JOB No. Rev. No. 0 Date 24.05.
2024
DQ.No. Rev. No. Date
Building Name JH KJ-9 Rev. No. Date
Client : Designed By Checked By
Summary of Unity checks
BASE PLATE FOR COL MKD C2 (AT ROW -AXIS A (1 to 3'), (1 to 3') & C (1 to 3') Checks Actual Allowable Unity Check
Tension Capacity of Bolt section area-kN 161.70 221.98 0.73
AB length w.r.t bond strength - mm 384.00 1000.00 0.38
DETAIL BP-1 REACTIONS = ACTUAL FORCE X 1.2 Shear Capacity of Bolt-kN 37.71 150.28 0.25
Node Reaction_Max Fy_compression case_Case-I
LC: 941 ( 0.9 (DL+EQP) +B.T.+ 1.5 WL(+X)Combined
(CPI+) axial and shear check 0.56 1.00 0.56
Shear-Fx (V) (Resultant of sqrt(Fx
124 + Fz) ) = 243.7 kN Plate thk. In compression(3 edge fix)- mm 22.12 45.00 0.49
Axial-Fy (P) = 1835.27 kN Plate thk in tension - mm 30.44 45.00 0.68
P/A+M/Z -N/mm2 7.65 11.25 0.68
Node Reaction_Min Fy_Tension case_Case-II
LC: 956 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-X) (CPI-)
Shear-Fx (V) (Resultant of sqrt(Fx
124 + Fz) ) = 199.98 kN
Axial-Fy (P) = 1293.27 kN
Node Reaction_Max Fx_Shear case_Case-III
LC: 920 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-X) (CPI-))
Shear-Fx (V) (Resultant of sqrt(Fx
164 + Fz) ) = 301.63 kN
Axial-Fy (P) = 632.85 kN (C)
COLUMN SECTION DETAILS
Web Depth x Thickness 268 mm 10 mm
Flange Width x Thickness 300 mm 16 mm STIFFENER DETAILS
Over all section depth 300 mm No.of stiffeners perpendicular to web (Sw) Yes 1
Dist. from compression flange to nearest web stiff. = 150 mm
BOLT DETAILS Flange stiffener Length (Lfs) = 185 mm
Anchor bolt grade = Grade 4.6 Flange stiffener height (Hfs) = 300 mm
Bolt diameter (d) = 36 mm Stiffener thickness (Tfs) = 10 mm
No.of bolt rows (nr) = 4
No.of bolts in each row (nb) = 2 STIFFENER DETAILS
Pitch (p) = 450 mm Grade of Concrete (fck) = M25
Pitch (p1) = 150 mm
Gauge (g) = 150 mm Permissible Compression(0.45 fck) (IS456:2000, Cl.34.4) = 11.25 N/mm2
Edge Dist. for Bolt (ed) = 75 mm Bond Stress σbs (IS456:2000, Cl.26.2.1.1) = 1.4 N/mm2
Dist. for Boltfrom flange (eg) = 75 mm
Anchor bolt with bottom plt = YES
Bolt bottom plate width = 100 mm ACTUAL FORCES
941 ( 0.9 (DL+EQP) +B.T.+ 1.5 WL(+X) (CPI+)
Bolt bottom plate width = 100 mm Maxi Compression
Yield stress of bolt (fyb) = 240 N/mm2 Shear-Fx 188.54
Ultimate tensile stress of bolt (fub) = 410 N/mm2 Axial-Fy 1835.27
Shear-Fz 154.41
956 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-X) (CPI-)
Maximum Tension
PLATE DETAILS Shear-Fx 193.20
Axial-Fy 1293.26
Plate thickness (t) = 45 mm
Shear-Fz 51.59
Min Plate width = 300 mm Maximum shear 912 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-Z) (CPI-)
Plt Width increment = 100 mm Shear-Fx 298.05
Plate width (B) = 400 mm Axial-Fy 632.85
Length Ext (Le) = 150 mm Shear-Fz 358.89
Plate Length (L) = 600 mm
Base plate fy = 240 N/mm2
Base plate fu = 410 N/mm2 *Web stiffener (Sw) shown is indicative, its presence and location depends on
Connection detail = BP4R2BP design requirement.
