Siemens Syngo Datasheet (Application)
syngo.via
Software Version VB40A
siemens-healthineers.com/syngo.via
syngo.via · Software Version VB40A
Contents
Introduction 3
System Overview 4
syngo.via Clinical Packages and Applications 6
Multi-modality Routine Packages 7
Computed Tomography 10
Dual Energy Applications 17
Magnetic Resonance 18
Molecular Imaging 27
Mammography Applications 36
Multi-modality for Radiation Oncology 38
Licensing and Server Grades 40
Network Requirements 42
syngo.via Clients 43
Implementation Packages 45
Roles and Responsibilities 47
Connectivity and Standards Compliance 49
System Security and Data Protection 50
IT Care Plan 51
Education Plans 53
Siemens Healthineers Integration Solutions 54
Mapping Table Medical Devices to Applications 55
2
syngo.via · Software Version VB40A
Introduction
Let’s advance the digitalization of healthcare with Simplifying Routine
syngo.via
syngo.via makes many of your daily tasks more fluent:
As an intelligent, integrated imaging software, syngo.via1 It provides intelligent tools for an easier and more
helps you address and overcome issues from increasing productive diagnostic workflow. With its fast, reliable,
pressure and workload in radiology. and seamless performance across modalities, you can
read and report with ease and confidence. syngo.via
It offers multi-modality reading and fast 3D results to
enables actionable results that are accessible for better
speed up and enhance daily routine. We provide the
care delivery, whatever challenges your clinical environ-
latest innovations and AI-enabled features that take your
ment may bring.
reading and report creation to the next level. syngo.via
offers powerful tools and actionable results that are Empowering Innovation
accessible for better care delivery. syngo.via is more
Clinical progress never stops, and syngo.via is always up
than just a software: It brings the flexibility to adapt to
to date, applying the latest technologies like AI to help
your work style – and the power to advance your clinical
boost your diagnostic performance. As an open platform,
decision-making. It is the definition of “reading as it
syngo.via allows you to easily integrate your choice of
should be”.
apps and research prototypes, thereby enabling you to
pioneer new practices.
Adapting to you
3
syngo.via · Software Version VB40A
System Overview
1
The version and hotfix level of server and syngo.via client must match.
2
PACS must be able to support storing and retrieving DICOM encapsulated PDF objects.
3
Please contact your local sales representative for further information on availability in your region, technical requirements, and limitations.
4
syngo.via · Software Version VB40A
1
Some features are available with optional license only.
5
syngo.via · Software Version VB40A
All grades offer a wide range of multi-modality 3D Application packages are available for clinical specialties,
reading capabilities to support the basic needs of image for entire modalities or all-in enterprise access2. For
processing and reading. A broad variety of clinical dedicated clinical use cases individual applications can
applications are available for syngo.via to extend it for be obtained.
Acute Care
Acute Care
CT
Automate
Mobile
Multi-modality and Reporting Connect
Viewing
Routine
1
Medical Devices in their own right.
2
All-in modality and all-in enterprise packages are exclusively available as subscription offering. In general, 3rd party contents are not included in the subscription
packages. Exception: Breast Care contains MeVis license.
6
syngo.via · Software Version VB40A
syngo.via multi-modality • Report templates and • Easy access to 2D and • HL7 Patient Information
software foundation editor rendered image data Reconciliation (PIR) for
Dedicated workflows for • Findings infrastructure through web browsers data consistency with
multi-modality, CT Cardiac, and mobile devices e.g., RIS, HIS.
• Report customization
CT Vascular, CT Dual and advanced report • HL7 based Report
Energy1, PET&CT Oncology, template management export to connected
MR Reading information system
• HL7 based report export
Tools and technologies:
• Integrated diagnostic
• syngo.via Cinematic VRT guidelines for TNM
• syngo.via OpenApps2 staging, Lung RADS,
• Interactive Spectral CAD RADS, LI RADS
Imaging3
• syngo.via Time Curve Tool
• syngo.via CT Lung
Change
• syngo.via Basic Onco Tool
• syngo.MR Composer
• ALPHA Technology4
• Rapid Results Technology
for ALPHA
1
syngo.CT Dual Energy includes Monoenergetic, Optimum Contrast and syngo.CT DE Rho/Z
2
syngo.via OpenApps is not yet commercially available in all countries. Due to regulatory reasons, its future availability cannot be guaranteed.
Please contact your local Siemens Healthineers organization for further information.
3
Interactive Spectral Imaging allows change of Monoenergetic Plus keV levels right within syngo MM Reading as well as visualizing non-editable iodine maps,
Mixed and Virtual Unenhanced images (VNC).
4
Automated and standardized reconstructions; one-click segmentation of heart, lung, aorta; Anatomical Range Presets; AutoView with one-click access to the right
anatomical view; CT and MR presets for auto ranges (musculoskeletal, cardio-vascular, body regions, organs)
7
syngo.via · Software Version VB40A
8
syngo.via · Software Version VB40A
• Reporting package providing syngo.via WebViewer1 is the The package ensures that the
out-of-the-box report templates mobile extension of syngo.via patient data between syngo.via
and editor capabilities and an existing information system
syngo.via WebViewer is a client
• Report creation with predefined are consistent, and that the report
server product that provides access
report templates and automatic can be transferred to a connected
to rendered medical image data
population of image based system.
through web browsers and mobile
findings for structured and devices. Following HL7 interface
free-text reporting functionalities are supported:
It provides fast and easy image
• Customized creation of reports
access in time-critical situations HL7 Patient Information
with advanced report template
or on-call for physicians outside Reconciliation (PIR) messages A08,
management and editor
the radiology department (e.g., A34, and A40 (receiving patient
capabilities also enabling
for surgeons in trauma cases or update information from, e.g.,
structured data entry
neurosurgeon in stroke cases). RIS, HIS).
• Automatic population in HL7
based report export The flexible image access through Report Export License enhances
mobile devices also makes it possible the HL7 interface by the CDA
• Efficient and structured
to illustrate and discuss results (Clinical Document Architecture)
communication of syngo.via
directly with the patient. Level 3 standard, pdf content.
results into a diagnostic report
as Text, HTML and RTF, into file syngo.via WebViewer supports the
system as DOCX and PDF, into following image and file formats
PACS as DICOM SC and as DICOM (2D images as well as volumetric
encapsulated PDF data): Computed Tomography (CT),
• Evidence-based, structured Magnetic Resonance (MR), Positron
reporting with integrated Emission Tomography (PET, PET/CT),
diagnostic guidelines for TNM Computed Radiography/Digital
staging, Lung RADS, CAD RADS, Radiography (CR/DR), Secondary
LI RADS Capture Images (SC), Encapsulated
PDF Configuration
• Cross workflow reporting to
combine results in one document syngo.via WebViewer is available for
syngo.via Workstation and syngo.via
Departmental (L-and XL) in two
different deployments: integrated
and/or dedicated server. The
integrated deployment supports
a maximum of 3 concurrent
WebViewer users.
