVC 54 54 Nos 5,661 305,714
1.2 Flood light point, with 5 x 1c x 6.0mmsq PVC 2 2 Nos 5,661 11,323
Providing & fixing of industrial grade weatherproof photocell with all control
2.0 wiring, mounting and fixing accessories to feeder pillars for street lighting 3 3 Nos 2,516 7,549
control
Photocell
Same as item No.1, above but control wiring between photocell to impulse
relays/magnetic contactor in feeder pillar/external DB with multicore
2.1 3 3 Nos 2,516 7,549
1.0mmsq flexible PVC/PVC copper conductor cable 300/500V in surface
extra light GI conduit.
Same as item No.1, above but point wiring for alarm & control panels from
UPSDB with 3c x 2.5mmsq multicore PVC/PVC 600/1000V grade copper
3.0
Point Wiring conductor cable including all accessories with 16A surface mounted
schuko socket & plug:
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
Manholes/ INSTALLATION
ITEM Cable
COMPONENT TOTAL
Chambers ILLUSTRATION DESCRIPTION EXTERNAL UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
Foundation for
Construction of RCC foundation for street lighting poles (see tender
6.0 street lighting 54 54 Nos 6,290 339,683
poles drawings for detail)
7.1 single bracket/arms for one no. street light fixture 37 37 Nos 18,871 698,236
7.2 twin bracket/arms for two nos. opposite street light fixtures 17 17 Nos 18,871 320,811
Providing & fixing up of point wiring from feeder pillars for watch
towers/gate offices etc. with 3 x 1c x 4mmsq PVC insulated copper
conductor cable installed in buried 50mm dia HDPE or RCC pipe or
8.0 Point Wiring surface GI pipe, with all excavation, backfilling, markers & all termination 4 4 Nos 5,032 20,129
accessories with surface mounted weatherproof 10A breaker box for each
watch tower/external etc. complete with earth terminal, 10A DP MCB
breaker and all relevent mounting & fixing accessories etc.
Same as item No. 1 above but wiring for industrial socket outlet from
feeder piller/external DB with multicore PVC/PVC insulated cable complete
9.0
with IP67 industrial socket & plug, junction boxes, sheet steel back box &
all accessories:
Industrial Sockets 16A 3-pin SP industrial socket for CCTV cabinet switches with 3c x 4mmsq
9.1 8 8 Nos 3,774 30,194
cable
9.2 32A 5-pin TP industrial socket with 5c x 6mmsq cable 2 2 Nos 6,290 12,581
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
ITEM COMPONENT TOTAL
Point Wiring ILLUSTRATION DESCRIPTION EXTERNAL UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
10.8 15A 3-pin socket outlet , first point 1 1 Nos 2,516 2,516
10.11 Exhaust fan point with 5A socket outlet/ controlled by one switch 1 1 Nos 2,516 2,516
INSTALLATION
NOTE:
1. The mentioned lengths are tentative based on tender drawings. The actual total cables lengths to be gotten measured and verified on site by contractor before Ordering/Manufacturing.
Supply, installation and connecting up of buried ring earth electrode around the
perimeter of the buildings complete with 70mmsq bare copper conductor (Pioneer
Cables Ltd. Khi, Pakistan Cables Ltd. Khi, Newage Cables Lhr, Fast Cables Lhr,
Indus Cable Khi) for connection between earth bars (test links), foundation earth
1.0 1205 Mtr 252 303,198
electrode & rod earth electrode to act as a ring earth electrode by already provided
exothermic welds complete with all clamps, lugs, ties, connection, insulator, supports
accessories buried in ground with excavation and backfilling and connecting
accessories
Ring Earth
Electrode
Providing and fixing up of 70mmsq PVC Copper conductor (Pioneer Cables Ltd. Khi,
Pakistan Cables Ltd. Khi, Newage Cables Lhr, Fast Cables Lhr, Indus Cable Khi) for
1.1 connection between earth bars, earth electrode, foundation by already provided 2010 Mtr 101 202,300
exothermic welds complete with all clamps, lugs, ties, connection, insulator, supports
accessories
Rod Earth Providing & fixing up of rod earth electrode, comprising of 16mm dia, 3.0m length
Electrode copper rod, immersed in water through bore hole upto water table complete with
2.0 21 Set 44,033 924,691
(Copper cladded heavy duty test pit/inspection well and all accessories & material (minimum 80-100
steel rod) feet)
EGBs
3.1 450 x 80 x 10mm (08 ways) EGB + Twin disconnecting links 126 Nos. 1,258 158,519
3.2 600 x 80 x 10mm (10 ways) EGB + Twin disconnecting links 3 Nos. 1,006 3,019
INSTALLATION
Exothermic Making exothermic welding connections among conductors, earth bars, steel
4.0 82 Nos. 629 51,581
Welding columns/RCC etc.
