Professional Documents
Culture Documents
Present Fluid
Present Fluid
Serious efforts have been undertaken to develop the structural control concept into a
workable technology and such devices are installed in structures.
The structural control system is usually classified by three method. The three classes of
structural control system are
1. Active Energy Dissipation
2. Semi-Active Energy Dissipation
3. Passive Energy Dissipation
Passive Energy Dissipation:
The passive energy systems are devices which are used to
dissipate the seismic effect.
The main function of the passive devices is to absorb a part of
earthquake energy i.e., input energy, reducing earthquake
energy or force on structural members and to reducing
the percentage of the damage to the structures.
Comparing to semi-active or active systems there is no need
of external power supply to passive control system.
Made up of steel.
They are designed to deform so much when the building vibrates during an
earthquake that they cannot return to their original shape
Viscous Damper:
Viscous damper are the energy dissipation device. This type of damper are very robust
and they are used in vehicles.
Viscous dampers works in the presence of fluid which will flow through orifice.
When piston moves this forces the liquid to move from one chamber to another
generating the resisting force.
Elasto plastic damper
An elasto-plastic damper to protect a building from destructive impact of seismic
tremors and/or high winds.
Working:
The viscous damper works on the principle of flow of fluid
through the orifice in the chamber.
The silicone -based fluid is used in the chamber.
The piston which is made up of stainless steel travels in
the chamber which is filled by the silicone oil.
The characteristic of the silicone oil is inert,non-
flammable, nontoxic and extremely stable for a period
of long time.
The pressure or force developed by the earthquake will
be of different.
This difference in pressure between two chambers will
force the oil to flow through orifice in piston head.
The inside energy is transferred into heat which will
dissipate into the atmosphere.
These dampers can be operated in the temperature
fluctuation of about -C to +C.
Due to easy n installation, adaptable and having variety in
their sizes, these dampers have more application in
designing and retrofitting of the structure.
Basic Way of Applying Damper:
The
three basic ways to apply the damper to the structure:
1. Base isolation
2. Damper for chevron bracing system
3. Damper for diagonal bracing system
1):Base isolation:
When
a building is built away (isolated) from the ground,
resting on flexible bearings or pads known as base isolators.
it will only move a little or not at all during an earthquake.
Base isolation is a technique developed to prevent or
minimise damage to buildings during an earthquake. It has
been used in New Zealand, as well as in India, Japan, Italy
and the USA.
One of the world's first base-isolated structures – the William
Clayton building in Wellington, built in 1982 – uses about 80
lead rubber bearings.
2):Damper for chevron bracing system:
3):Damper for diagonal bracing system