SINAMICS
SINAMICS S120 - News
March 2007
Automation and Drives
New components
components Basic Line Module (BLM) booksize format
New functions
Basic Line Modules are non-regulated infeed units
STARTER
Planned release and Order Nos. [MLFBs] for the internal air-cooled
version:
20kW (scheduled release 03/2007) 6SL3130-1TE22-0AA0
40kW (scheduled release 06/2007) 6SL3130-1TE24-0AA0
100kW (scheduled release 03/2007) 6SL3130-1TE31-0AA0
Planned release and Order Nos. [MLFBs] for the Cold-Plate cooling
version:
20kW (scheduled release 03/2007) 6SL3136-1TE22-0AA0
40kW (scheduled release 06/2007) 6SL3136-1TE24-0AA0
100kW (scheduled release 03/2007) 6SL3136-1TE31-0AA0
Power rating
New components
components 20kW and 40kW with diodes
100kW with thyristors
New functions
Control/communication
All BLMs will be implemented with 20kW 40kW
STARTER 100kW
DRIVE-CLiQ (ABO).
Chopper
20kW and 40kW integrated
100kW external
Cooling types
Internal air cooling: 20kW ; 40kW ; 100kW
Cold Plate: 20kW ; 40kW ; 100kW
New components
components
New functions
STARTER
New components
components Motor Modules booksize with new gating unit/DRIVE-CLiQ Asic
New gating unit/DRIVE-CLiQ Asic (DAC-ABO) for booksize motor
New functions modules as hardware basis for the following new functions:
STARTER
Safety Integrated extended functions (SS1, SS2, SOS, SLS, SSM)
Edge modulation
Planned release and Order No. [MLFB] for the internal air cooled
versions, external air cooling and Cold-Plate cooling :
3A...200A (scheduled release 03/2007) 6SL312x-xTExx-xAA3
Scheduled release and Order No. [MLFB] for the internal air-cooled
versions, external air cooling and Cold-Plate cooling:
16kW...120kW (scheduled release 03/2007) 6SL313x-xTExx-xAA3
New components
components Active Interface Module (AIM) booksize format
New functions
Filter / reactor unit for Active Line Modules (ALM) booksize
STARTER
HF reactor
STARTER Cd
T4 T5 T6
D4 D5 D6
New components
components
Supplementary functionality AIM to the HF reactor:
Step-up factor up to 2 (instead of 1.6)
New functions
Total cable length up to 1000m (instead of 350m)
using improved damping behavior of the line reactor
STARTER
Integrated temperature sensor (protection against
overheating)
Terminals are safe to finger touch (IP20)
Integrated switching frequency filter ("Clean-Power")
Integrated basic interference suppression to maintain
Category C3 55kW
300mm
Additional features:
Compact design using forced ventilation/cooling
Suitable for connection to IT line supplies
=> disconnect the ground connection of the basic
interference suppression
80 / 120 kW
New components
components AC Drive chassis units with liquid cooling
New functions
Liquid cooling with integrated stainless steel heat exchanger, suitable
for enclosed (wrt the atmosphere) or open cooling systems
STARTER High power density: For the same electrical data, significantly more
compact when compared to the air-cooled version
Significantly lower noise level with respect to the air-cooled version
Can be mounted on the rear panel – either vertically or
horizontally
New components
components
TM54F (Terminal Module Failsafe)
Safety Terminal Module to control Safety Integrated extended functions:
STO, SBC, SS1, SS2, SOS, SLS, SSM
New functions 6SL3055-0AA00-3BA0 (scheduled release 05/2007)
STARTER CUA32 (Control Unit Adapter for PM340)
Control Unit Adapter (as for CUA31) – additionally with onboard
HTL/TTL encoder evaluation to 15-pin Sub-D socket
6SL3040-0PA01-0AA0 (scheduled release 05/2007)
Redesign CU310
PMIF connector has been modified =connection CU<>power unit (increased
ruggedness)
Additional KTY84 evaluation on the HTL/TTL encoder evaluation
Equipping possibility for D410
Safety certification (STO, SBC, SS1) – only for redesign CU
CU310 DP (scheduled release 05/2007) 6SL3040-0LA00-0AA1
CU310 PN (scheduled release 05/2007) 6SL3040-0LA01-0AA1
New components
components
Features
DRIVE-CLiQ integrated in the encoder
New functions SME and SMC not required
IP 67 degree of protection
STARTER
Synchronous flange / clamping flange / hollow shaft
Absolute encoder
Singleturn and multiturn
Resolution, singleturn encoder: 22 bit ST
Resolution, multiturn encoder: 22 bit ST, 12 bit MT
Customer benefits