Making steel spot welding connections among conductor, earth electrode, columns,
Steel Spot
5.0 earth bars etc. by already provided rebar protrusions (~600mm) (provided by civil 83 Nos. 881 73,095
Welding
contractor)
Supply, installation & looping with braided (70mmsq) copper terminals earth braids
6.1 2300 Nos. 189 434,039
(flexible cable bonding straps Indus cables, Karachi) of cable tray lengths
Copper Braided
terminal for
bonding
Supply, installation & looping with braided (25mmsq) copper terminals earth braids
6.2 150 Nos. 189 28,307
(flexible cable bonding straps Indus cables, Karachi) of cable tray lengths
Equipotential
Bonding
Conductor (PVC 95mmsq Copper PVC for equipotential bonding of equipment (electrical &
7.1 100 Mtr 151 15,097
Insulated Copper communication)
Conductor)
70mmsq Copper PVC for equipotential bonding of equipment (electrical &
7.2 1200 Mtr 101 120,776
communication)
25mmsq Copper PVC for equipotential bonding of equipment (cable tray) &
7.3 500 Mtr 82 40,888
mechanical pipes, ducts, etc.
INSTALLATION
Testing,
Continuity testing, measurement & documentation of earth electrode system
9.0 Measurement & 1 Job 81,775 81,775
resistance
Documentation
3 Testing & Commissioning of complete project including handing over to client Weeks
NOTES TO COMPLY
Note
Description Compliance Deviation
No.
1 Contractor/Supplier to add in his quoted cost any other item required for completion of LPS
as per manufacturer requirement
2 All offered components to be of single make
3 Certificate of compliance to NFC 17-102-2011 standard for each offered component and
complete offered solution/system from manufacturer to be submitted
4 After award of works, risk assesment report with reconfirmation of protection level to be
submitted
5 After award of works, scaled shop drawing showing location of arrestor with coverage
diameter, roof and down conductor, test link and earth electrodes to be submitted
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
RATE AMOUNT
ITEM DIMENSION COLOR LUMEN TOTAL
FIXTURE ID DESCRIPTION SYMBOL IMAGE INSTALLATION CRI WATTS HOURS APPLICABLE AREAS EXTERNAL UNIT Make Model
NO. DxWxH (mm) APPEARANCE OUTPUT QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
Notes:
1. Contractor/Supplier to state equipment delivery timelines.
2. Contractor/Supplier to provide three years of warranty from date of commissioning.
3. Each individual light fixture to must have its own driver.
4. False ceiling-mounted light fixtures shall be compatible with mounting frame (to be included in cost) and fit exactly into the false ceiling.
5. All hazardous fixtures (Zone-1 and Zone-2 classified) to have all mounting and installation accessories to be hazardous grade/Atex classified.
