You are on page 1of 3

STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton

petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S - 2
Location Palm Spring PIK 2 GL -
Tested by - GWL -6.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 14 April 2023
Date of Test

Reading Local Total Local Total Total Friction (Tf) kg/cm


Depth Presure Gauge friction ratio qc (cone Resistance) friction ratio (fs/qc) (%)
Friction Friction Friction Consistensi
(m) 2) (fs/qc) (%)
x kgf y kgf (fs)kg/cm (Lf)Kg/cm (Tf)kg/cm 0 1000 2000 3000 0 5 10 15
0 100 200 300
0.00 0 0 0

Depth (m)
-0.20

Depth (m)

Depth (m)
-0.40 5 7 0.20 4 4 4.00 Soft
-0.60 5 8 0.30 6 10 6.00 Soft
-0.80 4 7 0.30 6 16 7.50 Very Soft
-1.00 4 5 0.10 2 18 2.50 Very Soft -1 -1 -1
-1.20 10 15 0.50 10 28 5.00 Firm
-1.40 9 12 0.30 6 34 3.33 Soft
-1.60 10 14 0.40 8 42 4.00 Firm
-1.80 15 20 0.50 10 52 3.33 Firm
-2.00 10 12 0.20 4 56 2.00 Firm -2 -2 -2
-2.20 7 9 0.20 4 60 2.86 Soft
-2.40 8 11 0.30 6 66 3.75 Soft
-2.60 6 10 0.40 8 74 6.67 Soft
-2.80 10 13 0.30 6 80 3.00 Firm
-3.00 11 15 0.40 8 88 3.64 Firm -3 -3 -3
-3.20 6 8 0.20 4 92 3.33 Soft
-3.40 5 10 0.50 10 102 10.00 Soft
-3.60 4 6 0.20 4 106 5.00 Very Soft
-3.80 5 7 0.20 4 110 4.00 Soft
-4.00 3 5 0.20 4 114 6.67 Very Soft -4 -4 -4
-4.20 5 8 0.30 6 120 6.00 Soft
-4.40 4 6 0.20 4 124 5.00 Very Soft
-4.60 5 7 0.20 4 128 4.00 Soft
-4.80 3 5 0.20 4 132 6.67 Very Soft
-5.00 4 7 0.30 6 138 7.50 Very Soft -5 -5 -5
-5.20 5 6 0.10 2 140 2.00 Soft
-5.40 7 10 0.30 6 146 4.29 Soft
-5.60 5 8 0.30 6 152 6.00 Soft
-5.80 8 11 0.30 6 158 3.75 Soft
-6.00 10 12 0.20 4 162 2.00 Firm -6 -6 -6
-6.20 5 10 0.50 10 172 10.00 Soft
-6.40 7 12 0.50 10 182 7.14 Soft
-6.60 10 14 0.40 8 190 4.00 Firm
-6.80 11 15 0.40 8 198 3.64 Firm
-7.00 12 17 0.50 10 208 4.17 Firm -7 -7 -7
-7.20 10 15 0.50 10 218 5.00 Firm