SHEAR CAPACITY OF BOLT
Design Shear Strength of the Bolt ( V dsb) = Vnsb/γmb (IS 800:2007, Cl.10.3.3, Pg-75)
Vnsb = fub/√3 * (nn*Anb+ns*Asb)
Partial saftey Factor (γmb) = 1.25
No. of Shear Planes with Threads (nn) = 1 per bolt
No.of Shear Planes with out Threads (ns) = 0 per bolt
Nominal Plain shank area of Bolt ( Asb) = 1017.36
Net shear Area of the Bolt at Threads (Anb) = 793.55 (0.78*Asb) ( IS4000:1992, Table-2)
fub/√3 * (nn*Anb+ns*Asb) = 410/√3 * (1*793.55 + 0*1017.36)
= 187.85
Vdsb = 187.85/1.25
Vdsb = 150.28
TENSION CAPACITY OF BOLT
DesignTensile Capacity of the Bolt ( T db) = Tnb/γmb (IS 800:2007, Cl.10.3.5, Pg-76)
Nominal Tensile Capacity of Bolt ( T nb) = 0.9 fub *An < fyb * Asb * (γmb/γm0)
Partial saftey Factor (γmb) = 1.25
Partial saftey Factor (γmo) = 1.10
0.9 fub *Anb = 0.9*410*793.55
= 293 kN
fyb * Asb * (γmb/γm0) = 240*1017.36*(1.25/1.1)
= 277 kN
Tnb = 277 kN
Tdb = 222 kN
1 Tension Check w.r.t bolt cross section
No.of bolts in tension side = 8
Tension in each bolt (Case-I) = 0 kN < 221.98 kN
Tension in each bolt (Case-II) = 161.7 kN < 221.98 kN
Tension in each bolt (Case-III) = 0 kN < 221.98 kN SAFE
Max tension in bolt = 161.7 kN
2 Tension Check w.r.t bond strength of concrete.
Anchor bolt dia (d) = 36 mm
Bond stress Ꚍbd = 1.4 N/mm2
Standard embedded length = 1000 mm
Custom embedded length = 0 mm
Bearing Plate dimenssion side-1 & side-2 = 100 mm 100 mm
Effective area of bearing plate = 100 * 100 - 3.14*36^2/4
= 8982.64 mm2
Force restricted by bearing plate = 11.25*8982.64 (0.45 fck * Area)
= 101.06 kN
Tensile force restricted by anchor bolt = 60.64 kN
= 3.14 * 36 * 1.4
= 158.256 N/mm
= 384 mm < 1000 mm SAFE
3 Shear Check for bolts
SHEAR KEY PROVIDED FOR COLUMN
Shear in each bolt (Case-I) = 30.47 kN < 150.28 kN
Shear in each bolt (Case-II) = 25 kN < 150.28 kN
Shear in each bolt (Case-III) = 37.71 kN < 150.28 kN SAFE
4 Combined Tension & Shear Check
Combined Tension +Shear (Case-I)
(0/221.98)^2 + (30.47/150.28)^2 = 0.04 < 1.00
Combined Tension +Shear (Case-II)
(161.7/221.98)^2 + (25/150.28)^2 = 0.56 < 1.00
Combined Tension +Shear (Case-III)
(0/221.98)^2 + (37.71/150.28)^2 = 0.06 < 1.00 SAFE
5 Plate thickness for maximum compression.
Max comp. pressure distributed under the base plate P1 = 1835.27/(600*400)
= 7.65 N/mm2
Bending Moments as per MUKANOV
Plate supported on three sides: length of free edge d1
Both dimensions are a = 200 b = 150 l = 150
a/b = 1.33
Coeff (α3) = 0.124 (coeff)
= Coeff * P * l^2
Pressure under the base plate = 7.65 N/mm2
= 0.124*7.65*150^2
Moment (M) = 21343.5 N-mm
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
= Sqrt(6*21343.5*10^6*1.1 / 1.2*240*1)
