Professional Documents
Culture Documents
Benefits of Fiber Optic and Passive Optical LAN Test
Benefits of Fiber Optic and Passive Optical LAN Test
-Mark Mullins
Because passive optical LANs use singlemode fiber, they are not limited by the 100-meter
channel distance of copper but instead can reach distances of 20 kilometers. This is ideal for large
facilities, or really any facility where 100 meters is not feasible.
In addition to eliminating the distance limitation, the primary cost-saving benefits of passive
optical LANs include the ability to eliminate telecommunications rooms and the associated power
and cooling infrastructure. The smaller, lighter singlemode fiber cables used in these systems also
reduces pathway and space requirements.
Other benefits touted by proponents of passive optical LANs, and of fiber systems in general,
include improved security and eliminating the crosstalk and EMI/RFI concerns associated with
copper cabling.
Just like any fiber optic system, a passive optical LAN requires insertion loss testing. And just
like any fiber system, the overall channel loss is based on the end-to-end path between application
specific equipmentthe OLT and ONT in the case of the passive optical LAN. That means that
everything in betweencable, connectors, splitters, and splicesattributes to loss. And just like any
fiber optic system, connector cleanliness remains vital. That means the connectors should be
inspected for contamination.
For passive optical LANs, the acceptable insertion loss is a minimum of 13dB and a maximum
of 28dB at a 20km distance. The singlemode fiber used in a passive optical LAN should also be tested
at both the 1310nm and 1490nm wavelengths. And test reference cords must include the angled
polish contact (APC) style connector to match those used in passive optical LANs.
Best practices for passive optical LAN testing will be included in the upcoming international
standard IEC 61280-4-3, which in keeping with existing TIA and ISO/IEC standards, specifies a light
source/power meter for Tier 1 testing and an OTDR for Tier 2 testing in the upstream direction.