Scupper Details for NYDOT Specifications
Scupper Details for NYDOT Specifications
1'-6•"
1'-2†"
1‹" 1‹"
5" OUTLET TO BE PLACED
AT LOW END OF SCUPPER
CURB
1‹"
3ˆ "
•" p
5"
SEAT FOR GRATING SHALL BE •" p
FABRICATED TO A TRUE PLANE
A A 1'-6•"
2‰ "
GROVE WELD
1‹ "
GRIND SMOOTH
8"
•" •"
-10„ "
(TYPICAL)
-6‚ "
2‰" 1" „" (SEE NOTE 2) 1" TYP.
SEAL WELD
1'
1'
2• "
3‡ "
TYP. „" 1‹"
‚ •" p •"
•"
5•" AT 6•" AT
2‰"
HIGH CORNER •" LOW CORNER
•"
1"
8"
‚
THIS SIDE OF TUBE
2‰ "
SCUPPER GRATING DETAIL
1‹ "
ON BD-MS2E.
NOTES: 1" TYP.
538" 8" 538"
ALL MATERIAL SHALL BE GALVANIZED IN ACCORDANCE WITH N.Y.S.
STANDARD SPECIFICATIONS SUBSECTION 719-01. DESIGNER NOTES:
1‹"
THE SCUPPER MAY BE ROTATED 180n IF THE LOCATION OF THE OUTLET DETERMINE THE NUMBER †" †"
PIPE AS SHOWN WILL INTERFERE WITH OR DRAIN ON ANY PORTION OF THE 2‰"
OF SCUPPERS REQUIRED BASED ON THE
SUPERSTRUCTURE GIRDERS OR FRAMING. REQUIREMENTS OF HEC-21.
"
NOT TO SCALE
16
1
2
3
3
5"
5"
†"
†" TYP.
8"
†"
B B
OUTLET TO BE PLACED AT
1'-5•"
LOW END OF SCUPPER †" †" NOTES:
-10… "
"
4
2• "
1
-6
1" 1‰"
1'
1'
1‚" vSLAB AND TOP OF SCUPPER „ in. BELOW TOP SURFACE OF SLAB.
5‡ "
7„ "
2. IF SCUPPERS ARE LOCATED IN HAUNCH AREAS ABOVE BEAMS, THE SCUPPERS SHALL BE
8"
TAPPED HOLE FOR vBLOCKED UP OFF THE FORMS SO AS TO LOCATE TOP OF SCUPPER „ in. BELOW TOP SURFACE
ƒ" DIA. BOLT (TYP.) 1" vOF SLAB AS SHOWN.
1"
1•" TYP.
SEE NOTE 1 3. STRUCTURAL SLAB CONCRETE IMMEDIATELY ADJACENT TO SCUPPERS SHALL BE THOROUGHLY
†"
TAPPED HOLD FOR vVIBRATED DURING PLACEMENT TO ELIMINATE VOIDS WHICH COULD RESULT IN PREMATURE
•" CAP SCREW (TYP.)
"
vCONCRETE DETERIORATION.
"
5"
16
16
†"
3
1
4. IN CERTAIN CASES, THE SCUPPER DIMENSION SHOWN PERPENDICULAR TO THE CURB WILL BE
2
vINSUFFICIENT TO LOCATE THE DOWNSPOUT INSIDE THE FASCIA BEAM. IN THESE CASES, A
vLARGER SCUPPER, REQUIRING SPECIAL DETAILS, WILL BE REQUIRED.
ƒ" DIA. BOLTS (TYP.) SEE DETAIL "B"
1'-634"
ISSUED STATE OF NEW YORK
01
DEPARTMENT OF TRANSPORTATION
DATE/TIM E = 19-APR-2016 12:
NOTES: 5/01/08
OFFICE OF STRUCTURES
PLAN REVISED
dgn
USER = jdellarocco
CURB
2• "
BE DESIGNED IF WEB
DEPTH EXCEEDS 3 ft.
