You are on page 1of 43

Accu-Chek® Instant / Accu-Chek ® Instant S

Product Overview and Training


January 2017

Experience what’s possible.


In a word?
EFFORTLESS!

2 I Amy
Accu-Chek
| Stanley
Instant_Instant
I Accu-ChekS Overview
Instant Launch
© 2017
Meeting
Roche –Diabetes
Spain Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Accu-Chek Instant / Accu-Chek Instant S
Only Effortless Features By Design

Big bold result in backlit display

Accu-Chek
3 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant / Accu-Chek Instant S
Only Effortless Features By Design

• Big bold result in backlit display


• Easy, intuitive one-button navigation
• Last result (only result viewable on-board)
• 7 day average
• 30 day average
• 90 day average

Accu-Chek
4 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
New to Accu-Chek!

 No set up – NO HASSLE!
 One button – EFFORTLESS!
 Simplified functionality – ONLY WHAT YOU NEED!
 Clean display – BIG READINGS!

EASE OF
USE! LOW
Averages
COST!

5 I Amy Stanley IInstant_Instant


| Accu-Chek Accu-Chek Instant Launch ©
S Overview Meeting – Spain
2017 Roche Diabetes Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Only the most-used
features on-board…
For those wanting
more…
Connectivity
Accu-Chek
6 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Time & Date

Accu-Chek
7 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Customize
Target Range

Accu-Chek
8 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
New to Accu-Chek:
 Standout design
 No time/date unless
wanted
 One button

Accu-Chek
9 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
About time & date…

Accu-Chek
10 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Time & Date…

One button means:


 No time/date setup possible via meter
 Connectivity required for correct time/date

11 I Amy Stanley Instant_Instant


| Accu-Chek I Accu-Chek Instant Launch©Meeting
S Overview – Spain
2017 Roche Diabetes Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Time & Date…

One button means:


 No T/D setup possible via meter
 Connectivity required for correct time/date
Why we did it:
 >90% of returned Accu-Chek Active meters had no T/D set
 No scrolling through memory means
Accu-Chek Instant = EFFORTLESS
 Time & date is important for those who use data management

12 I Amy Stanley Instant_Instant


| Accu-Chek I Accu-Chek Instant Launch©Meeting
S Overview – Spain
2017 Roche Diabetes Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Time & Date…

One button means:


 No T/D setup possible via meter
 Connectivity required for correct time/date

Why we did it:


 >90% of returned Accu-Chek Active meters had no T/D set
 No scrolling through memory means
Accu-Chek Instant = EFFORTLESS
 Time & date is important for those who use data management – and
that’s why we keep the meter simple for stand-alone and rely on DMS
for add-ons

13 I Amy Stanley Instant_Instant


| Accu-Chek I Accu-Chek Instant Launch©Meeting
S Overview – Spain
2017 Roche Diabetes Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
Time & Date… First Time Download

 At least 720 BG results can be stored in the meter and downloaded

 If meter has never synched to a PC or device using Accu-Chek Connect,


Accu-Chek Connect Online, or Accu-Chek SmartPix DMS products, the
timestamps applied to the BG results will be based on Eastern Standard
Time

14 I Amy Stanley Instant_Instant


| Accu-Chek I Accu-Chek Instant Launch©Meeting
S Overview – Spain
2017 Roche Diabetes Care
www.accu-chek.com © ©2016
2014Roche
RocheDiabetes Care| 02/07/2021
Diagnostics
About the system…

Accu-Chek
18 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant / Accu-Chek Instant S
At a glance…
Specification Accu-Chek Instant Accu-Chek Instant S

Display Fixed segment with backlight Fixed segment


Connectivity USB and BLE USB
Battery 2 coin cells 1 coin cell
Color Black display surround/button Champagne display
surround/button

19
19I Amy Stanley TYPE
| | FOOTER: I Accu-Chek
OVERInstant
HERE Launch Meeting – Spain
www.accu-chek.com
www.accu-chek.com © ©2016
© 2016Roche
2014 RocheDiabetes
Roche DiabetesCare
Care
Diagnostics | | Day Month Year
Meter Specification
Mainly the same with a few differences
Spec/Feature Accu-Chek Instant Accu-Chek Instant S
Memory
 Last Result & 7, 3-, 90 day averages  Yes  Yes
 For other data, transfer results to Smartphone/PC  Yes/Yes  No/Yes
 720 results capacity for transfer  Yes  Yes

