You are on page 1of 75

2008-05

Security Level: Internal Use

HUAWEI BSC6000 V900R008 Hardware Structure & System

Description
(TC&BM Combination)
www.huawei.com

ISSUE 1.0
Wireless Case and Training

HUAWEI Confidential

The course introduce BSC6000V900R008 function and features firstly, then mainly explain the hardware structure and system principle of BSC6000V900R008 in TC/BM combination model, at last commend some configuration types of TC/BM combination model.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 2

In the end of training about BSC6000V900R008, you should know or master some points as following:

BSC6000V900R008 function and features


Hardware structure and system principle of TC/BM combination model Typical configuration of TC/BM in BSC6000 combination model

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 3

HUAWEI BSC6000 Product Introduction HUAWEI BSC6000 Hardware Description

HUAWEI BSC6000 Features Description

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 4

Chapter 1 BSC6000V900R008 System Description Chapter 2 BSC6000V900R008 Hardware Structure Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 5

BSC6000 Roadmap
V9R8C01 V9R3C01 Abroad V9R1C04 Nation

V9R1C01

V9R1C03

2007.02 R1

2007.06

2007.09

2007.12 R8

R3

V9R1C01 is the first business version of BSC6000 V9R1C03 enhances the BSC performance, support power reduction

Support GOMU MML Command Optical Port Backup Location Switching Flex Abis

Inner PCU GBSS IP Solution Abis Over HDLC TC/BM Subrack Combined

Support Separate BTS Support QTRU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 6

BSC6000V9R8 Specification Description


V9R8 Specification Items TRX Number (FR) TRX Number (HR) V9R1 V9R3 BM/TC Separate 2048 2048 2048 1024 2048 2048 24 2 4 BM/TC Combine 2048/1792 2048/1792 1 15360 14 NA 576/352 18/11 448 8 128 A Interface Over IP 2048 2048 1 15360 1 4 NA 576 18 NA NA 224

Full Configuration Cabinet Number 34 A Interface Circuits GxPS Subrack Number GTCS Subrack Number Abis Interface E1Number Abis Interface STM-1Number A Interface E1Number A Interface STM-1Number Pb Interface E1 Number

15360 15360 15360 14 14 640 20 512 8 224 14 14 576 18 512 8 224 1 4 1 4 576 18 512 8 224

Pb Interface STM-1Number
Gb Interface Throughput

7
NA

7
NA

256Mbps/512Mbps 256Mbps/512Mbps 256Mbps/512Mbps

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 7

Function and Features


Configuration A is outer GBAM, configuration B is inner GOMU. Support inner PCU (please consult HUAWEI BSC6000 Inner PCU Instruction ), Outer PCU will be supported continuously.

Support A interface over IP (please consult HUAWEI BSC6000 A interface


over IP subject) Support Abis interface over HDLC (please consult HUAWEI BSC6000 Abis interface over HDLC subject )

Support Abis interface over HDLC or over IP

Support Hub BTS of HDLC as transmit mode (please consult HUAWEI BSC6000 Abis interface over HDLC subject ) Support TC/BM combination and separation configuration mode Suport Um interface soft synchronization

Support distributed Base Station DBS3036


Support QTRU Support dynamic transmit diversity (PBT)
HUAWEI Confidential
Page 8

HUAWEI TECHNOLOGIES Co., Ltd.

High Integration, Single Rack 2048TRX

+
V900R001/V900R003

=
PCU6000

BSC6000V900R008

4Rack Supports 2048TRX 4 Racks at most 4BM+4TC at most

Outer PCU

Single Rack Support 2048TRX Inner PCU

BSC6000V900R008 supports 2048TRX in single Rack and also PCU integrated


innerly at same Rackreduce the area located and solve the problem of space lack. For the reason of high integration, Power will be mostly reduced, TC/BM combined configuration power is 2325WA Interface is OpticalAbis Interface is E1 /3340W (A and Abis Interface are E1).
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 9

Configuration Flexible, Support BM/TC Separated and Combined Configuration


BM/TC Separated BM/TC Combined

+
GMPS/GEPS

=
GTCS

GMPS/GEPS

Need to add the Ater Interface board

BM/TC separated mode, TC support DPUa and DPUc mixed inserting

GDPUX must use DPUc as physical board and no need to add Ater interface board

When BSC and MSC are located in the same equipment room, combined BM/TC is recommended, i.e., GTCS is not needed, so the configuration is more flexible. When BSC and MSC are in different equipment rooms, separated BM/TC with remote TC will be used.
HUAWEI Confidential
Page 10

HUAWEI TECHNOLOGIES Co., Ltd.

