VRV
CO
Prices and technical information for VRV products
Reduced CO2 equivalent
NEW &
Table of contents
UNIQUE VRV 5 5 RQCEQ-P3 VRV III-Q heat recovery 33
2
Highlights
p. 11-12 NEW Decarbonisation of buildings made easy:
launching VRV 5 Heat Pumps
RXYA-A / RXYSA-AY1
p. 36 NEW Expansion valve kit and control box for easy connection
between DX outdoor unit and air handling unit
AHU connection
VRV indoor units
Air curtains
Model Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28
Hydrobox
Remarks
Cooling Capacity 22,4 28,0 33,5 36,4 40,0 45,0 50,4 56,0 61,5 67,4 73,5 78,5
Heating Capacity 25,0 31,5 37,5 41,0 45,0 50,0 56,5 63,0 69,0 75,0 82,5 87,5
› Reduced CO2 equivalent thanks to
the use of lower GWP refrigerant R-32
›
heat recovery
VRV 5 lifecycle
NEW
NEW
heat › ‚Free‘ heating through heat recovery REYA-A
recovery › Tackle small room applications
thanks to Shîrudo Technology
› The perfect personal comfort thanks
to simultaneous cooling and heating
NEW
NEW
VRV 5 Top sustainability over the entire
lifecycle
RXYA-A
heat
pump › Tackle any room thanks to Shîrudo
Technology
heat pump
Air-cooled
NEW
NEW
VRV 5 RXYSA-
lifecycle connection
S-series
› Unique low -height single fan range AV1/AY1 ratio limit:
NEW
NEW
NEW
- 10 dB(A)!
Fully optimized and tested in Daikin Factory Fast & easy installation & servicing
4
VRV 5 indoor units
FXFA-A
Round flow cassette
Type SB.FXFA20A-1 SB.FXFA25A-1 SB.FXFA32A-1 SB.FXFA40A-1 SB.FXFA50A-1 SB.FXFA63A-1 SB.FXFA80A-1 SB.FXFA100A-1 SB.FXFA125A-1
Main unit FXFA20A FXFA25A FXFA32A FXFA40A FXFA50A FXFA63A FXFA80A FXFA100A FXFA125A
Decoration panel BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Heating capacity kW 2,5 3,2 4,0 5,0 6,3 8,0 10,0 12,5 16,0
Price – Main unit Lei 6.998,- 7.230,- 7.673,- 8.420,- 8.872,- 9.182,- 11.573,- 12.140,- 12.733,-
Price – Decoration panel Lei 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,-
Set Price Lei 8.733,- 8.965,- 9.408,- 10.155,- 10.607,- 10.917,- 13.308,- 13.875,- 14.468,-
Note: Standard panel BYCQ140E must be removed from the order when ordering a different panel.
Standard Accessories
Drain pump (850mm delivery height from level of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
Infra-red wireless remote controller in white/ black for non-designer panel combinations - Note: not compatible with Presence &
BRC7FA532F(B)* 1.185,-
Floor sensors and no individual flap control
Infra-red wireless remote controller in white/ black for designer panel combination - Note: not compatible with Presence & Floor
BRC7FB532F(B)* 1.200,-
sensors and no individual flap control
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRYQ140B Presence & Floor sensors for BYCQ140E, BYCQ140EGF, BYCQ140EW 914,-
BRYQ140BB Presence & Floor sensors for BYCQ140EB, BYCQ140EGFB 914,-
BRYQ140C Presence & Floor sensors for BYCQ140EP 914,-
BRYQ140CB Presence & Floor sensors for BYCQ140EPB 951,-
Wi-Fi adaptor for smartphones
BRP069C51 633,-
(Only possible in combination with wired or wireless remote control (e.g. BRC1H52, BRC7F)
ERP01A51 (1) relay PCB 567,-
KRP1BC101 Installation box for adaptor PCB 401,-
NEW BAF552AA160 High efficiency filter; compatible for BYCQ140E/EW/EB panel 312,-
NEW BAEF125AWB UV Streamer Kit; compatible with BYQE140E/EW panel 3.681,-
* Only possible in combination with remote control ·BRC1H52W/S/K· For other control accessories and adaptor cards, please see the Accessories overview and combination table on page 55
FXZA-A
Fully flat cassette
Unique design in the market that integrates fully flat into the ceiling
Note: Standard panel BYFQ60C4W must be removed from the order when ordering a different panel.
Standard Accessories
Drain pump (750 mm delivery height from level of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
BRC7F530W* Infra-red wireless remote controller for BYFQ60C4W - Note: no individual flap control possible 1.191,-
BRC7F530S* Infra-red wireless remote controller for BYFQ60C4S - Note: no individual flap control possible 1.191,-
BRC7EB530W* Infra-red wireless remote controller for BYFQ60B3W1 1.356,-
BRC1H52W/S/K (2) Premium wired remote controller with white/sliver/black color 1.152,-
BRYQ60A3W Presence & Floor sensors for BYFQ60C4W 813,-
BRYQ60A3S Presence & Floor sensors for BYFQ60C4S 843,-
Wi-Fi adaptor for smartphones
BRP069C51 633,-
(Only possible in combination with wired or wireless remote control (e.g. BRC1H52, BRC7F)
ERP01A50 (3) relay PCB 521,-
KRP1BC101 Installation box for adaptor PCB 401,-
* Only possible in combination with remote control ·BRC1H52W/S/K. For other control accessories and adaptor cards, please see the Accessories overview and combination table on page 55
(1) For the connection of panel BYFQ60B3W1 with R-32 units it is necessary to use option EKRS23
(2) The independently-controllable-flaps function is not available.
(3) Requires installation box for adaptor PCB KRP1BC101
6
VRV 5 indoor units
FXAA-A
Wall mounted unit
Standard Accessories
Suction air filter
Optional Accessories
Control Price Lei
BRC7EA630* Infra red wireless remote controller 1.137,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
Wi-Fi adaptor for smartphones
BRP069C51 633,-
(Only possible in combination with wired or wireless control (e.g. BRC1H, BRC7E)
ERP01A51 (1) relay PCB 567,-
KRP4A93 Installation box for adaptor PCB 886,-
K-KDU572KVE Drain pump kit 3.727,-
(1) Requires installation box for adaptor PCB KRP4A93
* Only possible in combination with remote control ·BRC1H52W/S/K·
For other control accessories and adaptor cards, please see the Accessories overview and combination table on page 55
FXDA-A
Slim concealed ceiling unit
Standard Accessories
Drain pump (600 mm delivery height from top of unit)
Suction air filter
Optional Accessories
Control Price Lei
BRC4C65* Infra-red wireless remote controller with external receiver 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BAE20A62 Auto cleaning filter for FXDA15-32A 2.773,-
BAE20A82 Auto cleaning filter for FXDA40-50A 2.935,-
BAE20A102 Auto cleaning filter for FXDA63A 3.100,-
BAE20A62/82/102 Reducer to allow the usage of variable vacuum cleaners. Compatible with all three auto cleaning option kits. 2.773,-
Wi-Fi adaptor for smartphones
BRP069C51 633,-
(Only possible in combination with wired or wireless remote control (e.g. BRC1H52, BRC4C65)
ERP01A51 (1) relay PCB 567,-
KRP1BC101 Installation box for adaptor PCB 401,-
* Only possible in combination with remote control ·BRC1H52W/S/K·
(1) Requires installation box for adaptor PCB KRP1BC101
For other control accessories and adaptor cards, please see the Accessories overview and combination table on page 55
VRV Pricelist 2024-20257
VRV 5 indoor units
FXSA-A
Concealed ceiling unit with medium ESP
8
VRV 5 indoor units
FXMA-A
Concealed ceiling unit with high ESP
Indoor Unit FXMA 50A 63A 80A 100A 125A 200A 250A
Cooling capacity Total capacity At high fan speed kW 5,6 7,1 9,0 11,2 14,0 22,4 28,0
Heating capacity Total capacity At high fan speed kW 6,3 8,0 10,0 12,5 16,0 25,0 31,5
Fan External static Factory set / High Pa
100/200 150/250 150/250
pressure - 50Hz
Price Lei 8.492,- 8.672,- 10.977,- 11.364,- 11.604,- 18.589,- 19.064,-
Contains fluorinated greenhouse gases. *Note: The techical data is preliminary
Standard Accessories
Drain pump (625 mm delivery height from drain outlet) -optional for 200-250 models
Optional Accessories
Control Price Lei
BRC4C65* Wireless remote control 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
ERP01A50 Relay PCB 521,-
BRP069C51 Wi-Fi adaptor for smartphones (Only possible with wired or wireless remote control (eg. BRC1H52, BRC4C65) 633,-
BYBS71D decoration panel for FXMА50-80A on request
BYBS125D decoration panel for FXMА100-125A on request
KDAJ25K71 Air discharge adaptor for round ducts for FXMA50-80A 1.862,-
KDAJ25K140 Air discharge adaptor for round ducts for FXMA100-125 2.870,-
BAFL502A250 long life replacement filter for FXMA200/250A 1.427,-
BAFM503A250 High efficiency filter 65% for FXMA200/250A 2.749,-
BAFH504A250 High efficiency filter 90% for FXMA200/250A 2.890,-
BDD500B250 Filter chamber for FXMA200/250A 1.597,-
BDU510B250VM optional drain pump kit for FXMA200/250A 4.753,-
* Only possible in combination with remote control ·BRC1H52W/S/K·
For other control accessories and adaptor cards, please see the Accessories overview and combination table on page 55
FXHA-A
Ceiling suspended unit
For wide rooms with no false ceilings nor free floor space
FXUA-A
4-way blow ceiling suspended unit
Unique Daikin unit for high rooms with no false ceilings nor
free floor space
FXKA-A
1-way blow unit for corner installation Coming
Soon
Ceiling mounted corner cassette
10
VRV 5 outdoor units
RXYSA-AV1/AY1
VRV 5 S-series
Outdoor unit RXYSA4AV1 RXYSA5AV1 RXYSA6AV1 RXYSA4AY1 RXYSA5AY1 RXYSA6AY1 RXYSA8A RXYSA10A RXYSA12A
Capacity range HP 4 5 6 4 5 6 8 10 12
Cooling capacity Prated,c kW 12,1 14,0 15,5 12,1 14,0 15,5 22,4 28,0 33,5
Prated,h kW 12,1 14 15,5 12,1 14 15,5 22,4 28,0 33,5
Heating capacity
Max. 6°CWB kW 14,2 16,0 18,0 14,2 16,0 18,0 25,0 31,5 37,5
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415 3N~/50-60/380-415
Price Lei 24.807,- 28.085,- 30.048,- 24.807,- 28.085,- 30.048,- 37.392,- 43.819,- 53.166,-
Optional Accessories
Price Lei
KHRQ22M29H Refnet header 1.446,-
KHRQ22M20TA Refnet joint 551,-
KRC19-26 (1, 2 ) Cool/heat selector (switch) 391,-
KJB111A Cool/heat selector (fixing box) 191,-
EKPCCAB4 VRV configurator 1.561,-
EKBPH250D Bottom plate heater 1.229,-
Notes:
