Humidity Sensor

Presented by:
Key Kai Wong
Outline
• What is Relative Humidity
• Manufacturers of Humidity Sensor
• Humidity Sensor from Honeywell ( HIH series)
• Humidity Sensor from Sensirion ( SHT Series)
• Comparision..
• Conclusion
• Reference
What is Relative Humidity (RH)

Measurement - Relative humidity (RH) is the amount


of water vapor in the air compared with the amount of
vapor needed to make the air saturated at the air's
current temperature

Example:
At 3 p.m. the air has 9 grams of water vapor per cubic
meter of air. We divide 9 by 30 and multiply by 100 to get
a relative humidity of 30%
Water vapor air can hold in degrees C

30 degrees 30 grams per cubic meter of air


20 degrees 17 grams per cubic meter of air
10 degrees 9 grams per cubic meter of air

.
Manufacturers of Humidity Sensor

Honeywell Sensirion
( HIH series ) ( SHT Series )
Humidity Sensor from Honeywell
( HIH series)
• Packages are chemically resistant
• operate in ranges of -40 °C to 85 °C (
-40 °F to 185 °F)
• Response time -15 sec in slowly moving
air at 25 °C
• Low power design – 200 microA @ 5
Vdc
• Operating volatge 4 – 5.8 v
• On-chip signal processing ensures
linear voltage output versus %RH.
• $35 - $40 per unit price
HIH-3610 Series
Humidity Sensor from Sensirion
( SHT Series )

• 2 sensors for relative humidity & temperature


• Very easy-to-use due to calibration & digital 2-
wire interface
• Calibrated & digital output (2-wire interface)
• Fast response time < 4 sec.
• Temp. accuracy: +/- 0.5°C @ 25 °C
• Low power consumption (typ. 30 µW)
• Operating Voltage 2.8 - 5.5v
• Cost $18 - $24 per unit price
Series interface
Comparision..
Honeywell Sensirion
( HIH series ) ( SHT Series )
• Response time -15 sec in slowly • Fast response time < 4 sec.
moving air at 25 °C
• Low power design – 200 microA @ 5 • Low power consumption (typ. 30
Vdc µW)
• Operating volatge 4 – 5.8 v • Operating Voltage 2.8 - 5.5v
• $35 - $40 per unit price • Cost $18 - $24 per unit price
• On-chip signal processing ensures • 2 sensors for relative humidity &
linear voltage output versus %RH. temperature
• Very easy-to-use due to calibration &
digital 2-wire interface
• Calibrated & digital output (2-wire
interface)
• Temp. accuracy: +/- 0.5°C @ 25 °C
Conclusion

After considering the aspect of the operating


voltage, cost, response time and the output of
the sensor. Sensor SHT series is more suitable
for our application.
References

• Honeywell
http://content.honeywell.com/sensing/prodinfo/humiditymoisture/#applications

• Sensirion
http://www.sensirion.com/en/sensors/humidity/default.htm

• USToday
http://www.usatoday.com/weather/wrelhum.htm

You might also like