= 22.12 mm < 45 mm SAFE
6 Plate thickness for cantilever portion.
Length of cantilever portion (L) = 150 mm
Moment (M) P * l^2
Moment (M) = 86062.5 N-mm
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
effective width (b) = 1 mm (2l)
= Sqrt(6*86062.5*1.1 / 1.2*240*1)
= 44.42 mm < 45 mm SAFE
7 Plate thickness for maximum tension.
Moment (M) = 0.5p*l
Maximum force per bolt (p) = 161.7 kN
effective length (l) = 70 mm
Moment (M) = 0.5*161.7*70/1000
= 5.6595 kN-m
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
effective width (b) = 140.0 (2l)
= Sqrt(6*5.6595*10^6*1.1 / 1.2*240*140)
= 30.44 mm < 45 mm SAFE
8 Stiffener Bearing check for compression.
No.of stiffeners provided = 1
Bearing pressure under the stiffenes = 7.65 N/mm2
Effective length of the stiffener (Lws) = 185 mm
Effective load width on stiffener (bws) = 134 mm
Thickness of stiffener = 10 mm
Effective area = 185*134
= 24790 mm2
Load on Stiffener is = 7.65*24790
= 189.65 kN
Load bearing capacity of the stiffener (Fpsd) = Aq*fyd / (0.8* γm0) (as per cl.8.7.5.2, IS800:2007)
Area of the stiffener contact with base = 185*10
= 1850 mm2
= 1850*240 / (0.8*1.1)
= 504.55 kN > 189.65 kN SAFE
9 Stiffener height check for compression.
Bearing pressure under the stiffener = 7.65 N/mm2
Effective area = 24790 mm2
Moment for design of stiffener = Load on stiffener x stiffener length /2
= 189.65x1000 x 185/2
= 17.55 kN-m
Provided stiffener Height 'hs' and thickness 'ts' = 300 mm 10 mm
zs = ts*hs2/6
zs = 150000 mm3
Allowable Moment (M) = 1.2*fy*Z/1.1
= 39.24 kN-m > 17.55 kN-m SAFE
10 Stiffener Capacity check for Tension.
Maximum effective load on stiffener = 161.7 kN
Effective width of stiffener = 176.23 mm
Thickness of stiffener = 10 mm
Tension capacity of section (Tdg) = Ag*fy/γm0 (as per cl.6.2, IS800:2007)
= 384.51 kN > 161.7 kN SAFE
Moment at the face of the stiffener due to tension = 161.7*(450-300)/2
= 12.13 kN < 39.24 kN SAFE
11 Weld check from column to base plate for tension.
Max Comp. case Max Tension case Max Shear case
Axial Tension = 0 kN 1293.27 kN 0 kN
Design shear force = 243.7 kN 199.98 kN 301.63 kN
Flange width = 300 mm 300 mm 300 mm
Web depth = 268 mm 268 mm 268 mm
Web stiffner width (combined on either side) = 390 mm 390 mm 390 mm
No. of Web stiffeners = 1 1 1
Total weld area for the web in tension(A1) = 0.7*8*2*268 0.7*8*2*268 0.7*8*2*268
= 3001.6 mm2 3001.6 mm2 3001.6 mm2
Total weld area for the Flange(A2) = 0.7*8*2*300*2 0.7*8*2*300*2 0.7*8*2*300*2
= 6720 mm2 6720 mm2 6720 mm2
Total weld area for the web stiffener(A3) = 0.7*8*2*390*1 0.7*8*2*390*1 0.7*8*2*390*1
