You are on page 1of 1

TALL STRUCTURES AND IS16700 - 2017

Openings in Diaphragms Materials


TALL BUILDING
The definition of tall building is subjective, that is defined against Minimum grade -M 30.
various perspectives i.e. Height relative to context, Proportion Maximum grade - M 70.
Embracing Technology
According to various height classifies as
tall, sky scraper, super tall, mega tall
IS 16700-2017 Wind effects
This standard is applicable for RC buildings of
height >50m & ≤250m. Min design wind shears and moments -higher of
Code specially guide for, 1) wind tunnels studies
- Wind and seismic effects , 2) 70% of that derived based on IS 875 (Part 3), and Wind
- Cracked and uncracked properties of concrete members for distribution as per wind tunnel study
analysis, Tensional velocity below 0.003 rad/s for 10 year return period.
- Foundation issues, The damping ratio <2%
- Structural health monitoring,
- The software for structural analysis and modelling of building Building Use Maximum Peak Combined
- Guidelines for Approval Process for code exceeding buildings, Acceleration(m/s2)

Structural Systems and Subsystems Residential 0.15


1. Structural wall systems; Mercantile 0.25
2. Moment frame systems; [permissible peak combined acceleration](Clause 6.2.3)
3. Moment frame — Structural wall systems;
4. Structural wall — Flat slab floor systems Seismic- Min Base Shear Coefficient
with perimeter moment frame SI Building Seismic Zone
No Height ,H
5. Structural wall — Framed tube systems II III IV V
6. Framed-tube system
7. Tube-in-tube system 1) H≤120m 0.7 1.1 1.6 2.4
8. Multiple tube system 2) H≥200m 0.5 0.75 1.25 1.75
9. Hybrid system; [minimum design base shear coefficient](Clause 6.3.3)
Height Limitations of Different Structural Systems Backstay effect
Load Path

Direct Load Path Back Stay Effect


SI no Seismic Structural System
zone
Moment Structural Wall Structur Structur Structur
Frame al Wall al al Wall+
Located Well +Mome Wall+Pe Framed
at Core Distribu nt rimeter Tube
ted Frame Frame
1 V NA 100 120 100 120 150
2 IV NA 100 120 100 120 150
3 III 60 160 200 160 200 220
4 II 80 180 220 180 220 250

[Maximum values of height, H above top of base level of


buildings with different structural systems](Clause 5.1.1) Foundation
Slenderness Ratio FOS=1.5 shall be provided against overturning and sliding under,
SI No Seismic Structural System 1) unfactored design wind and gravity loads
Zone
Moment Structure Wall Structur Structural Structural
2) 2.5 times design earthquake load and unfactored gravity loads.
Frame e Wall+ Wall+ Wall+
Located Well Moment Perimeter Framed
At Core Distribute Frame Framed Tube
d
1 V - 8 9 8 9 9 Depth of Bore hole ≥ 1.5B in Soil
2 IV - 8 9 8 9 9 ≥ 30 m in Rock
3 III 4 8 9 8 9 10

4 II 5 9 10 9 10 10

[maximum slenderness ratio (Ht/Bt)](Clause 5.1.2) GROUP A-4(ME -1 STRUCTURAL ENGINEERING )


Plan Aspect Ratio ROLL NO STUDENT NAME GUIDED BY
- Lt/Bt<5.0
where, Lt=length of the tower above podium level. 159 SOHAM TRIVEDI Dr. D.R. Panchal
Bt=width of the tower above podium level. 176 SAGAR VARIYA
Mr. Dishant Prajapati
171 PRASHANT KANZARIA

You might also like