A Supply, installation & connecting up of light fixtures with lamps, drivers, holders etc. including all mounting, suspension and fixing materials, swivel-mounts, brackets, chains, hooks, clamps etc. as follows:
High Bay
1 A1
(IP-65)
- Suspended 5000 - 5500K >80 126 20,000 50,000 TPQ/Offset Hall 30 Nos 2,516 75,485
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
RATE AMOUNT
ITEM DIMENSION COLOR LUMEN TOTAL
FIXTURE ID DESCRIPTION SYMBOL IMAGE INSTALLATION CRI WATTS HOURS APPLICABLE AREAS EXTERNAL UNIT Make Model
NO. DxWxH (mm) APPEARANCE OUTPUT QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
LED Symmetric
Wide Beam Flood Loading & Un-loading
8 G - Wall/ Pole 5000 - 5500K >80 120 12,000 50,000 3 10 Nos 3,145 31,452
Light Area, External
(Weatherproof)
LED Symmetric
Wide Beam Flood
9 H
Light
- Wall 5000 - 5500K >80 50 4,300 50,000 Terace 2 Nos 2,516 5,032
(Weatherproof)
B Supply, installation & connecting up of light fixtures with lamps, drivers, holders etc. including all mounting, suspension and fixing materials, swivel-mounts, brackets, chains, hooks, clamps, atex-rated glands etc. as follows:
Low Bay
(IP-66)
(flame proof
1 A2
housing)
- Suspended 5000 - 5500K >80 60 8,000 50,000 NC Varnish Manufacturing 20 Nos 6,290 125,808
Zone 1-Atex
category 2
High Bay
(IP-66)
(flame proof Liquid Ink Hall, RM & FG
2 A3 - Suspended 5000 - 5500K >80 126 20,000 50,000 61 Nos 6,290 383,715
housing) Store
Zone 1-Atex
category 2
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
RATE AMOUNT
ITEM DIMENSION COLOR LUMEN TOTAL
FIXTURE ID DESCRIPTION SYMBOL IMAGE INSTALLATION CRI WATTS HOURS APPLICABLE AREAS EXTERNAL UNIT Make Model
NO. DxWxH (mm) APPEARANCE OUTPUT QUANTITY
RATE
AMOUNT (Rs.)
(Rs.)
LED Batten
IP-67
Liquid Ink Hall, NC Varnish
(Aluminum fame Surface on
3 B3
proof housing) ≈ 1200 Ceiling/wall
5000 - 5500K >80 34 4,000 50,000 Manufacturing, RM & FG 70 Nos 6,290 440,329
Zone 1-Atex Stove
category 2
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (4) (5) (8) (9) (12) (13)
A Installation and connecting up of maintained/non-maintained (1/1.5hr) rechargeable Ni-Cad battery operated emergency escape route lights/exit signage including all required suspension and mounting accessories as follows:
6W
Twin head adjustable
Surface mounted LED
1 EL-1 emergency spot light 1.5 hr. 220 IP 44 TPQ, Offset Hall 16 Nos 1,887 30,194
(Ceiling/ Wall)
Suspended from 8W
Single sided with Ceiling/ LED Office area
4 EX-1 Pictogram
1 hrs. 30 IP 44 3 Nos 1,258 3,774
Surface
8W
Double sided with Suspended from
LED
5 EX-2 Pictogram Ceiling/ 1 hrs. 30 IP 44 --- 0 Nos 1,258 -
Surface
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION EXTERNAL UNIT Make Model
NO. NAME QUANTITY RATE
AMOUNT (Rs.)
(Rs.)
(1) (2) (3) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
ITEM COMPONENT TOTAL
ILLUSTRATION DESCRIPTION EXTERNAL UNIT Make Model
NO. NAME
Distribution QUANTITY RATE
AMOUNT (Rs.)
Boards (Rs.)
Providing & fixing up of weather proof epoxy painted, feeder pillars complete with gland plates, floor stand 600mm high, weatherproof gasket
4.0
construction as follows:
Supply of handheld battery operated power supply for electronic trip of circuit
5.0 Power supply 1 No 12,456 12,456
breakers for programming & trip testing during OFF load conditions
Supply, installation & connecting up of following including all mounting, suspension and fixing accessories, etc:
Insect Supply, installation & connecting up of 360 degree insect killer "MOEL,
4 23 Nos 1,246 28,649
Killer ITALY CRI-CRI 309" including all suspension & mounting accessories
INSTALLATION
ITEM COMPONENT TOTAL RATE AMOUNT
ILLUSTRATION DESCRIPTION UNIT Make Model
NO. NAME QUANTITY
RATE AMOUNT
(Rs.) (Rs.)