= 4368 mm2 4368 mm2 4368 mm2
Total Area (A1+A2+A3) = 14089.6 mm2 14089.6 mm2 14089.6 mm2
tensile Stress in the weld = 0 /14089.6 1293.27 /14089.6 0 /14089.6
= 0 N/mm2 91.79 N/mm2 0 N/mm2
Total weld area for the web in Shear(A3) = 3001.6 mm2 3001.6 mm2 3001.6 mm2
Shear Stress in the weld = 243.7 /3001.6 199.98 /3001.6 301.63 /3001.6
81.2 N/mm2 66.63 N/mm2 100.49 N/mm2
Allowable stress = 189.38 N/mm2 189.38 N/mm2 189.38 N/mm2
Sum of Shear and tensile stresses = 81.2 N/mm2 158.42 N/mm2 100.49 N/mm2 SAFE (cl.10.5.10.1.2.b)
equivalent of both tensile and shear stress (√fbt2+3q2) = check not req. check not req. check not req. SAFE
DESIGN OF SHEAR KEY 0
NOTE - Assuming that all the shear is transferred only through shear key
Allowable pressure in concrete= 13.5 N/mm^2
Bearing Strength of concrte =0.45 fck ,for M30 concrete
Max. Shear force Fx = 298.047 KN
Max. Shear force Fz = 154.41 KN
Presure due to Fx = 298047/(300x100) = 10 OK
N/mm^2
Grout 50mm Presure due to FHz = 154410/(300x100 )= 5.147 OK
N/mm^2
MOMENT Mx = (298.047x100) = 29.8047 KN m
50 MOMENT Mz = (154.41x100) = 15.441 KN m
100 Ix OF SHEAR KEY = 72819200 MM 4
Iy OF SHEAR KEY = 72819200 MM 4
300 Zx OF SHEAR KEY = 485461.4 MM 3
Zy OF SHEAR KEY = 485461.4 MM 3
32 fx,cal = 62.00 N/mm^2
fz,cal = 32 N/mm^2
f,all = 218.18 N/mm^2 permissible strees= fY/1.1
32 300 STRESS RATIO = 0.5 OK
PROVIDE shear key . 2 NOS 150x150x32mm thk. PL. AND 1-NO. 300x150x32mm thk. PL.
300
JOB No. Rev. No. 0 Date 24.05.2024
DQ.No. Rev. No. Date
Building Name JH KJ-9 Rev. No. Date
Client : Designed By Checked By
Summary of Unity checks
BASE PLATE FOR COL MKD C1 (AT ROW -AXIS A'1, A'2,Aa3 & Aa3') Checks Actual Allowable Unity Check
Tension Capacity of Bolt section area-kN 156.70 175.39 0.89
AB length w.r.t bond strength - mm 379.00 1000.00 0.38
DETAIL BP-2 REACTIONS = ACTUAL FORCE X 1.2 Shear Capacity of Bolt-kN 24.79 118.74 0.21
Node Reaction_Max Fy_compression case_Case-I
LC: 958 0.9 (DL+EQP) +B.T.+ 1.5 WL(+Z) (CPI-) axial and shear check
Combined 0.83 1.00 0.83
Shear-Fx (V) (Resultant of sqrt(Fx
66 + Fz) ) = 99.13 kN Plate thk. In compression(3 edge fix)- mm 12.24 36.00 0.34
Axial-Fy (P) = 758.11 kN Plate thk in tension - mm 29.97 36.00 0.83
P/A+M/Z -N/mm2 4.86 11.25 0.43
Node Reaction_Min Fy_Tension case_Case-II
LC: 912 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-Z) (CPI-)
Shear-Fx (V) (Resultant of sqrt(Fx
317
+ Fz) ) = 89.89 kN
Axial-Fy (P) = 626.77 kN
Node Reaction_Max Fx_Shear case_Case-III
LC: 943 0.9 (DL+EQP) +B.T.+ 1.5 WL(-X) (CPI+)
Shear-Fx (V) (Resultant of sqrt(Fx
