You are on page 1of 32

Grade of concrete 25 Mpa

Grade of steel 500 Mpa y1 Y


Qlim 3.33
Factored load Pu 274 KN Col dimension B 230 mm
Mx 6 KNm D 450 mm
My 0.28 KNm

Load factor 1.5 X


P 200.93 KN
Mx 4 KNm
My 0.1867 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
0.4421 m2 P/A+My/Z
292
ex 21.898 mm y1
ey 1.0219 mm 0.5
291 289
Provide footing dimensions L 0.95 m cantilever portion 0.5
B 0.73 m
Area provided 0.6935 m2
Zx 0.1098 m3
Zy 0.08438 m3

Pressure check
P/A+Mx/Zx+My/Zy 328.379 < 500 SAFE

P/A-Mx/Zx-My/Zy 251.097 > 0 SAFE

Moment Calculations
Mx 29.4591 KNm
My 34.5618 KNm
Mux 44.1887 KNm dreq 134.8 Dreq 195
Muy 51.8427 KNm dreq 128 Dprov 350
dprov 290
Reinforcement along Y-Y dia spacing
Pt 0.17142 % Provide 10 140
Ast,req 362.904 mm2 Ast prov 487.821429

Reinforcement along X-X dia spacing


Pt 0.15399 % Provide 10 140
Ast,req 424.231 mm2 Ast prov 611.178571
One way shear
About x1-x1 V 48.7669 KN About y1-y1 V 58.117132
Vu 73.1503 KN Vu 87.175698
Tv 0.34554 N/mm2 Tv 0.3164272
Pt, prov 0.23043 Pt,prov 0.2218434
Tc 0.35201 Tc 0.3462011
B 12.5971 B 13.084715
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 231.692
perimeter 2520
Tv 0.31704 N/mm2
SAFE
P/A-Mx/Z 253.30955

L
X
288

0.5 x1 310

B P/A+Mx/Z 326.16653

P/A-My/Z
288

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 410 KN Col dimension B 230 mm
Mx 17.77 KNm D 450 mm
My 1.03 KNm

Load factor 1.5 X


P 300.67 KN
Mx 11.847 KNm
My 0.6867 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
0.6615 m2 P/A+My/Z
350.7
ex 43.341 mm L/6 175 mm y1
ey 2.5122 mm 0.6
348 342
Provide footing dimensions L 1.05 m cantilever portion 0.5
B 0.83 m
Area provided 0.8715 m2
Zx 0.15251 m3
Zy 0.12056 m3

Pressure check
P/A+Mx/Zx+My/Zy 428.371 < 500 SAFE

P/A-Mx/Zx-My/Zy 261.627 > 0 SAFE

Moment Calculations
Mx 60.5378 KNm
My 65.7131 KNm
Mux 90.8067 KNm dreq 181.3 Dreq 241
Muy 98.5697 KNm dreq 167.9 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.17131 % Provide 10 100
Ast,req 554.526 mm2 Ast prov 730.05

Reinforcement along X-X dia spacing


Pt 0.14623 % Provide 10 100
Ast,req 598.822 mm2 Ast prov 902.75
One way shear
About x1-x1 V 70.9646 KN About y1-y1 V 77.010443
Vu 106.447 KN Vu 115.51566
Tv 0.32884 N/mm2 Tv 0.2820895
Pt, prov 0.22553 Pt,prov 0.2204518
Tc 0.34871 Tc 0.3452466
B 12.8707 B 13.167314
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 383.848
perimeter 2920
Tv 0.33706 N/mm2
SAFE
P/A-Mx/Z 267.32235

L
X
334

0.6 x1 392

B P/A+Mx/Z 422.67574

P/A-My/Z
339

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 699.53 KN Col dimension B 230 mm
Mx 3.36 KNm D 450 mm
My 1.91 KNm

Load factor 1.5 X


P 513 KN
Mx 2.24 KNm
My 1.2733 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
1.1286 m2 P/A+My/Z
381.3
ex 4.8032 mm L/6 275 mm y1
ey 2.7304 mm 0.6
378 372
Provide footing dimensions L 1.65 m cantilever portion 0.5
B 0.83 m
Area provided 1.3695 m2
Zx 0.37661 m3
Zy 0.18945 m3

Pressure check
P/A+Mx/Zx+My/Zy 387.25 < 500 SAFE

P/A-Mx/Zx-My/Zy 361.912 > 0 SAFE

Moment Calculations
Mx 56.7238 KNm
My 111.527 KNm
Mux 85.0857 KNm dreq 175.5 Dreq 235
Muy 167.29 KNm dreq 174.5 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.16015 % Provide 10 100
Ast,req 518.391 mm2 Ast prov 730.05

Reinforcement along X-X dia spacing


Pt 0.15833 % Provide 10 100
Ast,req 1018.85 mm2 Ast prov 1373.75
One way shear
About x1-x1 V 66.1942 KN About y1-y1 V 131.532
Vu 99.2913 KN Vu 197.29799
Tv 0.30674 N/mm2 Tv 0.3066014
Pt, prov 0.22553 Pt,prov 0.213481
Tc 0.34871 Tc 0.3404073
B 12.8707 B 13.597267
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 636.276
perimeter 2920
Tv 0.55873 N/mm2
SAFE
P/A-Mx/Z 368.63323

