Main Features

• Excellent industrial design brings pleasant user experience.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, RS485.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 7.4kW/32A max.

Input/Output Voltage Rating 230Vac±10%, Single phase, 50/60Hz, L+N+PE

Grid Type TN-S, TN-C, TN-C-S, TT

Configuration 01: 1 x IEC 62196-2 Type 2 tethered plug (Case C)


Charging Interface
Configuration 02: 1 x IEC 62196-2 Type 2 socket (Case B)

Metering Onboard metering chip or MID meter (optional), Accuracy: Class 1

Internal RCD 6mA DC

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Ground
Protection
fault, Integrated surge protection

User Interface

Display & Support Languages No display

Status Indication LED ring

Button and Switch Emergency button (Optional) and DIP switch inside (Used for setting output current limitation)

User Authentication RFID card, App, Credit card (optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092 (optional), IEC/ISO 15693 (optional)

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) Control pilot, ISO 15118 (optional)

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54@Case B, IP55@Case C

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m

Dimensions (WxHxD) 282*409*148 mm

Weight Approx. 4.4kg

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, TR25

Note: Pictures are for reference only, please prevail in kind.


Aurora 11
Main Features

• Excellent industrial design brings pleasant user experience.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, RS485.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 11kW/16A max.

Input/Output Voltage Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Grid Type TN-S, TN-C, TN-C-S, TT

Configuration 01: 1 x IEC 62196-2 Type 2 tethered plug (Case C)


Charging Interface
Configuration 02: 1 x IEC 62196-2 Type 2 socket (Case B)

Metering Onboard metering chip or MID meter (optional), Accuracy: Class 1

Internal RCD 6mA DC

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Ground
Protection
fault, Integrated surge protection

User Interface

Display & Support Languages No display

Status Indication LED ring

Button and Switch Emergency button (Optional) and DIP switch inside (Used for setting output current limitation)

User Authentication RFID card, App, Credit card (optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092 (optional), IEC/ISO 15693 (optional)

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) Control pilot, ISO 15118 (optional)

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54@Case B, IP55@Case C

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m

Dimensions (WxHxD) 282*409*148 mm

Weight Approx. 5.6kg

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, TR25

Note: Pictures are for reference only, please prevail in kind.


Aurora 22
Main Features

• Excellent industrial design brings pleasant user experience.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, RS485.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 22kW/32A max.

Input/Output Voltage Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Grid Type TN-S, TN-C, TN-C-S, TT


Configuration 01: 1 x IEC 62196-2 Type 2 tethered plug (Case C)
Charging Interface Configuration 02: 1 x IEC 62196-2 Type 2 socket (Case B)
Configuration 03: 1 x French shutter
Metering Onboard metering chip or MID meter (optional), Accuracy: Class 1

Internal RCD 6mA DC

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Ground
Protection
fault, Integrated surge protection

User Interface

Display & Support Languages No display

Status Indication LED ring

Button and Switch Emergency button(Optional) and DIP switch inside (Used for setting output current limitation)

User Authentication RFID card, App

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Bluetooth 5.0 Yes

Protocol (EVSE&EV) Control pilot

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 80℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54@Case B, IP55@Case C

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m

Dimensions (WxHxD) 282*409*148 mm

Weight Approx. 7.5kg(Including cable)

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Artemis 7
Main Features
• Excellent industrial design brings pleasant user experience.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, RS485.

• Could connect to StarCharge PeakController(optional accessories) via ethernet to


realize local dynamic load management.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 7kW/32A max.

Input/Output Voltage Rating 176~264Vac, single phase, 45~65Hz, L+N+PE

Grid Type TN-C-S, TT, IT

Charging Interface IEC 62196-2 Type 2 tethered plug (Case C)

Metering Onboard metering chip, Accuracy: 1%

Internal RCD 6mA DC

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Integrated
Protection
surge protection

User Interface

Display & Support Languages No display

Status Indication LED indicator

Configuration 01: Plug & Charge without authorization


User Authentication
Configuration 02: Plug & Charge without authorization, RFID card, App

Configuration 01: None


RFID Reader
Configuration 02: ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Configuration 01: RS485


Network Interface
Configuration 02: 4G, Wifi, Ethernet, RS485, Bluetooth 5.0

Configuration 01: None


Protocol (EVSE&Backend)
Configuration 02: OCPP1.6J

Protocol (EVSE&EV) Control pilot

Environmental

Operating Temperature -30℃ to 55℃

Storage Temperature -40℃ to 85℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m or 7m

Dimensions (WxHxD) 280*280*148 mm

Weight Approx. 3.75kg

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE/CB

Note: Pictures are for reference only, please prevail in kind.