317 + Fz) ) = 3.64 kN
Axial-Fy (P) = 758.11 kN (C)
COLUMN SECTION DETAILS
Web Depth x Thickness 181.2 mm 7.9 mm
Flange Width x Thickness 204.3 mm 12.5 mm STIFFENER DETAILS
Over all section depth 206.2 mm No.of stiffeners perpendicular to web (Sw) Yes 1
Dist. from compression flange to nearest web stiff. = 150 mm
BOLT DETAILS Flange stiffener Length (Lfs) = 136.05 mm
Anchor bolt grade = Grade 4.6 Flange stiffener height (Hfs) = 300 mm
Bolt diameter (d) = 32 mm Stiffener thickness (Tfs) = 10 mm
No.of bolt rows (nr) = 2
No.of bolts in each row (nb) = 2 STIFFENER DETAILS
Pitch (p) = 360 mm Grade of Concrete (fck) = M25
Gauge (g) = 150 mm Permissible Compression(0.45 fck) (IS456:2000, Cl.34.4) = 11.25 N/mm2
Edge Dist. for Bolt (ed) = 75 mm Bond Stress σbs (IS456:2000, Cl.26.2.1.1) = 1.4 N/mm2
Dist. for Boltfrom flange (eg) = 77 mm
Anchor bolt with bottom plt = YES
Bolt bottom plate width = 100 mm ACTUAL FORCES
958 0.9 (DL+EQP) +B.T.+ 1.5 WL(+Z) (CPI-)
Bolt bottom plate width = 100 mm Maxi Compression
Yield stress of bolt (fyb) = 240 N/mm2 Shear-Fx 0.33
Ultimate tensile stress of bolt (fub) = 410 N/mm2 Axial-Fy 758.10
Shear-Fz 99.13
912 (0.9 (DL+EQP) +B.T.+ 1.5 WL(-Z) (CPI-)
Maximum Tension
PLATE DETAILS Shear-Fx 0.07
Axial-Fy 626.76
Plate thickness (t) = 36 mm
Shear-Fz 89.88
Min Plate width = 300 mm Maximum shear 958 0.9 (DL+EQP) +B.T.+ 1.5 WL(+Z) (CPI-)
Plt Width increment = 0 mm Shear-Fx 3.63
Plate width (B) = 300 mm Axial-Fy 758.10
Length Ext (Le) = 156.9 mm Shear-Fz -99.13
Plate Length (L) = 520 mm
Base plate fy = 240 N/mm2
Base plate fu = 410 N/mm2 *Web stiffener (Sw) shown is indicative, its presence and location depends on
Connection detail = BP2R2BP design requirement.
SHEAR CAPACITY OF BOLT
Design Shear Strength of the Bolt ( V dsb) = Vnsb/γmb (IS 800:2007, Cl.10.3.3, Pg-75)
Vnsb = fub/√3 * (nn*Anb+ns*Asb)
Partial saftey Factor (γmb) = 1.25
No. of Shear Planes with Threads (nn) = 1 per bolt
No.of Shear Planes with out Threads (ns) = 0 per bolt
Nominal Plain shank area of Bolt ( Asb) = 803.84
Net shear Area of the Bolt at Threads (Anb) = 627.00 (0.78*Asb) ( IS4000:1992, Table-2)
fub/√3 * (nn*Anb+ns*Asb) = 410/√3 * (1*627 + 0*803.84)
= 148.42
Vdsb = 148.42/1.25
Vdsb = 118.74
TENSION CAPACITY OF BOLT
DesignTensile Capacity of the Bolt ( T db) = Tnb/γmb (IS 800:2007, Cl.10.3.5, Pg-76)
Nominal Tensile Capacity of Bolt ( T nb) = 0.9 fub *An < fyb * Asb * (γmb/γm0)
Partial saftey Factor (γmb) = 1.25
Partial saftey Factor (γmo) = 1.10
0.9 fub *Anb = 0.9*410*627
= 231 kN
fyb * Asb * (γmb/γm0) = 240*803.84*(1.25/1.1)