1. Cool/Heat selector PCB is standard in unit
2. To mount option KRC19-26·, option ·KJB111A· is required.
REYA-A
VRV 5 heat recovery
RXYA-A VRV 5
VRV 5 Heat Pump
RXYA8-12A
Widest R-32
VRV range in
the market
CO
More details and final information Lower CO2 equivalents 5 low sound steps
can be found by scanning or
clicking the QR codes. RXYA-A
Outdoor Unit RXYA 8A 10A 12A 14A 16A 18A 20A
Capacity range HP 8 10 12 14 16 18 20
Cooling capacity Prated,c kW 22,4 28,0 33,5 40,0 45,0 50,4 56,0
Heating capacity Prated,h kW 22,4 28,0 33,5 40,0 45,0 50,4 56,0
Max. 6°CWB kW 25,0 31,5 37,5 45,0 50,0 56,5 63,0
Power supply Phase/Frequency/Voltage Hz/V 3N~/50/380-415
Price Lei 59.175,- 64.729,- 77.678,- 90.636,- 103.857,- 123.911,- 136.308,-
12
New SV-A
SV-A
Optional Shut off valve box (SV) for VRV 5 Heat Pump
Combination table
RXYSA4-5-6AV1/AY1 RXYSA8-10-12AY1 RXYA-A
SV1A25A -
SV6A14A -
SV8A14A -
FXFQ-B
Round flow Cassette
Type SB.FXFQ20B-1 SB.FXFQ25B-1 SB.FXFQ32B-1 SB.FXFQ40B-1 SB.FXFQ50B-1 SB.FXFQ63B-1 SB.FXFQ80B-1 SB.FXFQ100B-1 SB.FXFQ125B-1
Main unit FXFQ20B FXFQ25B FXFQ32B FXFQ40B FXFQ50B FXFQ63B FXFQ80B FXFQ100B FXFQ125B
Decoration panel BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E BYCQ140E
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Heating capacity kW 2,5 3,2 4,0 5,0 6,3 8,0 10,0 12,5 16,0
Price – Main unit Lei 6.209,- 6.413,- 6.807,- 7.468,- 7.871,- 8.144,- 10.266,- 10.767,- 11.291,-
Price – Decoration panel Lei 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,- 1.735,-
Set Price Lei 7.944,- 8.148,- 8.542,- 9.203,- 9.606,- 9.879,- 12.001,- 12.502,- 13.026,-
Note: Standard panel BYCQ140E must be removed from the order when ordering a different panel.
Standard Accessories
Drain pump (850mm delivery height from level of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
Infra-red wireless remote controller for non-designer panel combinations - Note: not compatible with Presence & Floor sensors
BRC7FA532F 1.185,-
and no individual flap control
Infra-red wireless remote controller in black for non-designer panel combinations - Note: not compatible with Presence & Floor
BRC7FA532FB 1.185,-
sensors and no individual flap control
Infra-red wireless remote controller for the white designer panel combination - Note: not compatible with Presence & Floor
BRC7FB532F 1.200,-
sensors and no individual flap control
Infra-red wireless remote controller for the black designer panel combination - Note: not compatible with Presence & Floor
BRC7FB532FB 1.200,-
sensors and no individual flap control
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRYQ140B Presence & Floor sensors for BYCQ140E, BYCQ140EGF, BYCQ140EW 914,-
BRYQ140BB Presence & Floor sensors for BYCQ140EB, BYCQ140EGFB 914,-
BRYQ140C Presence & Floor sensors for BYCQ140EP 914,-
BRYQ140CB Presence & Floor sensors for BYCQ140EPB 951,-
NEW BAF552AA160 High efficiency filter; compatible for BYCQ140E/EW/EB panel 312,-
NEW BAEF125AWB UV Streamer Kit; compatible with BYQE140E/EW panel 3.681,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
BYCQ140EB Standard decoration panel in black (RAL 9005) 1.866,-
BYCQ140EGF Auto cleaning decoration panel in white (RAL 9010) with finer mesh filter - Must be combined with the BRC1H*.
NOTE: The following options cannot be used together with the Self-cleaning Decoration Panel:
- BRC7FA532F Infra-red wireless remote controller
- EKRP1C11 Wiring adaptor (use KRP1C12 instead)
- KRP1H98 Installation box for adaptors (use KRP1J98 instead) 3.352,-
- Fresh Air Intake Kit
- KRP4A53 Wiring adaptor for external monitoring/control
- KDBHQ55B140 Sealing kit for 3-directional or 2-directional air discharge
BYCQ140EGFB Black Auto cleaning decoration panel (RAL 9005) with finer mesh filter. Not suitable for high humid or greasy environments. 3.485,-
BYCQ140EW Full-white (RAL9010) Decoration panel (including white louvers). 1.956,-
BYCQ140EP New Designer panel in white (RAL 9010) 1.909,-
BYCQ140EPB New Designer panel in black (RAL 9005) 2.177,-
SB.KDDP55 Fresh air intake kit for max 20% fresh air (consisting of two parts) 3.343,-
KDBHQ56B140 Sealing kit for 3-directional or 2-directional air discharge 807,-
KAF5511D160 Replacement long life filter 710,-
FXZQ-A
Fully flat Cassette
Note: Standard panel BYFQ60CW must be removed from the order when ordering a different panel.
Standard Accessories
Drain pump (750 mm delivery height from level of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
BRC7F530W Infra-red wireless remote controller for BYFQ60CW - Note: no individual flap control possible 1.191,-
BRC7F530S Infra-red wireless remote controller for BYFQ60CS - Note: no individual flap control possible 1.191,-
BRC7EB530W Infra-red wireless remote controller for BYFQ60B3 1.356,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRYQ60AW Presence & Floor sensors for BYFQ60CW - Note: must be combined with BRC1H52W/S/K 914,-
BRYQ60AS Presence & Floor sensors for BYFQ60CS - Note: must be combined with BRC1H52W/S/K 914,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
BYFQ60CW Fully Flat Decoration panel - full white design - Included in above calculated Set price 1.666,-
BYFQ60CS Fully Flat Decoration panel - silver/white design 1.777,-
BYFQ60B3 Legacy design Euro-raster decoration panel (outlook as previous generation unit) - Note: does not have individual flap control 1.648,-
BDBHQ44C60 Sealing kit for 3-directional or 2-direction air discharge for BYFQ* panels 683,-
KDBQ44B60 Panel spacer for reduced installation space - Only possible for use with Legacy design panel BYFQ60B3W1 3.132,-
KDDQ44XA60 Fresh air intake kit (connecting flange for ait duct) 1.032,-
KAF441C60 Replacement long life filter 691,-
16
Standard VRV IV indoor units
FXCQ-A
VRV ceiling mounted cassette (2-way blow)
Type SB. FXCQ20A.WP SB. FXCQ25A.WP SB. FXCQ32A.WP SB.FXCQ40A.WP SB. FXCQ50A.WP SB. FXCQ63A.WP SB. FXCQ80A.WP SB. FXCQ125A.WP
Main unit FXCQ20A FXCQ25A FXCQ32A FXCQ40A FXCQ50A FXCQ63A FXCQ80A FXCQ125A
Decoration panel BYBCQ40H BYBCQ40H BYBCQ40H BYBCQ40H BYBCQ63H BYBCQ63H BYBCQ125H BYBCQ125H
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 9,0 14,0
Heating capacity kW 2,5 3,2 4,0 5,0 6,3 8,0 10,0 16,0
Price – Main unit Lei 6.074,- 6.139,- 6.334,- 6.856,- 7.094,- 7.187,- 9.605,- 11.716,-
Price – Decoration panel Lei 4.090,- 4.090,- 4.090,- 4.090,- 4.695,- 4.695,- 5.342,- 5.342,-
Set Price Lei 10.164,- 10.229,- 10.424,- 10.946,- 11.789,- 11.882,- 14.947,- 17.058,-
Standard Accessories
Drain pump (600 mm delivery height from level of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
BRC7C52 Infra-red wireless remote controller - Note: no individual flap control 1.556,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
KAF531C50 Replacement long life filter for FXCQ20-40A on request
KAF531C80 Replacement long life filter for FXCQ50-63A on request
KAF531C160 Replacement long life filter for FXCQ80-125A on request
For other control accessories and adaptor cards, please the Accessories overview and combination table on pages 56-57.
FXKQ-MA
VRV ceiling mounted cassette (1-way blow)
Uniquely slim design means this unit needs very little false ceiling
space
Standard Accessories
Drain pump (500 mm delivery height from of false ceiling)
Suction air filter
Optional Accessories
Control Price Lei
BRC4C61 Infra-red wireless remote controller 2.370,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
New model with new outlook expected in 2024! Change of Name to FXKQ-A and new classes (20 class and 50 class coming in 2024)
FXUQ-A
VRV 4-way blow ceiling suspended unit
Standard Accessories
Drain pump (350 mm delivery height from top of unit)
Suction air filter
Optional Accessories
Control Price Lei
BRC7C58 Infra-red wireless remote controller 1.556,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
KDBHP49B140 Sealing kit for an air outlet 1.386,-
KDBTP49B140 Decoration panel for a sealed air outlet 2.160,-
KAFP551K160 Replacement long life filter 614,-
FXHQ-A
VRV Ceiling suspended unit
In a new fresh-white design with a flap that fully closes when the
unit is off
Standard Accessories
Suction air filter
Optional Accessories
Control Price Lei
BRC7GA53-9 Infra-red wireless remote controller 1.641,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
KDU50P60 Drain pump kit for FXHQ32A 5.617,-
KDU50P140 Drain pump kit for FXHQ63~100A 7.742,-
KAF501B56 Replacement long life filter for FXHQ32A 1.043,-
KAF501B80 Replacement long life filter for FXHQ63A 1.043,-
KAF501B80 Replacement long life filter for FXHQ71-100A 1.043,-
18
Standard VRV IV indoor units
FXAQ-A
VRV Wall mounted unit
Standard Accessories
Suction air filter
Optional Accessories
Control Price Lei
BRC7EA628 Infra-red wireless remote controller 1.330,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
K-KDU572EVE External drain pump kit (1000 mm delivery height) 2.668,-
FXDQ-A3
VRV Concealed ceiling unit (Slim)
With it’s 20 cm, this unit is one of the slimmest in the market,
requiring just very little false ceiling space. And now it boasts an
energy saving inverter fan motor!
Now with the option of self cleaning filter; saving energy up to 20%!