The dedicated server deployment
supports up to 19 concurrent
WebViewer users. Please contact
your sales representative for further
information.
1
The application syngo.via WebViewer is not for diagnostic viewing/reading on mobile devices in the US. Please refer to your sales representative whether the
product is available for your country. Diagnostic reading of images with a web browser requires a medical grade monitor. For iPhone and iPad country-specific laws
may apply. Please refer to these laws before using for diagnostic reading/viewing. For Japan: Applications on iPhone/iPad/iPod are not a medical device in Japan. Use
at your own risk. They are not intended to be used for diagnosis.
9
syngo.via · Software Version VB40A
Computed Tomography
Better understand diseases and make the right treatment decisions – with disease-specific software applications
complementary to your CT. Continuously enhance your clinical capabilities by providing better diagnostic confidence.
Improve process efficiency by saving working steps and make your entire patient pathway even faster.
syngo.CT CaScoring syngo.CT ASPECTS1 syngo.CT Cardiac syngo.CT ASPECTS1 syngo.CT Body
syngo.CT syngo.CT Bone Function syngo.CT DE Bone Perfusion
Colonography Reading syngo.CT Cardiac Marrow syngo.CT Bone
syngo.CT DE Calculi syngo.CT Coronary Function- syngo.CT DE Brain Reading
Characterization Analysis Enhancement Hemorrhage3 syngo.CT
syngo.CT DE Gout syngo.CT DE Bone syngo.CT Cardiac syngo.CT DE Direct Colonography
Marrow Function–Right Angio syngo.CT
syngo.CT DE
Ventricle Colonography–
Monoenergetic Plus syngo.CT DE Brain syngo.CT DE
Hemorrhage3 syngo.CT CaScoring Hardplaque Display Advanced
syngo.CT Dental
syngo.CT DE Direct syngo.CT Coronary syngo.CT DE syngo.CT
syngo.CT Neuro DSA
Angio Analysis Monoenergetic Plus Colonography-PEV
syngo.CT Vascular
syngo.CT DE Lung syngo.CT DE Direct syngo.CT syngo.CT DE
Analysis
Analysis Angio Dynamic Angio Monoenergetic Plus
1
Included in syngo.CT Neuro Perfusion
2
This feature is not commercially available in the U.S.
3
Not yet approved for USA.
10
syngo.via · Software Version VB40A
1
The usage of two monitors with maximal resolution of 3MP or one monitor in split screen mode with
maximal resolution of 6MP is mandatory in order to achieve reasonable performance.
2
This feature is not commercially available in the U.S.
3
Included in syngo.CT Neuro Perfusion.
11
syngo.via · Software Version VB40A
Computed Tomography
• Angio view
• VesselSURF for navigation along
coronaries
• Automatic coronary tracking and
labeling (RCA, LM, CX, major
coronary branches, and saphenous
vein grafts)
• Single-click stenosis measurement
• Single-click coronary vessel tracing
• Image sharpening for stent/
calcified lesion evaluation
• Rapid Results Technology for
automatic generation and
archiving of radial and parallel CPR
syngo.CT Vascular Analysis
(Curved Planar Reconstruction),
LAD, RCA, and CX.
• Export segmentation meshes syngo.CT DE Monoenergetic Plus syngo.CT Neuro Perfusion
as DICOM objects for third-party • Improved algorithm for enhanced • Tissue-at-risk model with
usage image quality and iodine contrast user-defined perfusion parameters
• Cinematic VRT (CRT) Cinematic • Evaluation of multiple ROI (e.g., CBF, SBV, TTD, TTS, TTP,
Rendering for high resolution MTT, Tmax, rCBF)
photorealistic 3D views of the syngo.CT DE Virtual Unenhanced
• Calculation of perfusion
heart • Iodine uptake quantification parameters based on two different
syngo.CT DE Bone Marrow • Calculation of virtual unenhanced perfusion models
image • Rapid Results Technology for
• Color-coding of bone marrow
• Calculation of fat map in the liver standardized and automated
• Evaluation of diffuse tumor perfusion results creation and
infiltrations syngo.CT Dynamic Angio archiving
syngo.CT DE Brain Hemorrhage1 • Time resolved CT images • Multi-parameter view
reconstructed from dynamic • Allows time point and volume
• Iodine uptake quantification
CT data navigation
• Differentiate hemorrhage from
• Visualization of the vessel • Dedicated Motion Correction
contrast agent
enhancement over time
• 4D noise reduction
syngo.CT DE Direct Angio • Visual inspection of time
• Bone removal
• Highlighting of bone structures attenuation curves
• Statistical ROI analysis
• Subtract bones by a single click syngo.CT Neuro DSA
• Data Export
syngo.CT DE Lung Analysis • Bone Removal • Reporting and Findings Handling
• Combination of syngo Lung PBV • Follow-up Workflow • Motion correction
and syngo Lung Vessels • Findings Navigator & Reporting • 4-step workflow available both
• Lung isolation • Workflow CT Neurovascular as guided or automated –
• Color-coding of affected vessels Auto Stroke
• Iodine uptake quantification
1
Not yet approved for USA.
12
syngo.via · Software Version VB40A
syngo.CT PE CAD1
• Export segmentation meshes • Single-click navigation to aortic • Rapid Result Technology for
as DICOM objects for third-party and mitral valve plane standardized and automated
usage • Cinematic VRT (CRT) Cinematic total CaScore result.
• Cinematic VRT: Cinematic Rendering for high resolution syngo.CT Coronary Analysis
Rendering for high resolution photorealistic 3D views of the
heart • Angio view
photorealistic 3D views of the
vessels • VesselSURF for navigation along
syngo.CT Cardiac Function –
coronaries
syngo.CT Vascular Analysis – Enhancement
• Automatic coronary tracking and
Autotracer • Visualization of first pass, Dual labeling (RCA, LM, CX, major
• Automatic tracking and labeling Energy, and dynamic myocardial coronary branches, and saphenous
of main vessels (zero-click) perfusion data vein grafts)
• AHA-conform 17-segment polar • Single-click stenosis measurement
maps for visualization of all types
• Single-click coronary vessel tracing
of myocardial perfusion data
1
This feature is not commercially available in the U.S.