Meter size  Yes  Yes


 Length 77.28 x Thick 15.2 x Width 48.40 mm
Display
 Fixed Segment  Yes  Yes
 Backlight  Yes  No
Battery
 2 CR 2032 Coin Cell  Yes  No
 1 CR 2032 Coin Cell  No  Yes
Connectivity
 USB to PC  Yes  Yes
 BLE Wireless  Yes  No
Target Range Indication Color Bar
 20Defaulted
| | FOOTER: TYPEto 70-160
OVER HERE mg/dL (3.9-8.9 mmol/L)  Yes  Yes
© 2014
2016 Roche
Roche Diagnostics
Diabetes Care
| | Day Month Year
 Target Range Customizable
www.accu-chek.com ©
(with connectivity)  Yes  Yes
Accu-Chek Instant Test Strips
Both meters use the same strips

Both meters use same strip:


Branded Accu-Chek Instant
test strips

Accu-Chek Instant Meter Accu-Chek Instant S Meter

Accu-Chek Instant Test Strips


Not compatible with Accu-Chek Guide
21
21I Amy Stanley TYPE
| | FOOTER: I Accu-Chek
OVERInstant
HERE Launch Meeting – Spain
www.accu-chek.com
www.accu-chek.com © ©2016
© 2016Roche
2014 RocheDiabetes
Roche DiabetesCare
Care
Diagnostics | | Day Month Year
Key Features of the Accu-Chek Instant Strips

System Performance:
 Test time: <4 seconds
 Sample Size: 0,6 microliter
 Accuracy: 10/10
 Blood Samples: c, n, a, v
 AST: Accu-Chek Instant: Yes (forearm, upper arm, hypothenar, hyperthenar)
Accu-Chek Instant S: Just passed testing….pending approval

Difference between Accu-Chek Guide & Accu-Chek Instant test strips:

Specification AC Guide AC Instant


Vial type Oval Vial Round Vial
Strip graphics

22
22I Amy Stanley TYPE
| | FOOTER: I Accu-Chek
OVERInstant
HERE Launch Meeting – Spain
www.accu-chek.com
www.accu-chek.com © ©2016
© 2016Roche
2014 RocheDiabetes
Roche DiabetesCare
Care
Diagnostics | | Day Month Year
How-to-use the meter…

Accu-Chek
23 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Turn meter on, see last result

Accu-Chek
24 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Turn meter on, see last result

New icon

Accu-Chek
25 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Continue to press button for averages

Accu-Chek
26 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Control Testing
1. Obtain control result
2. In 15 seconds, L-1 or L-2 automatically displays (or button may be pressed to
immediately advance to L-1 or L-2)
3. The “1” or “2” flashes
4. Long press to save control level (or meter times out and automatically saves level)

Accu-Chek
27 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Now, let us go into additional product training

Accu-Chek
33 | Instant_Instant S Overview © 2017 Roche Diabetes Care
www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant meter

Button
Target
Display range
indicator
USB

Button – turn on/off, move to the next screen or make a selection

Display – shows results, messages and test results stored in memory

Target range indicator – indicates whether your bG result is below, within or above a pre-set range

USB port – transfers data from the meter to a PC

34 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Accu-Chek Instant meter

Battery door Test strip slot

2032 lithium coin


cell batteries

Test strip vial Test strip Control solution USB cable

35 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Technical information

Parameter Instant Test Strips


Test Time < 4 seconds
Sample Volume 0.6 µL
Measuring Range 10 – 600 mg/dL (0.6 – 33.3 mmol/L)
Operating
Temperature Range 4 – 45°C (39 – 113°F)
Operating Humidity Range
10 – 90% relative humidity
System Storage Temperature Range
4 – 30°C (39 – 86°F)
Altitude Up to 10,150 feet (3,094 meters) above sea level
Hematocrit Range 10 – 65%
Sample Types Instant meter: Capillary, venous, arterial, neonatal
Instant S meter: Capillary only
Alternate Site Testing Instant meter: Palm, forearm, and upper arm
Instant S meter: Just passed, awaiting approval
Shelf Life 18 months
Maltose Interference No Limitation
Galactose Interference No Limitation
Xylose Do not use the system during xylose absorption test
Sodium Interference No Limitation
Triglycerides >1800 mg/dL (20.3 mmol/L)
Ascorbic Acid
Do not use the system if undergoing intravenous administration of ascorbic acid
EDTA Sample Tubes No Limitation
Hemoglobin No Limitation
Lithium Heparin No Limitation

