AC Servo System Wiring
Standard wiring examples
This wiring diagram shows basic wiring only, and additional wiring configurations are possible for some I/O.
Refer to the “Installation and Wiring” chapter of the User Manual for more detailed wiring information.
DO 1– /OA Encoder
At Zero Speed OB Signal Output
DO 2+ B phase pulse
Default Settings
/OB (scalable
100 mA max
DO 2–
OZ pulse output)
Homing Complete DO 3+ Z phase pulse
/OZ 40 mA max
DO 3– CN3***
At Position DO 4+ RS422 TXD–
DO 4– RS422 TXD+
Alarm RS422 RXD– & RS232 RX
DO 5+
RS422 RXD+
DO 5–
User Supplier 24 VDC RS232 TX
(FG) GND
Modbus communication to PC, PLC, etc
* Use connection kit part #s ZL-RTB50 & ZL-SVC-CBL-50(-x) for CN1 terminal connections.
** Use cable part # SVC-Exx-0x0 for CN2 terminal connections.
*** Use cable part # SVC-MDCOM-CBL for CN3 terminal Modbus network connections.
TrqLimEn(Vmode)/SpdLimEn(Tmode) DI 2
Default Settings
VCS0(Vmode) / TCS0(Tmode) DI 3
VCS1(Vmode) / TCS1(Tmode) DI 4
Alarm Reset DI 5
Reverse Inhibit Overtravel DI 6 CN1* SG
MON 1
Forward Inhibit Overtravel DI 7 ±8V
GND
Fault Stop DI 8 1mA max
MON 2
CN1* CN1*
Servo Ready DO 1+
Use diode if driving inductive load
OA
1.5k Ohm min load impedance
B phase pulse
100 mA max
DO 2– /OB (scalable
At Speed DO 3+ OZ pulse output)
Z phase pulse
DO 3– /OZ 40 mA max
Brake Control DO 4+ CN3***
RS422 TXD–
DO 4– RS422 TXD+
Alarm DO 5+ RS422 RXD– & RS232 RX
DO 5– RS422 RXD+
User Supplier 24 VDC
RS232 TX
(FG) GND
Modbus communications to PC, PLC, etc.
* Use connection kit part #s ZL-RTB50 & ZL-SVC-CBL-50(-x) for CN1 terminal connections.
** Use cable part # SVC-Exx-0x0 for CN2 terminal connections.
*** Use cable part # SVC-MDCOM-CBL for CN3 terminal Modbus network connections.