Title: 062/125 Tyna-Myte Solenoid Valves


ISO Date: October 31, 1997

Dont Take Chances


Compressed air is an extremely powerful medium. Always take maximum precautions when
handling any component of a compressed air system. Never attempt to construct, replace,
operate or service any component of a compressed air system unless you have been
specifically and properly trained to do so. Always disconnect the supply air and exhaust the
air system before attempting to remove or service a component of that system Failure to
heed these warnings could result in SERIOUS, EVEN FATAL, PERSONAL INJURY.
Design And Specifications
The design and specifications and other product information contained in this catalog is for
general reference purposes based upon customary and usual manufacturing standards and
product applications. However, it is difficult to predict or to anticipate the functioning or
suitability of the product for any particular application or use. Therefore, nothing herein
shall be deemed a representation or warranty of the product design or specifications and
Buyer shall have the responsibility for investigating and testing the product in any particular
application or use and all risks attendant in such use.

Humphrey Products Company


1-800-477-8707
Kalamazoo MI 49003
http://www.humphreypc.com/air/

Overrride located 0.81 (20.6)


from bottom of valve body

30

45

2.5
(63.5)1.25

CYL.

(31.8)

2.5
(63.5)
1.25
(31.8)

IN

EXH

1.53
(38.9)

1/2 NPSI

3.50
(88.9)
2.88 E2
2.25
(57.2) E2 (73.0)
E1
1.94
(49.2) E1
0.69
(17.5)

062/125 Tyna-Myte
12/22/97

1.63
(41.3)
0.45 1/4 NPT
(11.5) TYP

1.53
(38.9)
1/2 NPSI

4 places
1/4 NPT
0.59
(15.1)
.38 (9.5)

0.06 (1.6)

EXH

IN

10-32 x 0.38 (9.5) deep on


0.88 (22.2) square centers valve body
0.22 (5.5) on
0.22 (5.5) on
2.00 (50.8) square centers
2.00 (50.8) square centers
1.63
(41.3)
Cover rotates 360
3 places
0.56
1/4 NPT 1/2 NPSI (14.3)
0.38 (9.5)
CYL EXH
0.31 (7.9)
IN

Overrride located 0.81 (20.6)


from bottom of valve body

0.31 (7.9)

0.06 (1.6)

1.63
(41.3)

Bottom View
0.48
(12.3)
2.66
(67.5)
0.31
(7.9)
10-32 x 0.38 (9.5) DP

3.50

2.25
2.88 (88.9)
(57.2) [E2] (73.0) [E2]
[E1]
1.94
(49.2) [E1]

See following Pages for more


Tyna-Myte Air Valve Models and
all specifications. Consult
factory for air piloted vacuum
options.

121

0.56
(14.3)

22.00
(558.8)
Min.

1/2-14 NPS
Rotates 110

T125 SERIES
T062/T062-4 SERIES

mounting holes
0.20 (5.2)

0.16 (4.0)
1.38
(34.9)

0.47
(11.9)

0.47
(11.9)

0.91
(23.0)

0.33 (8.4)
depth 1.7 (4.4)

CYL 2

IN
CYL 1

1.06 1.03
(26.8) (26.1)

10-32 x 0.28 (7.1)


counterbore 0.20 (5.0)
depth 0.13 (3.2)

TO PORT 1
INLET
TO PORT 2

0.80
(20.2)
0.50
(12.7)

0.56
(14.3)

0.41
0.41
(10.3)
(10.3)
2 places 10-32 0.31 (7.9) screws 1.16

062/125 Tyna-Myte
12/22/97

125-4E1-36
Shown
4 way single sol.

1.24
(31.4)

1.38
(34.9)
0.62
(15.7)

T062-4E1-70-80
Shown
4 way single sol.

1.06
(27.0)

0.98
(25.0)

CYL 2

0.62
(15.7)
T062E1-3-10-36-80
Shown
3 way single sol.

1/4 NPT
Ea. end

0.28
(7.2)

CYL 1

1.72
(43.7)

4.72
(119.9)
4.09 [E2]
(104.0)
[E1] 4.50
(114.3)
0.38
[125E2]
(9.5)

0.38
(9.5)

T125-4 SERIES

0.38
(9.5)
2.38
(60.3)

2.41
(61.1)
1.59
(40.5)

4 places
1/8 NPT

1.25
(31.8)

0.10
(27.8)
(2.6)
2.19 (55.6) for 1 station add 2.38 (60.3) per additional station/s

122

Tyna - Myte Series Manifold and valves shown


with optional Model JB junction boxes.

062/125 Tyna-Myte
12/22/97

123

062/125 Tyna-Myte
12/22/97

124