Professional Documents
Culture Documents
RCC WORKS
MEASUREMENTS
The form work shall include the following:
a) Splayed edges, notching, allowance for overlaps and passing at angles,
sheathing battens, strutting, bolting, nailing, wedging, easing, striking and
removal.
b) All supports, struts, braces, wedges as well as mud sills, piles or other suitable
arrangements to support the form work.
c) Bolts, wire, ties, clamps, spreaders, nails or any other items to hold the
sheathing together.
d) Working scaffolds, ladders, gangways, and similar items.
e) Filleting to form stop chamfered edges of splayed external angles not
exceeding 20mm wide to beams, columns and the like.
f) Where required, the temporary openings provided in the forms for pouring
concrete, inserting vibrators, and cleaning holes for removing rubbish from the
interior of the sheathing before pouring concrete.
g) Dressing with oil to prevent adhesion and
h) Raking or circular cutting
CLASSIFICATION OF MEASUREMENTS
Where it is stipulated that the form work shall be paid for separately,
measurements shall be taken of the area of shuttering in contact with the
concrete surface. Dimensions of the form work shall be measured correct
to a cm. The measurements shall be taken separately for the following.
(a) Foundations, footings, bases of columns etc. and for mass concrete
(b) Walls (any thickness) including attached pilasters, buttresses, plinth and
string courses etc.
(c) Suspended floors, roofs, landings, shelves and their supports and
balconies.
(d) Lintels, beams, plinth beams, girders, bressummers and cantilevers.
(e) Columns, pillars, piers, abutments posts and struts.
(f) Stairs (excluding landings) except spiral staircase.
(g) Spiral staircases (including landings).
(h) Arches, Domes, vaults, shells roofs, arch ribs, curvilinear shaped folded
plates
MEASUREMENT AND RATES
Form work of elements measured under categories of arches, arch ribs,
domes, spiral staircases, well steining, shell roofs, curvilinear folded
plates & curvilinear eaves board, circular shafts & chimneys shall not
qualify for extra rate for circular work.
Extra for circular work shall be admissible for surfaces circular or
curvilinear in plan or in elevation beyond the straight edge of supporting
beam in respective mode of measurement. However, there may be many
different types of such structures. In such cases, extra payment shall be
made judiciously after deducting areas where shuttering for circular form
work is not involved.
RATE : The rate of the form work includes the cost of labour and materials
required for all the operations described above.
REINFORCEMENTS
RATE : The rate for reinforcement shall include the cost of labour and
materials required for all operations described above such as cleaning of
reinforcement bars, straightening, cutting, hooking bending, binding,
placing in position etc. as required or directed including tack welding on
crossing of bars in lieu of binding with wires.
NOMINAL MIX
MEASUREMENTS : Dimensions shall be measured nearest to a cm
except for the thickness of slab which shall be measured correct to 0.5
cm. The areas shall be worked out nearest to 0.01 Sq. mt. The cubical
contents shall be worked out to nearest 0.01 cubic metre.
Reinforced cement concrete whether cast-in-situ or pre cast shall be
classified and measured separately as follows.
1. Raft, footing, bases of columns and mass concrete etc. all work up to
plinth level, column up to plinth level, plinth beams.
2. Wall (any thickness) including attached pilasters, buttresses plinth and
string course, fillets, column, pillars, piers, abutments, post and struts
etc.
3. Suspended floors, roofs, landings and balconies.
4. Shelves
5. Chajjas
6. Lintel, beams and bressummers.
7. Columns, pillars, piers, abutments, posts and struts.
MEASUREMENTS
Work under the following categories shall be measured separately.
(a) Rafts, footings, bases of columns etc. and mass concrete.
(b) All other items upto floor two level.
(c) From floor two level to floor three level and so on.
(d) R.C.C. above roof level shall be measured along with R.C.C. Work in floor just below.
Measurement shall be taken before any rendering is done in concrete members.
Measurement will not include rendering.
The measurement of R.C.C. work between various units shall be regulated as below:
(a) Slabs shall be taken as running continuously through except when slab is
monolithic with the beam.
(b) Beams shall be measured from face to face of columns and shall be including
haunches, if any, between columns and beam.
(c) The columns measurements shall be taken through.
(d) Chajjas along with its bearing on wall shall be measured in cubic metre nearest to
two places of decimal. When chajjas is combined with lintel, slab or beam, the
projecting portion shall be measured as chajjas, built in bearing shall be measured
as per item of lintel, slab or beam in which chajja bears.
RATE
The rate included the cost of materials and labour involved in all the
operations described above except for the cost of centering and
shuttering, finishing & reinforcement.
On the basis of mandatory lab tests, in case of actual average
compressive strength being less than specified strength but upto 70% of
specified strength, the rate payable shall be in the same proportion as
actual average compressive strength bears to specified compressive
strength.
Example: 1. Average compressive strength in 80% of specified strength.
Rate payable shall be 80% of agreement rate.
2. In case average compressive strength is less than 70% of the specified
strength, the work represented by the sample shall be rejected.
ENCASING ROLLED STEEL
SECTIONS
MEASUREMENTS :The length shall be measured correct to one cm and
other dimensions correct of 0.5 cm.
The cement concrete shall be measured as per gross dimensions of the
encasing exclusive of the thickness of plaster.
No deduction shall be made for the volume of steel sections, expanded
metal, mesh or any other reinforcement used therein.
However, in case of boxed stanchions or girders, the boxed portion only
shall be deducted. Fabric reinforcement such as expanded metal shall be
measured separately in square metres stating the mesh and size of
strands.
The description shall include the bending of the fabric as necessary,
Racking or circular cutting and waste shall be included in the description
RATE
The rate shall include the cost of materials and labour required for all the
operations described above except the cost of fabric reinforcement. The
cost of providing and erecting steel section and wire hangers shall be
paid for separately
PRECAST REINFORCED CONCRETE