You are on page 1of 2

Project

Footing No.
Date 20-Dec-22
Footing No. CF1

1 Footing Size Design

Load 1 Pu1 900 KN 60 TONS


Load 2 Pu2 675 KN 45 TONS
Combine load Pcu 1575 KN 105 TONS
Design Load Pc 1155 KN 116 TONS

c/c dist b/w col in x dir 2.700 meters


c/c dist b/w col in y dir 0.000 meters

Col Dim x dir 0.50 meters


y dir 0.20 meters

SBC q 150 KNm2

Footing Size required A req 7.70 sqmm

L 4.70 meters
Footing Size Provided
B 1.70 meters
Area Provided A prvd 7.99 meters

x bar 1.157
y bar 0.000

Zx 2.26
Zx 6.26

Nup 145 KNm2

Footing Size OK

2 Slab Design

Net upward pressure Nup 145 KNm2


l 0.75 meters /=width of footing from col face

Bending Moment Ms 40.7 KN-m M=Nup*l2/2


Factored Moment Mus 61 KN-m 1.5*Ms

Concrete fck 30 MPa


Steel fy 415 MPa

Minimum Depth Required dmin 121 d=sqrt(Ms/Rumax*1000*b)

Depth Provided D 550 mm


Clear Cover c 75 mm
Effective Cover d' 83 mm
Effective Depth d' 467 mm

Area of Steel across x dir Spacing c/c in mm


12# 16# 20#
560 sqmm 202 c/c 359 c/c 561 c/c
Minimum Ast required across x direcion

Ast across x direction 16 mm dia @ 142 mm c/c 1416 sqmm


Dist Ast across y direction 16 mm dia @ 142 mm c/c 1416 sqmm

4 Shear Check for Slab

Vu1 61 KN
ζv 0.131 MPa

ζc 0.265 MPa

Shear Check OK
Project
Footing No.
Date 20-Dec-22
Footing No. CF2

1 Footing Size Design

Load 1 Pu1 1125 KN 75 TONS


Load 2 Pu2 900 KN 60 TONS
Combine load Pcu 2025 KN 135 TONS
Design Load Pc 1485 KN 149 TONS

c/c dist b/w col in x dir 2.000 meters


c/c dist b/w col in y dir 0.000 meters

Col Dim x dir 0.20 meters


y dir 0.50 meters

SBC q 150 KNm2

Footing Size required A req 9.90 sqmm

L 4.20 meters
Footing Size Provided
B 2.50 meters
Area Provided A prvd 10.50 meters

x bar 0.889
y bar 0.000

Zx 4.38
Zx 7.35

Nup 141 KNm2

Footing Size OK

2 Slab Design

Net upward pressure Nup 141 KNm2


l 1.15 meters /=width of footing from col face

Bending Moment Ms 93.5 KN-m M=Nup*l2/2


Factored Moment Mus 140 KN-m 1.5*Ms

Concrete fck 30 MPa


Steel fy 415 MPa

Minimum Depth Required dmin 184 d=sqrt(Ms/Rumax*1000*b)

Depth Provided D 550 mm


Clear Cover c 75 mm
Effective Cover d' 82 mm
Effective Depth d' 468 mm

Area of Steel across x dir Spacing c/c in mm


12# 16# 20#
852 sqmm 133 c/c 236 c/c 369 c/c

Ast across x direction 14 mm dia @ 150 mm c/c 1026 sqmm


Dist Ast across y direction 14 mm dia @ 150 mm c/c 1026 sqmm

4 Shear Check for Slab

Vu1 145 KN
ζv 0.309 MPa

ζc 0.320 MPa

Shear Check OK

You might also like