Professional Documents
Culture Documents
Kickoff Meeting
ZTE & PARTNER
Sharing session
Internal use only▲
TABLE of Content
MeasPrio
U880->U2100 maximum can add 32 neighbor, propose to add as far as possible
0: The highest measurement priority
1: The second measurement priority
© ZTE All rights reserved
4 2: The lowest measurement priority
Internal use only▲
COVERMEABALSWCH 1 1 ldBalHsdNumSwch 1 1
rabAssLBSw 1 1 ldHsdUserNumThd 1 5
callHoldLBSw 1 0 deltaHsdUsrNumTd 0 1
rabAssMeaBalSw 1 1 ldHsdNumOptSwch 1 1
comToDchMeaBalSw 1 0 ldBalHsdSwch 1 1
dcHsdschSupptInd 0 1
RRU Type Number of PA Power Available Support Band Power Recommendation Usage Scenario Notes
DCS1800 DCS 5 W per TRX
A8602 M1821(A4B) 3 40 W per PA LTE1800 LTE 10 W per Cell Combat GUL Mode Support
UMTS2100 UMTS2100 5 W per Cell
LTE1800 (2 PA) LTE1800 0.2 MIMO
R8108 F1821(A5A) 4 0.1 W per PA QCELL GUL Mode Support
UMTS2100 (2 PA) UMTS2100 0.05 W per Cell
LTE1800 (2 PA) LTE1800 0.2 W MIMO
R8108 F1821(A5A) 4 0.1 W per PA QCELL GUL Mode Support
UMTS2100 (2 PA) UMTS2100 0.05 W per Cell
UMTS2100 (2PA)
UMTS2100 0.05 per Cell
LTE1800 (2PA)
R8119 M182126(A1A) 8 0.1 W per PA LTE1800 0.2 W MIMO QCELL GUL Mode Support
LTE2600 (2PA)
DCS1800 0.05 per TRX
DCS1800 (2PA)
GSM900 GSM900 20 W per TRX
R8862 S9000(A6A) 2 60 W per PA UMTS900 UMTS900 20 W Normal Site GUL Mode Support
LTE900 LTE900 20 W
R8863 S2100(A8A) 3 80 W per PA UMTS2100 UMTS2100 26.6 W per Cell Normal Site
DCS1800 DCS1800 20 W per TRX
R8872A S1800(A8A) 2 80 W per PA Normal Site GL Mode Support
LTE1800 LTE1800 40 W MIMO 10 MHz
GSM900 GSM900 20 W per TRX
R8881 S9000(B8B) 1 80 W per PA Normal Site Only G or U
UMTS900 UMTS900 20 W
R8882 S1800(B6C) 2 60 W per PA DCS1800 DCS1800 20 W per TRX Normal Site
R8882 S2100(B) 2 60 W per PA UMTS2100 UMTS2100 30 W per Cell Normal Site
GSM900 GSM900 20 W per TRX
R8882 S9000(B) 2 60 W per PA UMTS900 UMTS900 20 W Normal Site Only GU or GL
LTE900 LTE900 20 W
R8882-GUL1812 2 60 W per PA DCS1800 DCS1800 20 W per TRX Normal Site
R8984E S2300 2 40 W per PA LTE2300 Normal Site
RSU40-U216 1 60 W per PA UMTS2100 UMTS2100 20 W per Cell Normal Site
RSU60E-GU188 1 80 W per PA DCS1800 DCS1800 20 W per Cell Normal Site
GSM900 GSM900 20 W per TRX
RSU60E-GU908 1 80 W per PA Normal Site Only G or U
UMTS900 UMTS900 20 W
RSU60-GU908 1 80 W per PA GSM900 GSM900 20 W per TRX Normal Site
RTR-U214 1 40 W per PA UMTS2100 UMTS2100 13.3 W per Cell Normal Site
RTR-U216 1 60 W per PA UMTS2100 UMTS2100 20 W per Cell Normal Site
TRB-G904 1 40 W per PA GSM900 GSM900 20 W per TRX Normal Site
2G Power Setting :
OMMB Setting :
1. Power standard / Trx 20 Watt
2. If Power cant meet with min 20 Watt /Trx, BCCH Trx must set to 20 Watt
3G Power Setting :
1. CPICH setting must balance F1,F2,F3 same value
2. OMCR Power <= OMMB Power setting
3. Allocation per Carrier min 20 Watt refer to max RRU Support
1. 3X80 , @sector 80 Watt @ carrier 80/3=26.6 watt= 44.2 dBm
2. 2X60, @sector 2X60 Watt @ Carrier 30 Watt = 44.7 dBm
4G Power Setting :
1. Min Power 4G for 10 Mhz = 2X20 watt (MIMO) = RS Power 15.2
2. Min Power 4G for 15 Mhz = 2X30 Watt (MIMO)= RS Power 15.2
© ZTE All rights reserved
9
Find OMCB Location > Start NE Management
Configuration Management > Find Site > 2G OMCB
Planning Data Export
Power Config