You are on page 1of 4

Service Data Vickers®

Vane Pumps

Vane Type Double Pumps


V3200-S214

Revised 10/01/85 I-3128-S


Capacity (GPM) ”O” Ring Vane Kit Cartridge
Ring Rotor
Shaft End (2 req’d) (12 Vanes) Kit
Included in cartridge kit
V323*-15-*-***-10-S214 126023 919146
V323*-19-*-***-10-S214 Y154098 126024 912033 233603 919147
V323*-24-*-***-10-S214 126025 919148

236217 Pressure
Plate S/A

114139 Spring 139533 Pin (4 Req’d)

129344 Cover

240625
Pressure
138555 Plate S/A
Body (Inner)

12016
Bearing

”O” Ring Vane Kit


Capacity (GPM) Screw (4 Req’d) Ring Rotor Cartridge Pin
(2 req’d) (12 Vanes)
Cover End Torque to 70 ± 5 lb. ft. Kit (2 Req’d)
Included in cartridge kit
V323*-**-2-***-10-S214 116141 912063
131485 172302 912031 2161
V323*-**-5-***-10-S214 114173 912064
Y154090
V323*-**-8W-***-10-S214 178183 172294 912032 922509 2478
131486
V323*-**-11W-***-10-S214 218320 215043 922568 922574 16662
3418 Key
138556
Shaft

138583 Spacer 117785 Bearing

Y 232855 Seal
(Assemble with
138558 Spring toward
Body (Outer) inside of Pump)

Y 154098
”O” Ring

102949 117522
Retaining Ring Ring
(2 req’d)
1159 Screw
Y 154078 (4 req’d)
Seal Torque to
70  5 lb. ft.
138741 Spring

Mounting Gasket Mouting Bolt


Y Included in seal kit 922763 V32*0-*-*-***-10-S214
V32*4-*-*-***-10-S214 122896 1072 (6 Req’d)
F3 Equivalent 919296 seal kit
V32*5-*-*-***-10-S214 134305 128747 1274 (6 Req’d)
Model Code

1 2 3 4 5 6 7 8 9 10 11

1 Model Series 6 Capacity 9 #1 Outlet Body (**)


(Shaft end pump) #2 Outlet Cover (**)
V - Vane pump
(See below)
2
7 Capacity
Pump Size - Shaft End
(Cover end pump) 10 Design & Modification
3 Pump Size - Cover End
4 Body Type 8 Shaft 11 Special Feature Designed for
Industrial Applications
5 Mounting

0 - Face
4 - Foot
5 - Flange

#1 Outlet Body, #2 Outlet Cover Port Positions Designations


(Viewed From Cover End)
In Line
With Inlet
90_ Counter
Clockwise
#2 Outlet Cover In Line Inlet From Inlet C #1 Outlet Body
With Inlet Position

C B

D
B
90_ Counter
Clockwise
From Inlet A 90_ Clockwise
D From Inlet
Inlet Housing Opposite
A
Inlet
Opposite 90_ Clockwise
Inlet From Inlet

Cover and Body are shown in


”CC” position. Reference
Installation Drawing I–248701.

For satisfactory service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code
20/18/15 or cleaner. Selections from Eaton OFP, OFR, and OFRS series are recommended.
Printed in U.S.A.