Capacity Index
Capacity Name Maximum of supporting BTS Maximum of supporting Cell Maximum of supporting TRX Index 2048 2048 2048

BHCA
Maximum of supporting Traffic Volume Maximum of supporting User Maximum of configuring PDCH TBF number of single PDCH Number of 16K timeslot in Abis EDGE RTT index Gb interface throughput

3500000
13000Erl 650000 1024 uplink7 downlink8 61440 200 ms 512Mbps

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 11

Hardware Index

BSC6000 Physical Structure


Index Name Rack standard Rack dimension Available height Rack weight Bear weight of floor Index Value design complies with the IEC60297 and IEEE standards. 2200mmHigh*600mmWidth*800mmheight 46U Empty rack 150kgFull rack 350kg 450kg/m2

BSC6000 Power Index( BM/TC Combination)


Typical configuration 512TRX 1024TRX 1536TRX 2048TRX Power( Ater is optical, Abis is E1 Power (A interface is E1, Abis interface is E1, TC&BM combination) 890 1 510 1 950 2325 1 325 2 320 3 250 3 340

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 12

Chapter 1 BSC6000V900R008 System Description Chapter 2 BSC6000V900R008 Hardware Structure

Chapter 3 BSC6000V900R008 System Signal Flow


Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 13

Abbreviation
Abbreviation

of Cabinet and Subrack


English Full Name GSM BSC Control Processing Rack GSM BSC Service Processing Rack GSM Integrated Management System GSM Back Administration Module GSM Main Processing Subrack GSM Extended Processing Subrack

English Abbreviation GBCR GBSR GIMS GBAM GMPS GEPS

GTCS

GSM TransCoder Subrack

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 14

Structure of Rack

Model: The BSC6000 uses HUAWEI N68-22 rack. The rack design complies with the IEC60297 and IEEE standards.

Structure

Dimension: 600mm (width) x800mm (depth) x 2200mm (height) Weight: Empty rack 150kg; full configuration 350kg

Type
The BSC6000 rack is categorized into two types:

GBCR: GSM BSC Control Processing Rack GBSR: GSM BSC Service Processing Rack

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 15

Rack GBCR

GBCR: It must be configured with main


processing subrack and GBAM server. It processes the BSC6000 services and performs operations and maintenance.

Power Distribution Box

Cabling Subrack

Subrack

Configuration A, GBCR configuration


GIMS 2Subracks(

contain 1GMPS) at most

Subrack

Air Defense Subrack

Configuration B, GBCR configuration


1GMPS+

2GEPS(at most) KVM

Dummy Panel

GIMS: contains

One KVM (keyboard, video and mouse) One LAN Switch One GBAM (GSM Back Administration Module) server
On the condition of configuration BGIMS is configured at GMPS subrack
HUAWEI Confidential

Lan Switch

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

Page 16

Rack GBSR

GBSR: It is only configured with subracks. It performs service processing functions of the BSC6000.

Power distribution box

One service rack can be configured with three subracks.

According to the requirement of service quantity,


each BSC6000 system contains a maximum of three service racks.

Air defence subrack subrack

Air defence subrack

Dummy panel
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 17

Subrack

Subrack: The subrack complies with

the IEC60297 standard. The width of it


is 19 inches. A backplane is in the middle of the subrack, and boards are inserted from the front and the rear of the subrack. Both the front subrack and the rear subrack provide 14 slots. The slots are numbered 0027 from the front to the rear.

Air Defense Box Board

Cabling subrack

Front

Rear

The BSC6000 contains three

subracks:

GMPS main processing subrack GEPS extension processing subrack GTCS voice processing subrack

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 18

Dip switch of Subracks


The DIP switches on the BSC subrack are used to define the numbering of the BSC subrack. The DIP bits are numbered in ascending order from bit 1 to bit 8. ON represents digit 0 and OFF represents digit 1. As the DIP switches use odd parity check, the number of 1s in the eight DIP bits must be an odd number. Set the DIP switch as follows: Set bits 15 and 8 first. Set bit 7 to 0. Check the number of 1s in the bits of the DIP switch. If the number of 1s is even, set bit 6 to 1. If the number of 1s is odd, set bit 6 to 0.

Bit 1 2 3 4 5 6 7 Meaning Subrack number control bit Subrack number control bit Subrack number control bit Subrack number control bit Subrack number control bit Odd parity check bit It is undefined, and is generally set as 0. The automatic DIP bit of the GSCU board in the central subrack is: 0, the starting of boards is highly dependent on the GBAM server, namely that the boards load from the server after starting. 1, the starting of boards is less dependent on the GBAM server, namely that the boards check the validity of the Flash file when starting, and load from the Flash file if the Flash file is valid or load from the server if the Flash file is invalid.