13
syngo.via · Software Version VB40A
Computed Tomography
• Image sharpening for stent/ • Inputs of target volumes of • DE Direct Angio for bone and
calcified lesion evaluation interest (VOI) and volumetric Calcification Removal
• Rapid Results Technology for segmentation of myocardium • Bone & vessel isolation mode for
automatic generation and • Composite images allowing a selective highlighting of high
archiving of radial and parallel CPR merged display of an anatomical contrast structures
(Curved Planar Reconstruction), image with a color parameter • Rapid Results Technology for
LAD, RCA, and CX display in the target VOI automatic generation and
• Export segmentation meshes as • VOI and ROI (region of interest) archiving of radial and parallel CPR
DICOM objects for third-party measurement tools for a (Curved Planar Reconstruction)
usage detailed analysis of perfusion range series of aorta and left/right
• Cinematic VRT (CRT) Cinematic characteristics runoffs
Rendering for high resolution • Optimized color display of • Rapid Results Technology for
photorealistic 3D views of the perfusion parameter automatic generation and
heart • Assessment and quantification of archiving of bone and table
the perfusion of the myocardium removed VRT/MIP radial Ranges
syngo.CT DE Direct Angio
• Export segmentation meshes as
• Highlighting of bone structures syngo.CT PE CAD2
DICOM objects for third-party
• Subtract bones by a single click • Automated detection of filling usage
defects • Cinematic VRT: Cinematic
syngo.CT DE Hardplaque Display
• Overview layout Rendering for high resolution
• Differentiation of calcified plaque photorealistic 3D views of the
• Automatic lesion zoom view
and iodine contrast media with vessels
color-coding syngo.CT Rapid Stent Planning
syngo.CT Vascular Analysis –
syngo.CT DE Heart PBV • Automatic completion of Autotracer
manufacturer-specific graft
• Heart isolation • Automatic tracking and labeling
order forms
• Iodine uptake quantification of main vessels (zero-click)
syngo.CT TAVI Valve Pilot
• Virtual noncontrast display
Neurology CT Package
• Zero-click display of the aortic
syngo.CT DE Monoenergetic Plus
annulus plane based on aortic syngo.CT ASPECTS1
• Improved algorithm for enhanced valve hinge points
image quality and iodine contrast • Dedicated PACS-ready application
• All measurements for quantitative
automated through Rapid Results
• Evaluation of multiple ROI annulus assessment (annulus
Technology
area, annulus perimeter min.
syngo.CT Myocardial Perfusion
and max. diameters, effective syngo.CT DE Bone Marrow
• Intuitive visualization of diameters based on annulus
• Color-coding of bone marrow
time-variant multislice or area or perimeter) are ready for
volumetric data review as the case is opened • Evaluation of diffuse tumor
infiltrations
• Advanced motion correction for syngo.CT Vascular Analysis
improved anatomical alignment syngo.CT DE Brain Hemorrhage3
• Curved & cross-sectional ranges
• Fast simultaneous calculation of • Iodine uptake quantification
various volumetric perfusion • VesselSURF
• Differentiate hemorrhage from
parameter images • Vessel tracking (2-click centerline)
contrast agent
• Stenosis measurement
syngo.CT DE Direct Angio
• Single Energy Calcification
1
Included in syngo.CT Neuro Perfusion Removal • Highlights of bone structures
2
This feature is not commercially available in the U.S.
3
Not yet approved for USA. • Subtract bones by a single click
14
syngo.via · Software Version VB40A
15
syngo.via · Software Version VB40A
Computed Tomography
16
syngo.via · Software Version VB40A
SOMATOM go.Top
SOMATOM Force
SOMATOM Drive
Available
Available, but usage not recommended or meaningful
1 3
Optimum Contrast
Monoenergetic
Interactive Spectral Imaging 12
Recon & Go
Direct Angio
GO
Virtual Unenhanced10
Monoenergetic Plus
Mixed
Monoenergetic Plus (fixed keV levels)
FAST DE Results8
Optimum Contrast
Lung PBV
Virtual Unenhanced
Rho/Z6
Virtual Unenhanced – Liver VNC11
FAST DE9 C-image7 C-image7
1
Not yet approved for USA 7
C-type reconstruction is similar to FAST DE in terms of usage possibilities
2
With mandatory scan delay after injection of >75 s 8
FAST DE Results automatically generates Dual Energy datasets at the AWP
(no arterial phase, liver only) 9
FAST DE allows choosing the mixing ratio between low and high kV at the
3
Only for visualization of static iodine enhancement after interventional scanner for reconstructed mixed images that are directly send to PACS
procedures (not for CTA) 10
Including Liver VNC
4
Not for visualization of iodine, only for metal artifact reduction 11
Requires scanner version VB20. This software version is 510(k) pending
5
Mainly for visualization of iodine, basic metal artifact reduction 12
VNC not available for Dual Spiral Dual Energy
6
Not cleared for use as a basis for radiation therapy planning,
but for visualization only
17
syngo.via · Software Version VB40A
Magnetic Resonance
The MR applications and clinical packages make it easier to add advanced applications to clinical routine thanks
to the capability of syngo.via to take out the complexity of advanced post-processing.
Standardization of the results is improved through robust algorithms and user-defined automation of the
processing steps. Finally, communicating the results to the referring physician in a meaningful way is made
possible by structured reports following clinical recommendations.
1
This feature is still under development, and is not yet commercially available in the United States.
2
This feature is not commercially available in the U.S.
18
syngo.via · Software Version VB40A
1
Requires syngo.MR Neuro Perfusion.
2
Requires syngo.MR Neuro Perfusion Mismatch.
3
Requires syngo.MR 3D Lesion Segmentation.
4
This feature is still under development, and is not yet commercially available in the United States.
19
syngo.via · Software Version VB40A
Magnetic Resonance
MR Oncology Package
syngo.MR 3D Lesion Segmentation
• Semi-automated volumetric
evaluation of lesions
• Two possible modes: Box-based
and brush-based initialization of
segmentation
• Longest lesion diameter provided
• Correction tools
syngo.MR BreVis
1
This feature is still under development, and is not yet commercially available in the United States.
20
syngo.via · Software Version VB40A
templates
21
syngo.via · Software Version VB40A
Magnetic Resonance
MR Neurology Package
syngo.MR Brain Morphometry1
1
This feature is pending 510(k) clearance, and is not yet commercially available in the United States.
