You are on page 1of 68

TELEKOM MALAYSIA BERHAD

HSBB OVERVIEW FOR RNO


MANAGEMENT-INTERNAL WIRING

NORHIDAYATI
Asst. Manager
FTTH 4, HSBB
OVERVIEW TM HSBB NETWORK

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
HSBB NETWORK

TM OFFICE CUSTOMER

2:8 1:8

OLT ODF FDC FDP FTB FWS ONU

PASSIVE ELEMENT
PON Passive Optical Network.
Standard FTTH Network

ONU
OLT connect
connect to LAN
to WAN

ONU
connect
to LAN
E-SIDE D-SIDE

Fiber Distribution Drop Cable


Central Office (CO)
Point (FDP)
Underground
Slotted Core Cable

Aerial Loose Tube


Fiber Distribution
Fiber Distribution Cable Termination Box
Cabinet (FDC)
Point (FDP) (TB)
Fiber Distribution Drop Cable Termination Box
Point (FDP) (TB)

Indoor Cable ONU


Bend Insensitive
Patchcord

Fiber Socket
FASC
Content Triple Play
Triple play Voice, Video and Data

Voice VoIP (Voice over IP) is used


instead of conventional PSTN system.
VoIP lowers telephony cost

Video IPTV over PON offers


broadcast TV and also Video on
Demand at SDTV and also HDTV
quality

Data High Speed Broadband at


100Mbps and 1Gbps are currently
available.
CUSTOMER PREMISE INSTALLATION FOR
FTTH

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
Chapter 1: Introduction

Check Power Level

External Wiring

Internal Wiring
MAIN PROCESS ACTION DETAILS

1.1 CALL CUSTOMER TO CONFIRM APPOINTMENT


FOR INSTALLATION.
1.0 COMMUNICATION WITH
CUSTOMER 2.1 INFORM CUSTOMER TO PERFORM INSTALLATION.

2.2 PERFORM CUSTOMER PREMISE SURVEY.


2.0 SITE SURVEY ASSESSMENT
SITE PREPARATION.

3.0 EXTERNAL AND INTERNAL 3.1 FA-SC CONNECTOR INSTALLATION.


INSTALLATION / OPERATION 3.2 DROP FIBER PULLING AND FTB INSTALLATION.
3.3 DRILLING OPERATION.
3.4 INTERNAL WIRING INSTALLATION
4.0 ONU INSTALLATION 3.5 FIBER WALL SOCKET INSTALLATION
AND OPERATION
4.1 INSTALL ONU INSIDE CUSTOMER HOUSE.
4.2 INSTALL RG AND SET TOP BOX INSIDE CUSTOMER HOUSE.
5.0 RG AND SET TOP BOX
INSTALLATION AND CONFIGURATION
5.1 MAKE CONNECTTION FROM RG AND SET TOP BOX.

6.0 TESTING, DEMONSTRATION 6.1 TESTING


AND ACCEPTANCE BY CUSTOMER 6.2 DEMONSTRATION ON SERVICES.
6.3 CUSTOMER WILL BE EVALUATE THE TESTING AND DEMO.

7.0 SITE CLEANLINESS 7.1 CLEAN CUSTOMER PREMISE AFTER INSTALLATION.


Pull the Drop Fiber
Check Power Level

Use power meter to measure


optical power at 1490nm.

POWER METER Power level at FDP -23.5 dBm.

Power Level at FTB -24.0 dBm.

Power Level at FWS -25.0 dBm.


Drop & Indoor Cables
FTTH Overhead Installation

Overhead DP

FTB

160 cm

Customer
FWS house
Drop fiber 30 cm

Note : FTB will be drilled onto surface wall.


Drop fiber pulling and FTB installation

Pull drop fiber with the FA-SC connector attached


from FDP to the premise.
Clean the connector ferrule
before attaching to FWS.

Attach one end of the drop fiber with the FA-SC connector to
the FDP port to be used for the particular customer. Attach
the other end of the drop fiber to the FTB port.

