CABLEMASTERREMOTECONTROLWIRINGDIAGRAM
WHITE
OUT OFF IN
UNIT-#1 (Channels1&2)
CABLEMASTER RELAY ASSEMBLY # 04034 - (12, 24 volt DC) 12/24 Power DC Input Switch Pos. + Red 1
(Remote - RED) (Remote - BLACK) (Rmt - Yellow or Purple) (Rmt - Green or Tan)
RED BLACK
(seenote-1)
BATERY POSITIVE(+)
POWER SWITCH
RED WHITE BLACK (Remote-Red) (Remote-Yellow) (Remote-Green)
BATTERY NEGATIVE(-)
(Remote-Black)
Neg. -
White 2 Black 3
Motor Output M1 M2
IN 4 Limit Switch 5 OUT 6 Limit Switch 7
M
(seenote-2)
ORANGE BLACK
IN-LIMIT SWITCH OUT-LIMIT SWITCH
NOTE: Withthenewrelayassemblya 12VDCRemoteControlisrequired tobeusedforallvoltages(12or24VDC)
(Remote-Black)
12or24vdc MOTOR
12v DC use 20 amp breaker 24v DC use 15 amp breaker GLENDINNING MARINE PRODUCTS, INC. Conway, SC 843-399-6146
(ifoperating2Cablemasters)
WHITE
UNIT-#2 (Channels3&4)
BATERY POSITIVE(+)
(seenote-1)
OUT OFF IN
RED BLACK
RED WHITE BLACK
(Remote - RED)
(Remote - BLACK) (Rmt - Yellow or Purple)
Black 3 (Rmt - Green or Tan)
(Remote-Tan)
Motor Output
IN 4 Limit Switch 5 OUT 6 Limit Switch 7
(--)
(+)
BATTERY NEGATIVE(-)
Neg. -
White 2
(Remote-Purple)
ORANGE BLACK
M1 M2
IN-LIMIT SWITCH OUT-LIMIT SWITCH
(seenote-2)
12,24v MOTOR
12v DC use 20 amp breaker 24v DC use 15 amp breaker GLENDINNING MARINE PRODUCTS, INC. Conway, SC 843-399-6146
Note: 1.)Connectbatterypositiveleadviafuseorcircuitbreaker. SeeInstallationManualforrating. CircuitBreakerSpecs.: CM7-12Volt20AmpBreaker8-10RunningAmps CM7-24Volt15AmpBreaker5-6RunningAmps 2.)ForlowprofileCablemasterinstallation,themotorleads mustbereversedforcorrectlimitswitchoperation. Seemanualformoreinformation.
04155_remote_wire.eps
IN
Channel #1 Channel #3
REMOTEKEYPAD
REMOTE CONTROL 12VDC
CABLEMASTER RELAY ASSEMBLY # 04034 (12, 24 volt DC) 12/24 Power DC Input Switch Pos. + Red 1
POWER SWITCH
OUT
Channel #2 Channel #4
Version - 2.0
CM-7 CABLEMASTER EXTERNAL WIRING (Old Style)
1
ORANGE BLUE ORANGE OUT POWER BLACK SWITCH IN
DC MOTOR
2 3 4 5 6 7 8 9
WHITE BLUE GREEN RED
IN-LIMIT SWITCH
OUT-LIMIT SWITCH
BATTERY POSITIVE(+) BATTERY NEGATIVE(-)
RED
BLACK ORANGE BLACK
GREEN
WHITE
NOTE: Connect battery positive lead via fuse or circuit breaker. See Installation Manual for rating.
CIRCUIT BREAKER SPECS. : CM7 - 12 VOLT 20 AMP BREAKER 8-10 RUNNING AMPS CM7 - 24 VOLT 10 AMP BREAKER 5-6 RUNNING AMPS CM7 - 32 VOLT 10 AMP BREAKER 5-6 RUNNING AMPS
CM-7 CABLEMASTER EXTERNAL WIRING (New Style)
WHITE RED BLACK
OUT OFF IN
When replacing old style relay with NEW STYLE RELAY, 6 wire power switch connections must be modified. (See Note - 3)
POWER SWITCH
CABLEMASTER RELAY ASSEMBLY # 04034 (12, 24 or 32 volt DC) 12/24/32v Power DC Input Switch Pos. + Red 1
(Remote - RED) (Remote - BLACK) (Rmt - Yellow or Purple) (Rmt - Green or Tan)
OLD POWER 3)SWITCH (see note:
BLUE OUT ORANGE POWER BLACK SWITCH RED IN GREEN WHITE
CUT OFF
(see note -1)
BATERY POSITIVE (+)
RED WHITE BLACK
BATTERY NEGATIVE (-)
Neg. -
White 2 Black 3
Motor Output
IN 4 Limit Switch 5 OUT 6 Limit Switch 7
M
(see note -2)
Note
ORANGE BLACK
M1 M2
IN-LIMIT SWITCH OUT-LIMIT SWITCH
12v DC use 20 amp breaker 24/32v DC use 10 amp breaker GLENDINNING MARINE PRODUCTS, INC. Conway, SC 843-399-6146
12,24 or 32v MOTOR
1.) Connect battery positive lead via fuse or circuit breaker. See Installation Manual for rating. Circuit Breaker Specs.: CM7 - 12 Volt 20 Amp Breaker 8-10 Running Amps CM7 - 24 Volt 10 Amp Breaker 5-6 Running Amps CM7 - 32 Volt 10 Amp Breaker 5-6 Running Amps
04034_Wire.eps
2.) For low profile Cablemaster installation, the motor leads must be reversed for correct limit switch operation. See manual for more information. 3.) To connect 6 wire Power Switch to New Relay Attach: -RED wire to #1 pos. on relay barrier strip. -WHITE wire to #2 pos. on relay barrier strip. -ORANGE wire to #3 pos. on relay barrier strip. Then remove blue, black, and green wires on the Power Switch.