ON

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 19

Hardware Configuration Type A

BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)


E1/T1 are the interface transport model: 1 GIMS1 GMPS3 GEPS STM-1 is used in A interface :1 GIMS1 GMPS2 GEPS
E1/T1 as transport model A interface is optical

GBCR

GBSR

GBCR

GBSR

GEPS

GEPS

GMPS

GEPS

GMPS

GIMS

GEPS

GIMS

GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 20

Hardware Configuration Type A

BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)


E1/T1 are the transport model : 1 GMPS3 GEPS STM-1 is used in A interface: 1 GMPS2 GEPS
E1/T1 as transport model A interface is optical GBCR

GBCR

GBSR

GEPS

GEPS

GEPS

GEPS

GMPS

GEPS

GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 21

System Logical Structure

The BSC6000 system consists of the following logical functional subsystems:


TDM Switching Subsystem GE Switching Subsystem Service Processing Subsystem

Service Control Subsystem

Interface and Signaling Processing Subsystem


Clock Subsystem

TDM switching subsystem

Service processing subsystem

Service control subsystem

Interface and signaling processing subsystem

E1/STM-1 to BTS E1/STM-1 to PCU E1/STM-1 to MSC Clock subsystem

GE switching subsystem

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 22

TDM Switching Subsystem

Intra-Subrack: Other boards in the subrack connect with GTNU

(Active/Standby) through Rear LVDS (Low Voltage Differential Signal) high


speed serial ports;

Inter-Subrack: TDM units of every subrack interconnected fully with each other through GTNU interconnection cable;
Board
GTNU Active GTNU Standby

GTNUActive

Board

Board

GTNU Standby

Board

LVDS of Rear GTNU Interconnection Cable


HUAWEI TECHNOLOGIES Co., Ltd.

Full Interconnection intrasubrack, 2 cable support 8K band width.

HUAWEI Confidential

Page 23

Board GTNU
GTNU

The GTNU is the TDM switching unit in the BSC6000. The active GTNU and the standby GTNU are inserted in slots 4 and slot 5 of the GMPS/GEPS/GTCS. The GTNU board performs the TDM switching function, which is the TDM switching center of the system.

RUN ALM ACT

TNM1

TNM0

The GTNU has the following functions:


TNM2

Providing 128 K 128 K TDM switching Allocating TDM network resources, establishing, and releasing radio links

TNM4

TNM3

TNM5

Port TDM05

Function TDM high-speed serial port, used to connect the GTNUs between subracks

Matching connector DB14

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 24

Inter-Subrack Interconnections of GTNU Crossover Cables


Pin14 A W1 Pin1 A X2 X1 W2 W4 X4 W3 X3 Pin14 B 1 2 3 Pin1 B

0
GTNU GTNU

3
GTNU GTNU

1
GTNU GTNU

2
GTNU GTNU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 25

GE Switching Subsystem

Intra-subrack active/standby GSCU boards: HiG interconnection; 30G bandwidth Intra-subrack GE switching: The GSCU board provides 48G GE switching capability. Inter-subrack GE switching: The GSCU board provides 12 GE ports to realize star interconnection through intercross cable.
Board 1
GSCU (Active) GSCU (Standby) GSCU (Active) GSCU (Standby) Board 1

Board 26

Board 26

GE of Rear Intercross Cable

Star interconnection between subracks, four cable realize Active/Standby model


HUAWEI Confidential
Page 26

HUAWEI TECHNOLOGIES Co., Ltd.

BoardGSCU

SCUa

RUN ALM ACT RESET


LINK ACT

0 1 2 3
LINK ACT

The GSCU is the switching control unit in the BSC6000. The active and standby GSCU are inserted in slots 6 and 7 of the GMPS/GEPS/GTCS. The GSCU board provides maintenance management of the subrack and GE switching platform for the subrack. The GSCU has the following functions:

4 5

6 7
LINK ACT

Performing maintenance management of the subrack Providing a GE platform for the subrack Providing clock information for the other boards in the same subrack except the GGCU
Function 10M/100M/1000M Ethernet ports, used to connect subracks 10M/100M/1000M Ethernet ports, used to connect GBAM (Only the main subrack is connected with the GBAM) Debugging port Clock source port, used to receive the 8 kHz clock signals from the panel of the GGCU Clock test signal port, used to output clock test signals SMB RJ45 RJ45 Matching RJ45 RJ45

8 9 10 11

10/100/1000BASE-T

Port EHT09 EHT1011 COM CLKIN

TESTOUT

PARC

CLKIN

COM

TESTOUT

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 27

GE Switching Interconnection
GSCU in GMPS
GE 0

GSCU in GMPS

GE TRUNK1
GE 1

GE0/1 : Idle GE27 interconnect with GEPS GE10/11 interconnect with GBAM

GE TRUNK2

GE 2 GE 3

GE 0 GE 1

1GEPS

GE 0
GE 1

GSCU in GEPS

GE 4

GE TRUNK3
GE 5

2GEPS

GE0/1 interconnect with GEPS

GE TRUNK4

GE 6 GE 7

GE 0 GE 1

3GEPS

GE 8

GE TRUNK4
GE 9

GE TRUNK5

GE 10

GBAM

LMT

GE TRUNK6 CPU FE

GE 11

M2000
FE

LanSwitch
HUAWEI Confidential
Page 28

HUAWEI TECHNOLOGIES Co., Ltd.

Interconnection Between Subrack


A interface

GEPS
Abis interface
MSC

Gb/Pb interface

GEPS

MS

BTS

SGSN

GMPS

Subracks in BSC6000 compose an interconnection switching network through cascade.


