RECEIVED DATE: 08-Apr-24
Semua Hasil Tes Dalam Batas Normal. Ambil Sampel Oli Pada Interval 250 Jam Untuk Memonitor Kondisi.
WEAR METAL/CONTAMINANT/ADDITIVES
26-Mar-24 03-Feb-24 08-Jan-24 16-Dec-23
TOTAL BASE NUMBER (mg KOH/ g)
ELEMENTS (ppm) 10.5 9.5 9.8 10.5
TBN Total Base Numbe
Cr Chromium 0 0 1 0
Pb Lead 1 1 1 1
Fe Iron 4 9 13 8
WATER CONTAMINATION
Cu Copper 0 1 2 1
W Water N N N N
Al Aluminum 1 2 2 2
Sn Tin 0 1 1 1
Ni Nickel 0 0 0 0
80 78 58 62 PARTICLE QUANTIFIER INDEX
B Boron
PQI PQ Index 0 0 0 0
K Potassium 1 1 1 0
Na Sodium 0 0 0 0
Si Silicon 3 3 5 5 PARTICLE COUNT AND OTHER ANALYSIS
Ca Calcium 3294 3610 2982 3463 26-Mar-24 03-Feb-24 08-Jan-24 16-Dec-23
802 850 703 815 VISUAL
P Phosphorus
PCV PC Visual - - - -
Zn Zinc 990 1042 949 1010
Mg Magnesium 32 18 38 39
Mo Molybdenum 41 40 41 45
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
ENGINE
J21A-54100-0802
SERIAL NUMBER: 31029_J210
EQUIP NUM: HD10-003
No Action Required
KOMATSU HD785-7
Report Comment
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2