Artemis 11
Main Features
• Excellent industrial design brings pleasant user experience.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, RS485.

• Could connect to StarCharge PeakController(optional accessories) via ethernet to realize


local dynamic load management.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 11kW (3.5kW single phase)/16A max.

176~264Vac, Single phase, 45~65Hz, L+N+PE


Input/Output Voltage Rating
373~457Vac, 3 phases, 45~65Hz, L1+L2+L3+N+PE

Grid Type TN-C-S, TT, IT (L1+L2 240Vac-single phase input)

Charging Interface IEC 62196-2 Type 2 tethered plug (Case C)

Metering Onboard metering chip, Accuracy: 1%

Internal RCD 6mA DC

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Integrated
Protection
surge protection

User Interface

Display & Support Languages No display

Status Indication LED indicator

Configuration 01: Plug & Charge without authorization, RFID card(Optional), Bluetooth(Optional)
User Authentication
Configuration 02: Plug & Charge without authorization, RFID card, Bluetooth, App

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Configuration 01: RS485


Network Interface
Configuration 02: 4G, Wifi, Ethernet, RS485, Bluetooth

Configuration 01: None


Protocol (EVSE&Backend)
Configuration 02: OCPP1.6J

Protocol (EVSE&EV) Control pilot

Environmental

Operating Temperature -30℃ to 55℃

Storage Temperature -40℃ to 85℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m or 7m

Dimensions (WxHxD) 280*280*148 mm

Weight Approx. 3.75kg

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE
Note: Pictures are for reference only, please prevail in kind.
Saturn 22
Main Features

• Excellent operation efficiency, dual 22 kW output.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet.

• Space-saving for flexible installation method.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)

Input/Output Power&Current Rating 2 x 22kW/2 x 32A max.

Input/Output Voltage Rating 400Vac±10%, 2*3 phases, 50/60Hz, L1+L2+L3+N+PE

Grid Type TN-S, TN-C, TN-C-S, TT

Configuration 01: 1 x IEC 62196-2 Type 2 tethered plug (Case C)


Charging Interface
Configuration 02: 1 x IEC 62196-2 Type 2 socket (Case B)

Metering MID meter, Accuracy: Class 1

Internal RCD Type B

Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Ground
Protection
fault, Integrated surge protection

User Interface

Display & Support Languages 4.3 inches screen

Status Indication LED strip

Button and Switch DIP switch inside (Used for setting output current limitation)

User Authentication RFID card, App, Credit card (optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) Control pilot (default), ISO 15118 (optional)

Environmental

Operating Temperature -25℃ to 45℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54@Case B, IP55@Case C

IK Rating IK10

Cooling Natural cooling

Charging Cable Length 5m

Dimensions (WxHxD) 395*504*197mm

Weight Approx. 11kg (Case B) Approx.16kg (Case C)

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Telesto 22
Main Features

• Excellent operation efficiency, dual 22 kW output.

• Connect to any backend based on OCPP 1.6J protocol.

• Support 4G, WIFI, Ethernet, Bluetooth.

Specifications

General Information

Charging Mode Mode 3 (IEC 61851-1)


Input/Output Power&Current Rating 2 x 22kW/2 x 32A max.
Input/Output Voltage Rating 400Vac±10%, 2*3 phases, 50/60Hz, L1+L2+L3+N+PE

Grid Type TT, TN, IT

Charging Interface IEC 62196-2 Type 2 socket (Case B)

Metering MID meter, Accuracy: Class 1

Internal RCD Type A 30mA AC + 6mA DC


Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature,
Protection
Ground fault, Integrated surge protection

User Interface

Display & Support Languages 7 inches non-touchable screen/7 inches touch screen(Optional)

Status Indication LED strip

Button and Switch DIP switch inside (Used for setting output current limitation)

User Authentication RFID card, App, Credit Card

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet, Bluetooth

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) Control pilot (default), ISO 15118 (optional)

Environmental

Operating Temperature -30℃ to 55℃


Storage Temperature -40℃ to 85℃
Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Natural cooling

Dimensions (WxHxD) 472.5*262*1418mm

Weight <25kg

Installation Floor mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, UKCA

Note: Pictures are for reference only, please prevail in kind.


