Professional Documents
Culture Documents
S7-400/1 S7-300/1
"Production"
system Other station
Ethernet subnet 1
(Industrial Ethernet)
SIMATIC S5
S7-300/2
Contents Page
Network/Project Type : More than One Subnet in More than One Project.................................. 8
1. You create one or more subnets of the required type in the project
2. You define properties of the subnets; the default settings are usually
sufficient
3. You establish a “logical” connection between the stations and the subnet
1 1 subnet - 1 project
The table shows examples of different types of networks which are discussed on
the following pages to illustrate how you can represent different configurations in
a STEP 7 project.
S7-400/1 S7-300/1
"Production"
system
Ethernet (1)
S7-300/2
System In the simplest case, your system will consist of SIMATIC S7 stations that
Configuration you want to link together in one subnet, using Industrial Ethernet for example.
STEP 7 Project To do this, you create an Ethernet object in the STEP 7 project.
Representation Stations created in the same project refer to this object as soon as they are
configured as network nodes.
S7-400/1 S7-300/1
"Production"
system Other station
Ethernet (1)
SIMATIC S5
S7-300/2
System In addition to SIMATIC S7 stations you may have SIMATIC S5 and non-
Configuration SIMATIC stations connected to Industrial Ethernet in your system.
S7-400/1
Ethernet (1)
"Production and Ethernet CP
Management Level"
S7-400/2
system
PROFIBUS CP
PROFIBUS (1)
S7-300/1 S7-300/2
System The different functions of the stations or the size of the system may make
Configuration it necessary to have more than one network.
STEP 7 Project You can put all the subnets in one STEP 7 project. This is the simplest
Representation way of configuring the stations for communication.
Summary
• More than one subnet can be handled in one project.
• A station can be included in more than one subnet by assigning the CPs
accordingly.
“Production 1” “Production 2”
S7-400/1 S7-400/2
Ethernet (1)
System For complex networks it may be more practical to divide the management
Configuration of the stations into different projects.
S7 Project In order to be able to address stations in other projects (e.g. Production 2),
Representation you also enter them as Other Stations in the rest of the projects (e.g. Production
1).
Ethernet (1)
Cell level
Ethernet CP
S7-400/1
PROFIBUS CP
Field level
PROFIBUS (1)
S7-300/1 S7-300/2
System If the different functions of the stations or the size of the system make it
Configuration necessary to have different types of network and you want to use different
projects to manage them, the stations in other projects can also be accessed by
configuring “Other Stations”.
S7-400/1
Ethernet (1)
or Internet
Router WAN
Ethernet (2)
S7-300/1
Ethernet CP
S7-400/2
S7-300/1
System If the different functions of the stations or the size of the system make
Configuration it necessary to link subnets to one another via a WAN or a router, the stations in
other subnets can be accessed by configuring "Other Stations".
STEP 7 Project The screenshot below shows the NETPRO representation if the stations in
Representation both subnets are managed in the same project.