GSCU Star interconnection GTNU Full interconnection

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 29

Service Processing Subsystem

Hardware entity of service processing subsystem are DPUc/DPUd boards:


DPUa couldnt be used in V900R008 combination model; DPUc is configured as DPUX on combination model; DPUd board processes inner PCU packet service and is configured as GDPUP; acd physical version.
GMPS GEPS
22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B 14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G O I U A G O I U A 20 21 G E I U B G E I U B 22 23 G E I U B G E I U B 24 25 26 27 G E I U B G E I U B G D P U X G D P U X G O M U

Note: DPUData Processing Unitis digital signal processing unit for PARC platform,

14 15 16
G O I U A G O I U A G O I U A

17 18 19 G O I U A G E P U G G E P U G

20 21

Rear

Rear

Backplane
G X Front P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G D P U P G D P U P G D P U X G D P U X G G C U G G C U

Backplane
G X Front P U M
G G G D D T P P N U U U P X 00 01 02 03 04 05 06 07 08 09 10 11

G X P U M

G X P U T

G X P U T

G T N U

G S C U

G S C U

G D P U P

G D P U P

G D P U X

G D P U X

00 01 02 03 04 05 06 07 08 09 10 11 12 13

12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 30

BoardGDPUX
DPUa

RUN ALM ACT

The GDPUX processes CS services and packet services. GDPUX is configured in 08~11 of GMPS/GEPS or 13~27 of GEPS, The board performs the voice and data service processing functions. It works in subrack resource pool mode. The GDPUC performs the following functions:

Encodes and decodes voice signals

Provides data service rate adaptation


Provides Tandem Free Operation (TFO) functions When the calling and called MSs use one voice coding scheme, the voice signals are encoded only once at the originating MS and decoded only once at the terminating MS. This reduces repeated

encoding and decoding and improves the quality of speech services.

PARC

Provides voice enhancement function Detects voice faults automatically


HUAWEI Confidential
Page 31

HUAWEI TECHNOLOGIES Co., Ltd.

BoardGDPUP
DPUa RUN ALM ACT

The GDPUP is the GSM Data Processing Unit for PS services. It can be installed in slots 811 in the GMPS/GEPS or in slots 13-27 in the GEPSit processes the packet services for the BSC. GDPUP is configured when PCU is inner GDPUP perform the following function:

Processes the packet services on up to 1,024 simultaneously active PDCHs where signals are coded in MCS9 Processes packet links Detects voice faults automatically

GDPUP works as system resource pool

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 32

Service Control Subsystem

The BSC service control subsystem performs the following functions: paging control, message management, channel assignment, BTS public service management, call control, packet service control, handover and power control, cell broadcast short message service, and TC resource pool management. This describes the components of the BSC service

control subsystem.

The components of the BSC service control subsystem are as follows:


GXPUM configured in the GMPS

GXPUT configured in each subrack


GBAM/GOMU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 33

BoardGXPUM /GXPUT
GXPU

GXPUM /GXPUT

RUN ALM ACT

GXPUM is main service processing board and and is configured as 01 slots in GMPS/GEPS; GXPUT is transmitting processing unit and is configured as 23 slots in GMPS/GEPS; GXPUM/GXPUT have four built-in CPUs and processes the key services of the BSC

LINK ACT

When the single subrack TRX number is less than 256, GXPUT isnt necessary.

0 1 2 3

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

10/100/1000BASE-T

HUAWEI Confidential

Page 34

BoardGXPUM /GXPUT

CPUs of XPU board are distributed as CPU0,CPUX,CPUP


Name CPUs CPU0 CPU3 CPU1 CPU2 CPU0 CPU1 CPU2 CPU Types CPU0 CPUP Function Algorithm, Resource Management, PS Signal Processing Inner PCU Maintenance, Cell Broadcast

GXPUM

CPUX

CS Service and signal processing

GXPUT

CPU3 GMPS
14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G E P U G G E P U G 20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B 14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G O I U A G O I U A

GEPS
20 21 G E I U B G E I U B 22 23 G E I U B G E I U B 24 25 26 27 G E I U B G E I U B G D P U X G D P U X

Rear

Rear

Backplane
G X Front P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G D P U P G D P U P G D P U X G D P U X G G C U G G C U

Backplane
G X Front P U M
G G G D D T P P N U U U P X 00 01 02 03 04 05 06 07 08 09 10 11 G T N U G S C U G S C U

G X P U M

G X P U T

G X P U T

G D P U P

G D P U P

G D P U X

G D P U X

00 01 02 03 04 05 06 07 08 09 10 11 12 13

12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 35

GBAM and GOMU Board

GBAM and GOMU finish the following function in BSC:

Provides configuration management, performance management, fault management, security management, and loading management for the BSC; As the OM center of the BSC, the GOMU enables the communication between the LMT and the other boards in the BSC. The GOMU features high computation speed and outstanding data processing capability. Interfaces with the LMT/M2000 on behalf of the BSC
Suggest to be empty for future upgrade GMPS
14 G O I U A G X P U M 00 15 G O I U A G X P U M 01 16 17 18 G G G O O E I I P U U U A A G G X P U T 02 G X P U T 03 19 20 21 22 23 G G G E O O P M M U U U G 24 25 26 G G G E E E I I I U U U B B B G D P U X 11 27 G E I U B 14 G O I U A G X P U M 00 15 G O I U A G X P U M 01 16 17 18 G G G O O E I I P U U U A A G G X P U T 02 G X P U T 03

