Hopper Weighing System - Rev3
Hopper Weighing System - Rev3
WELCOMES
CONTINUAL IMPROVEMENT AND DEVELOPMENT PROJECT
Department :- DRP
HOD & Facilator :- M S Vas
Group Leader :- P.L.NAKHALE
A.P Sadhu
Team Members C.Hatwar
S.Roy
U.W.Jagnade
S..S.Waghmare
PROBLEMS BEFORE MODIFICATION
1 The finished DRI is comming in direct contact with air and there is
always chance of re-oxidation of DRI. Hence GRADE of DRI reduces.
Air is getting polluted due to dust is coming from cooler discharge area.
2
This dust is un-burnt coal fines.
One person is always required at cooler area to adjust damper position.
3
Operator is continuously required to adjust the flow of material.
Belt conveyor BC26 is a long belt of length 410 meter. The average belt
4 life is 300 days. But belt is getting damaged due to hot material is coming
in direct contact with belt. Hence, belt life is getting less than 300 days.
BEFORE MODIFICATION PHOTO
PROJECT PLAN
If No,state the
reason - - - -
REVIEW BY HEAD OF DEPARTMENT AUGUST 2016 - NOV
2016
Month Sep-16 Oct-16 - Nov 16 Nov-16
Project is in Yes Yes No
progress
If Yes,state the 1. Discharge 1. PID Auto control
progress chute modified. logic prepared in
Opening of Rockwell PLC
hopper and 2.System trial
gate positioner taken found ok but
rod is still pending for
provided. extra suction line
2. Mounting connection to ABC
arragement chamber for
done for utilisation of un-
invertor & burnt carbon fines
interfacing for steam
done with generation
feeder
If No,state the Suction line
reason work is in
REVIEW BY HEAD OF DEPARTMENT DEC 2016 - MARCH
2017
Jan-17 Mar-17
Month Dec-16 Feb-17
Project is in progress No Yes Yes Yes/No
If Yes,state the Suction line Systen is
progress work working
completed & successf
finally system uly
taken in line.