SUBMITTED BY Diksha Sharma 710/10 (100199008842) SUBMITTED TO ER. SUSHIL KUMAR SINGLA
EDUCATIONAL PURPOSES ONLY. IT DOES NOT CONTAIN ALL INFORMATION REQUIRED, AND IS NOT INTENDED TO BE USED FOR THE SPECIFICATION OR DESIGN OF UNINTERRUPTIBLE POWER SUPPLIES (UPS) OR UPS SYSTEMS.
INTRODUCTION
PURPOSE WHAT IS AN UNINTERRUPTIBLE POWER SUPPLY? WHY USE A UPS?
PURPOSE
THE PURPOSE OF THIS PRESENTATION IS TO DISCUSS THE DIFFERENT TYPES OF UNINTERRUPTIBLE POWER SUPPLIES AVAILABLE, WHAT THE UPS PROTECTS AGAINST, THE COMPONENTS OF A UPS, AND ISSUES REGARDING SELECTION AND SIZING. THE DIFFERENT TYPES AND CAUSES OF POWER DISTURBANCES ARE DISCUSSED, AS WELL AS WHAT THE POWER UTILITY, THE ORIGINAL EQUIPMENT MANUFACTURER, AND YOU, CAN DO TO MINIMIZE THEIR EFFECT.
HAS AN ALTERNATE SOURCE OF ENERGY THAT CAN PROVIDE POWER WHEN THE PRIMARY POWER SOURCE IS TEMPORARILY DISABLED
THE SWITCHOVER TIME MUST BE SMALL ENOUGH TO NOT
EQUIPMENT NOT OPERATING PROPERLY COMPUTER AND EQUIPMENT DAMAGE DATA LOSS TIME AND EXPENSE TO RECOVER BACK TO WHERE YOU WERE, IF EVEN POSSIBLE
POWER DISTURBANCES
CAUSES TYPES DURATION RESULTING PROBLEMS COMMENTS WHAT THE POWER UTILITY CAN DO WHAT THE ORIGINAL EQUIPMENT MANUFACTURER (OEM) CAN
TRIPPING BREAKER TREE BRANCHES, ANIMALS, OTHER UTILITY FAULT CLEARING CONSTRUCTION ACTIVITY ACCIDENTS MOTOR VEHICLE, OTHER EQUIPMENT FAILURE OVERLOADING LOAD SWITCHING NON-LINEAR LOADS POOR GROUNDING ESD
INTERRUPTION SAG, UNDER VOLTAGE SURGE, OVER VOLTAGE VOLTAGE FLUCTUATION FREQUENCY VARIATION SPIKES / TRANSIENTS
WAVEFORM DISTORTION
VOLTAGE IMBALANCE
10
CYCLE (8 1/3 ms) OR LESS CYCLE TO 3 SEC 3 SEC TO 1 MIN GREATER THAN 1 MINUTE
11
DISSIPATIVE
EQUIPMENT EXPERIENCES REPEATED STRESSES THAT LEAD TO FAILURE LATER FOR NO APPARENT REASON
DESTRUCTIVE
12
DATA ERRORS DATA LOSS BLOWN FUSES TRIPPED BREAKERS INTERFERENCE WITH CONTROL OF LOADS OVERLOADED NEUTRAL CONDUCTORS MOTORS
HEATING SPEED VARIATION STALLING AUDIBLE NOISE VIBRATION HEATING AUDIBLE NOISE VIBRATION
TRANSFORMERS
13
INDUSTRIAL EQUIPMENT TO SMALL, SENSITIVE ELECTRONIC COMPONENTS, ARE CONNECTED TO THE SAME POWER GRID
14
WHAT THE POWER UTILITY CAN DO TO MINIMIZE THE EFFECT OF POWER DISTURBANCES
INSTALL STORM RESISTANT WIRING USE INFRA RED SCANNING TO DETECT WEAK SPOTS IN POWER
LINES INSTALL REMOTE CONTROLLED RADIO SWITCHES TO RESTORE POWER QUICKLY CLEAR TREE LIMBS AWAY FROM POWER LINES
15
SURGE PROTECTIVE DEVICES LINE FILTERS ISOLATION TRANSFORMER BATTERY OR CAPACITOR BACK UP TO INCREASE RIDE THROUGH TIME
16
FOR EXAMPLE, BATTERY BACK UP FOR ANY APPLIANCE THAT CONTAINS A CLOCK
SURGE PROTECTORS LINE FILTERS ISOLATION TRANSFORMER VOLTAGE REGULATING LINE CONDITIONER UPS
17
LINE FILTERS
FILTERS OUT HARMONICS, TRANSIENTS AND NOISE
