POWER UNITS
AC
A UNIT
Active ionization equipment operates
on high voltage.
The power units transform the mains
voltage to the high voltage required by
the ionizer. There are different types of
power units available.
Power units are easily connected
and operated and don’t need any
E-173152
maintenance.
TYPE A2A4S AND A2A7S T E C H N I C A L S P E C I F I C AT I O N S
The standard model has a modern styling featuring easy-access control and connec- A Unit
tions. It is equipped with an on/off switch with an indicator lamp as well as a high- Housing material aluminum and steel, powdercoating
voltage indicator lamp. This lamp will extinguish if the system is malfunctioning. Weight 2,8 kg
Four ionizers can be connected as a maximum. Connections 4
On/off switch with lamp yes
High voltage indication neon lamp
TYPE A2A4D
Cable 1,8 m
This power unit can be switched off at a preset drop in high-voltage output, for
Ambient temperature 0 - 50 °C
instance due to short-circuiting.
Use circumstances industrial
Protection classification IP-54
TYPE A2A5G U primairy 110 V or 230 V *
For ionizing air gun type Cobra. Frequency 50 or 60 Hz*
Power consumption 50 Watt
TYPE A2A3S U secundairy 3,3 - 7 kV AC *
I secundairy 2,5 mA max.
For ionizing air nozzle type BW and BFW.
Options BHR, D
Approval UL*
TYPE A2A5S
*Contact Simco for other voltages, frequencies and approvals.
For anti-static bar type MaxION.
www.simco.nl
POWER UNITS
AC
A UNIT BHR
TYPE A2A4BHR AND A2A7BHR
This type is similar to the A2A4S and A2A7S but is also fitted with a PCB offering
the following options:
B: Ion balance.
Using an electronic circuit, the ion balance can be adjusted accurately by a
potentiometer.
H: High-voltage control.
Apart from the high-voltage indicator lamp, the PCB is fitted with a relay with
make contacts. If the high voltage fails, the relay immediately closes the circuit to
activate an alarm (lamp, PLC etc.).
R: Remote control.
The power unit can be remotely switched on or off by a potential-free contact
(e.g. a PLC).
29
POWER UNITS
BIPHASE
LB UNIT
Additionally to the standard A-series
power units, SIMCO offers some other
power units for specific products or
applications. SIMCO shall gladly advise
you on selecting the model which suits
your specific application best.
TYPE LB2A4S AND LB2A7S T E C H N I C A L S P E C I F I C AT I O N S
This power unit is equipped with two high-voltage transformers with 180°phase- LB
shifted output voltages. As a result, the anti-static bars connected to the power Housing material steel, powdercoating
unit produce positive and negative ions simultaneously. This ensures optimal Weight 6 kg
neutralization of static charges even at very high velocities. This power unit is fitted Connections 2x4
On/off switch with lamp yes
with two high-voltage indicators and an on/off switch with an indicator lamp.
High voltage indication neon lamp
Cable 1,8 m
TYPE LB2A4BHR AND LB2A7BHR
Ambient temperature 0 - 50 °C
Use circumstances industrial
For specifications on the BHR print see type A2A4BHR and A2A7BHR Protection classification IP-54
(page 29). U primairy 110 V or230 V *
Frequency 50 or 60 Hz*
TYPE LB2A4D Power consumption 100 Watt
U secundairy 4 - 7 kV AC *
I secundairy 2,5 mA max.
For specifications on the “D” option see type A2A4D (page 28).
Options BHR, D
*Contact Simco for other voltages and frequencies.
www.simco.nl