22
syngo.via · Software Version VB40A
23
syngo.via · Software Version VB40A
Magnetic Resonance
(gda format)
24
syngo.via · Software Version VB40A
MR Cardiovascular Package
syngo.MR Cardiac 4D Ventricular
Function
1
This feature is not commercially available in the U.S
25
syngo.via · Software Version VB40A
Magnetic Resonance
Single Applications
syngo.mMR General
26
syngo.via · Software Version VB40A
Molecular Imaging
syngo.MI Oncology
1
This feature is not commercially available in the U.S
27
syngo.via · Software Version VB40A
Molecular Imaging
1
All-in modality and all-in enterprise packages are exclusively available as
subscription offering. In general, 3rd party contents are not included in the
subscription packages. Exception: Breast Care contains MeVis license.
28
syngo.via · Software Version VB40A
syngo.MI Oncology
syngo.MM Multi-Timepoint Eval
syngo.MI Segmentation
1
Configuration of CT Clinical Packages can vary depending on CT scanner type.
2
Works with Dual Energy images from the whole SOMATOM Definition Family (Single Source and Dual Source Dual Energy).
syngo.CT DE Virtual Unenhanced for Single Source Dual Energy.
3
Requires at least one user license of syngo.CT DE Virtual Unenhanced.
29
syngo.via · Software Version VB40A
Molecular Imaging
1
This feature is not commercially available in the U.S.
30
syngo.via · Software Version VB40A
1
This feature is not commercially available in the U.S.
31
syngo.via · Software Version VB40A
Molecular Imaging
• Provides quality control and • Utilizes patient and dose specific • Manipulate and perform
organ-based processing activities information to evaluate many arithmetic on NM images such
different renal exams including: as curve interrogations, filtering,
Quality Control masking, adjusting matrices,
• MAG3
• Motion and quality evaluation addition, subtraction, scaled
• Lasix subtraction, multiplication,
through use of cinematic
images and a reference line that • Transplant division, geometric mean and
corresponds to a sinogram, • ltoh ERPF static merge
lingoram and summed image • Gates GFR
• Automatic and manual motion • Oberhausen
correction
• Oriuchi
• Review of gated histograms
• Bubeck
Organ-based Processing • Captopril Comparison
Enables the user to further evaluate • Available dose calibrator or syringe
specific organ systems with methods
automatic or manual region
of interest determinations • Yields detailed curve analysis and
results summary
Cardiac Planar Gated Blood Pool
32
syngo.via · Software Version VB40A
33
syngo.via · Software Version VB40A
Molecular Imaging
syngo.PET syngo.SPECT
Cardiology Cedars Cardiology Cedars
syngo.PET Cedars Suite syngo.SPECT Cedars Suite
• Cedars Cardiac Suite for PET MPI • Cedars Cardiac Suite for SPECT MPI
and LV function and LV function
• Generation of left ventricle inner • Generation of left ventricle inner
and outer surfaces and valve plane and outer surfaces and valve plane
from LV short axis perfusion PET from LV short axis perfusion SPECT
data with Rb82-Rubidium and data with Tc99m Mibi or Tl 201
NH3-Ammonia • Normals database comparison
• Normals database comparison • Generation of stress, rest,
• Generation of stress, rest, and and reversibility surfaces and
reversibility surfaces and 2D 2D polar maps
polar maps • Generation of segmental
• Generation of segmental perfusion scores
perfusion scores (17 and 20 model)
(17 and 20 model) • Computation of functional metrics
• Computation of functional metrics including LV EF volume/time, ED,
including LV EF volume/time, ED, ES, SV, EF, and Summed Motion
ES, SV, EF, and Summed Motion score
score • Phase Analysis
• Viability Quantification of • Quantitative Bloodpool
mismatch or scar between SPECT Analysis for left- and
perfusion and viability scans right-ventricular function
• Quantification of MBF and CFR • Planar Gated Bloodpool Analysis
for Rb82 and NH3-Ammonia
• NH3 residual activity correction
34
syngo.via · Software Version VB40A
• Viability Quantification of
mismatch or scar between
perfusion and viability scans
• Quantification of MBF and CFR
for Rb82 and NH3-Ammonia
• NH3 residual activity correction
35
syngo.via · Software Version VB40A
Mammography Applications
1
Optional
2
Availably with MAMMOMAT Revelation only.
36
syngo.via · Software Version VB40A
syngo.Breast Care Tomo1 syngo.Breast Care Link-it1 The following displays are
approved for diagnostic use for
• Fast Tomo Reading feature set • Interactive correlation of 2D and/
mammography: Eizo: 5 MP monitors:
with ReportFlow Movie link and or 3D anatomical areas
RX560, GX540. They can be
dedicated Tomo Slab layouts • Works for current and prior DICOM operated with the syngo.Breast Care
• Support for HD Tomo Biopsy and MG images of various vendors medical device in configuration of
InSpect datasets • Applies for tomosynthesis images up to 2 x 5 mega pixels, plus up
• Tomo slabbing with presets and together with syngo.Breast Care to 2 additional monitors of up to
shortcuts Tomo2 1536 x 2048 mega pixels.
• Dedicated layouts for Digital Breast syngo.Breast Care CAD Display1 Operating other monitors approved
Tomosynthesis (DBT) exams for mammography reading is
(DICOM CT, DICOM DBT) including • Displays 2D and 3D CAD markers
possible and lies within the
comparison with (current/prior) indicating calcifications and
customer‘s responsibility. Further
mammograms masses
details are described in the syngo.via
• All sizing modes and magnifying • Adds quantitative lesion Breast Care Workplace Datasheet.
functions available for information
tomosynthesis • Based on DICOM SR objects
• User-configurable workflow generated by various CAD systems
(ReportFlow®) including In combination with the software
tomosynthesis exams option syngo.Breast Care, the
• Marking and annotation tools display of mammography images for
including 3D diagnosis on syngo.via is possible,
as syngo.Breast Care is FDA-cleared
• Various scrolling tools by mouse,
for this purpose.
keypad, or automatic cine mode
• Synchronized scrolling through Following systems are validated for
datasets the use with syngo.Breast Care:
1
Optional
37
syngo.via · Software Version VB40A
Multi-modality support
4D features
1
Optional
38
syngo.via · Software Version VB40A
Contouring features
1
Optional.
2
Requires compatible laser systems.
