All about Vaporizers

All about VAPORIZERS

Vapor 2000 D-Vapor

2 | 29 All about vaporizers | 01/12/2009


Vapor 2000

 Benefit / USP

 Filling systems

 Mounting systems

 How does it work?

 Technical Data

3 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Benefits/USP

 Lifetime calibration – no factory overhaul – no recalibration

 Tank capacity for 1 full bottle of liquid agent

 Transport position of control dial for innerclinical transport without draining the
Vapor 20000

 All mounting systems available: Draeger mount, selectatec compatible mount, cage
mount, fix mount, auto exclusion

 All filling systems available: funnel fill, Abbott Quick Fil and Draeger Fil

 Wide temperature range during operation: 10 C – 40 C


4 | 29 All about vaporizers | 01/12/2009
Vapor 2000/ D-Vapor
Different filling system

Draeger Fill Baxter Safe-T Fill

Funnel filling

Keyed filling Abbott Quik fil

5 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Filling system

Draeger Fill
§ New filling system for Vapor 2000
§ Superior ergonomic filling procedure,
easy to handle, no spillage of liquid
agent
§ Has replaced the keyed filling system
§ Available for Halothane, Isoflurane and
Sevoflurane
§ Not available for Enflurane
§ Small agent specific adapter for the
bottle

6 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Filling systems

Keyed filling system


§ Standard filing system for many years,
has now been replaced by the new
Draeger fill filling system
§ Still available for Enflurane until end of
2006

7 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Filling systems

Funnel filling system


 Non coded, non agent specific filling
system
 Just pour the agent into the vapor
 Not approved in CE market

8 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Filling systems

Abbott Quik fil filling system


 System patented by Abbott for use with
Sevoflurane Vaporizers. Available for
Draeger and Abbott Sevoflurane
vaporizers.
 Abbot Sevoflurane bottles comes with
crimped adapters
 Separate Quik fil adapters available in
selected countries only by permission of
Abbott

9 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Available mounting systems for Draeger Vaporizers

Draeger Mount Fix Mount Selectatec Cage mount


compatible mounting
adapter

10 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Draeger Mount:
 Specific mounting adapter for all
Draeger anesthesia machines
 1 or 2 vaporizer mounting systems
available with interlock 2 exclusion
system to prevent the use of 2
vaporizers simultaneously

11 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Fix Mount:
 For adapting a vapor to a NAD
Narkomed anesthesia machine
 The vapor is fixed to the Anesthesia
Devices

12 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Selectatec compatible mounting


adapter:
 For use of vapor 2000 with anesthesia
machines which have a selectatec
mounting system
 Exclusion system is integrated in the
mounting adapter. Works for 2 and 3
vaporizers selectatec mounting system

13 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Draeger auto exclusion mounting


adapter

 New Draeger mounting adapter


(patented). Integrated exclusion system
for superior ergonomic handling. Works
with 2 and 3 vaporizers auto exclusion
mounting systems.

 A Draeger Vapor with auto exclusion


adapter will also work with the Draeger
mount system

14 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Cage mount

 Mounting system for fix mount of the


vapor to a rail system. External fresh gas
hoses are connected with cones to the
vaporizer mount.

15 | 29 All about vaporizers | 01/12/2009


Vapor 2000
How does it work?

1 Vapor inlet
2 Vaporizing chamber-bypass 8

3 Additional bypass 3
5
4 Flow control cone 2
1
4
5 Vapor outlet 7a
10
6 Vaporizing chamber 7b
9
7a, 7b Valves
8 Control dial
9 Saturated wick
6
10 Temperature compensator

