Name and Function of Each Part
RTC

Drive Setup
Hook for fixation

XG-PD Option board cover

Battery cover
XG5000
Hook for fixation
Diagnosis
Battery specifications

Item Specification
Voltage/Current DC 3V / 220 mA
Warranty period 3 years (ambient temp.)

Purpose Program and data backup,


RTC operation in case of power failure
Specification Manganese Dioxide lithium battery
Dimension (mm)  20 X 3.2 mm

※ If battery is getting low, main unit cause the warning, ‘battery voltage low warning’.
The user can check it by error LED, flag and error message of XG5000

1/4
RTC Option
How to use
RTC
Economic & standard type (XBC-DxxxE/S(U) doesn’t support RTC function.
If you equip RTC option board, you can use this function for time management of system or error log.
Drive Setup RTC function is executed steadily when power is off or instantaneous power cut status.

XG-PD ▶XG5000>>
1.Click『Online』 >>『PLC Information』
2.Click PLC RTC tap of PLC Information』
XG5000
3. ‘Synchronize PLC with PC clock’ or
4 change the setting value of Time box
Diagnosis and press ‘Send to PLC’

2/4
RTC Option
application in program
RTC
 special relay for time data
Drive Setup
Special relay area Data Contents
XG-PD
F053 H0710 10year 07month

XG5000 F054 H1729 29date 17hour

F055 H1020 10second 20minute


Diagnosis
F056 H2004 20XXyear, Thursday

 example program using time data

3/4
RTC Option
application in program
RTC
 Modification of clock data by program
Write clock data to temporary device (P, M, K, L, Z, U, D, R) and turn on/off input
Drive Setup contact point M0100. (If date and day data is not matched, Write is not available.)

XG-PD

XG5000

Diagnosis

 example program using time data

area Content
M0010 Month, year
M0011 Hour, date
M0012 Second, minute
M0013 Centaury, day

Number 0 1 2 3 4 5 6
Day Sunday Monday Tuesday Wednesday Thursday Friday Saturday

4/4
Memory Module
Memory Module Specification
RTC
RUN LED

Memory Module WRITE LED


READ LED

XG-PD
USB 1 : READ mode
XG5000 RS-232C connector 3 : WRITE mode
connector 5 : PADT I/F mode

Diagnosis ※ Memory module is not supported at the version below


(XBMS: V2.5 or less, XBCH: V1.8 or less, XECH: V1.2 or less)
Battery specifications

Item XBO-M2MB Ref.

Memory capacity 2MByte


Memory type Flash Memory
Specification USB supported, Program Read/Write
1. RUN
Indicator LED 2. WRITE
3. READ
Operating mode setup Mode setup by rotary switch
RS-232C communication connecter,
Operating power supply 5V
USB connector
1/4
Memory Module
How to use memory module
RTC
You can save user program safely or download user program to PLC without special handling when
user program is damaged by using external memory module in XGB PLC
Memory Module

XG-PD
READ/WRITE
XG5000

Diagnosis
1. From PLC to M2MB
1 : READ mode
1) Set the switch of memory module as “1”
2) Install memory module at the RS-232C port of main unit
- After installation, program and parameter is saved into memory module and READ LED is on
- If Saving program and parameter is complete, READ LED is off
3)Last, Separate memory module from main unit

2. From M2MB to PLC


3 : WRITE mode
1) Set the operating mode of XGB PLC as STOP
(b) Set the switch of memory module as “3”
2) Install the memory module in RS-232C port.
- PLC program and parameter (including communication) is written and WRITE LED is on
- If saving program and parameter is complete, WRITE LED is off.
3)Last, Separate memory module from main unit

2/4
Memory Module
How to use memory module
RTC

Memory Module
XG5000 READ

XG-PD
1. From M2MB to XG5000
XG5000 5 : PADT mode
1) Set the switch of memory module as “5”
2) Connect XBO-M2MB to USB port of PC
Diagnosis 3) Select Project  open from Memory & click “OK”.

4) “Writing completed” window appears

3/4
Memory Module
How to use memory module
RTC

Memory Module
XG5000 write

XG-PD
1. From XG5000 to M2MB
XG5000 5 : PADT mode
1) Set the switch of memory module as “5”
2) Connect XBO-M2MB to USB port of PC
Diagnosis 3) Select Project  Write to Memory on XG5000 menu & click “OK”.

4) “Writing completed” window appears

4/4
Analog In/Out

RTC ▶ XBO-AH02 specification

Memory Module

Analog Module

XG5000

Diagnosis

1/9
System Proposal
System Component … XGB
RTC
▶ I/O synchronization

Memory Module

Analog Module

XG5000

Diagnosis

3/9
System Proposal
System Component … XGB
RTC
▶ check I/O Parameter
Memory Module

Analog Module

XG5000

Diagnosis

4/9
System Proposal
System Component … XGB
RTC
▶ Register U Device

Memory Module

Analog Module

XG5000

Diagnosis

▶ Check variable /comment

6/9
System Proposal
System Component … XGB
RTC ▶ Set Analog module parameter

Memory Module

Analog Module

Double Click
XG5000

Diagnosis

▶ Setting Analog Input parameter

▶ Setting Analog Out parameter

7/9
System Proposal
▶ Device Monitoring System Component … XGB
RTC
▶ sample Program
Memory Module

Analog Module

XG5000

Diagnosis

U0A.06.0 is a signal for Analog output enable .

▶ U Device
Analog data Register
A : 2’ position of option board : Ch0
U0A.04 04 : Analog input
06 : Analog output
02 : Ch0
Slot No : 01 Slot
Base No : 0

8/9
System Proposal
▶ special module monitoring
System Component … XGB
RTC
XG5000>>Monitoring
Start monitoring
Memory Module

Analog Module

XG5000

Diagnosis

Special module monitoring

9/9