Standard Accessories
Drain pump (550 mm delivery height from top of unit)
Suction air filter
Optional Accessories
Control Price Lei
BRC4C65 Infra-red wireless remote controller with external receiver 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRC2E52C Simplified wired remote control with operation mode button 886,-
BRC3E52C Simplified wired remote control without operation mode button. 886,-
BAE20A62 Auto cleaning filter for FXDQ15-32A3 2.773,-
BAE20A82 Auto cleaning filter for FXDQ40-50A3 2.935,-
BAE20A102 Auto cleaning filter for FXDQ63A3 3.100,-
BAE20A62/82/102 Reducer to allow the usage of variable vacuum cleaners. Compatible with all three auto cleaning option kits. 2.773,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
FXMQ-A
VRV Concealed ceiling unit (Large)
Optional Accessories
Control Price Lei
BRC4C65 Infra-red wireless remote controller with external receiver 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRC2E52C Simplified wired remote control with operation mode button 886,-
BRC3E52C Simplified wired remote control without operation mode button. 886,-
BAFL502A250 Long life replacement filter 1.427,-
BDD500B250 Filter chamber 1.597,-
BAFM503A250 High efficiency filter 65% 2.749,-
BAFH504A250 High efficiency filter 90% 2.890,-
BDU510B250VM Optional drain pump kit 4.753,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
20
Standard VRV IV indoor units
FXSQ-A
VRV Concealed ceiling unit (Standard)
With inverter fan motors, these units offer more than 9 different ESP
settings or an automatic air-flow adjustment function for precise
tuning to the real installation. Improved height, sound, ESP and
efficiency values! Lowest built-in height in the market!
FXMQ-P7
VRV Concealed ceiling unit (High ESP)
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other for FXSQ-A Price Lei
KDAP25A36 Air discharge adaptor for round duct - for units 15-32 771,-
KDAP25A56 Air discharge adaptor for round duct - for FXSQ40~50A 905,-
KDAP25A71 Air discharge adaptor for round duct - for FXSQ63~80A 1.875,-
KDAP25A140 Air discharge adaptor for round duct - for FXSQ100~125A 2.894,-
The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately
adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat
located in the main room and individual thermostats for each of the zones.
2
AZE(Z/R)6DAIST07XS2 • • • • 8.597,- on request
AZE(Z/R)6DAIST07S2
300 x 930 x 454
• • 8.597,- on request
3
AZE(Z/R)6DAIST07XS3 • • • • 9.257,- on request
AZE(Z/R)6DAIST07S3 • • 9.257,- on request
4
AZE(Z/R)6DAIST07S4
300 x 1.140 x 454
• • 9.871,- on request
AZE(Z/R)6DAIST07M4 • • 9.871,- on request
Standard plenum AZE(Z/R)6DAIST07M5 • • 11.038,- on request
5 300 x 1.425 x 454 200
AZE(Z/R)6DAIST07L5 • • 11.038,- on request
6
AZE(Z/R)6DAIST07M6
300 x 1.638 x 454
• • 12.627,- on request
AZE(Z/R)6DAIST07L6 • • 12.627,- on request
7
AZE(Z/R)6DAIST07L7 • • 13.339,- on request
AZE(Z/R)6DAIST07XL7
515 x 1.425 x 454
• 13.339,- on request
8
AZE(Z/R)6DAIST07L8 • • 14.060,- on request
AZE(Z/R)6DAIST07XL8 • 14.060,- on request
2
AZEZ6DAIBS07XS2 • • • • 8.586,- -
AZEZ6DAIBS07S2 • • 8.587,- -
AZEZ6DAIBS07XS3 250 x 930 x 454 • • • • 9.248,- -
3 AZEZ6DAIBS07S3 • • 9.249,- -
AZEZ6DAIBS07M3 • • 9.249,- -
AZEZ6DAIBS07S4 • • 9.875,- -
Medium plenum 4 AZEZ6DAIBS07M4 250 x 1.140 x 454 • • 9.879,- -
AZEZ6DAIBS07L4 200 • • 9.879,- -
AZEZ6DAIBS07S5 • • 11.053,- -
5
AZEZ6DAIBS07M5
250 x 1.425 x 454
• • 11.053,- -
AZEZ6DAIBS07L5 • • 11.053,- -
AZEZ6DAIBS07XL5 • 11.056,- -
AZEZ6DAIBS07M6 • • 12.618,- -
6 AZEZ6DAIBS07L6 250 x 1.638 x 454 • • 12.618,- -
AZEZ6DAIBS07XL6 • 12.621,- -
Slim plenum 2 AZE(Z/R)6DAISL01S2
210 x 720 x 444
• • • • 8.924,- on request
3 AZE(Z/R)6DAISL01S3
150
• • • • 9.597,- on request
4 AZE(Z/R)6DAISL01M4 210 x 930 x 444 • • 10.246,- on request
5 AZE(Z/R)6DAISL01L5 210 x 1.140 x 444 • 10.937,- on request
(1) Z models are reversible; R models are heating only
(2) Medium Ceiling Void reversible units can be blocked to heating only via AZX6MCS module
22
Standard VRV IV indoor units
Price Lei
BACnet gateway
Allows ON/OFF control of each zone
Control of temperature for each zone AZX6WSPBAC 1.788,-
Status indication of operation mode
One gateway needed per system
PREJ040015T 740,-
Insulated, galvanised steel
Diameter 250mm
Return air grilles and plenums
AZCEZDAPR07XS 808,-
Plenum for return air
To connect 1 up to 4 circular ducts to the Daikin concealed AZCEZDAPR07S 808,-
ceiling units AZCEZDAPR07M 910,-
Diameter 250mm AZCEZDAPR07L 1.167,-
Different sizes (XS, S, M, L, XL) to fit the indoor unit
AZCEZDAPR07XL 1.325,-
FXLQ-P
VRV floor standing unit
Standard Accessories
Suction air filter
Optional Accessories
Control Price Lei
BRC4C65 Infra-red wireless remote controller with external receiver 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRC2E52C Simplified wired remote control with operation mode button 886,-
BRC3E52C Simplified wired remote control without operation mode button. 886,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
Other Price Lei
EKRDP25 Rear decoration panel - for units FXLQ20~25P 771,-
EKRDP40 Rear decoration panel - for units FXLQ32~40P 935,-
EKRDP63 Rear decoration panel - for units FXLQ50~63P 1.104,-
FXNQ-A
VRV concealed floor standing unit
Standard Accessories
Suction air filter
Optional Accessories
Control Price Lei
BRC4C65 Infra-red wireless remote controller with external receiver 604,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
BRC2E52C Simplified wired remote control with operation mode button 886,-
BRC3E52C Simplified wired remote control without operation mode button. 886,-
For other control accessories and adaptor cards, please see the Accessories overview and combination table on pages 56-57.
24
VRV Hydroboxes
HXY-A8
VRV IV low temperature reversible hydrobox
Heat or cool down water with the same VRV IV system that you use
for DX heating or cooling - ideal for floor-heating of high rooms or
rooms, where DX units are unsuitable (small restrooms, etc.)
IMPORTANT: Combinable only with RYYQ-U, RXYQ-U and REYQ-U systems
Standard Accessories
Remote controller with leaving water temperature contol
Hydraulic components (circulation pump, expansions vessel, safety valve, etc.)
Expansion valve for connection to the VRV system
Optional Accessories
Control Price Lei
EKHBDPC2 Optional drain pan (required for cooling operation) 915,-
EKRP1AHT Demand PCB - Required to be able to connect Room thermostat 800,-
EKRUAHTB Remote user interface - Same controller as supplied with hydrobox unit can be mounted parallel or in another location. 1.174,-
EKRTWA Wired Room thermostat - Requires Demand PCB EKRP1AHT 746,-
EKRTR Wireless Room thermostat - Requires Demand PCB EKRP1AHT 1.475,-
EKRTETS Remote sensor for Room thermostat - Requires Demand PCB EKRP1AHT 97,-
EKBUHA6V3 6kW external back-up heater, 1-phase (230V) power supply 3.450,-
EKBUHA6W1 6kW external back-up heater, 3-phase (400V) power supply 3.450,-
HXHD-A8
VRV IV heat recovery High temperature heating only
hydrobox
80°C hot water from energy recovered during cooling operation
with pure heat pump technology - no direct electrical heaters -
thanks to a unique R-410A-R-134a cascade refrigerant system.
IMPORTANT: Only combinable with REYQ-U systems
Standard Accessories
Remote controller for external installation
Hydraulic components (circulation pump, expansions vessel, safety valve, etc.)
R-134a factory charge – no field charge of R-134a is neccessary
Optional Accessories
Control Price Lei
EKRP1HBA Digital I/O PCB 781,-
EKRP1AHT Demand PCB - Required to be able to connect Room thermostat 800,-
EKRUAHTB Remote user interface - Same controller as supplied with Cascade unit can be mounted parallel or in another location. 1.174,-
EKRTWA Wired Room thermostat - Requires Demand PCB EKRP1AHT 746,-
EKRTR Wireless Room thermostat - Requires Demand PCB EKRP1AHT 1.475,-
EKRTETS Remote sensor for Room thermostat - Requires Demand PCB EKRP1AHT 97,-
RTD-W Modbus and advanced control adaptor for HT Hydrobox 2.363,-
Others
Sanitary water tanks of various sizes and configurations *
Solar connections and pump stations *
* for details and prices, refer to the Heating catalogue and price list, Altherma high temperatures sections. Heating discount policies apply for these accessories
Type for 3N~ 400V power supply RYYQ32U.OU RYYQ34U.OU RYYQ36U.OU RYYQ38U.OU RYYQ40U.OU RYYQ42U.OU
RYMQ8U RYMQ10U RYMQ10U
RYMQ16U RYMQ16U RYMQ16U
RYMQ10U RYMQ12U RYMQ16U
Modules and kits required RYMQ16U RYMQ18U RYMQ20U
RYMQ20U RYMQ18U RYMQ16U
BHFQ22P1007 BHFQ22P1007 BHFQ22P1007
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 90,0 95,4 97 102,4 111,9 118,0
Nominal heating capacity kW 100,0 106,5 113,0 119,5 125,5 131,5
Set Price Lei 208.594,- 228.652,- 241.042,- 262.045,- 268.153,- 274.270,-
Type for 3N~ 400V power supply RYYQ44U.OU RYYQ46U.OU RYYQ48U.OU RYYQ50U.OU RYYQ52U.OU RYYQ54U.OU
RYMQ12U RYMQ14U RYMQ16U RYMQ16U RYMQ16U RYMQ18U
RYMQ16U RYMQ16U RYMQ16U RYMQ16U RYMQ18U RYMQ18U
Modules and kits required
RYMQ16U RYMQ16U RYMQ16U RYMQ18U RYMQ18U RYMQ18U
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 123,5 130,0 135,0 140,4 145,8 151,2
Nominal heating capacity kW 137,5 145,0 150,0 156,5 163 169,5
Set Price Lei 287.219,- 300.177,- 313.394,- 333.452,- 353.510,- 373.568,-
Other combinations than the listed „Standard combinations“ above are allowed, including 16~20HP systems, but system piping limitations
are shorter (see appropriate Data Book). Systems over 54HP or with more than 3 modules are not allowed.