Supply, installation & connecting up of 0.9 power factor, Double conversion on-line, UPS with battery backup, with original manufacturer supplied
1.0
battery, SNMP through owners LAN with e-mail/remote alarm capability, environmental monitoring probe, as follows:
1.3 8kVA, 1-Ø (built in battery backup of 10 minutes) 2 Nos 31,141 62,281
(1) (2) (3) (a) (b) (c) (d) (e) (f) (g) (h) (4) (5) (8) (9) (12) (13)
INSTALLATION
ITEM COMPONENT NC FG & RM ANCILLARY TOTAL RATE AMOUNT
ILLUSTRATION DESCRIPTION LIH TPQ
VARNISH STORE
DG STORE NC STORE
BUILDING
EXTERNAL UNIT Make Model
NO. NAME QUANTITY
RATE AMOUNT
(Rs.) (Rs.)
INSTALLATION
Providing & fixing up of QR code and cloud data hosting (10MB data for
1.0
each panel) of following already supplied panels:
INSTALLATION
INSTALLATION
Same as item no. 1 above, but data outlet wiring point in concrete building
1.2 44 Nos 3,130 137,704
in concealed/surface PVC conduit or in already provided GI cable trunking
Supply, installation and connecting up of 19" rack mounted Category 6A F/UTP multiport modular (RJ45) jack patch panels system, installed in
2.0 already provided racks, including cable management trough, splicing, patch connector, labels, label holders, cable guide horizontal & vertical, etc. as
follows:
3.0 Providing & fixing up of 19" IT System Cabinet/Racks for above IDF as follows:
INSTALLATION
Supply, installation & connecting up of outdoor rated fiber optic cable (CORNING) with all required laying & termination accessories in 38mm dia surface GI conduit or
5.0 in already laid surface GI cable trunking or in buried HDPE/RCC pipe complete with excavation, backfilling, sand bedding, warning tape, labels, laying and termination
accessories
5.1 FO Cable 8 core fiber optic cable (single mode OS2, G657, 9/125µm) 1300 Mtr 438 569,594
Providing & fixing up of 19" fiber optic patch panels complete with all required splicing, patching, pigtails, connectors, labeling, termination & cable management trough
6.0
with accessories as follows:
INSTALLATION
7.0 Supply, installation & connecting up of copper cable Cat 6A F/UTP, 100 ohm, 4 x 2 x AWG 23/1 cord with modular plugs as follows:
Testing &
8.0
Certification
Testing & certification of complete data system 1 Job 375,557 375,557
INSTALLATION
QUANTITY
TOTAL
ITEM COMPONENT
ILLUSTRATION DESCRIPTION UNIT Make Model Remarks
NO. NAME
RATE
AMOUNT (Rs.)
(Rs.)