0.6

L
X
376

0.6 x1 379

B P/A+Mx/Z 380.52875

P/A-My/Z
368

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 602.2 KN Col dimension B 230 mm
Mx 8.53 KNm D 450 mm
My 1.53 KNm

Load factor 1.5 X


P 441.61 KN
Mx 5.6867 KNm
My 1.02 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
0.9715 m2 P/A+My/Z
297
ex 14.165 mm L/6 175 mm y1
ey 2.5407 mm 0.6
296 295
Provide footing dimensions L 1.05 m cantilever portion 0.5
B 1.43 m
Area provided 1.5015 m2
Zx 0.26276 m3
Zy 0.35786 m3

Pressure check
P/A+Mx/Zx+My/Zy 318.607 < 500 SAFE

P/A-Mx/Zx-My/Zy 269.623 > 0 SAFE

Moment Calculations
Mx 77.8774 KNm
My 55.9614 KNm
Mux 116.816 KNm dreq 156.6 Dreq 217
Muy 83.942 KNm dreq 154.9 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.12674 % Provide 10 100
Ast,req 706.832 mm2 Ast prov 1201.05

Reinforcement along X-X dia spacing


Pt 0.12396 % Provide 10 100
Ast,req 507.628 mm2 Ast prov 902.75
One way shear
About x1-x1 V 93.5219 KN About y1-y1 V 65.388502
Vu 140.283 KN Vu 98.082753
Tv 0.25154 N/mm2 Tv 0.2395183
Pt, prov 0.21536 Pt,prov 0.2204518
Tc 0.34172 Tc 0.3452466
B 13.4788 B 13.167314
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 586.575
perimeter 2920
Tv 0.51508 N/mm2
SAFE
P/A-Mx/Z 272.47292

L
X
291

0.6 x1 307

B P/A+Mx/Z 315.75662

P/A-My/Z
291

0.6

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 1114 KN Col dimension B 300 mm
Mx 0 KNm D 600 mm
My 3.78 KNm

Load factor 1.5 X


P 816.93 KN
Mx 0 KNm
My 2.52 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
1.7973 m2 P/A+My/Z
398.3
ex 0 mm L/6 267 mm y1
ey 3.3932 mm 0.5
397 394
Provide footing dimensions L 1.6 m cantilever portion 0.5
B 1.3 m
Area provided 2.08 m2
Zx 0.55467 m3
Zy 0.45067 m3

Pressure check
P/A+Mx/Zx+My/Zy 398.348 < 500 SAFE

P/A-Mx/Zx-My/Zy 387.165 > 0 SAFE

Moment Calculations
Mx 63.8229 KNm
My 79.1678 KNm
Mux 95.7344 KNm dreq 148.7 Dreq 209
Muy 118.752 KNm dreq 149.3 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.11396 % Provide 10 100
Ast,req 577.755 mm2 Ast prov 1099

Reinforcement along X-X dia spacing


Pt 0.11487 % Provide 10 100
Ast,req 716.799 mm2 Ast prov 1334.5
One way shear
About x1-x1 V 56.1642 KN About y1-y1 V 70.025997
Vu 84.2462 KN Vu 105.03899
Tv 0.16617 N/mm2 Tv 0.1683317
Pt, prov 0.21677 Pt,prov 0.2138622
Tc 0.3427 Tc 0.3406745
B 13.3912 B 13.573029
SAFE

Two way shear


Bc= short side of column 0.5
long side of column
Ks=(0.5+Bc) 1 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 1007.71
perimeter 3360
Tv 0.76901 N/mm2
SAFE
P/A-Mx/Z 392.75641

0.5

L
X
393

0.5 x1 393

B P/A+Mx/Z 392.75641

P/A-My/Z
387

0.5

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 801 KN Col dimension B 300 mm
Mx 5.13 KNm D 600 mm
My 9.19 KNm

Load factor 1.5 X


P 587.4 KN
Mx 3.42 KNm
My 6.1267 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
1.2923 m2 P/A+My/Z
387.8
ex 6.4045 mm L/6 300 mm y1
ey 11.473 mm 0.6
376 354
Provide footing dimensions L 1.8 m cantilever portion 0.5
B 0.9 m
Area provided 1.62 m2
Zx 0.486 m3
Zy 0.243 m3

Pressure check
P/A+Mx/Zx+My/Zy 394.842 < 500 SAFE

P/A-Mx/Zx-My/Zy 330.343 > 0 SAFE

Moment Calculations
Mx 59.683 KNm
My 118.791 KNm
Mux 89.5244 KNm dreq 172.8 Dreq 233
Muy 178.187 KNm dreq 172.4 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.15524 % Provide 10 100
Ast,req 544.882 mm2 Ast prov 785 mm2