Optional Accessories
Price Lei
BHFQ22P1007 Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 886,-
BHFQ22P1517 Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 1.832,-
EKPCCAB4 VRV Configurator 1.561,-
BRP2A81 *1 A-B-C contact PCB for switching between cooling and heating from the outdoor unit 1.015,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
EKBPH012TA Optional bottom-plate heater tape kit PCB - for 8~12 HP units 3.573,-
EKBPH020TA Optional bottom-plate heater tape kit PCB - for 14~20 HP units 3.725,-
KRC19-26 *3 Mechanical cool/heat selector (Caution: BRP2A81 option is neccessary) 391,-
*1) KKSA26A560 Mounting plate for BRP2A81 - only neccessary when cool/heat selector PCB and heater tape are combined on 14~20 HP units 505,-
Mounting plate for DTA104A61 for installation inside 14~20 HP outdoor units. See pages 56-57 for DTA104* adaptor details
*2) KKSB26B1 416,-
and possibilities to install in indoor units.
*3) KJB111A Fixing box for mechanical cool/heat selector 191,-
BPMKS967A2 Branch provider for connection of 2 RA indoor units (for single module outdoors only) 4.311,-
BPMKS967A3 Branch provider for connection of 3 RA indoor units (for single module outdoors only) 4.602,-
26
Outdoor units
ErP 2021
COMPLIANT
Single-module systems
Type for 3N~ 400V power supply RXYQ8U RXYQ10U RXYQ12U RXYQ14U RXYQ16U RXYQ18U RXYQ20U
Nominal cooling capacity kW 22,4 28,0 33,5 40,0 45,0 50,0 52,0
Nominal heating capacity kW 25,0 31,5 37,5 45,0 50,0 56,5 63,0
Price Lei 56.357,- 61.647,- 73.979,- 86.320,- 98.911,- 118.010,- 129.817,-
Type for 3N~ 400V power supply RXYQ32U.OU RXYQ34U.OU RXYQ36U.OU RXYQ38U.OU RXYQ40U.OU RXYQ42U.OU
RXYQ8U RXYQ10U RXYQ10U
RXYQ16U RXYQ16U RXYQ16U
RXYQ10U RXYQ12U RXYQ16U
Modules and kits required RXYQ16U RXYQ18U RXYQ20U
RXYQ20U RXYQ18U RXYQ16U
BHFQ22P1007 BHFQ22P1007 BHFQ22P1007
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 90,0 95,4 97,0 102,4 111,9 118,0
Nominal heating capacity kW 100,0 106,5 113,0 119,5 125,5 131,5
Set Price Lei 198.708,- 217.807,- 229.614,- 249.653,- 255.468,- 261.301,-
Type for 3N~ 400V power supply RXYQ44U.OU RXYQ46U.OU RXYQ48U.OU RXYQ50U.OU RXYQ52U.OU RXYQ54U.OU
RXYQ12U RXYQ14U RXYQ16U RXYQ16U RXYQ16U RXYQ18U
RXYQ16U RXYQ16U RXYQ16U RXYQ16U RXYQ18U RXYQ18U
Modules and kits required
RXYQ16U RXYQ16U RXYQ16U RXYQ18U RXYQ18U RXYQ18U
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 123,5 130,0 135,0 140,4 145,8 151,2
Nominal heating capacity kW 137,5 145,0 150,0 156,5 163,0 169,5
Set Price Lei 273.633,- 285.974,- 298.565,- 317.664,- 336.763,- 355.862,-
Other combinations than the listed „Standard combinations“ above are allowed, including 16~20HP systems, but system piping limitations
are shorter (see appropriate Data Book). Systems over 54HP or with more than 3 modules are not allowed.
Optional Accessories
Price Lei
BHFQ22P1007 Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 886,-
BHFQ22P1517 Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 1.832,-
EKPCCAB4 VRV Configurator 1.561,-
BRP2A81 *1 A-B-C contact PCB for switching between cooling and heating from the outdoor unit 1.015,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
EKBPH012TA Optional bottom-plate heater tape kit PCB - for 8~12 HP units 3.573,-
EKBPH020TA Optional bottom-plate heater tape kit PCB - for 14~20 HP units 3.725,-
KRC19-26 *3 Mechanical cool/heat selector (Caution: BRP2A81 option is neccessary) 391,-
*1) KKSA26A560 Mounting plate for BRP2A81 - only neccessary when cool/heat selector PCB and heater tape are combined on 14~20 HP units 505,-
Mounting plate for DTA104A61 for installation inside 14~20 HP outdoor units. See pages 56-57 for DTA104* adaptor details
*2) KKSB26B1 416,-
and possibilities to install in indoor units.
*3) KJB111A Fixing box for mechanical cool/heat selector 191,-
DE.WINPROVRV6 Wind protection left & right sides for 8,10,12,14,16,18,20 HP models 10.698,-
DE.WINPROVRV7 Wind protection back side for 8,10,12 HP model 3.488,-
DE.WINPROVRV8 Wind protection back side for 14,16,18,20 HP model 3.772,-
DE.WINPROVRV9 Wind protection front side for 8,10,12 HP model 2.393,-
DE.WINPROVRV10 Wind protection front side for 14,16,18,20 HP model 2.356,-
BPMKS967A2 Branch provider for connection of 2 RA indoor units (for single module outdoors only) 4.311,-
BPMKS967A3 Branch provider for connection of 3 RA indoor units (for single module outdoors only) 4.602,-
Single-module systems
Type for 3N~ 400V power supply RXYLQ10T RXYLQ12T RXYLQ14T
Nominal cooling capacity kW 28,0 33,5 40,0
Nominal heating capacity kW 31,5 37,5 45,0
Price Lei 71.206,- 85.446,- 99.703,-
Type for 3N~ 400V power supply RXYLQ26T.OU RXYLQ28T.OU RXYLQ30T.OU RXYLQ32T.OU RXYLQ34T.OU
RXYLQ10T RXYLQ10T RXYLQ10T
RXYLQ12T RXYLQ14T
RXYLQ10T RXYLQ10T RXYLQ12T
Modules and kits required RXYLQ14T RXYLQ14T
RXYLQ10T RXYLQ12T RXYLQ12T
BHFQ22P1007 BHFQ22P1007
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 73,5 80,0 84,0 89,5 95,0
Nominal heating capacity kW 82,5 90,0 94,5 101,0 107,0
Set Price Lei 186.035,- 200.292,- 215.450,- 229.690,- 243.930,-
Type for 3N~ 400V power supply RXYLQ36T.OU RXYLQ38T.OU RXYLQ40T.OU RXYLQ42T.OU
RXYLQ12T RXYLQ12T RXYLQ12T RXYLQ14T
RXYLQ12T RXYLQ12T RXYLQ14T RXYLQ14T
Modules and kits required
RXYLQ12T RXYLQ14T RXYLQ14T RXYLQ14T
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 100,5 107,0 113,5 120,0
Nominal heating capacity kW 113,0 120,0 128 135,0
Set Price Lei 258.170,- 272.427,- 286.684,- 300.941,-
Other combinations than the listed „Standard combinations“ above are allowed, including 20HP systems, but system piping limitations are
shorter (see appropriate Data Book). Systems over 54HP or with more than 3 modules are not allowed.
Optional Accessories
Price Lei
BHFQ22P1007 Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 886,-
BHFQ22P1517 Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 1.832,-
EKPCCAB4 VRV Configurator 1.561,-
BRP2A81 A-B-C contact PCB for switching between cooling and heating from the outdoor unit 1.015,-
KRC19-26 *1 Mechanical cool/heat selector (Caution: BRP2A81 option is neccessary) 391,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
*1) KJB111A Fixing box for mechanical cool/heat selector 191,-
DE.WINPROVRV6 Wind protection left & right sides for 8,10,12,14 HP models 10.698,-
DE.WINPROVRV8 Wind protection back side for 8,10,12,14 HP model 3.772,-
DE.WINPROVRV10 Wind protection front side for 8,10,12,14 HP model 2.356,-
BPMKS967A2 Branch provider for connection of 2 RA indoor units (for single module outdoors only) 4.311,-
BPMKS967A3 Branch provider for connection of 3 RA indoor units (for single module outdoors only) 4.602,-
28
Outdoor units
ErP 2021
COMPLIANT
VRV IV S-series
Mini VRV Compact
RXYSCQ-T
The most compact VRV and lightweight single fan design saves
space and is easy to install. Incorporates VRV IV standards &
technologies such as Variable Refrigerant Temperature.
Available in single phase only.
Optional Accessories
Price Lei
DTA104A53/61/62 *1 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
BPMKS967A2 Branch Provider box for connecting up to 2 Split or SkyAir indoor units (VRV indoor units can not be used on entire system) 4.311,-
BPMKS967A3 Branch Provider box for connecting up to 3 Split or SkyAir indoor units (VRV indoor units can not be used on entire system) 4.602,-
*1) See pages 56-57 for details and exact adaptor type selection (for indoor unit installation, depend on indoor unit)
Mini VRV
RXYSQ-T
RXYSQ-T
Type for 1~230V power supply RXYSQ4TV9 RXYSQ5TV9 RXYSQ6TV9
Cooling capacity kW 12,1 14,0 15,5
Heating capacity kW 14,2 16,0 18,0
Price Lei 22.650,- 25.641,- 27.433,-
Type for 3N~400V power supply RXYSQ4TY9 RXYSQ5TY9 RXYSQ6TY9 RXYSQ8TY1 RXYSQ10TY1 RXYSQ12TY1
Cooling capacity kW 12,1 14,0 15,5 22,4 28,0 33,5
Heating capacity kW 14,2 16,0 18,0 25,0 31,5 37,5
Price Lei 22.650,- 25.641,- 27.433,- 37.392,- 43.819,- 53.166,-
Optional Accessories
Price Lei
EBRP2B Cool/heat selector PCB only for RXYSQ-TV9 models 623,-
KRC19-26 *1 Mechanical cool/heat selector only for RXYSQ4-5-6T models 391,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
A-B-C contact PCB for switching between cooling and heating from the outdoor unit for RXYSQ8-12TY (non official option, no
BRP2A81 1.015,-
place for installation in outdoor unit)
BPMKS967A2 Branch Provider box for connecting up to 2 Split or SkyAir indoor units (VRV indoor units can not be used on entire system) 4.311,-
BPMKS967A3 Branch Provider box for connecting up to 3 Split or SkyAir indoor units (VRV indoor units can not be used on entire system) 4.602,-
*1) KJB111A Fixing box for mechanical cool/heat selector only for RXYSQ4-5-6T models 191,-
EKCHSC Cool/heat selector cable (required to connect KRC19-26) for RXYSQ4-6TY9 173,-
*2) See pages 56-57 for details and exact adaptor type selection (for indoor unit installation, depend on indoor unit)
Compressor unit
Optional Accessories
Price Lei
EKPCCAB4 VRV Configurator 1.561,-
KRC19-26 *1 Mechanical cool/heat selector (Caution: BRP2A81 option is neccessary for RKXYQ8) 391,-
BRP2A81 Cool/ heat selector PCB only for RKXYQ8 1.015,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
*1) KJB111A Fixing box for mechanical cool/heat selector 191,-
EKDPH1RDX Drain pan heater 672,-
*2) See pages 56-57 for details and exact adaptor type selection (for indoor unit installation, depend on indoor unit)
30
Outdoor units
ErP 2021
COMPLIANT
Single-module systems
Type for 3N~ 400V power supply REYQ8U REYQ10U REYQ12U REYQ14U REYQ16U REYQ18U REYQ20U
Nominal cooling capacity kW 22,4 28,0 33,5 40,0 45,0 50,4 56,0
Nominal heating capacity kW 25,0 31,5 37,5 45,0 50,0 56,5 63,0
Price Lei 60.977,- 66.106,- 79.307,- 92.532,- 105.716,- 126.437,- 142.069,-
Single-module systems are not capable of continuous heating during defrost.