1.0 Analogue addressable Fire Alarm System in compliance with NFPA/UL 864 standards and FM Global approval, comprising of:
2-loop slave analogue addressable fire alarm control panel (expandable 4-loop addressable
a upto 4 loops) including 2 Notification Appliance Circuits, with extra power 2 Nos 93,889 187,778 Siemens FC924 compact fire alarm control
supplies for sounders (if required) panel
i) 2-loop Master
addressable compact fire
1-loop Master analogue addressable fire alarm control panel (expandable alarm control panel
a upto 2 loops) including 1 Notification Appliance Circuits, with extra power 1 No 125,186 125,186 Siemens FC922 ii) Non UL listed Printer
supplies for sounders (if required) also considered with
Master Fire Alarm Control
Master Fire Alarm Panel
1.2
Control Panel
FN2006-
Fibre optic peer to peer interface card/ gateway, installed inside already U1 +
b 1 No 43,815 43,815 Siemens
provided FACP enclosure FN2001-
U1
Optical Smoke
Detector
Optical Multi
criteria Detector
1.7 Heat detector Analogue addressable point-type heat (rate of rise + fixed temperature) detector 6 Nos 1,362 8,170 Siemens HI921 + DB-11
Heat detector with Analogue addressable point-type heat (rate of rise + fixed temperature) detector
1.8 RO No -
Sounder with base sounder
i) Approvals
UL listed, wire- powered, reflective imaging (single IR) beam detector (0- OSI-10 UL, ULC
100m range) including input/output module reflector/emitter; auto align, OSE-SPW FM & CSFM & VdS
Xtrails + RTS151KIT
a auto optimize, resistant to object intrusion, resistant to sunlight, resistant to 4 Nos 31,296 125,186 ii) Beam Detector
Siemens +
building movement with integral sensitivity testing, adjustable brackets, communicates through
remote test unit, test filters along with its installation kit XTRI-D addressable dual input
1.9 Beam Detector
Module
Analogue addressable manual pull station, double action with (poly carbonate With Poly Cardonate STI
1.10 34 Nos 1,252 42,563 Siemens
XMS-D + STI 3150
based) protective cover Covers
INSTALLATION
QUANTITY
TOTAL
ITEM COMPONENT
ILLUSTRATION DESCRIPTION UNIT Make Model Remarks
NO. NAME
RATE i) With Poly Cardonate
AMOUNT (Rs.)
(Rs.) STI Covers
ii) Provided manual pull
station not NEMA3R
rated, NEMA rated
enclosures are self-
certified by the
MSM-KD- manufacturer and They
Manual Pull Analogue addressable manual pull station (weather-proof/outdoor) NEMA 3R WP + do not require a third-
1.11 9 Nos 1,878 16,900 Siemens
Station rated, double action with poly carbonate based tamper resistant protective cover XTRI-M + party testing, whereas UL
STI 3150 rated devices must go
through a rigorous testing
and complete a
i) Without Poly
compliance Cardonate
process
STI Coversby a UL
performed
ii) Providedtest
accredited manual pull
facility,
station
offered not NEMA3R
weather proof pull
rated, NEMA rated
station is UL listed.
enclosures are self-
certified by the
manufacturer and They
Analogue addressable manual pull station (Explosion proof zone1/2 rated) NEMA MSM-EXP do not require a third-
1.12 5 Nos 3,756 18,778 Siemens
4X rated, double action + XTRI-M party testing, whereas UL
rated devices must go
through a rigorous testing
and complete a
compliance process
performed by a UL
accredited test facility,
offered weather proof pull
station is UL listed.
Sounder with
flasher
Max.125 dB
EN Approved (EN 60079-
Analogue addressable electronic sounder/horn (explosion proof, zone 1/2 rated),
1.15 Horn/Sounder 5 Nos 6,259 31,296 Siemens DB3B + HCP0,EN 60079-1,EN 60079-
120dB/m 31)
Baseefa13ATEX0231X
a Monitoring of fire suppression valves and switches 15 Nos 1,853 27,799 Siemens FDCIO422 4 Input / 4 Output Module
d Access control system to release all access doors 3 Nos 1,853 5,560 Siemens FDCIO422 4 Input / 4 Output Module
Addressable four contact loop powered relay module in weather proof enclosure
1.18 7 Nos 1,853 12,973 Siemens FDCIO422 4 Input / 4 Output Module
for: monitoring of fire pump room valves/controllers
Single phase, 50Hz, 230V electronic voltage stablizer for control panels with
1.19 Voltage Stablizer 3 No 5,949 17,846 Local Local
stainless steel wall mounted bracket
QUANTITY
1.20
TOTAL
ITEM Detection
COMPONENTModule
ILLUSTRATION DESCRIPTION UNIT Make Model Remarks
i) Approvals
NO. NAME
RATE ATEX Ex II 2 G D, IECEx
AMOUNT (Rs.)