39
syngo.via · Software Version VB40A
Licensing
1
kppy (kilo procedures/studies per year)
40
syngo.via · Software Version VB40A
The syngo.via software can be delivered with dedicated Hewlett Packard based Hardware grades or deployed and
operated in virtualized environments based on VMware and Hyper-V.
The Hewlett Packard based Hardware grades are designed to enable performant and reliable operations for the
available software grades with the below defined load profiles (number of concurrently rendered slices) and total
amount of slices stored in syngo.via short-term storage.
Server Virtualization
This option allows you to utilize own virtualized infrastructures, and this smoothly integrate syngo.via in the
existing IT Infrastructure2. For sizing orientation, find the below details oriented on the above load profiles.
It is recommended to enable GPU support, if latest NVIDIA vGPU technology OpenGL support and GRID cards are
available. nVidia vGPU support VMware features vMotion and snapshot with the new GPU-GRID card technology.
For more information, please contact your local sales representative on availability in your region, technical
requirements, and limitations.
Note:
• It is the operator’s responsibility to ensure that the license for the Microsoft Operating System (Windows Server)
running in the syngo.via virtual container complies with the Microsoft terms and conditions for operations in a
virtualized environment.
• Listed resource requirements are valid for virtualized environments. Installations on non-virtualized environments
are typically not supported. For more information please contact your local sales representative on availability in
your region.
1
Concurrent rendering of slices is based on 512 x 512-bit image matrix.
2
By default, syngo.via will compute software-based rendering using the CPU, which is sufficient for most syngo.via applications. Certain applications
require a physical Graphics Processing Unit (GPU) with unrestricted and dedicated access to run the imaging algorithms. GPU support should be enabled for the
following applications: syngo.CT Colon, syngo.CT Liver Analysis, syngo.MR Neuro fMRI, syngo.MR Neuro Tractography, syngo.MR Neuro 3D Engine, and syngo.MI
Neuro Hybrid 3D.
41
syngo.via · Software Version VB40A
Network Requirements
The server requires two static IP addresses, which must be provided by the customer. Please contact your sales
representative for further information.
Ports used by the system are listed in Product & Solution Security White Paper and MDS2 syngo.via.
As a faultless communication between syngo.via server and syngo.via client is crucial to the operability of
the system, a reliable and performant network is a precondition for a successful integration.
Minimum Recommended
Hospital internal Network 100 Mbit/s 1 Gbit/s
Connection
Remote Client Connection1 Download: 10 Mbit/s Download: 30 Mbit/s
Upload: 1.5 Mbit/s Upload: 2 Mbit/s
Latency: 20 ms–25 ms Latency: 10 ms
(sporadic use for viewing data (routine use in clinical routine)
remotely)
Software Updates Regular distribution of software
updates for higher system
performance and reliability
Transmission between server and client can be compressed depending on configuration profiles.
• The default setting for displaying images is lossless compression for the final displayed images on the monitor.
During image interaction, the images might be shown with a reduced resolution.
• The user is constantly informed about the current image quality.
1
Transmission between server and client can be compressed depending on configuration profiles. The default setting for displaying images is lossless compression
for the final displayed images on the monitor. During image interaction, the images might be shown with a reduced resolution. The user is constantly informed
about the current image quality.
42
syngo.via · Software Version VB40A
syngo.via Clients
Hardware and Software¹ and requires administrative rights on can download and install updates.
the client computer. Client Virtualization is also possible
The client software is delivered and
based on the following:
downloadable from the syngo.via The client software can be installed
Server. The Client SW needs to be and updated using the standard • VMWare Horizon (with View) 5.5,
installed on each client computer. Microsoft Windows installer. and higher
The client installation is in the • Citrix XenDesktop 7 or higher
The tools check for updated software
responsibility of the IT Administrator
versions on the syngo.via Server and
Note: If other software is running • Siemens Healthineers TeamViewer The following security settings
on the client, performance may be Repack must be enabled in Internet Explorer:
affected. • Apple OS X (Emulating Microsoft • File download
Software Requirements 2 Windows Operating Systems as • Active scripting (JavaScript)
listed above – using software like
• Microsoft Windows 7 SP1 • Submit non-encrypted form data
Parallels Desktop for Mac)
(Home Premium, Professional, • ActiveX controls and plug-ins
Ultimate, Enterprise), Microsoft The VC Runtime, the
Siemens Healthineers Repacks The required hardware for syngo.via
Windows 8.1 (Pro, Enterprise),
for TeamViewer, VNC, and the clients and servers may vary based
Microsoft Windows 10 (Home,
.NET framework are installed on specific needs and performance
Pro, Education, Enterprise)
automatically if they are not expectations.
• Microsoft VC8, VC10, VC12,
available on a client. The Media The minimum recommended
and VC14 Runtime
Player has to be installed manually hardware for syngo.MI Offline
• Microsoft .NET framework 4.7.2 by the user if screen captures and OncoBoard client:
or higher videos need to be replayed on the • IBM/PC compatible running
• Windows Media Player 9 or higher client. Administrative rights are Windows10 Pro 64-bit OS MUI
• Internet Explorer 113 required for all these installations.
• Intel Core i3 and 2.5 GHz clock
• Siemens Healthineers TeamViewer Note: The IT administrator should • Minimum of 6 GB of RAM
Connector Repack ensure that all syngo.via client
• Minimum of 1 GB of free
• Siemens Healthineers VNC Repack hardware drivers, especially the
disk space
GPU driver are up to date.
• Minimum screen resolution of
1366 x 768
• If using USB drives, minimum of
USB 3.0
1
The used hardware must follow IEC 60950-1/EN 60950-1.
2
64-bit operating systems are recommended.
3
Newer versions like Microsoft Edge can be used.
43
syngo.via · Software Version VB40A
The quality of displayed images is Printers and cameras used for The syngo.via server is delivered
highly dependent on the quality and diagnostic purposes must also with one instance of Microsoft
settings of the monitors, graphics fulfill minimum requirements. Windows Server 2016 Standard
cards, and graphics drivers that are Siemens Healthineers provides Edition. With each installation of
used. In the United States, monitors optional validation of the suitability the syngo.via client software, the
(displays) should not be used for of specific printers and cameras client computer or user has access
diagnosis, unless the monitor to be used for the diagnosis of to services of the Windows Server
(display) has specifically received radiological images. 2016 Standard Edition running on
510(k) clearance for this purpose. the syngo.via server.