Low-capacity standard multi-module combinations
Type for 3N~ 400V power supply M-REYQ10U.OU M-REYQ13T.OU M-REYQ16U.OU M-REYQ18U.OU M-REYQ20U.OU
REMQ5U REMQ5U REYQ8U REYQ8U REYQ8U
Modules and kits required REMQ5U REYQ8U REYQ8U REYQ10U REYQ12U
BHFQ23P907A BHFQ23P907A BHFQ23P907A BHFQ23P907A BHFQ23P907A
Nominal cooling capacity kW 28,0 36,4 44,8 50,4 55,9
Nominal heating capacity kW 32,0 41,0 50,0 56,5 62,5
Set Price Lei 87.586,- 105.594,- 123.602,- 128.731,- 141.932,-
Type for 3N~ 400V power supply REYQ32U.OU REYQ34U.OU REYQ36U.OU REYQ38U.OU REYQ40U.OU REYQ42U.OU
REYQ8U REYQ10U REYQ10U
REYQ16U REYQ16U REYQ16U
REYQ12U REYQ12U REYQ16U
Modules and kits required REYQ16U REYQ18U REYQ20U
REYQ18U REYQ18U REYQ16U
BHFQ23P907A BHFQ23P907A BHFQ23P907A
BHFQ23P1357 BHFQ23P1357 BHFQ23P1357
Nominal cooling capacity kW 90,0 95,4 97 106,3 111,9 118,0
Nominal heating capacity kW 100,0 106,5 113,0 119 125,5 131,5
Set Price Lei 213.080,- 233.801,- 249.433,- 270.261,- 275.390,- 281.078,-
Type for 3N~ 400V power supply REYQ44U.OU REYQ46U.OU REYQ48U.OU REYQ50U.OU REYQ52U.OU REYQ54U.OU
REYQ12U REYQ14U REYQ16U REYQ16U REYQ16U REYQ18U
REYQ16U REYQ16U REYQ16U REYQ16U REYQ18U REYQ18U
Modules and kits required
REYQ16U REYQ16U REYQ16U REYQ18U REYQ18U REYQ18U
BHFQ23P1357 BHFQ23P1357 BHFQ23P1357 BHFQ23P1357 BHFQ23P1357 BHFQ23P1357
Nominal cooling capacity kW 123,5 130,0 135,0 140,4 145,8 151,2
Nominal heating capacity kW 137,5 145,0 150,0 156,5 163 169,5
Set Price Lei 294.279,- 307.504,- 320.688,- 341.409,- 362.130,- 382.851,-
Other combinations than the listed „standard combinations“ above are allowed, but system piping limitations are shorter (see appropriate
Data Book)
Systems over 54HP or with more than 3 modules are not allowed.
Optional Accessories
Price Lei
BHFQ23P907A Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 1.648,-
BHFQ23P1357 Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 3.540,-
EKPCCAB4 VRV Configurator 1.561,-
DTA104A53/61/62 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
EKBPH012TA Optional bottom-plate heater - for 8~12 HP units 3.573,-
EKBPH020TA Optional bottom-plate heater - for 14~20 HP units 3.725,-
DE.WINPROVRV6 Wind protection left & right sides for 8,10,12,14,16,18,20 HP models 10.698,-
DE.WINPROVRV7 Wind protection back side for 8,10,12 HP model 3.488,-
DE.WINPROVRV8 Wind protection back side for 14,16,18,20 HP model 3.772,-
DE.WINPROVRV9 Wind protection front side for 8,10,12 HP model 2.393,-
DE.WINPROVRV10 Wind protection front side for 14,16,18,20 HP model 2.356,-
Type for 3N~ 400V power supply RXYQQ32U.OU RXYQQ34U.OU RXYQQ36U.OU RXYQQ38U.OU RXYQQ40U.OU RXYQQ42U.OU
RXYQQ8U RXYQQ10U RXYQQ10U
RXYQQ16U RXYQQ16U RXYQQ16U
RXYQQ10U RXYQQ12U RXYQQ16U
Modules and kits required RXYQQ16U RXYQQ18U RXYQQ20U
RXYQQ20U RXYQQ18U RXYQQ16U
BHFQ22P1007 BHFQ22P1007 BHFQ22P1007
BHFQ22P1517 BHFQ22P1517 BHFQ22P1517
Nominal cooling capacity kW 90,0 95,4 97 111,9 118 118,0
Nominal heating capacity kW 100,0 106,5 113,0 125,5 131,5 131,5
Set Price Lei 232.332,- 257.791,- 264.852,- 288.143,- 301.700,- 305.408,-
Other combinations than the listed „Standard combination“ above are NOT allowed.
Optional Accessories
Price Lei
BHFQ22P1007 Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 886,-
BHFQ22P1517 Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 1.832,-
EKPCCAB4 VRV Configurator 1.561,-
BRP2A81 A-B-C contact PCB for switching between cooling and heating from the outdoor unit 1.015,-
KRC19-26 *1 Mechanical cool/heat selector (Caution: BRP2A81 option is neccessary) 391,-
DTA104A53/61/62 *2 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
*1) KJB111A Fixing box for mechanical cool/heat selector 191,-
*2) See pages 56-57 for details and exact adaptor type selection (for indoor unit installation, depend on indoor unit)
32
Outdoor units
ErP 2021
COMPLIANT
Multi-module systems
Type for 3N~ 400V power supply RQCEQ280P3.OU RQCEQ460P3.OU RQCEQ500P3.OU RQCEQ540P3.OU
Capacity class HP 10 16 18 20
RQEQ140P3 RQEQ140P3 RQEQ180P3
RQEQ140P3
RQEQ140P3 RQEQ180P3 RQEQ180P3
Modules and kits required RQEQ140P3
RQEQ180P3 RQEQ180P3 RQEQ180P3
BHFP26P36C
BHFP26P63C BHFP26P63C BHFP26P63C
Nominal cooling capacity kW 28,0 46,0 50,0 54,0
Nominal heating capacity kW 32,0 52,0 56,0 60,0
Set Price Lei 127.915,- 218.085,- 243.289,- 268.493,-
Optional Accessories
Price Lei
BHFP26P36C Multi-module connection kit for 2-module systems (obligatory for 2-module systems - included in above set prices) 1.869,-
BHFP26P63C Multi-module connection kit for 3-module systems (obligatory for 3-module systems - included in above set prices) 3.812,-
BHFP26P84C Multi-module connection kit for 4-module systems (obligatory for 4-module systems - included in above set prices) 5.074,-
BHGP26A1 Digital pressure gauge kit (only one kit per system necessary) 3.302,-
DTA104A53/61/62 *1 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc.) 2.737,-
*1) See pages 56-57 for details and exact adaptor type selection (for indoor unit installation, depend on indoor unit)
Type for 3N~ 400V power supply RWEYQ16T9.OU RWEYQ18T9.OU RWEYQ20T9.OU RWEYQ22T9.OU RWEYQ24T9.OU RWEYQ26T9.OU RWEYQ28T9.OU
RWEYQ8T9
RWEYQ8T9 RWEYQ8T9 RWEYQ8T9 RWEYQ10T9 RWEYQ12T9 RWEYQ14T9
RWEYQ8T9
Modules and kits required RWEYQ8T9 RWEYQ10T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9
RWEYQ8T9
Multi-kit * Multi-kit * Multi-kit * Multi-kit * Multi-kit * Multi-kit *
Multi-kit *
Nominal cooling capacity kW 44,8 50,4 56 61,5 67,0 73,5 80,0
Nominal heating capacity kW 50,0 56,5 62,5 69,0 75,0 82,5 90,0
Set Price Lei 104.142,- 110.193,- 117.751,- 123.802,- 156.213,- 139.898,- 148.436,-
Type for 3N~ 400V power supply RWEYQ30T9.OU RWEYQ32T9.OU RWEYQ34T9.OU RWEYQ36T9.OU RWEYQ38T9.OU RWEYQ40T9.OU RWEYQ42T9.OU
RWEYQ8T9 RWEYQ8T9 RWEYQ8T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9
RWEYQ10T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9
Modules and kits required
RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9 RWEYQ14T9
Multi-kit* Multi-kit* Multi-kit* Multi-kit* Multi-kit* Multi-kit* Multi-kit*
Nominal cooling capacity kW 84 89,5 95 100,5 107,0 113,5 120,0
Nominal heating capacity kW 94,5 100,5 106,5 112,5 120,0 127,5 135,0
Set Price Lei 175.873,- 183.431,- 191.969,- 197.040,- 205.578,- 214.116,- 222.654,-
Note: Please refer to the databook for the most up-to-date data.
Optional Accessories
Control Price Lei
- Water strainer kit included as standard with unit Standard
EKPCCAB4 VRV Configurator 1.561,-
KRC19-26 *1 Mechanical cool/heat selector 391,-
BRP2A81 Cool/ heat selector PCB 1.015,-
DTA104A53/61/62 External control adaptor for outdoor unit (Low Noise, Demand Limit, etc,) 2.737,-
*1) KJB111A Fixing box for mechanical cool/heat selector 191,-
BPMKS967A2 Branch provider for connection of 2 RA indoor units (for single module HP outdoors only) 4.311,-
BPMKS967A3 Branch provider for connection of 3 RA indoor units (for single module HP outdoors only) 4.602,-
34
Condensing Units
Optional Accessories
Control Price Lei
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
KRCS01-1 Remote air temperature sensor 556,-
For cooling: Saturated evaporating temperature: +6°; CAir temperature: +27°C DB / +19°C WB;
For heating: Saturated evaporating temperature: +46°C; Air temperature: +20°C DB
EXV control
2. Air Handling Unit with DX coil
(Daikin or 3rd party)
communication Thermistors
36
Air Handling Unit kits
P: Pair layout - One or more outdoor units connected to an (interlaced) coil of one AHU.
M: Mix or multi layout - Combination of (multiple) AHU(s) with (mix combination) or without (multi combination) VRV DX indoor(s). Only Z or Z’ control possible (no interlaced coils).