Installation of FTB will differ according to type of customer premise.


Customer premise are define as:
SDU Single storey & double storey terraced, semi detached bungalow
house and shop lot.
MDU Condominiums, apartments and high rise buildings.
Termination IB wire at ring pole and D-hook
Drilling Operation
To make sure less breaking
to the wall inside the house
Drilling must be inside the house to the outside house while drilling operation.

To rebuild the surface of wall


Plaster filling must be applied after drilling operation that broken because of drilling.

Use the metal detector to detect metal piping inside the wall
Metal Detector
Fiber wall socket Installation

Fix the fiber wall socket to the wall ensuring a height of at Fiber wall socket will be put
at 30cm above the floor so
least 30cm from the floor. This is to avoid environmental it will protect fiber wall socket
risks that may arise if it is installed lower. from collecting dust.

Fix the fiber wall socket using proper screw to ensure


stability of installation. Avoid using stickers such as Make sure screw at
fiber wall socket is tight.
double sided tapes.

Clean the connector ferrule


before attaching to FWS.

Connect the bend insensitive patch


cord/internal fiber cable to the fiber wall Use visual inspection probe
socket. to confirm the cleanliness
of the ferrule.
Fiber wall socket Installation contd
Using a PON power meter, test the total link loss received
at the fiber wall socket. Absolute power measurement Clean the connector with
connector cleaner after
should be more than -25dBm. If the value is less than - and before the test.
25dBm, clean the connector using alcohol and lint-free
cloth.

Repeat measurement of absolute power level. If the


measurement is more than -25 dBm, test the loss The reading should be 0.5dB
or less at every termination.
measurement at every connection (FTB & FWS) to
ensure it is within specification.
FASC Installation
FASC Installation
FASC Installation
Typical underground feeding setup at customer house

Customers House FTB

PVC
Pipe

10m
Pit

Drain

4m 15m 6m
FDC Pedestal FDP Joint Box Joint Box Underground GI

Legend
- Customer premise
- TM boundary
FTTH Underground Installation (Using Existing Piping)

Wall
House
FTB

Wall fence

160 cm
Dinding Rumah
Surface
DP
PVC grey Pintu Pagar
pipe
Lantai Laman Rumah

Floor
Jointing
Box

Jointing
Box

Existing underground
GI pipe

Note : 1) FTB will be drilled onto surface wall.


FTTH Underground Installation (Using New Piping)

FTB
Wall
House
Wall fence

160 cm
Dinding Rumah Surface
10 cm DP
Pintu Pagar

Lantai Laman Rumah


PVC grey
pipe

Jointing
Box
Underground
GI pipe

Note : 1) PVC pipe will fixed on the surface of the wall fence using stainless still clips
(drilled to the wall)
2) FTB will be drilled onto surface wall.
Layout In Customer Premise For Landed

Room 2 Room 3
Room 1 Kitchen

Living Room
Dining Area
RG
Room 4
BTU

Internal Fiber Raceway

Legend

Internal wiring fiber


Bend insensitive fiber
RJ 45
Installation Of BTU And CPE

ADSL Splitter
ADSL Modem

Existing Phone Set

BTU

Fiber Wall
Socket Residential
Gateway
DECT Phone Set
Legend
RJ11
RJ45
AV Cable
Bend insensitive fiber
Set Top Box
Existing TV Set
Workspace Cleanliness
Ensure all the packaging materials (including the instruction
manuals) are properly put away and handed over to
customer.

Ensure all the tools and test gears are stored back in the
toolbox.