36 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Compatible software

 ACCU- CHEK Conne c t Diabe te s Manage me nt App (iOS and Android)

 ACCU- CHEK Conne c t Online (We b)

 ACCU- CHEK 360 ° Diabe te s Manage me nt Sys te m (Window s)

 ACCU- CHEK Smart Pix De vic e Re ade r (Mode l 2) (Window s)

37 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Overview of memory

• The meter automatically stores at least 720 blood glucose results in memory, but
only the last blood glucose result and your 7-, 30-, and 90-day averages can be
viewed on the meter
- To view stored blood glucose results, transfer them to a compatible software application

• The meter automatically stores at least 30 control results in memory, but only the
current control result can be viewed on the meter
- To view stored control results, transfer them to a compatible software application

• If more than 720 blood glucose tests are performed within a 90-day period, only the
720 most recent test results are included in the 90-day average

38 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Information to know…..

Meter button: The Instant meter has only one button, but it performs
many actions.
• Press the meter button once to turn the meter on and see your
most recent blood glucose result
• Continue pressing to view your 7-, 30-, and 90-day blood glucose
averages
• When instructed to press the meter button, press it briefly and
release it
• When instructed to press and hold the meter button, press and hold
it for 3 or more seconds

39 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Information to know…..

Time and Date


To display or change the time and date on the meter
• Pair the meter to a mobile device OR connect it to a PC with
diabetes management software installed
• Follow the diabetes management software instructions to set the
time and date
• The meter display will then show the time and date along with your
test results

40 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Information to know…..

Target Range
Consult your healthcare professional for the blood glucose range
appropriate for you
It is very important to stay within your target range
- The target range is set by default at 70–160 mg/dL (3.9–8.9 mmol/L)
- The target range can be set from a lower limit of 60–140 mg/dL (3.3–7.8
mmol/L)
- The target range can be set from an upper limit of 90–300 mg/dL (5.0–
16.6 mmol/L)
To change the target range, pair the Instant meter to a mobile device,
or connect it to a PC with diabetes management software installed
and then follow the diabetes management software instructions

41 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Target range indicator

Blue – test result is ABOVE target range

Green – test result is WITHIN target range

Red – test result is BELOW target range

The test result appears with an “arrow” and indicates if above,


within or below target range. If the “arrow” is flashing, it is
indicting the result is either above or below target range

42 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Changing the batteries

• Open the battery door by pushing the tab in the direction of the arrow and pull the door up

• Remove the old batteries, then press and hold meter button for 2 seconds
• Slide new batteries under the tabs with “+” up, then replace the battery door and snap close
• Always replace both batteries at the same time with the same brand
• Meter data is NOT lost when batteries are replaced

45 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Display Check

Press and hold the meter button until all display segments appear
Check the meter display for missing segments
All segments should look like the picture above (mmol/L not listed, but would be to the left
of the mg/dL)
If any segments are missing from the display, there may be an issue with the meter – contact
your local Accu-Chek Customer/Contact Center

46 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Error Messages

**Strong electromagnetic fields may interfere with the proper operation of the meter. Do not use
the meter close to sources of strong electromagnetic radiation. To avoid electrostatic discharge, do
not use the meter in a very dry environment, especially one in which synthetic materials are
present**

47 | S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Error Messages

Strip Error before dosing Test Error (after dosing

Drop too small error

48 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Error Messages

49 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Error Messages

50 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Error Messages

51 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Other Meter Screens

52 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021
Other Meter Screens

53 | Accu-Chek Instant_Instant S Overview © 2017 Roche Diabetes Care


www.accu-chek.com © 2014 Roche Diagnostics | 02/07/2021

You might also like