(1): For 65%<CR<75% please refer to the specifically required coil size
(2): Only Z or Z’ control possible (no interlaced coils)
(3): Technically is possible to connect H/R in pair combination, but there’s no benefit to do it
Select your Biddle air curtain range Biddle air curtain nomenclature
3,0m CYA S 150 DK 80 F S N
3 2,75m
Door 2,5m 2,5m No Biddle controller
2,3m 2,4m 2,3m
height (m) 2,15m B = White (RAL 9016)
2,0m Color
S = Grey (RAL 9006)
2
F = Free hanging
Installation type C = Cassette
R = Recessed
1 Capacity class (kW)
Small Medium
CYAS100DK80 CYAS150DK80 CYAS200DK100 CYAS250DK140 CYAM100DK80 CYAM150DK80 CYAM200DK100 CYAM250DK140
*BC/*SC *BC/*SC *BC/*SC *BC/*SC *BC/*SC *BC/*SC *BC/*SC *BC/*SC
Heating capacity Speed 3 kW 6,94 8,6 10,9 15,2 8,65 10,5 12,5 18,6
Power input Fan only Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Heating Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Dimensions Unit Height F/C/R mm 270/270/270
Width F/C/R mm 1.000/1.000/1.048 1.500/1.500/1.548 2.000/2.000/2.048 2.500/2.500/2.548 1.000/1.000/1.048 1.500/1.500/1.548 2.000/2.000/2.048 2.500/2.500/2.548
Depth F/C/R mm 590/821/561
Required ceiling void > mm 420
Weight Unit kg 56/59/61 66/83/88 83/102/108 107/129/137 57/68/66 73/88/93 94/111/117 108/136/144
Fan-Air flow rate Heating Speed 3 m³/h 1.164 1.746 2.328 2.910 1.605 2.408 3.210 4.013
Sound pressure level Heating Speed 3 dBA 47 49 50 51 50 51 53 54
Piping connections Liquid/OD/Gas/OD mm 6,35/12,7 9,52/15,9 6,35/12,7 9,52/15,9
Required accessories (should be ordered separately) Daikin wired remote control (BRC1H51(9)W/S/K / BRC1E53A/B/C)
Power supply Voltage V 230
Large
CYAL100DK125*BC/*SC CYAL150DK200*BC/*SC CYAL200DK250*BC/*SC CYAL250DK250*BC/*SC
Heating capacity Speed 3 kW 14,4 21,5 27,6 29,7
Power input Fan only Nom. kW 0,48 0,72 0,96 1,20
Heating Nom. kW 0,48 0,72 0,96 1,20
Dimensions Unit Height F/C/R mm 370/370/370
Width F/C/R mm 1.000/1.000/1.048 1.500/1.500/1.548 2.000/2.000/2.048 2.500/2.500/2.548
Depth F/C/R mm 774/1.105/745
Required ceiling void > mm 520
Weight Unit kg 76/81/83 100/118/141 126/151/155 157/190/196
Fan-Air flow rate Heating Speed 3 m³/h 3.100 4.650 6.200 7.750
Sound pressure level Heating Speed 3 dBA 53 54 56 57
Piping connections Liquid/OD/Gas/OD mm 9,52/15,9 9,52/19,1 9,52/19,1
Required accessories (should be ordered separately) Daikin wired remote control (BRC1H51(9)W/S/K / BRC1E53A/B/C)
Power supply Voltage V 230
(1) Favorable conditions: covered shopping mall or revolving door entrance (2) Normal conditions: little direct wind, no opposite open doors, building with ground floor only
(3) Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway
*Note: The table cells contain preliminary data
38
Biddle air curtain
Optional Accessories
Control Price Lei
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
EKMBPP1 Modbus adaptor for basic integration into Modbus 1.714,-
RTD-20 Advanced control adaptor for external fan speed control, outdoor air control, and Modbus integration 2.734,-
HRV unit VAM150FC9 VAM250FC9 VAM350J8 VAM500J8 VAM650J8 VAM800J8 VAM1000J8 VAM1500J8* VAM2000J8*
Air flow rate m³/h 150 250 350 500 650 800 1.000 1.500 2.000
External static pressure (max.) Pa 90 70 150 125 120 200 175 200 175
SEC class D B - - - - - - -
Electric power input at max fan speed W 132 161 97 164 247 303 416 548 833
Sound level dB 40,0 43,0 51,0 54,0 58,0 58,0 61,0 62,0 65,0
Price Lei 8.169,- 8.883,- 11.357,- 12.227,- 15.901,- 17.743,- 21.465,- 32.076,- 40.414,-
All VAM models are LOT6 compliant, please check the databook for detailed technical specs.
(*) Plenums for these models have to be ordered separately.
Standard Accessories
Air filter (class G3)
Optional Accessories
Control Price Lei
BRC301B61 Wired remote controller for HRV 1.172,-
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
RTD-10 Universal control adaptor 2.279,-
EKMBPP1 Modbus adaptor 1.714,-
RTD-20 Advanced control adaptor for VAM control based on CO2 or presence sensor input 2.734,-
40
Ventilation units
NEW GSIEKA
Electrical heater for VAM
ʯ Total solution for fresh air with Daikin supply of both VAM
and electrical heaters
ʯ Increased comfort in low outdoor temperature thanks
to the heated outdoor air
ʯ Integrated electrical heater concept
(no additional accessories required)
ʯ Standard dual flow and temperature sensor
ʯ Flexible setting with adjustable setpoint
ʯ Increased safety with 2 cut-outs: manual & automatic
VKM-GBM
VRV Heat Reclaim Ventilation (HRV) Units
with DX coil + Humidification
Standard Accessories
Air filter (class G3)
Optional Accessories
Control Price Lei
BRC1H52W/S/K Premium wired remote controller with white/sliver/black color 1.152,-
RTD-10 Universal control adaptor 2.279,-
EKMBPP1 Modbus adaptor 1.714,-
NEW EKVDX-A
DX coil for air processing
Post heating or cooling of fresh air to lower the load on
the air conditioning system
Optional Accessories
Price Lei
BRC1H52W/S/K New premium Madoka wired controller white/silver/black 1.152,-
KDAP25A36 Air discharge adaptor for round ducts EKVDX32 771,-
KDAP25A56 Air discharge adaptor for round ducts EKVDX50 905,-
KDAP25A71 Air discharge adaptor for round ducts EKVDX80 1.875,-
KDAP25A140 Air discharge adaptor for round ducts EKVDX100 2.894,-
42
Ventilation units
ALB-R/LB(S)(1) 02 03 04 05 06 07
ALB-R/LB Lei 57.465,- 67.756,- 88.917,- 99.329,- 127.165,- 135.330,-
ALB-R/LBS (Smart) Lei 50.746,- 61.152,- 82.180,- 92.793,- 120.654,- 129.022,-
Airflow/Airflow Smart m3/h 300 600 1.200 1.500 2.500/2.300 3.000
Thermal efficiency(2)/Thermal efficiency(2) Smart % 93/90 93/91 93/90 92/90 94/92 93/91
External static pressure Nom. Pa 100 100 100 100 100 100
Current/Current Smart Nom. A 0,52 1,17 1,91 2,48 4,39/3,76 5,39
Power input/Power input Smart Nom. kW 0,12 0,27 0,44 0,57 1,01/0,87 1,24
SFPv (3) /SFPv Smart kW/m3/s 1,24 1,49 1,25/1,28 1,31/1,32 1,42/1,32 1,46
Electrical supply Phase ph 1 1 1 1 1 1
Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60
Voltage V 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac
Dimensions unit Width mm 920 1.100 1.600 1.600 2.000 2.000
Height mm 280 350 415 415 500 500
Length mm 1.660 1.800 2.000 2.000 2.000 2.000
Weight unit kg 125 180 270 280 355 360
Width mm 250 400 500 500 700 700
Rectangular duct flange
Height mm 150 200 300 300 400 400
Unit sound power level/Unit sound power level Smart dBA 48 54 57 53 62/60 57
Unit sound pressure level(4)/Unit sound pressure level Smart dBA 34 39 41 37 46 41
NEW ALD-HEFB
Electrical heater for Modular L Smart
ʯ Total solution for fresh air with Daikin supply of both Modular L
Smart and electrical heaters
ʯ Increase comfort in low outdoor temperature thanks
to the heated outdoor air
ʯ Integrated electrical heater concept
Standard dual flow and temperature sensor
Notes: (1) R= right connection and L= left connection; S = Smart Solution (Daikin PCB)
(2) Nominal condition: Outdoor: -10°C (-5°C for Modular Light Smart), 90% Indoor: 22°C, 50%
(3) SFPv is a parameter that quantifies the fan efficiency (the lower it is the better will be). This reduces if airflow decreases.
(4) EN 3744. Surrounding, Directivity (Q) = 2, @1,5m distance
(5) For each unit 4 pcs have to be ordered.
(6) For each unit 2 Number of filters (return air side and Fresh air side) with any combination
(7) All coil modules are suitable with Modular T Pro version only
44
Ventilation units
› 5 Predefined sizes
› Plug & Play control solution
› Compact unit from 550 mm width (for unit up to 1.100 m3/h)
› Wide air flow coverage from 200 to 4.200 m3/h
› Right and left configuration
› Pro (open control platform) and Smart
(Daikin control platform) version
› Excellent indoor air quality (IAQ). Up to three filtration stages: Modular T
more than 90% PM1 in outdoor air are deleted achieving
the best IAQ
› DX and water coil available as option (Pro Version) › Available also with integrated heating coil (water)
› Recirculation mixing damper (option) › VAM PCB (Smart)
› BIM file available at www.daikin.eu/BIM › F1/F2 and P1/P2 protocol (Smart)
› CO2 level management thanks to optional CO2 sensor › Fully compatible with SkyAir and VRV systems (Smart)
› 50 mm double skin panels, mineral wool insulated › Direct integration into DIII-net (Smart)
› Modbus and BACnet compatible (accessory) › Controlled through any Daikin local, centralized controllers iTAB,
iTM, iTC (Smart)
46
Accessories
Refnet Joint for 3-pipe systems - metric KHRQM23M20T KHRQM23M29T KHRQM23M64T KHRQM23M75T
Capacity index up to 200 201–290 291–640 > 640
Price Lei 997,- 1.143,- 1.851,- 2.499,-
Note: these BS-Boxes can be used on VRV IV H/R (REYQ-U), Water-Cooled VRV IV (RWEYQ-T9) and Replacement
VRV H/R (RQCEQ-P3) systems.
Optional Accessories
Price Lei
KRC19-26 *1 Mechanical cool/heat selector 391,-
DTA114A61 Adaptor for multi-tenant applications 1.099,-
EKBSVQLNP Sound reduction kit (sound insulation) 1.037,-
*1) KJB111A Fixing box for mechanical cool/heat selector 191,-
Note: these BS-Boxes can be used on VRV IV H/R (REYQ-U), Water-Cooled VRV IV (RWEYQ-T9) and
Replacement VRV H/R (RQCEQ-P3) systems.
Type for 1~ 230V power supply BS4Q14AV1B BS6Q14AV1B BS8Q14AV1B BS10Q14AV1B BS12Q14AV1B BS16Q14AV1B
Number of ports (independent C/H selection) 4 6 8 10 12 16
Max. number of indoor units per port 5
Connectable capacity index per port 15 ~ 140 *
Max. total capacity index on BS Box 400 600 750
Price Lei 12.579,- 17.235,- 22.670,- 27.249,- 32.108,- 40.656,-
* Connection of higher capacity index is possible by joining two adjacent ports together using optional joint (KHRP26A250T 2.622,- Lei).