-7.40 12 16 0.40 8 226 3.33 Firm
-7.60 14 18 0.40 8 234 2.86 Firm
-7.80 11 15 0.40 8 242 3.64 Firm
-8.00 15 18 0.30 6 248 2.00 Firm -8 -8 -8
-8.20 14 16 0.20 4 252 1.43 Firm
-8.40 10 15 0.50 10 262 5.00 Firm
-8.60 12 16 0.40 8 270 3.33 Firm
-8.80 13 15 0.20 4 274 1.54 Firm
-9.00 15 19 0.40 8 282 2.67 Firm -9 -9 -9
-9.20 16 22 0.60 12 294 3.75 Firm
-9.40 17 24 0.70 14 308 4.12 Firm
-9.60 15 25 1.00 20 328 6.67 Firm
-9.80 19 27 0.80 16 344 4.21 Firm
-10.00 15 21 0.60 12 356 4.00 Firm -10 -10 -10
-10.20 17 22 0.50 10 366 2.94 Firm
-10.40 18 25 0.70 14 380 3.89 Firm
-10.60 20 25 0.50 10 390 2.50 Firm
-10.80 22 27 0.50 10 400 2.27 Firm
-11.00 15 25 1.00 20 420 6.67 Firm -11 -11 -11
-11.20 25 27 0.20 4 424 0.80 Firm
-11.40 20 29 0.90 18 442 4.50 Firm
-11.60 27 30 0.30 6 448 1.11 Firm
-11.80 30 32 0.20 4 452 0.67 Firm
-12.00 10 15 0.50 10 462 5.00 Firm -12 -12 -12
-12.20 15 19 0.40 8 470 2.67 Firm
-12.40 17 22 0.50 10 480 2.94 Firm
-12.60 27 35 0.80 16 496 2.96 Firm
-12.80 29 37 0.80 16 512 2.76 Firm
-13.00 30 35 0.50 10 522 1.67 Firm -13 -13 -13
-13.20 30 40 1.00 20 542 3.33 Firm
-13.40 25 35 1.00 20 562 4.00 Firm
-13.60 29 37 0.80 16 578 2.76 Firm
-13.80 35 40 0.50 10 588 1.43 Stiff
-14.00 25 39 1.40 28 616 5.60 Firm -14 -14 -14
-14.20 35 45 1.00 20 636 2.86 Stiff
-14.40 37 47 1.00 20 656 2.70 Stiff
-14.60 45 50 0.50 10 666 1.11 Stiff
-14.80 40 50 1.00 20 686 2.50 Stiff
-15.00 60 65 0.50 10 696 0.83 Very Stiff -15 -15 -15
-15.20 65 70 0.50 10 706 0.77 Very Stiff
-15.40 75 80 0.50 10 716 0.67 Very Stiff
-15.60 85 90 0.50 10 726 0.59 Very Stiff
STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton
petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S - 2
Location Palm Spring PIK 2 GL -
Tested by - GWL -6.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 14 April 2023
Date of Test