GMPS
19 20 21 22 23 G E P U G 24 25 26 G G G E E E I I I U U U B B B G D P U X 11 27 G E I U B

Rear

Rear

Backplane

Backplane
G G D D P P U U P X 09 10 G G C U G G C U G G D T P N U U P 04 05 06 07 08 G T N U G S C U G S C U G G D D P P U U P X 09 10 G G C U G G C U

Front

G G D T P N U U P 04 05 06 07 08 G T N U G S C U G S C U

Front

12 13

12 13

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 36

BoardGOMU

As the OM center of the BSC, The GOMUs are installed in slots 2023 in the GMPS and work in active/standby mode. The GOMU features high computation speed and outstanding data

processing capability . The GOMU has the following functions:

Provides configuration management, performance management, fault management, security management, and loading management for the BSC Interfaces to the LMT/M2000 on behalf of the BSC
(1) Screw (4) RUN LED (7) Reset button (10) ETH0 (Ethernet port) (13) COM port (16) OFFLINE LED (2) Leaf spring (5) ALM LED (8) Shutdown button (11) ETH1 (Ethernet port) (14) VGA port (17) Hard disk (3) Wrench (6) ACT LED (9) USB port (12) ETH2 (Ethernet port) (15) HD LED (18) Screw for fix the hard disk

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 37

BoardGBAM Interface

Power Button

CD Rom 10M/100M RJ45 NIC Automatic Adaptation Port

LCD Interface

KVM Interface

RJ45 RJ45 NIC NIC Interface


HUAWEI TECHNOLOGIES Co., Ltd.

RJ45

End
Page 38

DC Prot

HUAWEI Confidential

Interface Processing Subsystem

Interface processing subsystem provide interfaces between BSC/BTS/NSS, finish data link layer signal processing function as following:

Support A/Abis/Pb/Gb interface Support processing of cell broadcast service

Support No.7 signal MTP processing CBC Cb

Abis

BTS

GMPS/GEPS BSC6000
Pb Gb

MSC

PCU

Inner or Outer PCU

SGSN

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 39

Interface Board
Physical Board A

EIUa GEIUA GEIUB GEIUP \

OIUa GOIUA

PEUa \ GEHUB \ GEPUG

FG2a GFGUA

GOUa GOGUA GOGUB \ \

Abis Pb Gb

GOIUB
GOIUP \

GFGUB
\ GFGUG

RINT EIUa OIUa PEUa FG2a GOUa 32 E1/T1 Interface 1 TDM over STM-1 32 Packet over E1/T1 Interface 8 Packet over FE or 2 Packet over GE Electrical Interface 2 Packet over GE Optical Port

Interface A/Abis/Pb A/Abis/Pb Abis/Gb A/Abis/Gb A/Gb

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 40

BoardEIUa/OIUa

GEIU GOIU

Interface boards GEIU / GOIU contain:


GEIUB/GOIUB for Abis Electrical Unit/ Optical Unit GEIUP/GOIUP for Pb Electrical Unit/ Optical Unit GEIUA/GOIUA for A Electrical Unit/ Optical Unit EIUa provides 32E1 ports OIUa provides 1STM-1 interface, bear 63E1 Provides Tributary Protection Switching (TPS) between the active and standby boards

RUN ALM ACT

RUN ALM ACT

E1/T1(24~31)

RX TX

Main function contain


E1/T1(16~23)

LOS

E1/T1(8~15)

Interface
E1/T1(0~7)

Function

Matching connector

E1/T1(031)
2M0 TESTOUT 2M1

E1/T1 port, used to transmit and receive E1/T1 signals


on routes 07 2.048 MHz clock source output port, used to output the extracted line clock as the system clock source 2.048 MHz clock output port, used to output the testing clock of the system

DB44

2M0

TESTOUT 2M1

2M01

SMB male connector SMB male connector

PARC

PARC

TESTOUT
1 2

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 41

BoardFG2a

Main function:

8 10M/100M FE ports, thereinto 2 GE ports(0,4); Provides IP routing Provides the routing-based backup and load sharing Provides Tributary Protection Switching (TPS) between the active and standby boards

Physical Name

Logical Name GFGUA

Value 6144 voice circuit 384TRX, 100%(HR) 128M bps Gb throughput Function

FG2a

GFGUB GFGUG

Interface ID 10/100M 10/100/1000M 2M0 2M1 HUAWEI TECHNOLOGIES Co., Ltd.