Optional Accessories
Price Lei
KDDN26A4 Sound reduction kit for BS4Q14AV1B 8.518,-
KDDN26A8 Sound reduction kit for BS6Q14AV1B and BS8Q14AV1B 10.068,-
KDDN26A12 Sound reduction kit for BS10Q14AV1B and BS12Q14AV1B 12.595,-
KDDN26A16 Sound reduction kit for BS16Q14AV1B 14.288,-
KHFP26A100C Closed pipe kit 427,-
Note: these BS -Boxes can be used on VRV5 H/R (REYA-A R-32) only.
Type for 1~230V power supply BS4A14AV1B BS6A14AV1B BS8A14AV1B BS10A14AV1B BS12A14AV1B
No. Of connectable indoor units 4 6 8 10 12
Connectable capacity index 400 600 750
Allowed sizes of indoor units 10-140*
Max allowed amount of BSSV box in flowthrough 4 (4 x 4 port BSSV = 16 ports)
Max capacity index of indoor units connected to
750
all BSSV in flowthrough combined
Price Lei 12.579,- 17.235,- 22.670,- 27.249,- 32.108,-
*250 if 2 ports are combined, joint kit required EKBSJK
48
Accessories
Accessories
New Measuring Tool Price Lei
SDGT_GAUGE 20,-
COMPONENTS
obligatory when Wago interface modules should be used
REQUIRED
REQUIRED for each Wago node
787-712 1.356,-
Main Power Supply for node
REQUIRED for each Wago node
750-960 281,-
PROFIBUS fieldbus connector for node
REQUIRED for each Wago node
750-600 147,-
End module for node
Internal booster power supply module. Required after each 32 contacts or after every group of digital output / analogue
750-613 1.404,-
input modules if it is followed by any digital input modules.
750-400 2-channel digital input module (24VDC supplied to circuit) 251,-
750-432 4-channel digital input module (24VDC supplied to circuit) 354,-
750-430 8-channel digital input module (24VDC supplied to circuit) 500,-
750-513/000-001 2-channel relay output module (max. 2A, 230VAC or 30VDC load) 551,-
750-504 Voltage contact output (output voltage DC24V/0,5mA) 343,-
750-454 2-channel analog input module for 4~20 mA signal 2.255,-
INPUT/OUTPUT COMPONENTS
Intelligent Tablet Controller with local & cloud control Price Lei
DCC601A51
Itab controller with cloud connection for Split, Sky Air, VRV, ventilation, air curtains and hot water
WAGO power CPU module I/O module 5.140,-
supply (up to 32 indoors)
AL-CCD07-VESA-1
5.702,-
Optional screen for local control (wired option which can be mounted on the wall)
DCM601B51
33.170,-
Main unit for advanced control of up to 64 addresses (groups/units)
DGE601A52
7.034,-
Main iTM adaptor - expansion adaptor for control of an additional 64 addresses.
DGE601A53
Additional slot adaptor - Up to 6 additional slot adaptors can be connected to DGE601A52. Maximum of 512 addresses can 4.780,-
be controlled from single iTM main unit (DGE601A52 plus 6x DGE601A53)
Adaptor for central monitoring board – provides potential-free contacts for operation/error monitoring and on/
DCS302A52-9 1.257,-
off control of units connected to Controller. One adaptor required for each iTM main and each iTM Plus Adaptor.
Proportional Power Distribution (PPD) Option – calculates contribution of each
DCM002A51 13.010,-
indoor unit to the total power consumption of the VRV System
Energy Navigator Software Option - provides advanced energy consumption analyses
DCM008A51 27.463,-
and provides means to limit the energy consumption of the VRV system
BACnet Server Option - allows to use the iTM to monitor and/or control
DCM009A51 11.424,-
external devices connected using the BACnet/IP protocol.
DCM007A51 HTTP option defines interface to monitor/operate Daikin units from an external application via iTM. 9.289,-
50
Accessories
Connectivity and integration possibilities Manage, monitor and control indoor climate
from anywhere
Simple to advanced edge controllers
Various interfaces Limits the necessity for on-site control
Advanced security Minimizes downtime and engineer call outs
Optimized maintenance
Monitoring of indoor air quality
Main applications
Ranges
Light commercial and commercial systems VRV and Skyair, air
curtains. Integration
through I/O. BACnet
available in 2024.
Composition
USER INTERFACE
CLOUD
Internet Connection
IAQ control and Multi-site Demand
monitoring management Control
BUILDING
DGE601A51
13.736,-
Edge Controller - Up to 512 units with extension modules via Daikin Cloud Plus
DGE602A51
10.682,-
DGE602A51 - Max 64 units via Daikin Cloud Plus
DGE601A52
DIII Plus Adaptor - Allows connection of additional 64 indoor units/groups. Only one adaptor can be connected (for 7.034,-
more units, use DIII Plus Adaptor Slots)
DGE601A53
DIII Plus Adaptor - Allows connection of additional 64 indoor units/groups. Up to 6 Adaptor Slots can be added to a 4.780,-
DIII Plus Adaptor
52
Accessories
Service Packages
1 2 3
CONTROL & REMOTE SUPPORT ADVICE &
MONITORING & DIAGNOSTIC* OPTIMIZATION*
Building Integration
Alarm History & Email Notification
Power Consumption Distribution
Remote Field Settings
Site History ✗
Prediction & Email Notification ✗
Operational Data Access ✗
Indoor and Outdoor Units Analysis ✗
Periodical Analysis & Optimisation Advice by
Daikin ✗
Daikin Service
Free on
Software (obligatory) requires Windows7 SP1 or later, Windows 8.0 /8.1 /10
demand
RS-SE
718,-
Service tool for checking connection of K.RSS external wireless air temperature sensor
99S0038
on request
Magnet for manual operation of expansion valves, 17,5 mm ID
999133T
on request
Magnet for manual operation of expansion valves, 22,0 mm ID
999134T
on request
Magnet for manual operation of expansion valves, 24,0 mm ID
999132T
on request
Magnet for manual operation of expansion valves, 24,5 mm ID
54
Control Options & accessories - indoor
BRC7FB532F
price depends (grey panel) BRC4C65 BRC4C65 BRC4C65 BRC7GA53-9 BRC7C58 BRC7EA630
Infrared remote control (incl. receiver) (white designer
on model BRC7EB530W
panel)
(standard
BRC7FB532FB
panel) (4,5)
(black designer
panel) (3,9)
1.185,- check p. 6 604,- 604,- 604,- 1.641,- 1.556,- 1.137,-
BRP069C51 - Onecta app 633,- • • • • • • • •
Madoka
BRC1H52W (White) / BRC1H52S (Silver) / BRC1H52K
1.152,-
• • • • • • • •
(Black) User-friendly wired remote controller with (mandatory (mandatory (mandatory (mandatory (mandatory (mandatory (mandatory (mandatory
premium design for R-32) for R-32) for R-32) for R-32) for R-32) for R-32) for R-32) for R-32)
DCM601B51 - intelligent Touch Manager 33.170,- • • • • • • • •
Centralised control systems
Adapter for external central monitoring/control KRP2A52 KRP2A53 (1b) KRP2A51(1b) KRP2A62 KRP2A61 (1c)
depends on (50-125)
(controls 1 entire system)
model
2.176,- 2.103,- 2.176,- 2.176,- on request 2.020,-
Adapter for keycard and/or window contact
connection (1)(6)ок
570,- BRP7A53( 1a) BRP7A53 (1b) BRP7A54 (1b) BRP7A51 (1b) BRP7A51 (1b) BRP7A52 BRP7A53 BRP7A51 (1c)
Adapter for multi-tenant applications
(24VAC PCB power supply interface)
1.099,- DTA114A61 DTA114A61 DTA114A61 DTA114A61 DTA114A61 DTA114A61 - DTA114A61
External control adapter for outdoor unit (installation DTA104A61 DTA104A61 DTA104A51 (1c)/
on indoor unit)
1.099,- - - DTA104A53
(1b) (1b)
DTA104A61 - DTA104A61 (1c)
price KRP1H98A (3) KRP1BC101
Installation box / Mounting plate for adapter PCBs (For KRP1BC101 KRP1BC101 KRP1BC101 KRP4B93 KRP1B97 KRP4A93
depends on KRP1BC101 (50-125)
units where there is no space in the switchbox)
model 744,- 401,- 401,- 401,- 401,- 886,- 1.050,- 886,-
Wiring kit for Remote ON/OFF or Forced OFF Standard Standard - Standard Standard Standard Standard Standard
Relay PCB for output signal of refrigerant sensor 567,- ERP01A51 (1b) ERP01A50 (1b) ERP01A51 (1b) ERP01A50 (1b) ERP01A50 (1b) ERP01A51 (1c) ERP01A51 (1c) ERP01A51 (1c)
(1)Following installation box is necessary for these adapters: 1a-KRP1H98; 1B-KRP1BC101; 1C- KRP4B93 (6) Only possible in combination with BRC1H*
(2) Not recommended because of the limitation of the functions (7) When fixing box is required, use KJB212A, KJB311A or KJB411A depending on the size of the controller
(3) Option not available in combination with BYCQ140EGF(B) (8) Option KEK26-1A (Noise filter) is required when installing DCS301B51
(4) Cannot be combined with sensor kit (9) The active airflow circulation function is not available for this controller.
(5) Independently controllable flaps function not available (10) Up to 2 adaptor PCBs can be installed per installation box
(11) Only one installation box can be installed per indoor unit
VRV Pricelist 2024-202555
Control Options & accessories - indoor
SB.K.RSS_RFC
K.RSS - External wireless temperature sensor 825,-
(EKEWTSC-2 +
K.RSS)
• • • • •
917,-
price
Adapter with 2 output signals (Compressor / Error, KRP1BA58 (1)(3) KRP1B57 (1) - - - -
depends on
Fan output)
model 1.073,- 935,-
Adapter with 4 output signals price
EKRP1C12 (1)(3) EKRP1B2 (1) EKRP1B2 KRP1B61 KRP1B56 EKRP1B2(1)
(Compressor / Error, Fan, Aux. heater, Humidifier depends on
output) model 523,- 970,- 970,- 1.196,- 935,- 970,-
price
Adapter for centralised external monitoring/control KRP4A53 (1)(3) KRP4A53 (1) KRP4A51 (1) KRP4A51 KRP4A54-9 (1) KRP4A52(1)
depends on
via dry contacts and setpoint control via 0-140Ω
model
1.154,- 1.154,- 1.154,- 1.154,- 1.154,- 1.154,-
price
Adapter for external central monitoring/control KRP2A52 KRP2A51 (1) KRP2A61 KRP2A53 (1) KRP2A51(1)
Adapters
depends on
(controls 1 entire system)
model
2.176,- 2.176,- 2.020,- 2.103,- 2.176,-
Adapter for keycard and/or window contact
connection (1)(6)
570,- BRP7A53 BRP7A53 (1) BRP7A51 (1) BRP7A51 BRP7A54 BRP7A51
price DTA114A61 DTA114A61 - - DTA114A61 DTA114A61 (1)
Adapter for multi-tenant applications
depends on
(24VAC PCB power supply interface)
model 1.099,- 1.099,- 1.099,- 1.099,-
price - - DTA104A61 (1) DTA104A61 DTA104A53 DTA104A61
External control adapter for outdoor unit (installation
depends on
on indoor unit)
model 2.827,- 2.827,- 2.737,- 2.827,-
price KRP1H98A
Installation box / Mounting plate for adapter PCBs (For KRP1BC101 KRP1C96 (10) (11) - KRP1BC101 KRP1BC101
depends on KRP1BC101
units where there is no space in the switchbox)
model 744,- 401,- 756,- 401,- 401,-
Wiring kit for Remote ON/OFF or Forced OFF Standard Standard Standard Standard - Standard
(1) Installation box is necessary for these adapters (6) Only possible in combination with BRC1H* / BRC1E*
(2) Not recommended because of the limitation of the functions (7) When fixing box is required, use KJB212A, KJB311A or KJB411A depending on the size of the controller
(3) Option not available in combination with BYCQ140EGF(B) (8) Option KEK26-1A (Noise filter) is required when installing DCS301B51
(4) Cannot be combined with sensor kit (9) The active airflow circulation function is not available for this controller.
