Isolated Footing(F2)
1 Footing Size Design
Load Pu 614 KN
Design Load P 450 KN
Moment in x dir Mux -7 KN-m
Moment in y dir Muy -1 KN-m
Column size cx 300 mm
cy 300 mm
SBC q 150 KN/sqm
Footing Size required A req 3.00 sqmm
L 1.80 meters
Footing Size Provided
B 1.80 meters
Area Provided A prvd 3.24 meters
Zx 0.97
Zx 0.97
Net upward pressure Nup 134 KNm2
Footing Size OK
2 Slab Design
lx 0.750
ly 0.750
Bending Moment in x dir Mx 56 KN-m
Bending Moment in y dir My 56 KN-m
Concrete fck 20 MPa
Steel fy 500 MPa
Minimum Depth Required dmin 146
Depth Provided D 500 mm
Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 444 mm
Spacing c/c in mm
Area of Steel
12# 16# 20#
317 sqmm 357 c/c 635 c/c 992 c/c
317 sqmm 357 c/c 635 c/c 992 c/c
Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm
Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
3 One Way Shear along x direction
Vu1 110 KN
ζv 0.138 MPa
ζc 0.205 MPa
Vc1 164 KN
One Way Shear Check OK
4 One Way Shear along y direction
Vu1 110 KN
ζv 0.138 MPa
ζc 0.205 MPa
Vc1 164 KN
One Way Shear Check OK
5 Two Way Shear
Vu2 539 KN
ζv 0.408 MPa
ks*ζc 1.118 MPa
Vc1 1477 KN
Two Way Shear Check OK
L= 1.80 meters
300
300
B= 1.80 meters
500 mm
250 mm
12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c