Type RJ45 RJ45

The 10M/100M ports are used to transmit 10/100 Mbit/s signals The 10M/100M/1000M ports are used to transmit 10/100/1000 Mbit/s signals. No use No use
Page 42

HUAWEI Confidential

BoardGOUa

Main function:

Provides two GE optical ports Provides IP routing Provides the routing-based backup and load sharing Provides Tributary Protection Switching (TPS) between the active and standby boards
Physical Name GOUa GOGUB Interface ID RX TX 2M0 2M1 LC/PC Type 384TRX, 100%(HR) Function Logical Name GOGUA 6144 voice circuit Value

Optical ports, used to receive and transmit optical signals. TX indicates the transmitting optical port and RX indicates the receiving optical port.
No use No use

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 43

BoardPEUa

Main function

Provides 32 E1/T1 ports Provides Tributary Protection Switching (TPS) between the active and standby boards

Physical Name PEUa

Logical Name GEHUB GEPUG

Value 384TRX, 100%(HR) 64M bps Gb throughput

Interface ID E1/T1(0~31) 2M0 2M1

Type DB44 SMB Male Connector SMB Male Connector

Function 031 E1/T1 for transmitting signal No use No use

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 44

Clock System
Synchronization Clock GGCU (Active/Standby) 0# subrack Transmit Clock

Backplane

Cable Transmit

GSCU
Backplane

GSCU
Backplane

GSCU
Backplane

Board

Board

Board

Board

Board

Board

GMPS HUAWEI TECHNOLOGIES Co., Ltd.

GEPS HUAWEI Confidential


Page 45

GEPS

BoardGGCU

GGCU

RUN ALM ACT


ATN-IN 0 1 2 3 CLKOUT

The GGCU is the general clock unit in the BSC6000. The active GGCU and the standby GGCU are configured in slots 12 and 13 in the GMPS. The GGCU board provides synchronous timing signals for the system The GGCU has the following functions:

Generating and keeping synchronous clock signals Keeping the consistency of synchronization information output from the active and standby GGCUs
Port
CLKOUT09

4 5 6 7

Function
Synchronization signal output port, used to output 8 kHz clock signals to the GSCU

Matching Connector RJ45

8 9 COM0 COM1
CLKLIN0 TESTOUT

COM01 TESTOUT TESTIN CLKIN01

Standby Standby Standby Synchronization clock signal input port, used to input one route of external 2.048 MHz signal and 2.048 Mbit/s code stream signals

RJ45 SMB male connector SMB male connector SMB male connector

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

CLKLIN1

TESTIN

HUAWEI Confidential

Page 46

Clock Subsystem
GGCU Reference Clock Input
To input the active-standby clock of the GGCU, you can use the signals provided by the

BITS and the 2.048MHz clock signal extracted from the upper-level clock by the
interface panel in the service subrack. The GGCU backplane uses the interface panel of the same subrack to extract the 8 KHz clock signals from the upper-level clocks.

Reference Clock for the GMPS or GEPS


The reference clocks are provided by the GGCU. The reference clocks generate 8kHz clock signals through the GGCU. GMPS: The clock signals are sent to the GSCU in the GMPS subrack through the backplane. Then, the clock signals are sent to other boards in the same subrack.

GEPS: The clock signals are sent to the GSCU board in the GEPS subrack through the
clock cable. Then, the signals are sent to other boards through the backplane.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 47

Clock Synchronization Interconnection


The connection of the GGCU of the main subrack and the GSCU of the extension subrack is shown as following figure:

The active GGCU and the standby GGCU output 10-way signal channel respectively. A signal channel of an active GGCU and that of a standby GGCU are integrated through the Y-shaped cable.

GGCU support six service subracks, one is the GMPS, others five are the GEPSs where the 10 cables from GSCUs to GGCU can be connected at most. Any of component including GGCU, Y-shaped cable, and GSCU is faulty, the system clock still can work normally. GMPS
GGCU GGCU

GEPS
GSCU GSCU

Y Cable

HUAWEI TECHNOLOGIES Co., Ltd.

GEPS
GSCU GSCU

HUAWEI Confidential

Page 48

Clock Cable

1 W2

1
8 1

8 1

X2 W1 X1 W3 X3
8 1

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 49

Chapter 1 BSC6000V900R008 System Description Chapter 2 BSC6000V900R008 Hardware Structure Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 50

Voice Service Signal Flow

Abis over TDM+A over TDM


A Board is GEIUA/GOIUA

MS

BTS

G E I U B

G T N U

Abis

G D P U X

G E I U A

MSC A

GMPS/GEPS

Abis Board is GEIUB/GOIUB

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 51

Voice Service Signal flow

Abis Over HDLC/IP+A Over TDM


A interface board is GEIUA/GOIUA

MS

BTS

G E H U B

G S C U

Abis

G D P U X
GMPS/GEPS

G T N U

G E I U A

MSC A

When Abis is Over IP, interface board is GFGUB/GOGUB Front Board Rear Board E1/T1 cable

Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 52

Packet Service Signal Flow (Outer PCU)

Abis Over TDM

When Abis interface is over HDLC/IP, BSC6000 doesnt support outer PCU

MS

BTS

G E I U B

G T N U
GMPS/GEPS

G E I U P
Pb

PCU Gb

SGSN

Abis

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 53

Packet Service Signal Flow (Inner PCU)