Venus 30
Main Features

• Over 94% peak efficiency & 80A high output current.

• 7 inches LCD touch panel & RFID card reader.

• Connect to any backend based on OCPP 1.6J protocol.

• Robust all-weather enclosure for indoor and outdoor use.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Interface 1 x CCS2

Output Power 30kW max.

Output Voltage 200-1000Vdc

Output Current 80A max.

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency button

User Authentication RFID card, App, Credit card(Optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Charging Cable Length 3.4m

Dimensions (WxHxD) 680*440*280mm

Weight Approx. 35kg (excluding power modules)

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, TR25

Note: Pictures are for reference only, please prevail in kind.


Athena 60
Main Features

• Over 94% peak efficiency & 200A high output current.

• Installation space-saving: support wall-mounted installation, only


350mm thickness of the wall box.

• Connect to any backend based on OCPP 1.6J protocol.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE (No neutral line for IT system)

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT, IT

Output Interface CCS2+CCS2 or CCS2+CHAdeMO

Output Power 60kW max.

Output Voltage 200-1000Vdc


Output Current CCS2: 200A max./connector, CHAdeMO: 125A max./connector

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Mechanical Buttons & Emergency Button

User Authentication RFID card, App, Credit card (optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Charging Cable Length 4.5m

Dimensions (WxHxD) 750*750*350mm

Weight Approx. 95kg (including power modules)

Installation Wall mounting, Pole mounting (Pole is optional)

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Jupiter 60
Main Features

• Over 94% peak efficiency.

• High compatibility with CCS2/CHAdeMO/Type2.

• Connect to any backend based on OCPP 1.6J protocol.

• Robust all-weather enclosure for indoor and outdoor use.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Interface CCS2+CHAdeMO+Type2 (Plug)

Output Power DC 60kW max. + AC 22kW max.

Output Voltage CCS2: 150-550Vdc, CHAdeMO: 150-500Vdc, Type2: 400Vac±10%

Output Current CCS2: 125A max., CHAdeMO: 125A max., Type2: 32A max.

Charging Mode CCS2&Type2 or CHAdeMO&Type2 could be used at the same time.

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118, CHAdeMO 1.0

Environmental

Operating Temperature -30℃ to 55℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54

IK Rating IK08

Cooling Forced Air

Charging Cable Length 4m

Dimensions (WxHxD) 1018*1618*550mm

Weight Approx. 196kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, TR25

Note: Pictures are for reference only, please prevail in kind.


Jupiter 60 V2
Main Features

• Over 94% peak efficiency.

• High compatibility with CCS2/CHAdeMO/Type2.

• Connect to any backend based on OCPP 1.6J protocol.

• Robust all-weather enclosure for indoor and outdoor use.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Interface CCS2+CHAdeMO+Type2 (Socket)

Output Power DC 60kW max. + AC 22kW max.

Output Voltage CCS2: 150-550Vdc, CHAdeMO: 150-500Vdc, Type2: 400Vac±10%

Output Current CCS2: 125A max., CHAdeMO: 125A max., Type2: 32A max.

Charging Mode CCS2&Type2 or CHAdeMO&Type2 could be used at the same time.

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118, CHAdeMO 1.0

Environmental

Operating Temperature -30℃ to 55℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54

IK Rating IK08

Cooling Forced Air

Charging Cable Length 5m(Type2 is socket)

Dimensions (WxHxD) 1018*1618*550mm

Weight Approx. 296kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Jupiter 60 V2.5 (APAC Market Only)
Main Features
• Support CCS2+CCS2 simultaneous charging.

• 200-1000Vdc wide output voltage range.

• Connect any backend based on OCPP 1.6J protocol.

• Robust all-weather enclosure for indoor and outdoor use.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Interface 2 x CCS2

Output Power DC 60kW max.

Output Voltage CCS2: 200-1000Vdc

Output Current CCS2: 125A max.

Charging Mode Support 2 x CCS2 simultaneous charging.

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Environmental

Operating Temperature -30 to 50℃

Storage Temperature -40 to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP54

IK Rating IK10

Cooling Forced Air

Charging Cable Length 5m

Dimensions (HxWxD) 1600x860x550mm

Weight Approx. 200kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Jupiter 60 V3
Main Features
• Support CCS2+CCS2+Type2 simultaneous charging.