In the United States, paper printouts
It is the customer’s responsibility
should not be used for diagnosis, To legally access this Windows Server
to ensure that client monitors are
unless the Post Script printer 2016 Standard Edition software,
compatible with graphic cards and
has specifically received 510(k) a Client Access License (CAL) is
graphic drivers.
clearance for this purpose. required. A CAL is not a software
It is also his/her responsibility to product; rather, it is a license that
use suitable monitors for diagnostic gives users the right to access the
purposes1. services of the server.
Implementation Packages
Clinical IT Infrastructures are diverse, which is why flexible software integration is key to an efficient reading
workflow. syngo.via can be implemented in various levels, depending on existing, surrounding software solutions,
desired data flow, and diagnostic processes.
Technical view of the syngo.via integration: • Direct Image Transfer • Smart Remote Services connection
• Thin Slices • Integration into clinical network
Thick slices
• Active Directory integration
• Basic installation and configuration
(Archiving, Pre-fetching, Workflow
mapping,...)
• Archiving and routing rules
• Integration of up to 5 DICOM nodes
• Pre-fetching of priors
• DICOM storage • DICOM routing
• DICOM storage commitment • syngo.via WebViewer integration
• DICOM query and retrieve
• One client installation
• Study Call-up4 from PACS³
• Study Call-up4 from RIS Worklist³
• DICOM Modality Worklist •P
atient Information • DICOM Modality Worklist Integration
•P re-fetching based on DICOM Reconciliation (PIR) (optional)
Modality Worklist (DMWL) •R
eport Export (optional)
1
As long as this is supported by the existing PACS.
2
Please contact your local sales representative for further information on availability in your region, technical requirements, and limitations.
3
PACS/RIS Vendor Support required. The PACS or RIS has to support starting an executable with the appropriate parameters. If this is not available,
it may be required to use the optional Desktop Connector to achieve this integration.
4
The PACS has to support starting an executable with the appropriate parameters. If this is not available, it may be required to use the optional 45
Desktop Connector to achieve this integration
syngo.via · Software Version VB40A
with one PACS or RIS workplace for image call-up directly This may require the purchase of additional
out of the PACS or RIS application user interface software and services from the PACS or RIS
X X
vendor8
Clients • Distribute the front-end integration to
• Assistance in setting up image call-up of syngo.via from additional PACS or RIS clients within the
the RIS user interface⁶ institution
Multi-server features (opt⁷)
• Support installation and configuration of the
• Multi-server License Sharing (MSL), Access (MSA), X X
servers in clinical network
Configuration (MSC)
DICOM Modality Worklist Integration
• Ensure that the DMWL-source can provide the
• Configuration of the DICOM Modality Worklist interface X
DMWL to syngo.via
from RIS to syngo.via⁶
Patient Information Reconciliation/PIR (opt⁷)
• Configure the sending application to send PIR
• Patient Data on RIS and syngo.via are automatically X
messages to syngo.via⁶
synchronized by PIR
Report Export (opt⁷) • The receiving application might require
• Enable context-specific reports created in syngo.via additional licenses for this connectivity to the
X
for export and sign-off in RIS syngo.via server. The customer is responsible
• Nuance PowerScribe 360 interfacing to clarify and order licenses if needed
approval
Project
1
If the customer does not provide SRS connectivity, additional professional services for implementation without SRS support are offered.
2
Server system must be installed with all connected DICOM nodes & clients inside the same LAN segment/subnet. Deployment across different LAN segments is not covered.
3
Please refer to the syngo.via Pre-installation Manual for virtual server installations.
4
Depending on local legal regulations, the monitor setup may allow viewing only (monitor calibration not included).
5
Each package covers a dedicated number of DICOM nodes & clients that will be connected. Please consider ordering additional services if further connections are required.
6
Purchase of software and services from the RIS vendor might be required.
7
Optional implementation package. Need to be ordered separately.
46 8
The PACS or RIS has to support starting an executable with the appropriate parameters. If this is not available, it may be required to use the optional
Desktop Connector to achieve this integration.
syngo.via · Software Version VB40A
syngo.via is based on a client-server architecture. Therefore, the integration into an existing IT architecture requires
IT administration. It is also necessary for the IT administrator to assist the implementation and maintenance of
syngo.via. Additionally, a customer clinical administrator (key user) is strongly recommended. The customer IT
administrator as well as the customer clinical administrator are appointed by the customer and have to be trained
by Siemens Healthineers.
IT Administrator
Archiving of audit trail logs using optical media or network shares weekly
(HIPAA Audit Controls, USA only)
Check the syngo.via server for available updates from the Software Catalog every three month
Installation of client software and prerequisites per client machine once and on demand
Data security and data protection (install, configure, and update firewalls, once and on demand
virus protection software, and Microsoft operating system hotfixes on clients
and servers)
Update of syngo.via server with Siemens Healthineers hotfixes and service packs from the Software Catalog
Update of syngo.via client BIOS, firmware, and drivers based on HW vendor instructions
License Management (import, check availability of syngo.via application licenses, assign to dedicated users or clients)
User Account and Role Management (manage domain and local user accounts using Active Directory and/or .NET SQL
Authorization Manager, assign roles to users and user groups using Windows Authorization Manager)
Provide help to clinical users regarding IT topics (use troubleshooting tools, escalate issues to the
Siemens Healthineers Customer Care, if required)
1
A secondary backup is a copy of the primary backup.
47
syngo.via · Software Version VB40A
Assist the hardware vendor during troubleshooting of hardware issues (provide access to server hardware and
diagnostic tool results)
Solve syngo.via server issues (syngo.via application server, operating system, and network)
Solve syngo.via client issues (user management, network, hardware, and operating system issues)
Clinical Administrator
Provide help to clinical users regarding application topics (use troubleshooting if required
tools, escalate issues to the Siemens Healthineers Customer Care)
Train clinical users in handling the syngo.via client (knowledge transfer on on demand
syngo.via applications to clinical users)
48
syngo.via · Software Version VB40A
Efficiency depends on how syngo.via provides functionality for HL7 messages are used to
workplaces are networked. syngo.via importing/exporting DICOM data communicate between syngo.via,
integrates imaging modalities and from/to CD/DVD, from/to local the RIS, and/or HIS (in case of no RIS)
IT, making it possible to access and network drives, and from/to to correct patient data and achieve
and share information with clinical configured DICOM nodes. a synchronized patient data set in
partners: these systems.