Abis Over TDM


G E I U B

Gb Board is GFGUG/GEPUG

MS

BTS

G T N U

G D P U P
GMPS/GEPS

G S C U

G E P U G
Gb

SGSN

Abis

Abis Over HDLC/IP


G E H U B

When Abis is Over IP, board is GFGUB/GOGUB

MS

BTS

G S C U

G D P U P
GMPS/GEPS

G S C U

G E P U G
Gb

SGSN

Abis

Front Board Rear Board


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 54

E1/T1 cable Backplane TDM Switching Backplane GE Switching

Abis Interface Signal

Abis interface board should be configured by the requirement as following:


Abis over TDM: GEIUB/GOIUB


Abis over HDLC: GEHUB Abis over IP: GFGUB

Signal processing flow:

GXPUT/GXPUM process LAPD and RR protocol

GXPUM process BTSM protocol


G X P U T
GMPS/GEPS

MS

BTS
Abis

G S C U

G S C U

G X P U M

Abis Board

Front Board Rear Board


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 55

E1/T1 cable Backplane TDM Switching Backplane GE Switching

No.7 Signal Flow

Through the processing of MTP2 model, it will be transmitted to GXPUM as intra-signal;

G X P U M

G S C U
GMPS/GEPS

G E I U A

MSC

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 56

Pb Signal Flow (Outer PCU)

The BSC internal signaling flow from the Pb interface is as follows:

The signaling is transmitted to the GXPUT/GXPUM in the GMPS/GEPS over the Pb interface. The GXPUT processes the signaling according to the LAPD protocol. Upon reception of the signaling from the GSCU, the GXPUM processes the

signaling according to the PbIP and RR protocols.


Through the processing of LAPD model, it will be transmitted to GXPUM as intra-signal;

G X P U M

G S C U
GMPS/GEPS

G E I U P
Pb

PCU Gb

SGSN

Front Board Rear Board


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 57

E1/T1 cable Backplane TDM Switching Backplane GE Switching

Gb Signal Flow (Inner PCU)

The BSC internal signaling flow from the Gb interface is as follows:

The signaling is transmitted to the GMPS/GEPS over the Gb interface. If the sub NS layer of the NS protocol complies with the FR protocol, the Gb interface board is the GEPUG. If the sub NS layer of the NS protocol complies with the IP protocol,

the Gb interface board is the GFGUG.


The GSCU transmits the signaling to the GXPUM. The GXPUM processes the signaling according to the NS and BSSGP protocols.

G X P U M

G S C U
GMPS/GEPS

G E P U G
Gb

SGSN

Gb board should be GFGUG/GEPUG Front Board Rear Board


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 58

E1/T1 cable Backplane TDM Switching Backplane GE Switching

Operation Maintenance Flow

L M T

O M U

G S C U

Service Board

GMPS
Hardware is GBAM/GOMU

G S C U
E1/T1 cable Backplane TDM Switching Backplane GE Switching
HUAWEI TECHNOLOGIES Co., Ltd.

Service
Board

GEPS

HUAWEI Confidential

Page 59

Operation Maintenance Flow

GMPS OML Path:

LMT-GBAM/GOMU-GSCU-GMPS Subrack Boards

GEPS OML Path:

LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEPS Subrack Boards

BTS Configuration OML Path:

BTS is configured in GMPS LMT-GBAM/GOMU-GSCU-GEIUB-BTS

BTS is configured in GEPS LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEIUB-BTS

The OML flow in this page just should be used in Abis Over TDM

GMPS Board

GEPS Board

GTCS Board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 60

Chapter 1 BSC6000V900R008 System Description Chapter 2 BSC6000V900R008 Hardware Structure Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 61

Hardware configuration Principle

Service processing boards

Single GDPUX supplies 960 voice circuits coding/decoding, it works as resource pool in subrack. If just need 1 board, we can configed as 2 boards, Otherwise do not config as N+!. DPUX supports 3740 voice circuits frame conversion or transmission between TRAU/IP/HDLC and TRAU, We can config as N+! Mode. Single GDPUP supplies 1024 MCS-9 PDCH channel of processing packet service, supports 1024 cells at most, GDPUP is resource pool of whole system and could be inserted in rear slots; Number of GDPUP+GDPUX+GDPUC couldnt be more than 10;

GXPUM/GXPUT

GXPUM must be inserted in 0&1 slots of GMPS/GEPS fixedly; GXPUT is inserted in 2&3 slots of GMPS/GEPS by requirement, when the TRX of current subrack is less than 256, CXPUT may not be configured, if needs, its certainly;

Interface Specification

Abis: GEIUB/GOIUB support 256TRX(HR)at most, GEHUB GFGUB/GOGUB also support 384TRX(HR)at most; A: GOIUA/GEIUA are configured 5 groups per subrack at most, if A interface uses optical transport, single subrack could access 9600 CIC at most;
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 62