(Rs.) & FM
EN54-10
ii) Flame Detector
Conventional IR3 (wall-mounted, video imaging) flame detector, hazardous communicates through
d 9 Nos 56,333 507,001 Tyco 516.300.413FC
area (zone 1/2 rated) dry contact with Panel'
iii) Wall mounted with
range of max. 65 Meters
Class A wiring of fire alarm system components: manual pull stations, iv) Triple infrared flame
electronic sounders, smoke/heat/multi-criteria/beam/flame detectors, loop detector with NTSC
isolator modules, additional power supply and relay modules from Fire camera
Alarm Control Panel (FACP) with shielded "standard" fire-resistant cable
18AWG extralight GI
compliant to EN 50200 PH-30 (2c x 1.5 mmsq for SLC & 2c x 2.5 mmsq
Cavicel/Dr Cavicel/Dr conduit rates quoted
a for NAC),in concealed PVC conduit or surface extra light GI conduit 245 Nos 4,932 1,205,949
aka/Equiva aka/Equiva cable is OFM
rigid/flexible, external in GI pipe on surface or buried in ground inside lent lent
HDPE/RCC pipe including hand hole, draw pits, galvanized sheet steel
100 x 100 x 75mm surface mounted back boxes/pull boxes, brass bushes,
glands, cable sleeves, hazardous area glands, etc., complete with all
accessories
Cabling &
2.0
Conduiting
Same as item 2 above, but single mode outdoor rated fiber optic (OS2,
c 1000 m 586 585,868 Corning Corning 50mm dia HDPE pipe.
G657, 9/125μm) network cabling between already provided FACPs
Remote alarm
GSM/WEB interface module/gateway (PTA approved) for automatic/scheduled SMS generation module is
4.0 generation 1 No 12,268 12,268 Local Local
module generation of email/message from FACPs at designated owner's mobile numbers case of alarm on FACP
Testing & Testing & commissioning of entire system including development of fire alarm
5.0 1 Job 585,868 585,868 Services Services
Commissioning input/output cause and effect matrix, and training of employer's personnel
3 Testing & Commissioning of complete project including handing over to client Weeks
Note: 1. Offered beam detector must be capable to transmit beam through a gap as small as 40cm (refer datasheet appended with tender document.
2. Contractor to provide manufacturer specific backboxes and bases with offered devices.
3. It is mandatory for contractor to conduct a detailed site-survey prior to bid submission, to understand site and nature of works.
4. Contractor to provide equipment delivery and project installation timelines.
5. Contractor to arrange all necessary installation tools and accessories (including scaffolding/cherry picker etc.) at his own cost.
6. Contractor to ensure adherence to client's HSE guidelines and on-site work standards, in his quoted cost.
7. N/A = Not Applicable
8. Power supply for beam detectors is specified in Lot. Contractor/ supplier to quote exact quantity after current calculations to power
up all offered beam detectors with above FACP.
9. RO = Rate Only
(1) (2) (3) (4) (4) (6) (9) (10) (12) (13)
Notes
1. All cameras to have basic level analytics as specified in technical specifications.
2. For all type of cameras, built in Mic to be provided at Building/Premises Entry/Exit points and reception areas.
3. DORI (Detection, Observe, Recognize & Identify) specifications for all offered cameras respectively must meet at least 60.25.12.06 meters requirements.
4. This BOQ to be read in conjunction with layouts and schematics.
5. All offered products to must have at-least 7 years life cycle support (including updates of patch, firmware upgrade, hardware replacement support, software revision) available from manufacturer.