Image Archiving
• Front-end integration: syngo.via syngo.via supports the following
• syngo.via stores images and
provides a standard interface incoming HL7 messages:
changes in short-term storage
for image call-up from third-party
(STS). syngo.via can be configured • ADT A08 (patient record update)
RIS/PACS or HIS applications. This
to send images to the archive ADT A40 (patient record merge)
interface can be used to configure
immediately or based on specific • ADT A34 (patient record merge –
a third-party application to launch
rules. In syngo.via, archiving Patient ID only)
syngo.via with selected images
means sending DICOM objects to
• Data exchange: syngo.via uses All other not supported HL7
a DICOM node which has been
industry standards (DICOM and messages are silently discarded by
configured for archiving. DICOM
HL7) meaning it can connect to syngo.via.
objects comprise received DICOM
HIS/RIS, PACS, printers/cameras, objects and internally created ORU R01 messages are used to
and modalities, regardless of the DICOM objects. syngo.via itself export structured results to a
vendor does not provide equipment for connected information system.
• Siemens Healthineers integration archiving. syngo.via supports three formats:
solutions: Further synergies • To fit the capabilities of the ASCII Text, CDA Level 3, and PDF.
can be achieved by using existing archiving environment, For the HL7 conformance statement,
RIS/PACS and modalities syngo.via can be configured to see http://www.siemens.com/HL7.
from Siemens Healthineers wrap its DICOM result objects into
basic objects. Furthermore, Nuance PowerScribe 360
Hospital IT Infrastructure
syngo.via supports multiple The syngo.via report can be
syngo.via can be connected to the archives such as thin- and integrated into Nuance PowerScribe
hospital’s IT infrastructure, such thick-slice archives and allows it to 360 using the web service provided
as the hospital’s Active Directory, send results to different archives by PowerScribe 360.
DNS, and mail server. based on DICOM attributes such
as Referring Physician. File Drop Integration
IHE Profiles
DICOM Standard The syngo.via report can be exported
syngo.via is designed for back-end
to a fileshare as a .docx or PDF file
and front-end integration with DICOM is used for exchanging image for the exchange with information
Siemens Healthineers syngo data between syngo.via and systems.
applications, and with systems modalities (Siemens Healthineers
from different vendors. and third-party), DICOM nodes,
Communication is based on and the PACS.
the internationally recognized
workflow-supported profiles defined For the DICOM conformance
by the IHE Framework (Integrating statements, see:
the Healthcare Enterprise). https://www.siemens-healthineers.
com/services/it-standards/dicom
For the IHE profiles, see:
https://www.healthcare.siemens.
com/services/it-standards/ihe-
integrating-the-healthcare-enterprise
49
syngo.via · Software Version VB40A
Offering a secure solution is one Virus Protection We offer RAID solutions to protect
of our major goals. That is why we against the most common attacks,
Virus protection software from the
continue to improve the security such as cold boot attacks, malicious
following manufacturers is approved
for syngo.via in every version. code, and brute force attack. Hard-
for syngo.via:
To prevent data theft and keep up ware encryption uses dedicated
with changing security guidelines • Trend Micro OfficeScan physical processors located in the
of the authorities, we have • McAfee VirusScan Enterprise RAID controller device to encrypt and
increased the system protection decrypt the data in real time.
• Symantec Endpoint Protection
measures with VB40A.
• Sophos Endpoint Security and Backup / Restore
Data Protection Control syngo.via backup policy uses an
Legal Requirements Siemens Healthineers provides incremental backup scheme (daily).
information on recommended virus The backup includes system,
• Authorization required to access
protection software, and general application (including syngo.via
functions and data
instructions on configuration. configuration), and database
• Audit trails to record user and (patient and workflow) data.
system activities The customer is responsible for
syngo.via acts as short-term storage,
regularly updating virus patterns/
• Automatic termination of user therefore, it does not backup
definitions.
sessions after specific time-out the image data itself. Restore
• Archiving of images using System Hardening operations can be performed by
interface to existing PACS the IT administrator, for example
The medical industry is nowadays
recovery of corrupted files, recovery
• Secure data storage using RAID one of the most attacked industries
of a corrupted operating system,
short-term storage for images worldwide. System hardening is one
or recovery of applications. Restore
• Protection against malicious of the security measures to minimize
operations after database failures
software attacks the vulnerabilities of the system.
must be performed by
• Encryption of Client-Server The hardening is based on the Siemens Healthineers Service.
communication Secure Technical Implementation
Guides (STIG) which are developed
and maintained by Defense
Information System Agency
of the US.
50
syngo.via · Software Version VB40A
IT Care Plan
Investment in IT services’ requirements are, the IT Care Plan is The core elements of the IT Care
development and staff’s knowledge at hand. The comprehensive service Plan are Remote Technical Support,
is key to long-lasting business contract, customized for Healthcare Remote Application Support,
success. IT systems, is offered to institutions Software Updates, and Software
who choose syngo.via, the leading Upgrades. To help customers taking
The trend towards evidence-based
Healthcare 3D post-processing suite. the most out of the new software
medicine also requires the
functionalities, the IT Care Plan
decision-support features healthcare The contracts are customized to the
can be extended with Equipment
providers demand from their level of service that is appropriate
& Clinical Education and
healthcare IT systems. Whatever to your specific system and
PEPconnections.
your applications, workflow, or IT organization.
Empowered System
Users IT Care Plan
Availability
PEPconnections*
Equipment &
Clinical Education
Application Support
Technical Support
* Our optional premium service offering for
Personalized
Software Upgrades
the virtual education services to manage the
Software Updates healthcare institution’s performance growth
Experiences with integrated group management and
administration features.
Education Equipment & Tailored training to improve workflow productivity and diagnostic
Elements Clinical Education accuracy, adapted to the learning styles and needs of clinical staff.