Cost saving through system cabling
Lower space requirement by eliminating SMC / SME
New components
components
New functions
STARTER
STARTER
DCC (Drive Control Chart) with graphic interconnection Editor (DCC Editor)
Graphically configurable blocks (logic, arithmetic and closed-loop control functions)
Block types that can be freely instantiated (flexible scope)
Can run on SIMOTION and SINAMICS controllers (DCC SINAMICS, DCC SIMOTION)
New components
Overview (2):
STARTER project is directly saved on the CF card (without a controller on site)
New functions
functions
Edge modulation in the vector control type – also for booksize units
STARTER (higher output voltages)
Higher output frequencies in the V/f mode – e.g. for textile applications
(up to 600Hz)
New components
Overview (3):
Safety Integrated extended functions:
New functions
functions
Safety functionality integrated in the drive that can be controlled via Profisafe
(PROFIBUS) or the safety Terminal Module TM54F:
STARTER STO (Safe Torque Off) – torque safely turned off (previously SH – safe standstill)
SBC (Safe Brake Control)
SS1 (Safe Stop 1) STO after a delay time has expired, zero speed with no torque
SS2 (Safe Stop 2) SOS after a delay time has expired, zero speed with full torque
SOS (Safe Operating Stop) – safe operating stop with full torque
SLS (Safely-Limited Speed)
SSM (Safe Speed Monitor) – safety-relevant feedback signal of the limited speed
(safety-relevant zero speed detection, (n<nx) at a safety-relevant output)
New components Automatic controller setting for servo (frequency response analysis)
New functions
functions Automatic setting of the speed controller and the DSC position controller
(with SCOUT) based on transfer functions in the frequency range.
STARTER
The automatic speed controller setting has the following features:
Control loop identification using FFT analysis
Filters are automatically set in the current setpoint arm – e.g. to dampen
resonance effects
Automatic controller setting (gain factor Kp, integral action time Tn)
New components
2 3
New functions
functions
STARTER
4 Result
1
Accept, Yes/No
New components
New functions
functions
After
STARTER
Before
After
Before
New functions
functions Previously, it was necessary to enter the rated line frequency (50Hz or
60Hz line supply) when configuring/engineering the infeed unit.
STARTER
Disadvantage: If, for different rated line supply frequencies at the
commissioning and installation location, the parameters for the rated
line supply frequency were not adapted, then after booting, the drive
system output a message.
New components
New functions
functions
STARTER
2 .4
V
.5
V2
New components
New functions
functions
STARTER
1
New components
Edge modulation in the vector control type – also for booksize units
A higher output voltage can be achieved using edge modulation. This means that
New functions
functions
the drive converter output voltage can reach the connected line supply voltage
level – even when using non-regulated infeed units without step-up controller
STARTER values.
For SINAMICS chassis units, edge modulation has been implemented since FW
V2.3. For the booksize units, the function is enabled with FW V2.5 in conjunction
with the power units with new gating unit Asic (DAC-ABO) (6SL312x-xTExx-xAA3).
For reasons of stability, in practice (steady state), approx. 3% control margin to the
theoretical maximum value of the output voltage is maintained. This means that
the max. output voltage is given by:
0.72 * Vd (with edge modulation)
0.67 * Vd (without edge modulation)
New components
Functions in the topology view and DRIVE-CLiQ topology rules
The topology view has been expanded by the following functions:
New functions A DRIVE-CLiQ hub has been inserted
Components and their display (sub-topology) can be activated / deactivated
STARTER
DRIVE-CLiQ topology rules are taken into account for the offline configuration
topologies that can run from the offline configuration
New functions
Screen forms to graphically configure the pulse encoder emulation of the
TM41 module
STARTER
STARTER
4
SINAMICS 03/2007, Page 32
© Siemens AG 2006 - We reserve the right to make changes
Automation and Drives
Motion Control
SIMOTION