6. All offered network switches must be of same make/brand.
7. Building # 08 (TPQ) is considered as non hazardous.
8. Building # 01, 03, 04/07 (NC Varnish, LIH, FG & RM Store respectively) are considered as hazardous areas (zone 1/2 rated)
Supply, installation & connecting up of ONVIF compliant IP POE CCTV system (Dahua
Area where Camera Mounting IR
1 WizMind 7/ WizSense series & Hikvision Accusense series), with all mounting, Housing Mounting Mode Resolution Camera Lens
installed type device Illumination
suspension and fixing accessories, etc. as follows:
Motorized
Varifocal
Type-A: Surface/ Surface/In- Auto Yes (upto
a) Office, LAB Indoor Dome 4MP 2.7mm- 4 Nos 1,868 7,474
Dome Camera ceiling ceiling mount D/N 30m)
12mm
Motorized
Process lines,
Varifocal
Type-B: Warehouse, Surface/ Surface/ Wall Auto Yes (upto
b) Indoor Bullet 4MP 2.7mm- 44 Nos 1,868 82,211
Bullet Camera Office, Dining Wall Bracket D/N 30m)
12mm
Area
Motorized
Outdoor Pole/ Pole/Wall/ Varifocal
Type-C1: Box/ Auto Yes (upto
c) External (weatherproof), Wall / Surface 4MP 2.7mm- 28 Nos 1,868 52,316
Bullet Camera Bullet D/N 60m)
vandal resistant Surface Bracket 12mm
Motorized
External Outdoor Pole/ Pole/Wall/
Type-C2: Box/ Auto Yes (upto Varifocal
d) (Boundary (weatherproof), Wall / Surface 4MP 26 Nos 6,228 161,932
Bullet Camera Bullet D/N 60m) 8mm-48mm
Wall) vandal resistant Surface Bracket
Motorized
Varifocal
Outdoor 4.8 mm – 154
Type-D: Dome Auto Yes (upto
e) External (weatherproof), Pole Pole Bracket 2MP mm 2 Nos 6,228 12,456
PTZ Camera PTZ D/N 150m)
vandal resistant (32x Optical
Zoom)
Motorized
Type-E: Stainless Steel, Varifocal
Process lines, Surface/ GI Wall Auto Yes (upto
f) Explosion Proof Bullet Explosion Proof, Bullet 4MP 2.8 mm – 12 9 Nos 6,228 56,053
Warehouse Wall bracket D/N 60m)
Camera Anticorrosive mm
(1) (2) (3) (4) (4) (6) (9) (10) (12) (13)
Type-A:
a) Wall/Pole mounted GI bracket including all required mounting accessories and supports for CCTV cameras 83 Nos 1,246 103,387
GI Wall bracket
Type-B: Outdoor (Weatherproof) GI bracket including all required mounting accessories and supports for external boundary
b) 26 Nos 1,868 48,579
GI Wall bracket wall cameras
Supply, installation & connecting up of Network Video Recorder (NVR), H.265+ encoding capacity, 320Mbps
throughput, 64 channels, 64TB Hard disk with RAID 6 storage including software with licenses
3 NVR + VMS Software 2 Nos 93,422 186,844
(Model of NVR to be of same series as offered with CCTV cameras)
Supply, installation & connecting up of camera point cabling from CCTV cabinets to respective cameras with Category
4 6 UTP (Corning) cable in concealed PVC conduit or surface extra light G.I conduit, including all termination and 48 Nos 3,737 179,370
mounting accessories
Conduit and
Cabling & Conduiting accessories
Same as item 4 above but external camera point cabling in 25mm dia surface GI pipe/buried HDPE pipe including all rates quoted
5 56 Nos 18,684 1,046,327
excavation, sand bedding, backfilling, weatherproof pull boxes, glands, drawpits etc
Same as item 4 above but camera point cabling inside hazardous area (zone 1/2 rated) in 25mm dia surface GI
6 9 Nos 7,474 67,264
conduit (horizontal & vertical drops), including hazardous area termination glands, mounting accessories
Managed Ethernet Supply, installation & connecting up of "main CCTV rack" complete with layer-2, 16 copper POE+ ports + 4 fiber ports,
Switch + Wall/Floor ethernet managed switch (CISCO/Allied telesis/Pheonix contact/ MOXA / Advantech / Dahua/ Hikvision) installed
7 1 Nos 24,913 24,913
Mounted CCTV Main inside wall/floor mounted locally manufactured rack (with lockable door) including fan, cable management, including
Rack power supply, fuses, cabling, termination accessories, fiber & copper patch panels/patch cords complete in all respect
Supply, installation & connecting up of distributed networked CCTV cabinet/rack complete with ethernet switch (CISCO/Allied telesis/Pheonix contact/ MOXA /Advantech /Dahua/ Hikvision), fan, cable
