Professional Documents
Culture Documents
2 I Amy
Accu-Chek
| Stanley
Instant_Instant
I Accu-ChekS Overview
Instant Launch
© 2017
Meeting
Roche –Diabetes
Spain Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Accu-Chek Instant / Accu-Chek Instant S
Only Effortless Features By Design
Accu-Chek
3 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant / Accu-Chek Instant S
Only Effortless Features By Design
Accu-Chek
4 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
New to Accu-Chek!
No set up – NO HASSLE!
One button – EFFORTLESS!
Simplified functionality – ONLY WHAT YOU NEED!
Clean display – BIG READINGS!
EASE OF
USE! LOW
Averages
COST!
Accu-Chek
7 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Customize
Target Range
Accu-Chek
8 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
New to Accu-Chek:
Standout design
No time/date unless
wanted
One button
Accu-Chek
9 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
About time & date…
Accu-Chek
10 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Time & Date…
Accu-Chek
18 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant / Accu-Chek Instant S
At a glance…
Specification Accu-Chek Instant Accu-Chek Instant S
19
19I Amy Stanley TYPE
| | FOOTER: I Accu-Chek
OVERInstant
HERE Launch Meeting – Spain
www.accu-chek.com
www.accu-chek.com © ©2016
© 2016Roche
2014 RocheDiabetes
Roche DiabetesCare
Care
Diagnostics | | Day Month Year
Meter Specification
Mainly the same with a few differences
Spec/Feature Accu-Chek Instant Accu-Chek Instant S
Memory
Last Result & 7, 3-, 90 day averages Yes Yes
For other data, transfer results to Smartphone/PC Yes/Yes No/Yes
720 results capacity for transfer Yes Yes
System Performance:
Test time: <4 seconds
Sample Size: 0,6 microliter
Accuracy: 10/10
Blood Samples: c, n, a, v
AST: Accu-Chek Instant: Yes (forearm, upper arm, hypothenar, hyperthenar)
Accu-Chek Instant S: Just passed testing….pending approval
22
22I Amy Stanley TYPE
| | FOOTER: I Accu-Chek
OVERInstant
HERE Launch Meeting – Spain
www.accu-chek.com
www.accu-chek.com © ©2016
© 2016Roche
2014 RocheDiabetes
Roche DiabetesCare
Care
Diagnostics | | Day Month Year
How-to-use the meter…
Accu-Chek
23 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Turn meter on, see last result
Accu-Chek
24 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Turn meter on, see last result
New icon
Accu-Chek
25 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Continue to press button for averages
Accu-Chek
26 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Control Testing
1. Obtain control result
2. In 15 seconds, L-1 or L-2 automatically displays (or button may be pressed to
immediately advance to L-1 or L-2)
3. The “1” or “2” flashes
4. Long press to save control level (or meter times out and automatically saves level)
Accu-Chek
27 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Now, let us go into additional product training
Accu-Chek
33 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant meter
Button
Target
Display range
indicator
USB
Target range indicator – indicates whether your bG result is below, within or above a pre-set range
• The meter automatically stores at least 720 blood glucose results in memory, but
only the last blood glucose result and your 7-, 30-, and 90-day averages can be
viewed on the meter
- To view stored blood glucose results, transfer them to a compatible software application
• The meter automatically stores at least 30 control results in memory, but only the
current control result can be viewed on the meter
- To view stored control results, transfer them to a compatible software application
• If more than 720 blood glucose tests are performed within a 90-day period, only the
720 most recent test results are included in the 90-day average
Meter button: The Instant meter has only one button, but it performs
many actions.
• Press the meter button once to turn the meter on and see your
most recent blood glucose result
• Continue pressing to view your 7-, 30-, and 90-day blood glucose
averages
• When instructed to press the meter button, press it briefly and
release it
• When instructed to press and hold the meter button, press and hold
it for 3 or more seconds
Target Range
Consult your healthcare professional for the blood glucose range
appropriate for you
It is very important to stay within your target range
- The target range is set by default at 70–160 mg/dL (3.9–8.9 mmol/L)
- The target range can be set from a lower limit of 60–140 mg/dL (3.3–7.8
mmol/L)
- The target range can be set from an upper limit of 90–300 mg/dL (5.0–
16.6 mmol/L)
To change the target range, pair the Instant meter to a mobile device,
or connect it to a PC with diabetes management software installed
and then follow the diabetes management software instructions
• Open the battery door by pushing the tab in the direction of the arrow and pull the door up
• Remove the old batteries, then press and hold meter button for 2 seconds
• Slide new batteries under the tabs with “+” up, then replace the battery door and snap close
• Always replace both batteries at the same time with the same brand
• Meter data is NOT lost when batteries are replaced
Press and hold the meter button until all display segments appear
Check the meter display for missing segments
All segments should look like the picture above (mmol/L not listed, but would be to the left
of the mg/dL)
If any segments are missing from the display, there may be an issue with the meter – contact
your local Accu-Chek Customer/Contact Center
**Strong electromagnetic fields may interfere with the proper operation of the meter. Do not use
the meter close to sources of strong electromagnetic radiation. To avoid electrostatic discharge, do
not use the meter in a very dry environment, especially one in which synthetic materials are
present**