ION7550/ION7650
Energy and power quality meters
Purpose
● Reasons to buy
● Multipoint, multi-protocol communications
● PQ compliance monitoring
● Transient detection
● Waveform recording sampling rate
● High accuracy revenue metering
● ITC (Instrument Transformer Compensation). Eliminates need to replace
Instrument transformers where accuracy is required
● Transformer losses compensation when the meter is in a different location
than the billing point.
Sampled Source
Sampling Point
Re-created Signal
Amplitude (%)
70
60
50
40
30
20
10
0
1 3 5 7 9 11
Harmonic Component
Amplitude (%)
70
60
50
40
30
20
10
0
1 3 5 7 9 11
Harmonic Component
Sampled Source
Sampling Point
Re-created Signal
PQA 2004
Schneider Electric - Division - Name – Date 14
What is new with firmware 350?
● Setpoint learning
● Provides gateway functionality when the Ethernet port and/or modem options
are present
● Modbus Master allows front panel display of real-time parameters from any
downstream Modbus devices.
EtherGate ModemGate
● Some applications as Data Centers and Critical Power require SNMP protocol
to map (convert) registers or data from the meter in to usable information for the
different systems.
● This implementation of the ION7650 and 7550 supports read only mode, except
for the following SNMP related text strings:
● System Contact
● System Name
● System Location
● You can also customize the text on the meter’s MIB (Management Information
Base) file: ion7x50schneiderMIB.asn.
P765
C
ION7550 /
7650 Comm Order Code Description
Card*
Comm Card P765C ION7550 / ION7650 Communications card for field retrofit installations
C1 Standard communications plus 10/100BASE-T Ethernet (RJ-45), 56k universal internal modem (RJ-
11; the modem port is shared with the front optical port). Ethernet and modem gateway functions each
use a serial communications port.
D7 Standard communications plus 10/100BASE-T Ethernet, 100BASE-FX Ethernet Fiber, 56k universal
internal modem (RJ-11; the modem port is shared with the front optical port).
Ethernet and modem gateway functions each use a serial communications port.
E0 Standard communications plus 10/100BASE-T Ethernet. Ethernet gateway function uses a serial
communications port.
F1 Standard communications plus 10/100BASE-T Ethernet, 100BASE-FX Ethernet Fiber (SC fiber optic
connection). Ethernet gateway function uses a serial communications port.
M1 Standard communications plus 56k universal internal modem (RJ-11; the modem port is shared with
the front optical port). Modem gateway function uses a serial communications port.
● Example of New Part Number with one of the new communications options:
M7650B1C0B6F1A0E
Communications ■ A0.- Standard Comms: 1 RS232/RS485 port (COM1), 1 RS485
(COM2), Integrated display models also include a Type 2 ANSI
optical port (COM4)
● Version 5.6 SP1 supports all new features of the ION75/7650 firmware
version 350