You are on page 1of 1

Test Package List for SKPP Scope for Pipeline K-block system in Turkey

Test Package Design Operating Operating Isolation NDT


No Service Line Number From To Design Pressure Insulation Materials
number Temperature Temperature Pressure thickness requirement
1 Two Phase Two Phase line TP-K101-20"-L1A-H TP-K302/K202-16"-L1A-H K1-SEP-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
HP-K101-16"-L1A-H K1-SEP-001 K1-SCR-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
HP-K102-16"-L1A-H K1-SCR-001 KS-3000 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
HP Steam Line VT-K103-12"-L2A-H HP-K102-16"-L1A-H K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
2 Steam Line
VT-K104-12"-L2A-H HP-K102-16"-L1A-H K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
VT-K105-12"-L2A-H HP-K102-16"-L1A-H K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
LP Steam line LP-K601-32"-L1A-H KS-3000 K1-SIL-001 194 ℃ 13.8 bar 87℃ 1 bar 75mm 100% RT Rockwool
VT-K101-32"-L2A-H K1-SEP-001 K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
VT-K102-3"-L2A-H K1-SCR-001 K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
DRA-K101-8"-L1S-P K1-SEP-001 K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
DRA-K102-6"-L1S-P K1-SCR-001 K1-SIL-001 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
BR-K101-20"-L1A-H K1-SEP-001 BR-K102/K105-20"-L1A-H 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
BR-K102-20"-L1A-H BR-K101-20"-L1A-H K1-PUM-001A 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
BR-K105-20"-L1A-H BR-K101-20"-L1A-H K1-PUM-001B 194 ℃ 13.8 bar 157℃ 9 bar 75mm 100% RT Rockwool
BR-K103-16"-L1A-H K1-PUM-001A BR-K109-16"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
3 Hot Brine Hot Brine
BR-K106-16"-L1A-H K1-PUM-001B BR-K109-16"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K104-8"-L1A-H BR-K103-16"-L1A-H BR-K108-8"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K107-8"-L1A-H BR-K106-16"-L1A-H BR-K108-8"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K108-8"-L1A-H BR-K104/7-8"-L1A-H K1-SEP-001 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K109-16"-L1A-H BR-K103/6-16"-L1A-H BR-K601-16"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K601-16"-L1A-H BR-K109-16"-L1A-H KE-10300 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K602-16"-L1A-H BR-K601-16"-L1A-H BR-K603-16"-L1A-H 194 ℃ 20 bar 153℃ 11 bar 75mm 100% RT Rockwool
BR-K603-16"-L1A-H KE-10300 K1-PUM-002A/B 194 ℃ 20 bar 72.96℃ 9.8 bar 75mm 100% RT Rockwool
Reinjections
4 Reinjection line BR-K604-16"-M1A-H K1-PUM-002A/B BR-K401/K501-12"-M1A-H 194 ℃ 45 bar 72.96℃ 40 bar 75mm 100% RT Rockwool
line
SW-K801-3-L1S K8-WT-001 K8-PUM-101A/B/C 50 ℃ 10 bar NT NR 75mm 100% RT Rockwool
5 SEAL WATER SEAL WATER SW-K802-3-L1S K8-PUM-101A/B/C SW-K803-3-L1S 50 ℃ 25 bar NT 16 bar 75mm 100% RT Rockwool
SW-K803-3-L1S SW-K802-3-L1S 用水点 50 ℃ 25 bar NT 16 bar N/A 10 % RT N/A
6 IA IA ALL SYSTEM N/A 10 % RT N/A