• Equipped cable management system.

• Connect any backend based on OCPP 1.6J protocol.

• Robust all-weather enclosure for indoor and outdoor use.

Specifications

General Information

Input Rating 400Vac±10%, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT


Configuration1: 2 x CCS2 + Type2 (Socket)
Output Interface
Configuration2: CCS2 + CHAdeMO + Type2 (Socket)
Output Power DC 60kW max. + AC 22kW max.

Output Voltage CCS2: 150-1000Vdc, Type2: 400Vac±10%, CHAdeMO: 150Vdc-550Vdc

Output Current CCS2: 200A max./connector, Type2: 32A max, CHAdeMO: 125A max./connector

Charging Mode Support simultaneous charging for all connectors.

User Interface

Display 7 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Environmental

Operating Temperature -30 to 50℃

Storage Temperature -40 to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Charging Cable Length 5m


1894x1050x710mm (including cable management system)
Dimensions (HxWxD)
1650x700x457mm (excluding cable management system)
Weight* Approx. 200kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, CB, UKCA

Note: Pictures are for reference only, please prevail in kind.


* Means the parameter maybe changed later.
Titan 180 V2
Main Features
• Over 94% peak efficiency.

• 200-1000Vdc wide output voltage range.

• Flexible configuration, CCS2 and CHAdeMO optional.

• Smart load management.

• Connect to any backend based on OCPP 1.6J protocol.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Interface CCS2+CCS2 or CCS2+CHAdeMO

CCS2: 180kW max. (150kW max. & 120kW max. are optional)
Output Power
CHAdeMO: 62.5kW max.

Output Voltage CCS2: 200-1000Vdc, CHAdeMO: 200-500Vdc

Output Current CCS2: 200A max., CHAdeMO: 125A max.

User Interface

Display 10.4 inches touch screen

Support Language Simplified Chinese, English (Other languages available upon request)

Button and Switch Emergency button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118, CHAdeMO 1.0

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Charging Cable Length CCS2+CCS2 Version: 5m or 7m. CCS2+CHAdeMO Version: 4.5m

Dimensions (WxHxD) 800*2050*750mm (depth without connector holder)

Weight Approx. 320kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE, TR25

Note: Pictures are for reference only, please prevail in kind.


Titan 180 V3
Main Features
• 200-1000Vdc wide output voltage range.

• Flexible configuration, CCS2 and CHAdeMO optional.

• Cable management system and ADA compliance.

• Connect to any backend based on OCPP 1.6J protocol.

• Equipped with payment terminal.

Specifications

General Information

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE (No neutral line for IT system)

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT, IT

Output Interface CCS2+CCS2 or CCS2+CHAdeMO


CCS2: 180kW max. (150kW max. & 120kW max. are optional)
Output Power
CHAdeMO: 62.5kW max.
Output Voltage CCS2: 200-1000Vdc, CHAdeMO: 200-500Vdc

Output Current CCS2: 300A max., CHAdeMO: 125A max.

User Interface

Display 10.4 inches touch screen

Support Language Simplified Chinese, English (Other languages available upon request)

Button and Switch Emergency button

User Authentication RFID card, App, Credit card (optional)

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Communication

Network Interface 4G, Wifi, Ethernet

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN70121, ISO 15118

Environmental

Operating Temperature -30℃ to 50℃

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤2000m above sea level

Mechanical

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Charging Cable Length 5m or 7m

Dimensions (WxHxD) 800*2050*750mm (without connector holder and cable management system)

Weight Approx. 395kg (excluding power modules)

Installation Ground mounting

Certification and standards

Standards and compliance IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU

Certification CE

Note: Pictures are for reference only, please prevail in kind.


Nova HPC System
Main Features

• Max. 500A output current with liquid cooling system.

• Up to 360 kW output power per connector.

• 200-1000Vdc wide output voltage range.

• Great scalability, up to 6 charging points per power cabinet.

Specifications

User Unit

Rendering

Output Interface 1 x CCS2 2 x CCS2


Output Power 360kW max.