= 219 kN
Tnb = 219 kN
Tdb = 175 kN
1 Tension Check w.r.t bolt cross section
No.of bolts in tension side = 4
Tension in each bolt (Case-I) = 0 kN < 175.39 kN
Tension in each bolt (Case-II) = 156.7 kN < 175.39 kN
Tension in each bolt (Case-III) = 0 kN < 175.39 kN SAFE
Max tension in bolt = 156.7 kN
2 Tension Check w.r.t bond strength of concrete.
Anchor bolt dia (d) = 32 mm
Bond stress Ꚍbd = 1.4 N/mm2
Standard embedded length = 1000 mm
Custom embedded length = 0 mm
Bearing Plate dimenssion side-1 & side-2 = 100 mm 100 mm
Effective area of bearing plate = 100 * 100 - 3.14*32^2/4
= 9196.16 mm2
Force restricted by bearing plate = 11.25*9196.16 (0.45 fck * Area)
= 103.46 kN
Tensile force restricted by anchor bolt = 53.24 kN
= 3.14 * 32 * 1.4
= 140.672 N/mm
= 379 mm < 1000 mm SAFE
3 Shear Check for bolts
SHEAR KEY PROVIDED FOR COLUMN
Shear in each bolt (Case-I) = 24.79 kN < 118.736 kN
Shear in each bolt (Case-II) = 22.48 kN < 118.736 kN
Shear in each bolt (Case-III) = 0.91 kN < 118.736 kN SAFE
4 Combined Tension & Shear Check
Combined Tension +Shear (Case-I)
(0/175.39)^2 + (24.79/118.736)^2 = 0.04 < 1.00
Combined Tension +Shear (Case-II)
(156.7/175.39)^2 + (22.48/118.736)^2 = 0.83 < 1.00
Combined Tension +Shear (Case-III)
(0/175.39)^2 + (0.91/118.736)^2 = 0.00 < 1.00 SAFE
5 Plate thickness for maximum compression.
Max comp. pressure distributed under the base plate P1 = 758.11/(520*300)
= 4.86 N/mm2
Bending Moments as per MUKANOV
Plate supported on three sides: length of free edge d1
Both dimensions are a = 150 b = 103.1 l = 103.1
a/b = 1.45
Coeff (α3) = 0.127 (coeff)
= Coeff * P * l^2
Pressure under the base plate = 4.86 N/mm2
= 0.1265*4.86*103.1^2
Moment (M) = 6534.98 N-mm
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
= Sqrt(6*6534.98*10^6*1.1 / 1.2*240*1)
= 12.24 mm < 36 mm SAFE
6 Plate thickness for cantilever portion.
Length of cantilever portion (L) = 150 mm
Moment (M) P * l^2
Moment (M) = 54675 N-mm
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
effective width (b) = 1 mm (2l)
= Sqrt(6*54675*1.1 / 1.2*240*1)
= 35.4 mm < 36 mm SAFE
7 Plate thickness for maximum tension.
Moment (M) = 0.5p*l
Maximum force per bolt (p) = 156.7 kN
effective length (l) = 70 mm
Moment (M) = 0.5*156.7*70/1000
= 5.4845 kN-m
Thickness of Base plate (t) = Sqrt( 6 * M * γm0 / 1.2 * fy * b)
γm0 = 1.1
effective width (b) = 140.0 (2l)
= Sqrt(6*5.4845*10^6*1.1 / 1.2*240*140)
= 29.97 mm < 36 mm SAFE
8 Stiffener Bearing check for compression.
No.of stiffeners provided = 1
Bearing pressure under the stiffenes = 4.86 N/mm2
Effective length of the stiffener (Lws) = 136.05 mm
Effective load width on stiffener (bws) = 90.6 mm
Thickness of stiffener = 10 mm
Effective area = 136.05*90.6
= 12326.13 mm2
Load on Stiffener is = 4.86*12326.13
= 59.91 kN
Load bearing capacity of the stiffener (Fpsd) = Aq*fyd / (0.8* γm0) (as per cl.8.7.5.2, IS800:2007)
Area of the stiffener contact with base = 136.05*10
= 1360.5 mm2
= 1360.5*240 / (0.8*1.1)