51
syngo.via · Software Version VB40A
• Siemens Healthineers is the single All IT Care Plans require a connection The Administration Portal is part of
point of contact for the customer. to Smart Remote Services (SRS) the syngo.via server software and
Siemens Healthineers provides through VPN connection. enables the following administrative
support for the software as functions:
Pre-Condition
committed in the IT Care Plan. • Status control of server and
Hardware-related service requests Specification of minimum broadband components
will be routed to the responsible Internet connection in detail:
• Access to detailed status checks,
hardware provider. • Downstream: 2000 kBit/s for down to subprocesses and
• The customer administrator is the Software update, IT- and subcomponents
first contact person for internal Application support
• Color-coded overall system status
users and the single point of • Upstream: 512 kBit/s for
contact to Siemens Healthineers. • Statistical reports for continuous
Application support
monitoring of key performance
Therefore, the administrator is an • Upstream: 256 kBit/s for Software parameters
essential part of the service process. update and IT support
For more details regarding • Overview of active users
In case these minimum requirements
administrator tasks, please refer • Evaluation of centrally stored
are not fulfilled, certain services
to the current version of the system messages
may not be provided – like Remote
respective Administrator Manual. • Configuration of system,
Application Support – and the
Customer Benefits agreed remote response time cannot workplaces, and DICOM nodes
be guaranteed. It is necessary to • License management
System IT availability with fast and
calculate additional costs to ensure • Detailed information about
professional service provision:
a proper onsite support. These costs installed hardware and software
• Ensure a high quality of reports, can be calculated by your local
readings, and results when they • Access control for Smart
Service Organization or your regional
are needed by keeping the system Remote Services and remote
sales support team.
up-to-date, high performing, and administration
available Depending on customer • In case of errors, suggestions for
infrastructure, Siemens Healthineers further analyses and corrective
• Rely on our team of specialists
can provide a router to establish the actions
who provide fast and
connection between customer’s
comprehensive remote support The Administration Portal can be
internal network and the Smart
up to 24/7 using the SRS accessed by IT Administrators from
Remote Services infrastructure.
infrastructure and features workplaces inside a local network
• Protect your budget and system and by Siemens Healthineers Service
investment: Keep your software Engineers using a Service Key for
up-to-date and operational over special access authorization.
the entire product lifecycle
• Get the most out of your assets
with optimized system usage
52
syngo.via · Software Version VB40A
Education Plans
To empower your staff with • pre-training clarification With PEPconnections – our premium
expertise, Siemens Healthineers (remote or onsite) subscription for workforce education
offers continuous education tailored • dedicated number of syngo.via management – you can assign and
to your institutions needs based on training hours/days, depending on manage the education of your staff,
a blended learning approach. the specific applications and users ensuring to your employees a
for your institution. continuous education path.
At the time, your syngo.via is
installed, an initial training is To give you the possibility to We offer 3 different Education Plans:
provided to guarantee a seamless increase your knowledge at your Education Plan GAIN, Education
start with your syngo.via software. pace, you will have access to Plan GROW and Education Plan
The Handover training is delivered Siemens Healthineers learning LEAD. Our solutions to customers
by the Clinical Education Specialist platform – PEPconnect –, where who would like to GAIN confidence,
and includes you can benefit from online trainings GROW capabilities and LEAD
and educational videos, focused on with expertise.
• clinical integration of the main
the utilization of your syngo.via
modality
clinical applications.
Education Plans
GAIN Confidence. GROW Capabilities. LEAD with Expertise.
Education Plan GAIN is always part of any syngo.via delivery. You do not have to do any additional investment on
your side. You can upgrade to Education Plan GROW or LEAD to include additional education activities and formats,
all customizable to best meet your institution’s needs.
1
In case of a multi-year contract
2
Availability of the assessment depends on country
53
syngo.via · Software Version VB40A
1
Prerequisites include: Network connection to clinical network, DICOM compliance, meeting of minimum hardware requirements,
and adherence to local data security regulations.
54
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
SY Medical Devices1 Clinical Application
Note: WebViewer is not connected to medical IT systems and does not use DICOM as a communication protocol.
The communication to syngo.via is done through proprietary interfaces. It can process DICOM objects stored on the
syngo.via server only.
1
See German legal manufacturer address on p. 69.
2
The application syngo.via WebViewer is not for diagnostic viewing/reading on mobile devices in the US. Please refer to your sales representative whether the
product is available for your country. Diagnostic reading of images with a web browser requires a medical grade monitor. For iPhone and iPad country-specific laws
may apply. Please refer to these laws before using for diagnostic reading/viewing. For Japan: Applications on iPhone/iPad/iPod are not a medical device in Japan. Use
at your own risk. They are not intended to be used for diagnosis.
55
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
CT Medical Devices1 Clinical Application
1
See German legal manufacturer address on p. 69.
2
Included in syngo.CT Neuro Perfusion
56
syngo.via · Software Version VB40A
1
See German legal manufacturer address on p. 69.
57
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
CT Medical Devices1 Clinical Application
1
See German legal manufacturer address on p. 69.
58
syngo.via · Software Version VB40A
1
See German legal manufacturer address on p. 69.
2
Kidney Stones is designed to support the visualization of the chemical composition of kidney stones and especially the differentiation between uric acid
and non-uric acid stones. For full identification of the kidney stone, additional clinical information should be considered, such as patient history and urine testing.
Only a well-trained radiologist can make the final diagnosis under consideration of all available information. The accuracy of identification is decreased in obese patients.
3
Not yet approved for USA.
59
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
CT Medical Devices¹ Clinical Application
1
See German legal manufacturer address on p. 69.
2
This feature is pending 510(k) clearance, and is not yet commercially available in the United States.
3
Kidney Stones is designed to support the visualization of the chemical composition of kidney stones and especially the differentiation between uric acid
and non-uric acid stones. For full identification of the kidney stone, additional clinical information should be considered, such as patient history and urine testing.
Only a well-trained radiologist can make the final diagnosis under consideration of all available information. The accuracy of identification is decreased in obese patients.
4
Not yet approved for USA.
60
syngo.via · Software Version VB40A
1
See German legal manufacturer address on p. 69.
2
This feature is not commercially available in the U.S.
61
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
CT Medical Devices¹ Clinical Application
1
See German legal manufacturer address on p. 69.
62
syngo.via · Software Version VB40A
syngo.MR Brain
Morphometry2
syngo.MR Tractography
syngo.MR Cardiac 4D
Ventricular Function
syngo.MR Onco
syngo.MR OncoTrend2
syngo.MR 3D Lesion
Segmentation
syngo.MR Tissue4D
syngo.mMR General
syngo.MR BreVis
1
See German legal manufacturer address on p. 69.
2
This feature is still under development, and is not yet commercially available in the United States.
3
This feature is not commercially available in the U.S.
63
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
MI Medical Devices1 Clinical Application
1
See US legal manufacturer address on p. 69.
2
This feature is pending 510(k) clearance, and is not yet commercially available in the United States.
3
This feature is not commercially available in the U.S.
64
syngo.via · Software Version VB40A
1
See US legal manufacturer address on p. 69.
65
syngo.via · Software Version VB40A
Mapping Table
Medical Devices to Applications
Mammography Medical Devices¹ Clinical Application
syngo.Interventional iFlow
1
See US legal manufacturer address on p. 69.
66
syngo.via · Software Version VB40A
67
Caution: US federal law restricts the herein described
devices to sale by or on the order of a physician.