(5) Independently controllable flaps function not available (10) Up to 2 adaptor PCBs can be installed per installation box
(11) Only one installation box can be installed per indoor unit
56
Control Options & accessories - indoor
Concealed ceiling units (duct units) Ceiling suspended units Wall mounted units Floor standing units
High ESP High ESP 1-way blow 4-way blow Concealed Free-standing
BRC7EA629 /
BRC4C65 BRC4C65 BRC7GA53-9 BRC7C58 BRC4C65 BRC4C65
BRC7EA628
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
• • • • • • •
KRCS01-4 KRCS01-6B KRCS01-4 KRCS01-4 KRCS01-1 KRCS01-4 KRCS01-1
• • • • •
SB.K.RSS_FDA SB.K.RSS_FDA
(EKEWTSC-1 + K.RSS) (EKEWTSC-1 + K.RSS)
917,- 917,-
KRP1C64 (1) KRP1C65 KRP1B54 - - - -
1.177,- 1.550,- 1.104,-
EKRP1B2 (1) EKRP1C14 - - KRP1B56 KRP1B56 KRP1B61
970,- 567,- 935,- 935,- 1.196,-
KRP4A51 (1) KRP4A51 KRP4A52 (1) KRP4A53 (1) KRP4A51 (1) KRP4A54-9 KRP4A51
Daikin
Service & Solutions
Saving energy doesn’t stop with the purchase or Our Daikin design team is constantly striving to
installation of energy-efficient equipment; it has to be improve the energy efficiency of our systems.
kept running under optimum conditions.
We at Daikin Service are here to support you in
Good maintenance and servicing are key elements in keeping your units up and running efficiently by
ensuring the maximum performance. means of optimised commissioning and start-up,
regular and preventative maintenance, remote
Are you sure the filters are clean and none of the monitoring, improving the performance of units, and
components are defective? providing cost effective upgrades to benefit from
Are all of your settings correct? the efficiency gains from our latest state of the art
technology.
Any of these things may lead to a reduced level of
comfort. And while you may not notice the difference
right away, you will certainly notice it at the end of
the year – when you pay your energy bill.
Optimisation
and upgrades European Remote Upgrading /
Monitoring Center optimisation
Keep the
installation in
top condition Care Packages Installation support Commissioning
Parts and
repairs
Spare parts Repair service
58
Service & Solutions
Commissioning
To guarantee your Daikin unit efficiency and long
term performance, Daikin offers the professional
start-up of your Daikin system by highly
qualified, OEM educated engineers as part of the
commissioning services.
The prices listed are based on completion of the Pre-Commissioning checklist which covers a range of core activities including the general
conditions at the site, provision of power and the required electrical distribution as well as installation related topics. This ensures that the
service can be provided efficiently, on time and giving the best results. For the latest edition of the Pre-Commissioning checklist please
visit: www.daikin-ce.com
Maintenance VRV
Maintenance is the key element to ensure the quality, efficiency and flawless operation of any asset.
Our Care agreements are based on Preventive maintenance and regular Regular maintenance of a unit or
years of experience to ensure you service is a key component in securing system ensures that electricity costs
reap the full benefits of having Daikin your investment. Dust, temperature, and performance are not jeopardized,
Certified engineers maintain your humidity and load degrade the and that the safety features and the
equipment. reliability and performance of a VRV entire system are in line with the latest
system over time. standards and regulations.
Daikin Cares contains 3 different levels of maintenance agreements catering to your every need. In addition
to these 3 Care packages Daikin offers a comprehensive set of options you can choose from.
F-Gas Care is the minimal requirement to fulfil current legislation requirements, and makes sure your unit is
Care operating under the F-Gas directive.
Preventive Care Preventive Care secures your VRV system and keeps it running under optimal conditions for the long time.
Exclusive Care provides maximum equipment availability at the minimum Total Cost of Ownership. This includes
Exclusive Care access to experts trough remote monitoring and actionable yearly energy reports.
Inspection Maintenance
Preventive Exclusive
Services Care
Care Care
Leak check Inspection based on predefined activities
Validated Log book according to F-Gas
Maintenance based on predefined activities -
Optimizations and analysis of the retrieved data -
On-site VRV system diagnostic and/or analysis during service intervention -
Recorded, retrievable service history of each VRV system -
Access to technical assistance and repair service -
Soft- and firmware upgrades as needed and if required -
Validated Log book -
Access to Emergency support & callout -
Lifecycle report - -
DCS - Remote connection for troubleshooting & support - -
Yearly actionable report on energy optimization and usage - -
Spring Cleaning: Outdoor units option option
Spring Cleaning: Indoor units option option
Night Time Surcharge option option
Description Care: Leak Check VRV Price Lei Preventive Care Price Lei Exclusive Care Price Lei
Outdoor unit VRV Mini CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_MI 980,72 CE.PS_VRV_EC_MI on request
Outdoor unit VRV ≤12 HP CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_12 1.344,87 CE.PS_VRV_EC_12 on request
Outdoor unit VRV ≥14 HP CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_14 1.466,25 CE.PS_VRV_EC_14 on request
Outdoor unit VRV HR+W CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_HRW 1.344,87 CE.PS_VRV_EC_HRW on request
AHU+ERQ CE.PS_VRV_C_FGAS 1.009,73 CE.PS_AHU_PC_ERQ 1.344,87 CE.PS_AHU_EC_ERQ on request
BIDDLE+ERQ CE.PS_VRV_C_FGAS 1.009,73 CE.PS_BIDDLE_ERQ_PC on request CE.PS_BIDDLE_ERQ_EC on request
Indoor unit Cassette CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_IU_CAS on request CE.PS_VRV_EC_IU_CAS on request
Indoor unit Ceiling CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_IU_CEI on request CE.PS_VRV_EC_IU_CEI on request
Indoor unit Floorstanding CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_IU_FLO on request CE.PS_VRV_EC_IU_FLO on request
Indoor unit Wall Mounted CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_IU_WAL on request CE.PS_VRV_EC_IU_WAL on request
Indoor unit BIDDLE DX CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_IU_BID on request CE.PS_VRV_EC_IU_BID on request
ACC CE.PS_VRV_C_FGAS 1.009,73 CE.PS_VRV_PC_ACC 1.384,61 CE.PS_VRV_EC_ACC on request
Spring cleaning outdoor CE.PS_VRV_CL_OU 677,80 CE.PS_VRV_CL_OU 677,80
Spring cleaning indoor CE.PS_VRV_CL_IU 274,99 CE.PS_VRV_CL_IU 274,99
Night time working CE.PS_LA_HOUR100 885,12 CE.PS_LA_HOUR100 885,12
Options
Description Price Lei
Repairs on request
Inspection DX LARGE >20HP CE.PS_VRV_INSP_L 3.404,06
Inspection DX MID 10hp -20 CE.PS_VRV_INSP_M 3.404,06
Inspection DX SMALL <10HP CE.PS_VRV_INSP_S 2.596,28
Chemical analyse of refrigerant CE.PS_REF_ANALYSIS 789,52
Power supply analyse CE.PS_PWR_ANALYSIS 2.368,56
Oil analysis CE.PS_MA_ACIDTEST 744,40
Monday-Friday 17-22h Weekend, Holiday, Nights
Emergency support on request on request
Call out Time 24h Call out Time 16h Call out Time 8h Call out Time 4h
Call out Time (48h included in PR. and EX. CARE) on request on request on request on request
NOTE: T he listed prices are subject to change and might change without prior notification. Note that the prices are to be understood as NET prices without VAT and travel.
The listed prices are based on order confirmation minimum 10 days before commencement of work.
60
Service & Solutions
E-Parts
Find the correct spare part for your Daikin unit, check
availability (real-time) and order online.
Your advantages:
› Always available
› Fast handling
› „real time“ availability
› Free shipment
› Flexible delivery address
› Prompt feedback
To register to use
the E-Parts service
http://eparts.daikin-ce.com
Service Academy
With the Daikin Service Academy we want to offer › Installation & Pre-Commissioning
a uniform European learning program for service › Commissioning
technicians to become the best of the best. › Maintenance
› Troubleshooting & Repair
› Ensure that our partners have skilled labour › Application & Design
available
› Enable and deliver high quality Service to our end
users
› Enhance performance and efficiency, using less time
for service interventions Want to know more?
› Improve quality and hence customer satisfaction
on site Please contact us for more information about the
› Foster career paths to keep service technicians in Daikin Academy Central Europe:
the HVAC-R industry academy@daikin-ce.com
› Offer trainings in local language wherever possible
Remote Monitoring
Services
The latest technology matched with superb
service to improve the efficiency and reliability
of your HVAC-R installation.
Connected air conditioning works smarter. We offer several ways to manage
your products and installations remotely. From performance monitoring to
predictive logic and analyses and more, our Intelligent Network is a cost-
efficient way to increase the security, uptime and reliability of your installation.
Data is our raw material, and We know that connecting a system Our web-based service provides
data analytics is our product. The to the cloud can often be a real reliable and secure remote
continuous monitoring and analysis challenge – but that‘s no longer monitoring. Our top priority is to earn
of a system’s operating data is not your problem. We’ll take care of the your trust. Daikin Cloud Service meets
only the key to ensuring efficient connection, including the mobile the highest security standards in all
operation, cutting operating and network and the router, both of which respects – safeguarding your data
maintenance costs and optimizing are remotely monitored to maximize privacy as well as transporting and
user comfort. Data analysis also infrastructure reliability. storing your data securely at all times.
provides further valuable and often
surprising insights.
64
Notes
66
Notes
NEW