Ensure that the workspace inside and outside customer premise


is clean. It is recommended to use a vacuum cleaner to clean the
working area.
CUSTOMER PREMISE INSTALLATION FOR
FTTH HIGH RISE

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
Chapter 2: FTTH High Rise

With SDF & Riser

Without SDF & with riser


DESIGN OF FTTH NETWORK IN HIGH RISE
RESIDENTIAL BUILDING
RESIDENTIAL BUILDING WITH SDF ROOM &
CABLE RISER (SCENARIO 1)

Figure 1: FTTH network at residential building with SDF


and riser. (Method 1)
RESIDENTIAL BUILDING WITH SDF ROOM &
CABLE RISER (SCENARIO 1)

Figure 2: FTTH network at residential building with SDF


and riser. (Method 2)
RESIDENTIAL BUILDING WITHOUT SDF ROOM &
CABLE RISER (SCENARIO 2)

Figure 3: FTTH network at residential building without SDF


and with riser.
FDP & Tag Block
Measure Distance using Walker Meter
Pull the Drop Fiber into Micro duct
Pull Drop Fiber at Riser
CUSTOMER PREMISE INSTALLATION FOR
VDSL2

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
Chapter 3: VDSL2+

Jumpering at the tag block

Copper Quality Test


Jumpering at the tag block

For customers who were previously using Streamyx service, ensure that
the jumpering for ADSL IN and ADSL OUT are disconnected before
installation. The jumpering for Streamyx could be at MDF (for DSLAM) or
SDF (for RDSLAM/MSAN).
Ensure proper termination of jumpering. The quality of the termination
may impact the line quality at customer end.
For VDSL2 circuits with the customers maintaining their DEL line, verify
that the telephone number is correct .
Case 1:
Mawi upgrade Streamyx to Unifi. But he want to
remain existing telephone number.
Solution:
Case 2:
Rosyam upgrade Streamyx to Unifi. But he
doesn't mind to use new phone number.
Solution:
Reading at tag block
Reading from wall socket
Testing VDSL2+ modem
Installation requirements and setup.

Balcony

BTU
Room 2
Living
Room 1 RG

Refer to next slide


Dining
Bath 1 Bath 2
Room 3

Kitchen
Yard
Legend
Wall socket
RJ45 DP
Internal copper
Installation Of New Splitter, BTU And CPE for VDSL2

VDSL2 Modem
ADSL Modem
VDSL2 Splitter
ADSL Splitter
DECT Phone

Faceplate Residential
Gateway

Legend Existing Phone Set

RJ11
RJ45
Set Top Box
AV Cable Existing TV Set

Note: Require extra 4 power points (for VDSL2 modem, RG, Set-top box, DECT phone)
Wi-Fi USB WORK INSTRUCTION

Make sure that you have the following items. If any of the items is damaged or
missing, please contact SOC immediately.
WL552USB
Easy Start Guide
Resource CD contains WL552 Utility installer, and User Manual
USB Cable
FTTH & VDSL2
Determining location of CPE
1

Location of CPE (including BTU, RG, STB)


must be suitable i.e. near the television.

Limited space Best Location


FTTH & VDSL2
2
Determining location
of CPE

Best Location
FTTH
Quality of drilling works
3

Installer must be skilled in performing


drilling works to avoid damage to
customers wall.
FTTH
Blocked existing underground cable
4

duct
For certain customer premise with
underground DP and cable duct, there are
cases where the ducts are blocked. For
blocked duct that cannot be
recovered/rectified, new cable route need
to be done. This would sometime involve
hacking of concrete walls or floor tiling,
Example of Underground Installation for FTTH

Testing on Existing underground GI pipe. Ok but new piping required to place FTB.

Briefing to customer on external plan (to place FTB)


Example of Underground Installation for FTTH using
Microduct
Example of Overhead Installation for FTTH
Example of inside house Installation for FTTH
SAFETY PRECAUTION

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
1.Road Safety
2.Manhole Safety.
3.Pole Safety
4.Fiber Safety
SAFETY
TEST GEARS

What have you done to save energy today?


A black interface on a CRT monitor uses 25% less electricity as compared to a white interface.
Test Gear
Test Gear
Test Gear
Thank you!

We Will Broaden Your Future