Content

Information Collection and Preparation

BSC6900 Deployment

Common Faults

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 2


Necessary Information

 Software version
 License
 Network design
 RF database
 MML configuration
 Acceptance test document

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 3


Network Structure
MGW/MSC
BSC Cabinet TC Cabinet

Abis A
Ater

SGSN

Gb

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 4


Interface Hardware

1. Abis interface
 How many BTS? => How many Abis interface board (EIUa/OIUa) t
o install? => How many BM subrack to install?

2. Ater interface
 How many Ater resources to support?
=> How many Ater interface board to install?
 How many Ater Signaling to support?

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 5


External Interface Hardware

3. A interface
 How many A resources (CICs) to support?
=> How many A interface board to install?
 How many A Signaling to support?
 Which A Signaling type will be used? 64K C7 or 2M HSL?

4. Gb interface
 Gb over FR => Which board will support? (PEUa)
 Gb over IP => Which board will support? (FG2a)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 6


Internal Service Hardware

1. CS Control plane : manage the user plane resources, control plane reso
urces, transmission resources and process service on control plane of the
system. Supporting 270 TRXs, 270 cells, 270 BTSs, and
Processing capability of the main
492,000 Max equivalent BHCAs (Busy Hour
control XPUa board
Call Attempts)
Supporting 360 TRXs, 360 cells, 360 BTSs, and
Processing capability of the non-
656,000 Max equivalent BHCAs
main control XPUa board

2. CS User Plane: processes GSM voice services and GSM data services.
Supporting 960 TCH/Fs; supporting 3,740 IWF
Processing capability
flow numbers

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 7


Internal Service Hardware

3. GPRS: depends on the number of PDCH configured on BSC

Processing the PS services on up to 1,024


simultaneously active PDCHs where signals are
coded in MCS9
Processing capability
Processing in a cell the PS services on up to 48
simultaneously active PDCHs where signals are
coded in MCS9

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 8


Content

Information Collection and Preparation

BSC6900 Deployment

Common Faults

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 9


Hardware Installation

1. BSC & TC cabinet Installation


2. Power cabinet (PDF) installation
3. Subrack Installation
4. Subrack hardware configuration (DIP switch)
5. Board Installation
6. Install SCU/TNU cable between subracks
7. Install interface cable: Abis, Ater, A and Gb
8. Install external source clock (if any)
9. Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 10


Commissioning
1. Power on BSC6900
2. OMU Software Installation
3. OMU Commissioning
4. Activate the license
5. O&M link configuration
6. Hardware configuration
7. Loopback test for E1 cable
8. TX/RX power test for Optical cable
9. Interface configuration
10. Interface verification

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 11


First Call Test

1. Install one BTS test in equipment room.


2. Adjust the output power with small cove
rage.
3. Cooperate with MSC/SGSN to configure on
e test site.
4. Make voice call test and SMS service
5. Try data service with maximum of EDGE s
peed
6. Perform handover call test

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 12


Verification before On-Service

1. Board switch-over test


2. Board reset test
3. ACIC test
4. Acceptance test document
5. M2000 can monitor BSC alar
m remotely
6. OMC confirmation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 13


BSC On-Service

1. On-air one new site firstly.


2. Monitor the KPI within acceptable days.
3. Continue on-air with batch of new sites.
4. RF team perform drive-test after on-air.
5. RF team analyze the log file and find out the problem (cr
oss feeder, lack of neighbors, antenna…) if any.
6. RF team will give parameters to optimize the KPI. (option
al)
7. OMC team monitor alarms and KPI on system.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 14


Content

Information Collection and Preparation

BSC6900 Deployment

Common Faults

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 15


SDH/SONET Tributary Loss of Multifr
ame
1. Fault description: Physical links or TX/RX power are normal, b
ut all of E1 ports are in DOWN status.

2. Root cause: Frame structures are not matched with peer device

3. Solution: Modify the correct frame structure by command SET E1


T1 with parameter E1_DOUBLE_FRAME or E1_CRC4_MULTI_FRA
ME 16
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Silent or Noise Calls

1. Fault description: When engineer perform first call tests, the


re are also many calls which occur silent or n
oise calls.

2. Root cause:  the sequence of tributaries in an SDH frame is no


t matched due to different vendors’ standard.
OR the quality of transmission is bad.

3. Solution: Modify the  tributary numbering by command SET OPT


with parameter ALCATEL_MODE or LUCENT_MODE or HUAWEI_M
ODE

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 17


Wrong TX/RX Optical Connection

1. Fault description: The links belong to Optical connection type


are not UP.

2. Root cause:   There are some optical ports have TX power, but
don’t have RX power or vice versa.

3. Solution: Install Optical connection correctly, then check TX/


RX power exist in each port.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 18