Typical Configuration

512TRX

Configuration A, Outer PCU, A Interface Optical, Configuration A, Inner PCU, A Interface Optical, Configuration B, Outer PCU, A Interface Optical, Configuration B, Inner PCU, A Interface Optical,

Abis Interface E1/T1 Abis Interface E1/T1 Abis Interface E1/T1 Abis Interface E1/T1

1280TRX

Configuration A/B, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration A/B, Inner PCU, A Interface Optical, Abis Interface E1/T1

Full Configuration 2048TRX

Configuration A, Outer PCU, A Interface Optical, Configuration B, Outer PCU, A Interface Optical, Configuration A, Inner PCU, A Interface Optical, Configuration B, Inner PCU, A Interface Optical,

Abis Interface E1/T1 Abis Interface E1/T1 Abis Interface E1/T1 Abis Interface E1/T1

A interface over IP and Abis interface over HDLC arent considered in typical configuration of this chapter
Please consult HUAWEI BSC6000 A interface over IP subject Please consult HUAWEI BSC6000 Abis interface over HDLC subject

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 63

Typical Configuration 512TRX

Outer PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 512TRX at most.

Left: configuration
A:1GIMS+1GMPS Right: configuration B,1GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 64

Typical Configuration 512TRX

Inner PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 512TRX at most.

Left: configuration A
1GIMS+1GMPS Right: configuration B,1GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 65

Typical Configuration 1028TRX

Outer PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 1028TRX at most.

Leftconfiguration A

1GIMS+1GMPS+1GEPS

Rightconfiguration B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 66

Typical Configuration 1028TRX

Inner PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 1280TRX at most.

Leftconfiguration A
1GIMS+1GMPS+1GEPS Rightconfiguration B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 67

Typical Configuration 2048TRX

Configuration: 1GIMS+1GMPS+2GEPS Supports 2048TRX at most.


Configuration A, Outer GBAM Outer PCU

A interface uses STM-1 as


transport model Abis interface uses E1/T1 as transport model

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 68

Typical Configuration 2048TRX

Configuration: 1GIMS+1GMPS+2GEPS Supports 2048TRX at most.


Configuration B, Inner GOMU Outer PCU

A interface uses STM-1 as


transport model Abis interface uses E1/T1 as transport model

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 69

Typical Configuration 2048TRX

Configration:1GIMS+1GMPS+ 2GEPS Support 2048TRX


Configuration A, Outer GBAM Inner PCU

STM-1 is A interface physical


transport E1/T1 is Abis interface physical transport

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 70

Typical Configuration 2048TRX

Configuration:1GIMS+1GMPS+

2GEPS

Supports 2048TRX

Configuration B Inner GOMU Inner PCU STM-1 is A interface physical transport E1/T1 is Abis interface physical transport

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 71

Abbreviation

Cabinet and Subrack Abbreviation


English Abbreviation GBCR GBSR GBAM GMPS GEPS GTCS English Full Name GSM BSC Control Processing Rack GSM BSC Service Processing Rack GSM Back Administration Module GSM Main Processing Subrack GSM Extended Processing Subrack GSM TransCoder Subrack

Boards Abbreviation Collection


Physic al OMUb GCUa SCUa TNUa XPUa Logical GOMU GGCU GSCU GTNU GXPUM GXPUT English Full Name GSM Operation Maintenance Unit GSM General ClocK Unit GSM Switching and Control Unit GSM TDM switching Network Unit GSM eXtensible Processing Unit for Main service GSM eXtensible Processing Unit for Transmission HUAWEI Confidential
Page 72

HUAWEI TECHNOLOGIES Co., Ltd.

Abbreviation
Physical DPUa DPUc DPUd Logical GDPUC GDPUX GDPUP GEIUB EIUa English Full Name GSM Data Processing Unit for CS service GSM Data Processing Unit for eXtensible service GSM Data Processing Unit for PS service GSM E1/T1 Interface Unit for ABis

GEIUP
GEIUT GEIUA GOIUB

GSM E1/T1 Interface Unit for Pb


GSM E1/T1 Interface Unit for ATer GSM E1/T1 Interface Unit for A GSM Optic Interface Unit for ABis GSM Optic Interface Unit for Pb GSM Optic Interface Unit for ATer GSM Optic Interface Unit for A GSM Fast ethernet and Gigabit ethernet Unit for A GSM Fast ethernet and Gigabit ethernet Unit for ABis GSM Fast ethernet and Gigabit ethernet Unit for Gb GSM Optic Gigabit ethernet Unit for A GSM Optic Gigabit ethernet Unit for ABis GSM E1/T1 High level Data Link Control Unit for ABis GSM E1/T1 Packet Unit for Gb

OIUa

GOIUP GOIUT GOIUA GFGUA

FG2a

GFGUB GFGUG

GOUa

GOGUA GOGUB GEHUB GEPUG

PEUa

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 73

This course mainly introduces three points as following:

BSC6000 V900R008 New Function and Features BSC6000 V900R008 Hardware Structure and System Principle while TC/BM is combination mode

BSC6000 V900R008 Typical Configuration while TC/BM is


combination mode

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 74

Thank you!