SECTION A-A
DETAILS OF SPILL AREA FOR SCUPPERS
(FABRICATED SCUPPER & GRATE) 12-#5 EPOXY COATED BARS 3'-8" LONG.
NOT TO SCALE
NOT TO SCALE THESE BARS ARE TO BE PLACED IN A MAT
LOCATED BETWEEN THE MAIN SLAB
REINFORCEMENT (NOT SHOWN).
NOTE:
1‰" (TYP.)
† "
DIRECTION OF TRAFFIC
-8"
8 SPACES @ 2• " = 1'
† "
FOR WATER SERVICE.
-8• "
1'
•" •"
•" p (TYP.)
A PLAN c OF FLANGE
DETAILS ON THE DRAWINGS LABELED AS "NOT TO SCALE" ARE
INTENTIONALLY DRAWN NOT TO SCALE FOR VISUAL CLARITY. ALL
OTHER DETAILS, FOR WHICH NO SCALE IS SHOWN, ARE DRAWN
PROPORTIONAL AND ARE FULLY DIMENSIONED.
FLANGED CONNECTIONS FOR OUTLET
SCUPPER GRATING (FOR TYPES "B1" & "B2")
OF TYPE "B1" SCUPPER
STATE OF NEW YORK
03
5/01/08
OFFICE OF STRUCTURES
dgn
REVISED
USER = jdellarocco
NOTES:
NOTES:
FILE NAM E = BD-M S2E.
6"u .20
6"u .20
3"u .10
+.04
u .04 +.06 -.03
WOOD FORM - REAR FACE OF WALL +.04 +.03 NOTES TO DESIGNER:
-.03 u .02
-.03 -.05
THE WATERSTOP TYPES LISTED BELOW SHALL BE USED
+.08
+.08 AT THE FOLLOWING LOCATIONS.
-.04
&" LONG ST -.05
VERTICAL @ 6"u CENTERS TYPE D: CONSTRUCTION AND CONTRACTION JOINTS.
u .04
u .04
R" TYPE E: EXPANSION JOINTS.
7 SPAC u .04
+.04
STAPLING TO WOOD FORM WILL
-.03
ONLY BE PERMITTED IN THIS u .06 TYPE A: CONSTRUCTION AND CONTRACTION JOINTS ONLY
u .06
TYPE B: EXPANSION JOINTS WHERE ANTICIPATED
TYPE A WATERSTOP
vMOVEMENT IN EITHER DIRECTION DOES NOT
NOT TO SCALE vEXCEED 1".
TYPE D WATERSTOP vUSE ONLY WHEN A TYPE E CANNOT BE USED.
NOT TO SCALE TYPE A WATERSTOP:
TYPE CA: ONLY IN SPECIFIC ABUTMENT APPLICATIONS.
NOTES:
HOLES MUST NOT BE MADE IN WATERSTOP FOR ANY PURPOSE. vEXAMPLE: IN THE 1960’S AND 1970’S, "BR
vSHEETS" SHOWED TYPE CA WATERSTOP AT
HOLES MUST NOT BE MADE IN WATERSTOP FOR ANY
vTHE TOP OF ABUTMENT BACKWALLS. IT WAS
PURPOSE EXCEPT AS REQUIRED FOR STAPLING TO FORMS.
vUSED ADJACENT TO THE EXPANSION JOINT
vBETWEEN STRUCTURAL AND APPROACH SLABS
TYPE D WATERSTOP SHALL BE LIGHT GRAY IN COLOR.
vTO SEAL THE JOINT BETWEEN STRUCTURAL
vSLAB AND TOP OF BACKWALL. IF THIS DETAIL
vIS BEING RETAINED ON A WIDENING CONTRACT,
7"u .20 vTYPE CA WILL BE REQUIRED.
1" X "
WOOD FORM - REAR FACE OF WALL NAILED TO WOOD FORM
-.03 -.05
&" LONG ST
u .04 +.06
VERTICAL @ 6"u CENTERS
-.03
u .06
PREMOULDED RESILIENT
STAPLING TO WOOD FORM WILL
JOINT FILLER
ONLY BE PERMITTED IN THIS
AREA ON EACH SIDE.
