0% found this document useful (0 votes)
826 views1 page

Psychrometric Chart

The document presents ASHRAE Psychrometric Chart No. 1, which is designed for normal temperature conditions at a barometric pressure of 101.325 kPa. It includes various thermodynamic properties such as sensible heat, total heat, enthalpy, and humidity ratios relevant to air conditioning and refrigeration. The chart is prepared by the Center for Applied Thermodynamic Studies at the University of Idaho and is a reprint from the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
826 views1 page

Psychrometric Chart

The document presents ASHRAE Psychrometric Chart No. 1, which is designed for normal temperature conditions at a barometric pressure of 101.325 kPa. It includes various thermodynamic properties such as sensible heat, total heat, enthalpy, and humidity ratios relevant to air conditioning and refrigeration. The chart is prepared by the Center for Applied Thermodynamic Studies at the University of Idaho and is a reprint from the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ASHRAE Psychrometric Chart No.

1
Normal Temperature
Barometric Pressure: 101.325 kPa

1992 American Society of Heating, 0.36


Refrigerating and Air-Conditioning Engineers, Inc.
30
Sea Level
100 28 0.40

0.9
4
30
Σ 1.0 1.0 –Σ
0.8 1.5
120
10.0 0.7 2.0 – 5.0
0.6 4.0 – 2.0 26
Sensible heat DH – Σ 90
0.5 —————– = ——S – 4.0 30
Total heat DHT – 2.0 0.0
5.0 0.4 1.0 0.45

3
–0
24

0.
1.0

.5
4.0

0.2
– 0.2

0.1
0 80

0.9
110
DHS
DHT

r
ai 22

2.0
y

2 vo
0.50

3.0
dr

lu

2.5
am
r

me
Enthalpy Dh og
il 25
cu
—————— = —— k 70
Humidity ratio D er 20
sp bic 0.55
Total heat

le
Sensible heat

met
—————– = ——

ou
e

j 100
ilo 25

%
r pe

)k wet 18

90
(h 60 bul
b 0.60
r ki

0.9
lp tem

0
log

ha per

%
nt a
ra

ture

80
E °C
°C 16 0.65
md

re

%
a tu
ry a

50 20

70
er
ir

p 90 0.70
m
te 14
ion %
rat 60 0.75

0.8
tu 20

8
40 Sa 0.80
% 12
Humidity ratio ( ) grams moisture per kilogram dry air

50 0.85
15 80 0.90
% 10 0.95
30 40

0.8
6
15 1.0

10 30% 8
20 70

0.8
4
10
6
5 20%

0.8
5

2
y 4
umidit
lative h
0 10% re 60

0.8
0

0.7
2

8
0 10 20 30 40 50
927

Dry bulb temperature °C


APPENDIX 1

Prepared by Center for Applied Thermodynamic Studies, University of Idaho.

FIGURE A–31
Psychrometric chart at 1 atm total pressure.
Reprinted from American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.