8
management, DC power supply with battery (where-ever required), fuses, cabling and termination accessories installed inside wall mounted (locally manufactured) rack with lockable door as follows:
- 1 No.x 2 fiber ports + 08 copper POE+ ports industrial ethernet switch with enhanced operating temperature of 65
a) 7 Nos 18,684 130,791
degree centigrade
- Wall/Pole mounted 19" outdoor sheet steel cabinet with lockable door including DC power supply with battery backup
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
(1) (2) (3) (4) (4) (6) (9) (10) (12) (13)
IDF EXT 03
- 1 No.x 4 fiber ports + 08 copper POE+ ports industrial ethernet switch with enhanced operating temperature of 65
b) 1 Nos 18,684 18,684
degree centigrade
- Wall/Pole mounted 19" outdoor sheet steel cabinet with lockable door including DC power supply with battery backup
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
IDF-AN
Ethernet Switch + Wall
c) Mounted Cabinet - 1 No.x 2 fiber ports + 12 copper POE+ ports (unmanaged) ethernet switch 1 Nos 18,684 18,684
- Wall mounted 19" indoor cabinet/rack with lockable door including DC power supply with battery backup
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
IDF-LH-01, IDF-LH-02
d) - 1 No.x 2 fiber ports + 12 copper POE+ ports (unmanaged) ethernet switch 2 Nos 18,684 37,369
- Wall mounted 19" indoor sheet steel cabinet with lockable door
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
IDF-FR
e) - 1 No.x 2 fiber ports + 12 copper POE+ ports (unmanaged) ethernet switch 1 Nos 18,684 18,684
- Wall mounted 19" indoor sheet steel cabinet with lockable door
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
IDF-TH
f) - 1 No.x 2 fiber ports + 16 copper POE+ ports (unmanaged) ethernet switch 1 Nos 18,684 18,684
- Wall mounted 19" indoor sheet steel cabinet with lockable door
- Copper Cat 6 RJ 45 patch panel including patch cords, cable management and cable dressing
Fiber optic
Supply, installation & connecting up of outdoor rated 6 core (CORNING) fiber optic cable (single mode OS2, G657, cable is OF
9 Cabling & Conduiting 9/125µm) in already burried HDPE/RCC pipe or in already laid surface GI cable trunking or in concealed PVC /surface 3000 m 311 934,220 only
extra light GI conduit complete with mounting, laying and termination accessories installation
rate quoted
Supply installation and connecting up of client PC (HP/DELL) including management software for CCTV monitoring of
10 CCTV Control PC all cameras with licensed latest edition of Windows 10, dual graphic card, keyboard, mouse, 28" LED Monitor and 1 lot 24,913 24,913
HDMI cables
Supply, installation & connecting up of 50" 4K UHD LED screen (SAMSUNG/LG) including HDMI cables, wall mounts,
11 LED Monitoring Screen 3 Nos 24,913 74,738
all accessories, cabling upto PC(s) etc.
(1) (2) (3) (4) (4) (6) (9) (10) (12) (13)
Testing &
12 Testing & commissioning of complete CCTV system 1 lot 560,532 560,532
Commissioning
Note:
1. All controllers shall be mounted above false ceiling on nearby columns at accessible area with proper fixing & mounting arrangements.
2. Each controller shall be tagged with room/area name and room number.
3. This BOQ is to be read in conjunction with layouts, schematics & detail drawings.
4. The specified software (against BOQ item # 4) must be compatible to get installed in PC of client's security manager.
Supply, installation & connecting up of IP based access control system complete with all mounting and termination
1
accessories, backboxes, hardware, software licenses, comprising of:
ZK TECO
No touch Exit No touch exit keypad & built-in alarm
c)
Keypad buzzer with face plate
3 Nos 1,258 3,774 ( TELB101-R
or EQ.)
ZK TECO
Emergency Manual emergency break glass station
e)
Break Glass (door release)
3 Nos 1,258 3,774 ( ZKABK900
A-R or EQ.)
Key over-ride
f)
switch
Manual Key over-ride switch 3 Nos 1,258 3,774 ZK TECO