Output Voltage 200-1000Vdc

Output Current 500A max. 200A max./connector


Simultaneous Charging N/A Yes
Display 10.1 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Emergency Button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Network Interface 4G/Wifi for backend connection and Ethernet for Power Cabinet local connection

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Operating Temperature -30℃ to 55℃ (Derating over 50℃)

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level (Derating over 2000m)

IP Rating IP55

IK Rating IK10 (Screen is IK08)

Cooling Liquid Cooling Natural Cooling


Charging Cable Length Liquid cooling(4.5m)/Natural cooling(5m)

User unit: 725*2597*504mm (Footprint: 400*400mm)


User unit: 725*2597*504mm (Footprint:
Dimensions (WxHxD) Liquid cooling box: 533*878*375mm (Footprint:
400*400mm)
518*343mm)

User unit: approx. 175kg


Weight User unit: approx. 182kg
Liquid cooling box: approx. 62kg

Installation Ground mounting

Note: Pictures are for reference only, please prevail in kind.


Nova HPC System

Power Cabinet

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT

Output Power 360kW max.

Output Voltage 200-1000Vdc

Output Current 500A max./Channel

Output Channel 6 Channels max.

Button and Switch Emergency Button

Network Interface Ethernet to User Unit

Operating Temperature -30℃ to 55℃ (Derating over 50℃)

Storage Temperature -40℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level (Derating over 2000m)

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Dimensions (WxHxD) 1564*2046*1176mm

Weight Approx. 840kg (excluding power modules )

Installation Ground mounting

Certificate CE

Dimensions

725mm
Depth: 1176mm

1564mm
2597mm

2046mm

Depth: 375mm

535mm
878mm
Neptune HPC System
Main Features
• Max. 500A output current with liquid cooling system.

• Up to 360 kW output power per connector.

• 200-1000Vdc wide output voltage range.

• Great scalability, up to 2 charging points per power cabinet.

• Support multiple cabinets connected together.

Specifications

User Unit

Rendering

Power Input 170-264Vac, single-Phase, 50/60 Hz, L+N+PE

Output Interface 1 x CCS2 CCS2 + CHAdeMO 2 x CCS2


CCS:360kW max.
Output Power 360kW max. 360kW max.
CHAdeMO: 200kW max.
Output Voltage 200-1000Vdc 200-1000Vdc 200-1000Vdc
CCS:500A max.
Output Current 500A max. 500A max./connector
CHAdeMO: 200A max.
Simultaneous Charging N/A Yes Yes/(400A/connector*2)

Meter CE meter CE meter PTB meter

Display 10.1 inches touch screen

Support Language English (Other languages available upon request)

Button and Switch Mechanical Buttons & Emergency Button

RFID Reader ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693

Network Interface 4G/Wifi for backend connection and Ethernet for Power Cabinet local connection

Protocol (EVSE&Backend) OCPP 1.6J

Protocol (EVSE&EV) DIN 70121, ISO 15118

Operating Temperature -30℃ to 55℃ (Derating over 50℃)

Storage Temperature -30℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level (Derating over 2000m)

IP Rating IP55

IK Rating IK10 (Screen is IK08)

Cooling Liquid Cooling

Charging Cable Length 4.5m


620*2000*450mm (without cable management system)
Dimensions (WxHxD)
950*2000*450mm (with dual cable management system)
Weight Approx. 240Kg Approx. 262Kg Approx. 262Kg
Installation Ground mounting

Note: Pictures are for reference only, please prevail in kind.


Neptune HPC System

Power Cabinet

Input Rating 400Vac±10%, 3 phases, 50/60Hz, L1+L2+L3+N+PE (No neutral line for IT system)

Power Factor ≥0.98 @ Full Load

Efficiency ≥94% @ Full Load (Peak)

Grid Type TN-S, TN-C, TN-C-S, TT, IT

Output Power 360kW max.

Output Voltage 200-1000Vdc

Output Current 500A max./Channel

Output Channel 2 Channels max.

Button and Switch Emergency Button

Network Interface Ethernet to User Unit

Operating Temperature -30℃ to 55℃ (Derating over 50℃)

Storage Temperature -30℃ to 70℃

Humidity 5% to 95% no condensation

Altitude ≤3000m above sea level (Derating over 2000m)

IP Rating IP55

IK Rating IK10

Cooling Forced Air

Dimensions (WxHxD) 1050*2050*750mm

Weight Approx. 350kg (Without power modules)

Installation Ground mounting

Certificate CE

Dimensions
Depth: 750mm
Depth: 450mm

950mm 2100mm

620mm 1050mm
2597mm

2050mm

You might also like