= 371.05 kN > 59.91 kN SAFE
9 Stiffener height check for compression.
Bearing pressure under the stiffener = 4.86 N/mm2
Effective area = 12326.13 mm2
Moment for design of stiffener = Load on stiffener x stiffener length /2
= 59.91x1000 x 136.05/2
= 4.08 kN-m
Provided stiffener Height 'hs' and thickness 'ts' = 300 mm 10 mm
zs = ts*hs2/6
zs = 150000 mm3
Allowable Moment (M) = 1.2*fy*Z/1.1
= 39.24 kN-m > 4.08 kN-m SAFE
10 Stiffener Capacity check for Tension.
Maximum effective load on stiffener = 156.7 kN
Effective width of stiffener = 164.71 mm
Thickness of stiffener = 10 mm
Tension capacity of section (Tdg) = Ag*fy/γm0 (as per cl.6.2, IS800:2007)
= 359.37 kN > 156.7 kN SAFE
Moment at the face of the stiffener due to tension = 156.7*(360-206.2)/2
= 12.06 kN < 39.24 kN SAFE
11 Weld check from column to base plate for tension.
Max Comp. case Max Tension case Max Shear case
Axial Tension = 0 kN 626.77 kN 0 kN
Design shear force = 99.13 kN 89.89 kN 3.64 kN
Flange width = 204.3 mm 204.3 mm 204.3 mm
Web depth = 181.2 mm 181.2 mm 181.2 mm
Web stiffner width (combined on either side) = 292.1 mm 292.1 mm 292.1 mm
No. of Web stiffeners = 1 1 1
Total weld area for the web in tension(A1) = 0.7*8*2*181.2 0.7*8*2*181.2 0.7*8*2*181.2
= 2029.44 mm2 2029.44 mm2 2029.44 mm2
Total weld area for the Flange(A2) = 0.7*8*2*204.3*2 0.7*8*2*204.3*2 0.7*8*2*204.3*2
= 4576.32 mm2 4576.32 mm2 4576.32 mm2
Total weld area for the web stiffener(A3) = 0.7*8*2*292.1*1 0.7*8*2*292.1*1 0.7*8*2*292.1*1
= 3271.52 mm2 3271.52 mm2 3271.52 mm2
Total Area (A1+A2+A3) = 9877.28 mm2 9877.28 mm2 9877.28 mm2
tensile Stress in the weld = 0 /9877.28 626.77 /9877.28 0 /9877.28
= 0 N/mm2 63.46 N/mm2 0 N/mm2
Total weld area for the web in Shear(A3) = 2029.44 mm2 2029.44 mm2 2029.44 mm2
Shear Stress in the weld = 99.13 /2029.44 89.89 /2029.44 3.64 /2029.44
48.85 N/mm2 44.3 N/mm2 1.8 N/mm2
Allowable stress = 189.38 N/mm2 189.38 N/mm2 189.38 N/mm2
Sum of Shear and tensile stresses = 48.85 N/mm2 107.76 N/mm2 1.8 N/mm2 SAFE (cl.10.5.10.1.2.b)
equivalent of both tensile and shear stress (√fbt2+3q2) = check not req. check not req. check not req. SAFE
DESIGN OF SHEAR KEY 0
NOTE - Assuming that all the shear is transferred only through shear key
Allowable pressure in concrete= 13.5 N/mm^2
Bearing Strength of concrte =0.45 fck ,for M30 concrete
Max. Shear force Fx = 3.631 KN
Max. Shear force Fz = 89.882 KN
Presure due to Fx = 3631/(250x100) = 0.15 OK
N/mm^2
Grout 50mm Presure due to FHz = 89882/(250x100 )= 3.59528 OK
N/mm^2
MOMENT Mx = (3.631x100) = 0.3631 KN m
50 MOMENT Mz = (89.882x100) = 8.9882 KN m
100 Ix OF SHEAR KEY = 32877604.2 CM 4
Iy OF SHEAR KEY = 32877604.2 CM 4
250 Zx OF SHEAR KEY = 263020.9 CM 3
Zy OF SHEAR KEY = 263020.9 CM 3
25 fx,cal = 1.00 N/mm^2
fz,cal = 1 N/mm^2
f,all = 218.18 N/mm^2 permissible strees= fY/1.1
25 250 STRESS RATIO = 0.1 OK
PROVIDE shear key . 2 NOS 125x150x25mm thk. PL. AND 1-NO. 250x150x25mm thk. PL.
250