Reinforcement along X-X dia spacing


Pt 0.15446 % Provide 10 100
Ast,req 1084.34 mm2 Ast prov 1491.5 mm2
One way shear
About x1-x1 V 69.7048 KN About y1-y1 V 144.36662
Vu 104.557 KN Vu 216.54993
Tv 0.29788 N/mm2 Tv 0.3084757
Pt, prov 0.22365 Pt,prov 0.2124644
Tc 0.34743 Tc 0.3396934
B 12.9792 B 13.662326
SAFE

Two way shear


Bc= short side of column 0.5
long side of column
Ks=(0.5+Bc) 1 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 726.396
perimeter 3360
Tv 0.55433 N/mm2
SAFE
P/A-Mx/Z 355.55556

0.6

L
X
365

0.6 x1 368

B P/A+Mx/Z 369.62963

P/A-My/Z
337

mm
SAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 490 KN Col dimension B 230 mm
Mx 1.27 KNm D 450 mm
My 12.82 KNm

Load factor 1.5 X


P 359.33 KN
Mx 0.8467 KNm
My 8.5467 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
0.7905 m2 P/A+My/Z
483.2
ex 2.5918 mm L/6 175 mm y1
ey 26.163 mm 0.6
447 381
Provide footing dimensions L 1.05 m cantilever portion 0.5
B 0.83 m
Area provided 0.8715 m2
Zx 0.15251 m3
Zy 0.12056 m3

Pressure check
P/A+Mx/Zx+My/Zy 488.76 < 500 SAFE

P/A-Mx/Zx-My/Zy 335.872 > 0 SAFE

Moment Calculations
Mx 62.2429 KNm
My 84.2543 KNm
Mux 93.3643 KNm dreq 183.8 Dreq 250
Muy 126.381 KNm dreq 190.1 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.17632 % Provide 10 100
Ast,req 570.736 mm2 Ast prov 730.05 mm2

Reinforcement along X-X dia spacing


Pt 0.18917 % Provide 12 125
Ast,req 774.633 mm2 Ast prov 1062.576 mm2
One way shear
About x1-x1 V 72.6408 KN About y1-y1 V 102.59249
Vu 108.961 KN Vu 153.88873
Tv 0.33661 N/mm2 Tv 0.3757967
Pt, prov 0.22553 Pt,prov 0.2594813
Tc 0.34871 Tc 0.3706958
B 12.8707 B 11.186769
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 437.96
perimeter 2920
Tv 0.38458 N/mm2
SAFE
P/A-Mx/Z 406.76447

L
X
412

0.6 x1 416

B P/A+Mx/Z 417.86739

P/A-My/Z
341

mm
UNSAFE
Grade of concrete 25 Mpa
Grade of steel 500 Mpa y1 Y
Qlim 3.33
Factored load Pu 328 KN Col dimension B 230 mm
Mx 1.27 KNm D 450 mm
My 1.7 KNm

Load factor 1.5 X


P 240.53 KN
Mx 0.8467 KNm
My 1.1333 KNm x1
SBC of soil 500 KN/m2
Y
Area of footing required =P + 10% self weight of footing
0.5292 m2 P/A+My/Z
285.4
ex 3.872 mm L/6 175 mm y1
ey 5.1829 mm 0.6
281 272
Provide footing dimensions L 1.05 m cantilever portion 0.5
B 0.83 m
Area provided 0.8715 m2
Zx 0.15251 m3
Zy 0.12056 m3

Pressure check
P/A+Mx/Zx+My/Zy 290.951 < 500 SAFE

P/A-Mx/Zx-My/Zy 261.047 > 0 SAFE

Moment Calculations
Mx 41.8771 KNm
My 53.0028 KNm
Mux 62.8157 KNm dreq 150.8 Dreq 211
Muy 79.5042 KNm dreq 150.8 Dprov 450
dprov 390
Reinforcement along Y-Y dia spacing
Pt 0.11719 % Provide 10 100
Ast,req 379.343 mm2 Ast prov 730.05 mm2

Reinforcement along X-X dia spacing


Pt 0.11725 % Provide 10 100
Ast,req 480.13 mm2 Ast prov 902.75 mm2
One way shear
About x1-x1 V 48.8808 KN About y1-y1 V 62.40624
Vu 73.3211 KN Vu 93.60936
Tv 0.22651 N/mm2 Tv 0.2285943
Pt, prov 0.22553 Pt,prov 0.2204518
Tc 0.34871 Tc 0.3452466
B 12.8707 B 13.167314
SAFE

Two way shear


Bc= short side of column 0.51111
long side of column
Ks=(0.5+Bc) 1.01111 > 1
Ks=(0.5+Bc) 1
Tc=0.25sqrt(fck) 1.25 N/mm2

Design shear strength=KsTc 1.25 N/mm2

Vu 260.711
perimeter 2920
Tv 0.22893 N/mm2
SAFE
P/A-Mx/Z 270.44778

L
X
275

0.6 x1 279

B P/A+Mx/Z 281.55069

P/A-My/Z
267

mm
SAFE

You might also like