Reading Local Total Local Total Total Friction (Tf) kg/cm


Depth Presure Gauge friction ratio qc (cone Resistance) friction ratio (fs/qc) (%)
Friction Friction Friction Consistensi
(m) 2) (fs/qc) (%)
x kgf y kgf (fs)kg/cm (Lf)Kg/cm (Tf)kg/cm 0 1000 2000 3000 0 5 10 15
0 100 200 300
-15.80 100 105 0.50 10 736 0.50 Very Stiff 0 0
-16.00 60 75 1.50 30 766 2.50 Very Stiff -16 -16 -16
-16.20 80 95 1.50 30 796 1.88 Very Stiff
-16.40 45 55 1.00 20 816 2.22 Stiff
-16.60 55 65 1.00 20 836 1.82 Stiff
-16.80 50 70 2.00 40 876 4.00 Stiff
-17.00 65 75 1.00 20 896 1.54 Very Stiff -17 -17 -17
-17.20 45 55 1.00 20 916 2.22 Stiff
-17.40 70 85 1.50 30 946 2.14 Very Stiff
-17.60 90 95 0.50 10 956 0.56 Very Stiff
-17.80 95 100 0.50 10 966 0.53 Very Stiff
-18.00 110 125 1.50 30 996 1.36 Very Stiff -18 -18 -18
-18.20 80 100 2.00 40 1036 2.50 Very Stiff
-18.40 75 95 2.00 40 1076 2.67 Very Stiff
-18.60 90 100 1.00 20 1096 1.11 Very Stiff
-18.80 65 75 1.00 20 1116 1.54 Very Stiff
-19.00 60 80 2.00 40 1156 3.33 Very Stiff -19 -19 -19
-19.20 100 105 0.50 10 1166 0.50 Very Stiff
-19.40 110 115 0.50 10 1176 0.45 Very Stiff
-19.60 120 150 3.00 60 1236 2.50 Hard
-19.80 95 110 1.50 30 1266 1.58 Very Stiff
-20.00 100 110 1.00 20 1286 1.00 Very Stiff -20 -20 -20
-20.20 100 120 2.00 40 1326 2.00 Very Stiff
-20.40 80 105 2.50 50 1376 3.13 Very Stiff
-20.60 60 75 1.50 30 1406 2.50 Very Stiff
-20.80 55 65 1.00 20 1426 1.82 Stiff
-21.00 50 60 1.00 20 1446 2.00 Stiff -21 -21 -21
-21.20 55 75 2.00 40 1486 3.64 Stiff
-21.40 85 90 0.50 10 1496 0.59 Very Stiff
-21.60 80 95 1.50 30 1526 1.88 Very Stiff
-21.80 120 130 1.00 20 1546 0.83 Hard
-22.00 135 150 1.50 30 1576 1.11 Hard -22 -22 -22
-22.20 95 120 2.50 50 1626 2.63 Very Stiff
-22.40 150 170 2.00 40 1666 1.33 Hard
-22.60 150 155 0.50 10 1676 0.33 Hard
-22.80 100 105 0.50 10 1686 0.50 Very Stiff
-23.00 70 85 1.50 30 1716 2.14 Very Stiff -23 -23 -23
-23.20 60 70 1.00 20 1736 1.67 Very Stiff
-23.40 50 55 0.50 10 1746 1.00 Stiff
-23.60 60 75 1.50 30 1776 2.50 Very Stiff
-23.80 55 60 0.50 10 1786 0.91 Stiff
-24.00 80 85 0.50 10 1796 0.63 Very Stiff -24 -24 -24
-24.20 95 100 0.50 10 1806 0.53 Very Stiff
-24.40 105 110 0.50 10 1816 0.48 Very Stiff
-24.60 120 150 3.00 60 1876 2.50 Hard
-24.80 110 120 1.00 20 1896 0.91 Very Stiff
-25.00 150 180 3.00 60 1956 2.00 Hard -25 -25 -25
-25.20 180 200 2.00 40 1996 1.11 Hard
-25.40 155 185 3.00 60 2056 1.94 Hard
-25.60 190 200 1.00 20 2076 0.53 Hard
-25.80 190 210 2.00 40 2116 1.05 Hard
-26.00 225 250 2.50 50 2166 1.11 Hard -26 -26 -26
-26.20 250 251 0.10 2 2168 Hard
STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton
petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S-2
Location Palm Spring PIK 2 GL -
Tested by 0 - GWL - 6.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 0 Date of Test 14 April 2023

qc (cone Resistance) Total Friction (Tf) kg/cm friction ratio (fs/qc) (%)
0 50 100 150 200 250 300 0 500 1000 1500 2000 2500 0 2 4 6 8 10 12
0.0 0.0 0.0

-1.0 -1.0 -1.0

-2.0 -2.0 -2.0

-3.0 -3.0 -3.0

-4.0 -4.0 -4.0

-5.0 -5.0 -5.0

-6.0 -6.0 -6.0

-7.0 -7.0 -7.0

-8.0 -8.0 -8.0

-9.0 -9.0 -9.0

-10.0 -10.0 -10.0

-11.0 -11.0 -11.0

Depth (m)
Depth (m)
Depth (m)

-12.0 -12.0 -12.0

-13.0 -13.0 -13.0

-14.0 -14.0 -14.0

-15.0 -15.0 -15.0

-16.0 -16.0 -16.0

-17.0 -17.0 -17.0

-18.0 -18.0 -18.0

-19.0 -19.0 -19.0

-20.0 -20.0 -20.0

-21.0 -21.0 -21.0

-22.0 -22.0 -22.0

-23.0 -23.0 -23.0

-24.0 -24.0 -24.0

-25.0 -25.0 -25.0

-26.0 -26.0 -26.0

-27.0 -27.0 -27.0

-28.0 -28.0 -28.0

-29.0 -29.0 -29.0

-30.0 -30.0 -30.0

You might also like