Product Description

KC97 (updated edition) cold shrink tube are designed for weatherproofing
KC97
protection on cell site transmission line, comprising connections between (updated edition)

jumper cable and RF devices such as RRU/RRH, Antenna, Combiner etc., Cold Shrink Tube
through connectors of 7/16 DIN, N type or 4.3-10,or AISG cable to RET.
Multi-Layers
Comparing with conventional tape, the cold shrink tube is easy and fast

installation (15-30 seconds), conveniently mounting in vertical and horizontal

directions, uniform quality and IPX8 performance not effected by workmanship.

Feature
 Multi layers structure designing, improve waterproofing and nick, tear

resistance

 IPX8 class, stable, proved long operational life

 Easy to install, three steps (Cover, pull and clench)

 Tool free and fast installation, only 15-30 seconds for one RF ports sealing

 No limitation of spare space, especially design for narrow space, MIMO

Antenna etc.,

 Easy to uninstall, need knife to cut tube open and no sticky mastic left

 No skill required by engineers, uniform quality after installation, stable

good sealing and weatherproofing performance

 Much time cost, and labor cost saving

 Good operating capability under extremely cold and hot environment,

highland, salt-mist situation, heavy windy weather, and anti-UV, anti-ozone

 Storage temperature: -40℃~+50℃

 Installation temperature: -20℃~+50℃

 Long time service temperature: -60℃~+90℃

SHENZHEN COTRAN NEW MATERIAL CO.,LTD WWW.COTRANGLOBAL.COM


Product Description
Ver: EN201903 V3.6

Properties

Parameter and
Item Test Method
Result
IEC 60529: 1989+A1: 1999+A2: 2013;
Waterproof Class Pass, IPX8
1 meter depth in water, duration: 4 hours

Shore Hardness 40±5 ASTM D2240-15

Tensile Strength >7.0 MPa ASTM D412-15a Method A


Elongation >800% ASTM D412-15a Method A
Tear Strength >25 KN/m ASTM D624-00(2012)
Physical and Brittleness
mechanical temperature by Pass ASTM D746-14,-60℃
properties impact
No damage,
Provided by client:
deformation, and
Drop height: 1.2m
Drop Test the support strip
Drop surface: Tile floor
could be pulled out
Drop times: 3
normally
Horizontal
Flammability HB UL 94-2013 Rev.6-2016 Section 7
burning
Dielectric
Electricity >22KV/mm ASTM D149-09(2013) Method A
Strength
No crack, ISO 4892-3:2016 Cycle1& ISO 105-
discoloration, A02:1993/Cor.2:2005
Light aging test- damage or Lamp type: UVA-340, 8h UV at (60±3)℃
UV exposure deformation BPT,0.76W/(m²×nm)@340nm
Grey scale: 4-5 4h condensation at (50±3)℃ BPT
Aging test IPX8 Pass Exposure duration: 1000 hours
No crack,
ASTM D1149-16 Method B procedure B1
discoloration,
Temperature: 40±1℃
Ozone aging damage or
Ozone concentration: 50±5 pphm
deformation,
Exposure duration: 72 hours
IPX8 Pass
Environmental RoHS IEC 62321
Material
protection Reach SVHC

Note: This is typical value under lab test, and refer to Cotran KC97 SGS test report.
SHENZHEN COTRAN NEW MATERIAL CO.,LTD WWW.COTRANGLOBAL.COM
Product Description
Ver: EN201903 V3.6

Dimension

Picture 1. Dimension before shrink

Picture 2. Dimension after shrink

I.D Relaxed I.D Relaxed Length Average wall thickness


Mode
(mm) (mm) (mm) (mm)
KC97-4310 ≥25 9±1 ≥140 2.5±0.5mm

KC97-RF ≥37 11±1 ≥140 2.5±0.5mm

KC97-RET ≥25 6±1 ≥110 2.5±0.5mm

Shelf Life

KC97 (updated edition) cold shrink tube have a 2-year shelf life from date of manufacture when stored in the

range of 10°C to 28°C temperature and <75% relative humidity.

SHENZHEN COTRAN NEW MATERIAL CO.,LTD WWW.COTRANGLOBAL.COM


Product Description
Ver: EN201903 V3.6

Installation

Step 1:Wrap the cold shrink tube with mastic around all jumpers in sequence before installing the connectors.

Connector to
be wrapped

Arrow
direction

Step 2: Tighten the connectors of all jumpers with specified torque according to jumper installation

instructions. All the jumpers should be installed and fixed before the installation of cold shrink tube.

Attention:
Do not rotate the adjacent connectors of a connector that has been wrapped with a cold shrink tube
with mastic. Unless the tube has been protected well in advance, Otherwise, the cold shrink tube with
mastic may be damaged.

Crack

Step 3: Install cold shrink tube with mastic.

3-1 Push the cold tube to the end of connectors and gently pull out the support strip along the jumper.

(unwind the strip around the jumper)

Attention:
When installing the cold shrink tube, do not wrap the screw in the flange, or it will easily lead to the
waterproof failure.
SHENZHEN COTRAN NEW MATERIAL CO.,LTD WWW.COTRANGLOBAL.COM
Product Description
Ver: EN201903 V3.6

3-2 Push the cold shrink tube to the end of the connector while pulling the support strip until the tube

shrinks and secures the connector. Do not push or pull the tube after the tube shrinks. Otherwise, shrinkage

of the tube may deteriorate, or the tube may be damaged.

Note: Never push


or pull the cold
shrink tube after
it has shrunk
around the end of
the connector.

3-3 Pull out the support strip along the direction indicated by the arrow. If the support strip fails to be

removed smoothly, rotate it around the jumper while pulling it out slowly. Never pull the support strip forcibly.

Note: Ensure that the


tube around the end of
connectors and that the
most distance between
the end of tube and the
connector end is less
than 5mm.

Step 4: After the installation of cold shrink tube with mastic, press and hold the cold shrink tube by hand,

especially the parts with mastic, repeat 3 to 5 times to ensure the mastic attached on the jumper completely.

Step 5: Repeat step 3 and 4 to install cold shrink tubes on other Jumpers.

SHENZHEN COTRAN NEW MATERIAL CO.,LTD WWW.COTRANGLOBAL.COM