RECEIVED DATE: 13-Mar-24
Semua Hasil Tes Dalam Batas Normal. Ambil Sampel Oli Pada Interval 250 Jam Untuk Memonitor Kondisi.
WEAR METAL/CONTAMINANT/ADDITIVES
09-Mar-24 26-Jan-24 07-Dec-23 14-Nov-23
TOTAL BASE NUMBER (mg KOH/ g)
ELEMENTS (ppm) 8.9 8.7 9.0 5.1
TBN Total Base Numbe
Cr Chromium 1 0 0 3
Pb Lead 1 0 2 20
Fe Iron 12 8 7 40
WATER CONTAMINATION
Cu Copper 1 2 1 5
W Water N N N N
Al Aluminum 5 4 4 18
Sn Tin 1 0 0 1
Ni Nickel 0 0 0 0
44 61 72 16 PARTICLE QUANTIFIER INDEX
B Boron
PQI PQ Index 0 0 0 0
K Potassium 0 1 1 3
Na Sodium 0 1 3 6
Si Silicon 7 6 5 35 PARTICLE COUNT AND OTHER ANALYSIS
Ca Calcium 3381 4364 3459 3717 09-Mar-24 26-Jan-24 07-Dec-23 14-Nov-23
809 1007 820 868 VISUAL
P Phosphorus
PCV PC Visual - - - -
Zn Zinc 1049 1272 1005 1117
Mg Magnesium 24 24 30 20
Mo Molybdenum 44 45 46 44
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
ENGINE
J21A-54074-0916
SERIAL NUMBER: 31027_J210
EQUIP NUM: HD10-001
No Action Required
KOMATSU HD785-7
Report Comment
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2