Professional Documents
Culture Documents
012.1 - Cat-6060 - Central Greasing System - Undercarriage
012.1 - Cat-6060 - Central Greasing System - Undercarriage
Cat® 6060/6060FS
2
Control Panel with second pump Service Training
-5Y1
-5Y5 -5Y3 -5Y4
-5B7 -5B6
-5Y2
-5B4
3
Control Panel Service Training
On/Off Solenoid
for Grease Pump
Undercarriage System
-5Y4
Unloader Valve
Undercarriage System
-5Y5
From Undercarriage
Grease Pump
Servo Oil
Tank Return
Oil / Grease
Grease Supply
Grease Tank Return
4
Grease Pump Service Training
Active Oil
Pressure on
Grease Pump
Example:
Servo Pressure: 48 bar
5
1000kg Tank – 2 Pumps Service Training
6
Undercarriage Grease Supply Service Training
to the Injectors
8
Grease Injectors Service Training
9
Grease Injectors Service Training
0,5bar
11
Load Rollers with double Lube System Service Training
0,5bar
12
Service Training
Load Rollers with double Lube System
13
Service Training
Load Rollers with double Lube System
14
Greasing System Function Service Training
Grease
Grease Pump “ON” Grease Pump “ON”
Pump
Travel
Travel Function “activated”
Function
180
Pump
Pressure
[bar]
50
[Time]
min. 5 s max. 30 s max. 60 s max. 60 s 5s max. 30 s max. 60 s
15
Greasing System Function Service Training
As well in the normal mode as in the test mode the following conditions must be given:
• The engine must be running.
• The grease drum must not be empty.
• There must not be any error message.
• No “50bar pressure built up” after start of the pump within 30sec (t2 – t1)
• No “50bar to 180bar pressure built up” within 60sec (t3 – t2)
• No “180bar to 50bar pressure decrease” after switch off the pump within 60sec (t4 – t3)
=>Fault messages can only be deleted by pressing the reset button (for 1 sec).
BCS fault messages (without grease pump being switched off) undercarriage:
The test mode is initiated by pressing the reset button for 5 sec. The pump operates 15 min. continuously.
The test mode can be stopped by pressing the reset button for 1 sec !
16
More Information? Service Training
Hey Fellows,
17