+.06 1 "
-.03
STAGE ONE - PRIOR TO POURING CONCRETE NOTES:
+.06
7 SPAC
-.03
PVC USED IN WATERSTOPS SHALL CONFORM TO THE REQUIREMENTS
TYPE B WATERSTOP OF N.Y.S. STANDARD SPECIFICATIONS SUBSECTION 705-11.
7"u .20
NOT TO SCALE
THE COST OF FURNISHING AND PLACING WATERSTOPS SHALL BE
3 u .10 INCLUDED IN THE UNIT PRICES BID FOR THE CONCRETE ITEMS.
+.06 NOTES:
+.09 u .06
+.05 PREMOULDED RESILIENT JOINT FILLER SHALL CONFORM TO THE
-.04 -.02 REQUIREMENTS OF N.Y.S. STANDARD SPECIFICATION SUBSECTION 705-07.
+.02
-.05 DETAILS ON THE DRAWINGS LABELED AS "NOT TO SCALE" ARE
1"u .08
u .04 INTENTIONALLY DRAWN NOT TO SCALE FOR VISUAL CLARITY. ALL
+.05
+.06 OTHER DETAILS, FOR WHICH NO SCALE IS SHOWN, ARE DRAWN
-.02
-.03 PROPORTIONAL AND ARE FULLY DIMENSIONED.
JOINT FILLER INTENTIONALLY DRAWN NOT TO SCALE FOR VISUAL CLARITY. ALL
+.05
OTHER DETAILS, FOR WHICH NO SCALE IS SHOWN, ARE DRAWN
-.02
PROPORTIONAL AND ARE FULLY DIMENSIONED.
2
u .04
+.06 +.06
STAGE TWO - AFTER FORMS HAVE BEEN REMOVED -.03 -.03
u .06
TYPE E WATERSTOP
NOT TO SCALE +.06
-.03 5 SPA u .04 +.05
-.02
NOTES:
8"u .20
PVC INSERT AND PRESSURE SENSITIVE RELEASE TAPE SHALL BE HOLES MUST NOT BE MADE IN WATERSTOP FOR ANY PURPOSE.
INSTALLED IN THE FIELD PRIOR TO PLACING THE BACKFILL. APPROVED:
ORIGINAL SIGNED BY ISSUED UNDER EB 08-002
GEORGE A. CHRISTIAN, P.E. EFFECTIVE WITH THE
DEPUTY CHIEF ENGINEER LETTING OF 1/08/09
(STRUCTURES)
SAW OR HAMMERED FACE 5" 3-29-22
SLOPE TOP OF CURB TO
FRONT ARRIS LINE
BACK ARRIS LINE MATCH OVERLAY.
BACK ARRIS LINE
CAULKING COMPOUND FOR STRUCTURES FRONT ARRIS LINE EXPOSED FACE
CONFORMING TO N.Y.S. STANDARD 5"
SPECIFICATIONS SUBSECTION 705-06. TOP OF PAVEMENT
5• "
6"
-4" u 1"
SPLIT FACE
1'
1•" 3"
9"
-6"
2-#5 BARS
(PAID FOR UNDER ITEM 670.40)
8"
1'
-7• "
FASCIA LINE
-4"
1'
1'
10•"
2" N.P.S. CONDUIT (TYP.)
PAID FOR UNDER ITEM 670.2003
-6"
c OF 2" N.P.S. CONDUIT
4'
1'-4
#5 BARS #4 BARS @ 4" (MAXIMUM) SPACING TRANSFORMER
dgn
35
#4 BAR NOTES:
DATE/TIM E = 16-M AR-2022 11:
FILE NAM E = BD-M S4E_2022.
WEB
O.D. O.D. SEE NOTE 4 FOR
ƒ" p WEB
JOINT AND WELD
REQUIREMENTS.