16 | 29 All about vaporizers | 01/12/2009


Vapor 2000
Technical Data

 Concentration range
– Halothane: 0,2 to 6%
– Enflurane: 0,2 to 8%
– Isoflurane: 0,2 to 6%
– Sevoflurane: 0,2 to 8%
 Temperature range
– Ambient and Vapor temperature:
 During operation: 10 to 40°C
 During shut-down (filed, control dial at „T“): 0 to 40°C
 During storage (empty, dry wick): -20°C to 70°C
 Flow range
– 0,2 to 15l/min
– 0,2 to 10l/min for concentrations ≥ 5vol.%
 Maximum angle of tilt
– During transport (control dial at „T“) any position and angle
– During operation 30°
 Filling volume for anesthetic agent
– About 360ml with dry wick
– About 300ml with moist wick

17 | 29 All about vaporizers | 01/12/2009


D-Vapor

 Benefit / USP

 Filling systems

 Mounting systems

 How does it work?

 Technical Data

18 | 29 All about vaporizers | 01/12/2009


D- Vapor
Benefits/USP

 Lifetime calibration – no factory overhaul – no recalibration

 Tank capacity for 1 full bottle of Desflurane

 Transport position of control dial for innerclinical transport without draining the D-
Vapor

 All mounting systems available: Draeger mount, selectatec compatible mount, cage
mount, fix mount, auto exclusion

 Internal battery for short power fail bridging

 Light weight
19 | 29 All about vaporizers | 01/12/2009
Vapor 2000/ D-Vapor
Different filling system

Draeger Fill Baxter Safe-T Fill

Funnel filling

Keyed filling Abbott Quik fil

20 | 29 All about vaporizers | 01/12/2009


D- Vapor
Filling systems

Baxter Safe-T Fill filling system


 System patented by Baxter for use with
Desflurane Vaporizers. Available for
Draeger and Baxter Desflurane
vaporizers.
 Baxter Desflurane bottles comes with
crimped adapters

21 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Available mounting systems for Draeger Vaporizers

Draeger Mount Fix Mount Selectatec Cage mount


compatible mounting
adapter

22 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Draeger Mount:
 Specific mounting adapter for all
Draeger anesthesia machines
 1 or 2 vaporizer mounting systems
available with interlock 2 exclusion
system to prevent the use of 2
vaporizers simultaneously

23 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / Adapters

Fix Mount:
 For adapting a vapor to a NAD
Narkomed anesthesia machine
 The vapor is fixed to the Anesthesia
Devices

24 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Selectatec compatible mounting


adapter:

 For use of vapor 2000 with anesthesia


machines which have a selectatec
mounting system

 Exclusion system is integrated in the


mounting adapter. Works for 2 and 3
vaporizers selectatec mounting system

25 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Draeger auto exclusion mounting


adapter
 New Draeger mounting adapter
(patented). Integrated exclusion system
for superior ergonomic handling. Works
with 2 and 3 vaporizers auto exclusion
mounting systems.
 A Draeger Vapor with auto exclusion
adapter will also work with the Draeger
mount system

26 | 29 All about vaporizers | 01/12/2009


Vapor 2000 / D-Vapor
Mounting systems / adapters

Cage mount
 Mounting system for fix mount of the
vapor to a rail system. External fresh gas
hoses are connected with cones to the
vaporizer mount.

27 | 29 All about vaporizers | 01/12/2009


D-Vapor
How does it work?

28 | 29 All about vaporizers | 01/12/2009


D-Vapor
Technical data

 Concentration range
– Sevoflurane: 0,2 to 8%
 Temperature range
– Ambient and Vapor temperature:
 During operation: 10 to 40°C
 During shut-down (filed, control dial at „T“): 0 to 40°C
 During storage (empty, dry wick): -20°C to 70°C
 Flow range
– 0,2 to 15l/min
 Maximum angle of tilt
– During transport (control dial at „T“) any position and angle
– During operation 10°
 Filling volume for anesthetic agent 340ml
 Warm up time 5min
 Battery power during power failure 5 min
 Voltage 100V-15% till 127 V +10%
230 V ± 10%
 Frequency 50Hz – 10% till 60 Hz +10%
 Power consumption ≤ 220 W (warm up phase)
≤ 100 W (standard phase)