ISOLATION TRANSFORMER
ELIMINATES DC OFFSET AND NOISE
18
INTERRUPTION SAG, UNDER VOLTAGE SURGE, OVER VOLTAGE VOLTAGE FLUCTUATION FREQUENCY VARIATION SPIKES / TRANSIENTS
WAVEFORM DISTORTION
YES
VOLTAGE IMBALANCE
YES YES YES YES YES YES YES YES YES YES YES YES YES
19
UPS
ARCHITECTURES WAVEFORMS INVERTER TECHNOLOGY COMPONENTS SWITCHOVER TIME ADVANTAGES / DIS-ADVANTAGES SIZING BATTERY SAFETY
20
UPS ARCHITECTURES
LINE INTERACTIVE ON-LINE
21
BATTERY
AC FAIL
22
BATTERY
INVERTER FAIL
23
BATTERY
24
UPS WAVEFORMS
TRUE SINEWAVE MODIFIED SINEWAVE SQUARE WAVE
25
UPS WAVEFORMS
170
VOLTAGE
0 0 4 8 12 16 20
TIME (ms)
-170
26
27
TRANSISTOR BRIDGE
TRANSFORMER
FILTER
28
DC POWER
SINEWAVE OSCILLATOR
COMPARISON AMPLIFIER
POWER AMPLIFIER
29
SWITCH DRIVE
TRANSISTOR SWITCHES
TRANSFORMER
30
UPS COMPONENTS
CONVERTER - AC TO DC
SPD - PROTECTS AGAINST SPIKES AND TRANSIENTS STORED ENERGY DEVICE - PROTECTS AGAINST INTERRUPTIONS
BATTERY
INVERTER DC TO AC
WAVEFORM SYNTHESIS PROTECTS AGAINST DC OFFSET AND INTERHARMONICS FILTER PROTECTS AGAINST HARMONICS, NOTCHING AND NOISE VOLTAGE REGULATOR PROTECTS AGAINST SAGS, SURGES AND FLUCTUATIONS
31
SWITCHOVER TIME
A TYPICAL SWITCHOVER TIME
ONE QUARTER CYCLE OR LESS FOR SOME EQUIPMENT THIS IS NOT TOLERABLE
2 4 ms
32
AC TO DC CONVERTER / BATTERY CHARGER DOES NOT HAVE TO PROVIDE FULL LOAD POWER (POTENTIALLY CHEAPER) LESS STRESS ON DC TO AC INVERTER SINCE IT RUNS AT NO LOAD UNTIL UPS SWITCHES TO BATTERY POWER (POTENTIALLY CHEAPER)
ON-LINE ADVANTAGES
ZERO SWITCHOVER TIME FROM MAIN LINE TO BATTERY POWER ALWAYS ISOLATED FROM POWER DISTURBANCES ON THE MAIN LINE
33
OBTAIN RATINGS FROM NAMEPLATE OR SPEC SHEET ENERGY USAGE MAY BE SPECIFIED IN VOLT AMPS (VA) OR WATTS (W) AND IN VALUES THAT ARE EITHER MAXIMUM OR NOMINAL (VA) AND (W) ARE RELATED VIA THE POWER FACTOR
TOTAL UPS LOAD MUST NOT EXCEED THE UPS VOLT AMP (VA)
RATING
TOTAL UPS LOAD MUST NOT EXCEED THE UPS WATT (W)
RATING
OVERSIZE / DERATE TO ADD LIFE RUNTIME CHARTS
34
35
BATTERY SAFETY
MAINTENANCE
RISKS
ACID ELECTRIC SHOCK BURN FLYING, MOLTEN METAL (EYES) INJURIES RESULTING FROM CARRYING HEAVY BATTERY PACKS
DISPOSAL
36
GENERAL DISCUSSION
DOES A UPS OFFER COMPLETE PROTECTION? DO YOU THINK POWER DISTURBANCES WONT HAPPEN TO
YOU ? MISCELLANEOUS
37
38
OF A UPS
39
MISCELLANEOUS
MANY RETAIL UPS FOR COMPUTER APPLICATIONS ARE LINE
INTERACTIVE
MANUFACTURERS AND BUILDING CODES DO NOT ALLOW
40
ARCHITECTURE - LINE INTERACTIVE OR ON-LINE WAVEFORM - SQUARE, MODIFIED SINE, TRUE SINE IMMUNITY TO DISTURBANCES OTHER THAN OUTAGE
RELIABILITY
AUDIBLE NOISE MONITOR AND CONTROL HARDWARE / SOFTWARE
41
REFERENCES
IEEE STANDARD 1100-2005
RECOMMENDED PRACTICE FOR POWERING AND GROUNDING SENSITIVE ELECTRONIC EQUIPMENT
42