SEE NOTE "A" SEE NOTE "A"
45n 45n
60n
CONICAL POINT COMMERCIAL OR COMMERCIAL OR
O.D.+†" PREFABRICATED SHOE PREFABRICATED SHOE
NOTE:
SEE WELDING NOTES.
NOTES: NOTES:
OPTIONS I AND II DIFFER ONLY 1. COMMERCIAL OR PREFABRICATED SHOES ARE SUBJECT TO THE APPROVAL OF THE DCES.
IN THE TYPE OF INTERMITTENT SPACER. CAST-IN-PLACE PILE SHOES
2. THE SHOE SHALL BE ATTACHED BY A NYSDOT CERTIFIED WELDER.
SEE WELDING NOTES.
DESIGNER NOTES: 3. A "WELDING PROCEDURE SPECIFICATION" (WPS) APPROVED BY THE DCES IS REQUIRED.
USE THE FLAT PILE SHOES UNLESS THE CONICAL TIP 4. THE SHOE WELD JOINT DESIGN SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S
SECTION THRU PILE AT SPLICE SECTION THRU PILE AT SPLICE IS CALLED FOR IN THE F.D.R. USE THE SHEET PILE RECOMMENDATION, AND AS SHOWN ON THE APPROVED WPS.
SHOES ONLY IF CALLED FOR IN THE F.D.R.
(OPTION I) (OPTION II) 5. IF SHOES ARE WELDED AT A LOCATION OTHER THAN THE PROJECT SITE, ALL OF THE ABOVE
FOR PROJECTS UTILIZING C.I.P. PILES, PROVIDE THE PROVISIONS SHALL APPLY TO THE OFFSITE FABRICATOR. THE DCES SHALL BE NOTIFIED BY THE
SPIRAL WELD TABLE AND APPROPRIATE NOTES FOUND CONTRACTOR OF THE ACTUAL LOCATION WHERE THE WELDING WILL BE PERFORMED A MINIMUM
WELDED SPLICE DETAILS
ON BD-PR7E IN THE CONTRACT PLANS. OF 5 WORKING DAYS BEFORE WORK COMMENCES.
-6" MIN.
SLEEVE
1" RADIUS
6'
PILE 2" COV. ACCESS HOLE
(LEAVE UNFILLED) STEEL BACKUP BAR
SLEEVE SEE B-U4b NOTE
ƒ "
6"
TO REMAIN IN PLACE
33 ft. MIN
T1
NOTE:
NOTE: PILE SEE WELDING NOTES. JOINT B-U4b JOINT B-U4a
‡" SEE WELDING NOTES. 6-#6 BARS
END OF PILE
-2" MIN.
-5"
SPLICE FOR STEEL H-PILE
1'
3" MAX.
PILE ELEVATION
PITCH
SECTION THRU SLEEVE SECTION THRU PILE AT SPLICE
2'
(MECHANICAL SPLICE ONLY)
-0"
MECHANICAL SPLICE DETAILS 6" BOTTOM OF
2'
FOOTING
WELDING NOTES:
9" MAX.
PILE LENGTH, WHICHEVER IS GREATER, BUT
PITCH
ALL WELDING SHALL BE PERFORMED BY A CERTIFIED WELDER IN
NOT TO EXCEED A MAXIMUM OF 30 ft.
CONFORMANCE WITH REQUIREMENTS FOR WELDING SPECIFIED IN THE
N.Y.S. STEEL CONSTRUCTION MANUAL.
PILE ELEVATION
1'-0"
BOTTOM OF FOOTING
CAST STEEL SHEET FOR A PITCH OF 9". IF TWO BARS ARE STATE OF NEW YORK
dgn
PILE PROTECTOR USED, A WELDED SPLICE SHALL BE USED. 5/01/08 DEPARTMENT OF TRANSPORTATION
"Z" SECTIONS
FILE NAM E = BD-M S5E_2022.
OFFICE OF STRUCTURES
REVISED
NOTE:
CONTRACTOR MAY USE AN
MISCELLANEOUS
CAST-IN-PLACE CONCRETE PILE
USER = gruth